• Title/Summary/Keyword: Withstand Test

Search Result 217, Processing Time 0.033 seconds

Contruction and Performance Evaluation of the Surge Arrester for Transmission Class (송전급 피뢰기의 구조와 성능평가)

  • Kim, S.S.;Choi, I.S.;Cho, H.G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.890-893
    • /
    • 2002
  • Since 1970s, varistors using metal-oxide resistors have been applied to Gapless surge arresters for power system. In the paper, the structure of metal-oxide surge arresters without gaps for 362kV GIS which is developed the first in korea has been introduced. And the main evaluation items for the metal-oxide resistors which are reference voltage test, residual voltage test, long duration current impulse withstand test and operating duty test is tested and evaluated.

  • PDF

A study on the air clearance in the metal-enclosed switchgear (폐쇄배전반내 모선의 절연이격거리)

  • Son, Jae-Hyun;Kim, Sun-Ku
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1917-1919
    • /
    • 1996
  • This paper aims to extract the air clearance in 22.9KV the metal enclosed switchgear. First, we investigated the actual conditions on the clearance in the metal enclosed switchgear which has been used in domestic. The test model and 9 test electrodes for the air insulation strength tests have been designed and manufactured based on the investigation results. To find optimal clearance in the metal enclosed switchgear, we performed 50% flash-over test by the up and down method and lightning impulse withstand voltage test. And we obtained results that the clearance or phase-to-phase is 230 [mm] and clearance or phase-to-earth is 210[mm].

  • PDF

Evaluation of 띠ectrical Uniformity of Zinc Oxide Varistors for Lightning Surge Arresters (초고압 피뢰기용 산화아연소자의 전기적 균일성 평가)

  • Cho, Han-Goo;Yoon, Han-Soo;Han, Se-Won
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.100-102
    • /
    • 2005
  • This paper presents evaluation of the electrical uniformity of zinc oxide varistors for lightning arresters. Two types of varistors were prepared which are a domestic varistor destroyed in the long duration current impulse withstand test and a new imported varistor. The domestic varistor exhibited good electrical uniformity except destroyed parts, but the imported varistor showed the worse results.

  • PDF

Computational Analysis of Short-Circuit Stresses in Power Transformer Windings (전력용 변압기의 단락강도 해석)

  • Choi, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.147-150
    • /
    • 2002
  • This paper describes the work performed by computer simulation to achieve a satisfactory method of predicting the short circuit withstand strength of transformer which, may be too big for test due to physical or economic reasons. In fact, the windings of power transformer are subjected to extremely severe stresses under short-circuit condition. From our work, however, were computed such stresses as buckling, tending and compression occurring in transformer windings.

  • PDF

Assessment of structural behavior of reinforced concrete slab ceiling under full load test in a residential complex project

  • Jaffar A. Kadim;Oday A. Abdulrazzaq;Abdulamir A. Karim;Aqeel H. Chkheiwer
    • Structural Engineering and Mechanics
    • /
    • v.89 no.6
    • /
    • pp.627-634
    • /
    • 2024
  • This research deals with the process of conducting a reinforced concrete slab loading test of a Residential Complex Project at the Shatt Al Arab District which is located in southern Iraq. The purpose of the test which represents a destructive test is to evaluate the structural behavior of the slab condition state during and after the examination of the test process in order to ascertain the ability of the slab ceiling to withstand the loads generated during the use of the building. The test was carried out accordant to ACI 437.2-13 code. The reason for this test is the postponed 8 years of building project construction. Concrete blocks were used to simulate and conduct a loading test of 30-tons for 3 days. The central point has been installed to measure the slab deflection that occurred during the test. The results showed that both the total deflection and residual deflections were lesser than the permissible values according to the ACI 437.2-13, the RC slab behavior was mainly linear structural behave, and that the purpose of the examination was achieved. Finally, a new method was introduced to the assessment of the slab condition at the support which is found in good condition.

