• Title/Summary/Keyword: Without transformer

Search Result 218, Processing Time 0.022 seconds

Improved Single-Stage AC-DC LED-Drive Flyback Converter using the Transformer-Coupled Lossless Snubber

  • Jeong, Gang-Youl;Kwon, Su-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.644-652
    • /
    • 2016
  • This paper presents an improved single-stage ac-dc LED-drive flyback converter using the transformer-coupled lossless (TCL) snubber. The proposed converter is derived from the integration of a full-bridge diode rectifier and a conventional flyback converter with a simple TCL snubber. The TCL snubber circuit is composed of only two diodes, a capacitor, and a transformer-coupled auxiliary winding. The TCL snubber limits the surge voltage of the switch and regenerates the energy stored in the leakage inductance of the transformer. Also, the switch of the proposed converter is turned on at a minimum voltage using a formed resonant circuit. Thus, the proposed converter achieves high efficiency. The proposed converter utilizes only one general power factor correction (PFC) control IC as its controller and performs both PFC and output power regulation, simultaneously. Therefore, the proposed converter provides a simple structure and an economic implementation and achieves a high power factor without the need for any separate PFC circuit. In this paper, the operational principle of the proposed converter is explained in detail and the design guideline of the proposed converter is briefly shown. Experimental results for a 40-W prototype are shown to validate the performance of the proposed converter.

A Study of Voltage Control for Lower Side Parallel Transformer (병렬운전 변압기 전압제어 및 저압축 모선보호방식연구)

  • Yun, Gi-Seob;Baek, Seung-Do;Choi, Hyuck-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.233-236
    • /
    • 2001
  • Parallel operation scheme to several transformers is adopted because of the load increase, economic problem, or load shedding. For the transformer's parallel operation, loads proportional to each transformer's capacity must be allotted, and circulation currents must be limited as much as without causing any problem in a real operation. But, both transformers in parallel operation can be tripped when either faults at lower voltage side of a transformer or faults in a bus occurs. Therefore, parallel operation scheme to distribution transformers in Korea is not adopted in a normal state but only when loaded or load-shedded. These are due to the insufficiency of the construction in communication network and AVR scheme. Besides that, those are because bus bar protection scheme to lower voltage side of a transformer is not applied. In spite of enormous initial investment costs, advanced countries take so much account of power system reliability and stable supply that they adopt the parallel operation scheme in a normal state. One of the problems in parallel operation is the overheat of transformers due to the excessive circulation currents. This paper presents the scheme that controls voltages between both transformers using circulation currents that occurs in parallel operation.

  • PDF

Modeling and Investigation of Multilayer Piezoelectric Transformer with a Central Hole for Heat Dissipation

  • Thang, Vo Viet;Kim, In-Sung;Jeong, Soon-Jong;Kim, Min-Soo;Song, Jae-Sung
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.671-676
    • /
    • 2011
  • A multilayer square-type piezoelectric transformer with a hole at the center was investigated in this paper. Temperature distribution at the center was improved by using this construction, therefore increasing input voltage and output power. This model was simulated and investigated successfully by applying a finite element method (FEM) in ATILA software. An optimized structure was then fabricated, examined, and compared to the simulation results. Electrical characteristics, including output voltage and output power, were measured at different load resistances. The temperature distribution was also monitored using an infrared camera. The piezoelectric transformer operated at first radial vibration mode and a frequency area of 70 kHz. The 16 W output power was achieved in a three-layer transformer with 96% efficiency and $20^{\circ}C$ temperature rise from room temperature under 115 V driving voltage, 100 ${\Omega}$ matching load, $28{\times}28{\times}1.8mm$ size, and 2 mm hole diameter. With these square-type multilayer piezoelectric transformers, the temperature was concentrated around the hole and lower than in piezoelectric transformers without a hole.

Voltage Balance Control of Cascaded H-Bridge Rectifier-Based Solid-State Transformer with Vector Refactoring Technology in αβ Frame

  • Wong, Hui;Huang, Wendong;Yin, Li
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.487-496
    • /
    • 2019
  • For a solid-state transformer (SST), some factors, such as signal delay, switching loss and differences in the system parameters, lead to unbalanced DC-link voltages among the cascaded H-bridges (CHB). With a control method implemented in the ${\alpha}{\beta}$ frame, the DC-link voltages are balanced, and the reactive power is equally distributed among all of the H-bridges. Based on the ${\alpha}{\beta}$ frame control, the system can achieve independent active current and reactive current control. In addition, the control method of the high-voltage stage is easy to implement without decoupling or a phase-locked loop. Furthermore, the method can eliminate additional current delays during transients and get the dynamic response rapidly without an imaginary current component. In order to carry out the controller design, the vector refactoring relations that are used to balance DC-link voltages are derived. Different strategies are discussed and simulated under the unbalanced load condition. Finally, a three-cell CHB rectifier is constructed to conduct further research, and the steady and transient experimental results verify the effectiveness and correctness of the proposed method.

