• 제목/요약/키워드: Withstand Voltage Characteristics

검색결과 59건 처리시간 0.021초

362 kV GIB 내에서 건조공기의 절연파괴 특성 (Breakdown Characteristics of Dry Air under 362 kV GIB)

  • 한기선;주형준;윤진열;유홍근
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.804-808
    • /
    • 2010
  • In this paper, we studied the dielectric breakdown voltage characteristics by the AC withstand voltage test on using green insulation dry air instead of $SF_6$ insulation gas used in the GIB (gas insulated bus) of 362 kV GIS (gas insulated switchgear). The AC withstand voltage test applied to the standard KEPCO's 362 kV GIB with dry air insulation, and the equivalence of dielectric breakdown voltage for dry air and $SF_6$ gas were examined, and the empirical formulas of dielectric breakdown voltage for dry air were calculated, and the criterion of AC withstand voltage test for dry air insulation was derived. Using the criterion, dry air can be used instead of $SF_6$ gas for 362 kV GIB in the factory acceptance test was confirmed.

초고압 피뢰기용 ZnO 소자의 장시간 방전내량 특성 평가 (Evaluation of Long Duration Current Impulse Withstand Characteristics of ZnO Blocks for High Voltage Surge Arresters)

  • 조한구;윤한수;김석수
    • 한국전기전자재료학회논문지
    • /
    • 제19권4호
    • /
    • pp.398-403
    • /
    • 2006
  • This paper describes the evaluation of the long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and the long duration current impulse withstand test, electrical uniformity evaluation test and microstructure observation were performed. All varistors exhibited high density, which was in the range of $5.42{\sim}5.46g/cm^3$. In the electrical properties, the reference voltage of samples was in the range of $5.11{\sim}5.25\;kV$ and the residual voltage was in the range of $8.314{\sim}8.523\;kV$. In the long duration current impulse withstand test, sample No.2 and No.3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived was below 0.5 %, which was in the acceptance range of 5 %. According to the results of the test, it is thought that if the soldering method is improved, ZnO varistors would be possible to apply to the high voltage arresters like the station class and transmission line arresters in the near future.

조명등기구 배선용 커넥터의 안전성 평가 및 분석에 관한 연구 (Safety Estimation and Analysis Study of the Connector for Lighting Fixture Wiring)

  • 최충석
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.541-545
    • /
    • 2009
  • This study evaluated the contact resistance, insulation resistance, withstand voltage characteristics and insertion force, etc., of the wire connector used inside an integrated LITE WAY lighting fixture developed for efficient installation. Since the connector connecting the lighting fixture's internal wires is housed, it is easily connected and separated and has a structure enabling a close-fitting connection. The temperature and time applied to the high temperature characteristics test of the connector are $105^{\circ}C$ and 16 hours, respectively. The measured contact resistance of the high temperature tested connector was 3.258 mV/A, and its measured insulation resistance was greater than $10\;G{\Omega}$ All specimens demonstrated uniform insulation characteristics, which could be seen to be in good condition. From the withstand voltage test results found before and after performing the high temperature operation test on the connector for cable connection, it was confirmed that the withstand voltage characteristics between all terminals were good. The insertion force of the connector connecting the internal wiring averaged 9.67 kgf. It was observed that the insertion force between the plug housing and the female terminal, and that between the plug housing and the male terminal, were 0.680 kgf and 1.27 kgf on average, respectively.

초고압 피뢰기용 ZnO 소자의 장시간 방전내량과 균일성 (Long Duration Current Impulse Withstand Characteristics and Uniformity of ZnO Blocks for High Voltage Surge Arresters)

  • 조한구;유대훈;이유정
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.486-487
    • /
    • 2007
  • This paper describes the evaluation of long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and three abroad varistors were also prepared to be compared. All varistors exhibited high density, which was in the range of $5.42{\sim}5.49g/cm^3$. In the electrical properties, the reference voltage of all samples was in the range of 5.11~5.72kV and the residual voltage was in the range of 8.314~9.305kV. In the long duration current impulse withstand test, sample 2 and 3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived were below 1.7%, which were in the acceptance range of 5%.

  • PDF

ZnO 바리스터 소자의 장시간 방전내량 특성 (Long Duration Withstand Current Characteristics of ZnO Varistors)

  • 조한구;윤한수;김석수;한세원;유근양;이용순
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.544-545
    • /
    • 2005
  • This paper describes the long duration withstand current characteristics of ZnO varistors. Two ZnO varistors were manufactured with general ceramic production methods and three abroad varistors were also prepared to be compared. During long duration withstand test, sample 1 was destroyed at 4th impulse current but the rest passed test. Before and After the test, the residual voltage variation of varistors passed was below 5%. According to the test results, it is thought that the manufacturing process such as insulating coating, sintering condition and soldering method should be improved.

  • PDF

170[kV] GIB 내에서 건조공기(Dry Air)의 절연파괴 특성 (Breakdown Characteristics of Dry Air under 170[kV] GIB)

  • 한기선;윤진열;주형준
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.136-142
    • /
    • 2010
  • In this paper, we changed $SF_6$ insulation gases used already in the GIB(Gas Insulated Bus, gas insulated busbar) of switching appliances of power grid 170[kV] GIS(Gas Insulated Switchgear, Gas Insulated Switchgear) with green insulation dry air gases and studied dielectric breakdown voltage characteristics by the AC voltage withstand test. Withstand test AC voltage applied to the standard KEPCO's 170[kV] GIB with dry air insulation and and the equivalent of dry air and $SF_6$ gas were examined. Breakdown voltage of dry air, using an expression of the experiments were calculated and AC Withstand criterion of dry air insulation for the AC voltage test was derived. Using the criterion, dry air gases can be used instead of the $SF_6$ gas was confirmed in the factory acceptance test at 170[kV] GIB.