The Study of Comparison of the Symmetrical Short Circuit Test Current with ANSI/IE Transformers. (변압기의 단락강도 시험 시 ANSI와 IEC 규격에 의한 시험 전류의 비교 연구)

  • Kim, Sun-Koo;Kim, Won-Man;La, Dae-Ryeol;Roh, Chang-Il;Lee, Dong-Jun;Jeong, Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.694-696
    • /
    • 2002
  • Transformers together with all equipment and accessories shall be designed and constructed to withstand the mechanical and thermal stresses produced by external short circuit which include three phase, single line-to-ground, double line-to-ground and line-to-line faults etc. Generally the Short Circuit Test of transformers is tested according to the ANSI/IEEE, IEC/JEC, KS etc, in domestic. In this study, it will be showed and compared the difference of symmetrical current for short circuit test of a Pad -mounted transformer according to with ANSI /IEEE and IEC.

  • PDF

The Structural Analysis and Experimental Verification for the Next Generation High Speed EMU (분산형 고속전철의 하중조건에 따른 정적 하중시험 평가)

  • Choi, Jeong-Yong;Jeong, Won-Wha;Park, Geun-Soo;Woo, Kwan-Je
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.307-313
    • /
    • 2011
  • Hyundai Rotem Company has designed and manufactured the next generation high speed EMU bodyshell (M3-car). Korean Railway Safety Law specifies the loads vehicle bodies shall be capable of withstanding, identifies what material data shall be used and presents the principles to be used for design verification by analysis. Therefore, in order to fulfill the structural requirements, Hyundai Rotem Company has carried out Finite Element Analysis (FEA) and static load test to verify whether the carbody structure has enough strength to withstand the loads specified by Korean Railway Safety Law. This research contains the results obtained by the FE analysis and static load test. The FE analysis is carried out using NX I-DEAS 6.1 and specially designed test jigs and equipment are used for the load tests.

  • PDF

The Properties of Breakdown and Test for Resistance to Cracking of Power Cable for PL Countermeasure (PL법 대응을 위한 전력케이블의 열 충격 및 절연파괴 특성)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.349-352
    • /
    • 2007
  • It is impossible to database(DB) the patterns of cable events and cause analysis of faulted cable because the product liability(PL) law have been enforced in Korea, since 2002. In additions, simulation and pattern of cable events are needed for DB system under accelerated deterioration. In this paper, we tested for resistance to nicking of cable below the 22.9kV class due to thermal stresses. This method of exam is following IEC 60811-3-1(Common test methods for insulating and sheathing materials of electric cables). First of all, set the cable in the thermal stress instrument, temperature changed from -20 degree to 120 degree. After thermal stress, we observed a surface crack of cable through microscope and carried out AC withstand voltage test.

  • PDF

Performance and Design of Cable Termination for 154kV Class (154kV 케이블 콘넥터의 설계와 특성 평가 연구)

  • Cho, Han-Goo;Kim, Kyang-Young;Lee, Cheol-Ho;Lee, Yong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.112-112
    • /
    • 2010
  • The purpose of development is to localize a connector for connection of cable and GIS for underground transmission system. The cable connector for GIS provides electrical insulation of GIS housing part and makes connection of ultra high voltage electrical apparatus and power cable by controlling electrical stress between electrodes of power cable termination. Generally Korean switchgear makers are using a connector for GIS made by foreign companies. We manufactured sample by best structure design of great capacity conductor connecting part and then modified the design by analysis of shape and section. We completed the suitable sample for current cycling test condition of conductor connecting part sample and ensured surge characteristics of line by short-time current test.

  • PDF

Shaking Table Test of the Model of Five-story Stone Pagoda of Sang-Gye-Sa Mounted on Base Isolation Systems (쌍계사 오층석탑모델에 대한 지진격리효과 진동대실험)

  • 김재관;이원주;김영중;김병현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.331-338
    • /
    • 2001
  • Seismic performances of the base isolated model of Five Story Stone Pagoda were studied through shaking table tests. Friction pendulum system (FPS), Pure-friction system with laminated rubber bearing (LRB) and Ball with rubber bearing were selected fur the comparison of performances. Performances of specially designed isolation systems were tested dynamically using shaking table. The test results of isolated model are compared with those of fixed base model. Compared with fixed base model, the isolated model showed that it could withstand much higer intensity of earthquake motion. The Effective Peak Ground Acceleration (EPGA) value of isolated model when the top component tipped over was above twice of that value in case of fixed base model. According to the additional test results, the lower value of coefficient of friction than that of common frictional base isolation systems is more effective to protect the piled multi-block system of Pagoda against moderate intesity of ground motion.

  • PDF