Research on Stress Reduction Model Based on Transformer

  • Xu, Xin;Zhao, Yikun;Zhang, Ruhao;Xu, Tingting
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.12
    • /
    • pp.3943-3959
    • /
    • 2022
  • People are constantly exposed to stress and anxiety environment, which could contribute to a variety of psychological and physical health problems. Therefore, it is particularly important to identify psychological stress in time and to find a feasible and universal method of stress reduction. This research investigated the influence of different music, such as relaxation music and natural rhythm music, on stress relief based on Electroencephalogram signals. Mental arithmetic test was implemented to create a stressful environment. 23 participants performed the mental arithmetic test with and without music respectively, while their Electroencephalogram signal was recorded. The effect of music on stress relief was verified through stress test questionnaires, including Trait Anxiety Inventory (STAI-6) and Self-Stress Assessment. There was a significant change in the stress test questionnaire values with and without music according to paired t-test (p<0.01). Furthermore, a model based on Transformer for stress level classification from Electroencephalogram signal was proposed. Experimental results showed that the method of listening to relaxation music and natural rhythm music achieved the effect of reducing psychological stress and the proposed model yielded a promising accuracy in classifying the Electroencephalogram signal of mental stress.

Optical Current Snesor using Faraday Effect (Faraday 효과를 이용한 광 전류 센서)

  • 김수길
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.97-101
    • /
    • 2002
  • The optical current transformer using Faraday effect is the sensor to measure current that flows in any conductor. This sensor doesn't undergo the magnetic saturation and effect of adjacent conductors. But this senor using bulk-glass sensing element has crucial drawback. It is impossible that the sensor is mounted to conductor without breaking the closed-loop of light or conductor. So we developed the clamp-type optical current transformer and made an experiment.

  • PDF

Design of FIR System and Hilbert Transformer Having Ability of Selecting Filter Length (필터 Length를 가변할 수 있는 FIR 디지털 필터 및 힐버트 변환기의 설계)

  • Kim, Se-Jung;Hwang, Ho-Jung
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.567-570
    • /
    • 1988
  • This paper describes the design of FIR filtering DSP-chip that can be operated without programming. The proposed DSP-chip has not only the improvement of execution time but also selectivity of filter length from N=1 to N=128. Hilbert Transformer can be designed from this chip. FIR filter system is composed of Data memory/Control Unit, external memory and multiplier-accumulator. Data memory/Control Unit is laid out in this paper.

  • PDF

New Switching signal Pattern in AC Chopper (교류초퍼에서 새로운 스위칭 신호패턴)

  • Jang, Do-Hyun;Yeon, Jae-Eul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1267-1269
    • /
    • 2000
  • New switching signal pattern for four switches is proposed to prevent the shortage of PWM ac choppers. In the proposed technique, four signals to four power switches are generated without current transformer, while the conventional technique requires sensing the polarity of input voltage by voltage comparator and checking the direction of input current by the current transformer. The signal circuit built by the proposed technique is simple, and reduces also the switching loss.

  • PDF

Study on the Characteristics of Constant Voltage Transformer for the changes of the circuit parameters (정전압 변압기의 회로정수에 따른 특성 변화에 관한 연구)

  • Joo Hyeong-Gil;Han Jae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.627-629
    • /
    • 2001
  • The constant voltage transformer(CVT) is a voltage regulator that has a high reliability, a good short circuit characteristic, a high input power factor, and a relative immunity to lightning strike. Moreover, this has a good line regulation without a voltage feedback control. In this paper, the characteristics of CVT for the changes of input voltage and other circuit parameters are investigated.

  • PDF

A Study on LLC Resonant Transformer Design with the Winding Method of Automatic Type suitable for LLC Resonant Converter (LLC 공진 컨버터에 적합한 자동화 권선 LLC 공진 변압기 설계에 관한 연구)

  • Bae, Jun-Hyung;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1108-1111
    • /
    • 2019
  • This paper presents the comprehensive transformer design methodology with the winding method of automatic type suitable for LLC resonant converter. The problem with conventional LLC resonant transformer is that it is difficult to implement the winding method of automatic type because all windings are wound in one bobbin. Therefore, the LLC resonant transformer, which is capable of the winding method of automatic type to multiple section bobbin without insulation tape and barrier tape, is proposed in this paper and the design procedure of the proposed LLC resonant transformer is also shown. Modeling and analysis of the proposed LLC resonant transformer using Maxwell 3D simulation tool are described in detail and a protype 150W LLC resonant converter using the proposed LLC resonant transformer manufactured by 3D modelling is also verified through the experimental test.