Influence of SF6/N2 Gas Mixture Ratios on the Lightning Streamer Propagation Characteristics of 22 kV MV Circuit Breaker

  • Gandhi, R.;Chandrasekar, S.;Nagarajan, C.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1663-1672
    • /
    • 2018
  • In recent times, gas insulated medium voltage (MV) circuit breakers (CB) form a vital component in power system network, considering its advantages such as reduced size and safety margins. Gas insulation characteristics of circuit breakers are generally measured by lightning impulse (LI) test according to IEC standard 60060-1 as a factory routine test. Considering the environmental issues of $SF_6$ gas, many research works are being carried out towards the mixture of $SF_6$ gases for high voltage insulation applications. However, few reports are only available regarding the LI withstand and streamer propagation characteristics (at both positive and negative polarity of waveform) of $SF_6/N_2$ gas mixture insulated medium voltage circuit breakers. In this paper, positive and negative polarity LI tests are carried out on 22 kV medium voltage circuit breaker filled with $SF_6/N_2$ gas mixture at different gas pressures (1-5 bar) and at different gas mixture ratios. Important LI parameters such as breakdown voltage, streamer velocity, time to breakdown and acceleration voltage are evaluated with IEC standard LI ($1.2/50{\mu}s$) waveform. Weibull distribution analysis of LI breakdown voltage data is carried out and 50% probability breakdown voltage, scale parameter and shape parameter are evaluated. Results illustrate that the $25%SF_6+75%N_2$ gas filled insulation considerably enhances the LI withstand and breakdown strength of MV circuit breakers. LI breakdown voltage of circuit breaker under negative polarity shows higher value when compared with positive polarity. Results show that maintaining the gas pressure at 0.3 MPa (3 bar) with 10% $SF_6$ gas mixed with 90% $N_2$ will give optimum lighting impulse withstand performance of 22 kV MV circuit breaker.

동축 고온 초전도 케이블의 전류분포 및 mini-model 케이블의 전기절연 (The Characteristics of Current Distribution of a Coaxial HTS Cable and Insulation of Mini-model Cable)

  • 김영석;곽동순;백승명;김해종;김상현
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.47-50
    • /
    • 2003
  • In order to verify the extended theory, we have fabricated a two layers cable with the same twisting layer pitch. It was observed that almost all the operational current less than the critical current flowed on the outer layer because of its lower inductance. In case of operational current more than critical currents of layers, the flux flow resistances affect strongly current waveform and thereby the currents of layers were determined by the flux flow resistances. And we investigated withstand voltage, impulse voltage and breakdown characteristics of mini-model cable. In these test, the withstand voltage and impulse voltage test was satisfied and the breakdown voltage was 110kV.

  • PDF

Improvement of Electrochemical Characteristics and Study of Deterioration of Aluminum Foil in Organic Electrolytes for EDLC

  • Lee, Mun-Soo;Kim, Donna H.;Kim, Seung-Cheon
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권1호
    • /
    • pp.9-19
    • /
    • 2018
  • The anodic behavior of aluminum (Al) foils with varying purity, capacitance, and withstand voltage in organic electrolytes was examined for EDLC. The results of cyclic voltammetry (CV) and chronoamperometry (CA) experiments showed that the electrochemical stability improves when Al foil has higher purity, lower capacitance, and higher withstand voltage. To improve the electrochemical stability of EDLC current collectors made of low-purity foil (99.4% Al foil), the foil was modified by chemical etching to reduce its capacitance to $60{\mu}F/cm^2$ and forming to have withstand a voltage of 3 Vf. EDLC cells using the modified Al foil as a current collector were made to 2.7 V with 360 F, and a constant voltage load test was subsequently performed for 2500 hours at high temperature under a rated voltage of 2.7 V. The reliability and stability of the EDLC cell improved when the modified Al foil was used as a current collector. To understand the deterioration process of the Al current collector, standard cells made of conventional Al foil under a constant voltage load test were disassembled, and the surface changes of the foil were measured every 500 hours. The Al foil became increasingly corroded, causing the adhesion between the AC coating layer and the Al foil to weaken, and it was confirmed that partial AC coating layer peeling occurred.

Study on the Dielectric Characteristics of Gaseous Nitrogen for Designing a High Voltage Superconducting Fault Current Limiter

  • Heo, Jeong-Il;Hong, Jong-Gi;Nam, Seok-Ho;Kang, Hyoung-Ku
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.28-31
    • /
    • 2012
  • The study on the dielectric characteristics of gaseous insulation medium is important for designing current leads of superconducting machines using a sub-cooled liquid nitrogen ($LN_2$) cooling method. In a sub-cooled $LN_2$ cooling system, the temperature of gaseous insulation medium surrounding current leads varies from the temperature of coolant to 300 K according to the displacement between the electrode system and the surface of sub-cooled $LN_2$. In this paper, AC withstand voltage experiments on gaseous nitrogen according to temperature are conducted. Also, AC withstand voltage experiments on gaseous nitrogen according to pressure, size of electrode, and gap length between two electrodes are performed. It is found that there is a functional relation between the electrical breakdown voltage and the field utilization factor (${\xi}$). As a result, the empirical formula for estimating an electrical breakdown voltage is deduced by adopting the concept of field utilization factors. It is expected that the experimental results presented in this paper are helpful to design current leads for a high voltage superconducting apparatus such as a superconducting fault current limiter (SFCL) using a sub-cooled $LN_2$ cooling system.