• 제목/요약/키워드: Without transformer

검색결과 219건 처리시간 0.027초

직접전력변환 방식을 이용한 전압 sag/swell 보상기의 구현 (Implementation of Voltage Sag/Swell Compensator Using Direct Power Conversion Method)

  • 차한주;이대동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1014-1015
    • /
    • 2006
  • In this paper, a new single phase voltage sag/swell compensator using direct power conversion is introduced. A new compensator consists of input/output filter, series transformer and direct at-ac converter, which is a single-phase back-to-back PWM converter without dc-link capacitors. Advantages of the proposed compensator include: simple power circuit by eliminating dc-link electrolytic capacitors and thereby, improved reliability and increased life time of the entire compensator; simple PWM strategy to compensate voltage sag/swell at the same time and reduced switching losses in the ac-ac converter. Further, the proposed scheme is able to adopt simple switch commutation method without requiring complex four-step commutation method commonly required in the direct power conversion. Simulation results are shown to demonstrate the advantages of the new compensator and PWM strategy.

  • PDF

양방향 풀-브릿지 DC-DC 컨버터를 위한 새로운 소프트 스위칭 기법 (A New Soft Switching Technique for Bi-directional Power Flow, Full-bridge DC-DC Converter)

  • 송유진;박석인;정학근;한수빈;정봉만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.251-255
    • /
    • 2005
  • This paper proposes a new soft switching technique for a phase-shift controlled bi-directional DC-DC converter. The described converter employs a low profile high frequency transformer and two active full-bridge converters for bidirectional power flow capability. A new soft switching technique is proposed, which guarantees soft switching over wide range (no load to full load) without any additional circuit components. In the proposed switching scheme, the switch pairs in the diagonal position of the converter each are turned on/off simultaneously by the switching signals with a variable duty ratio depending on the phase shift amount, and the converter is operated without freewheeling interval.

  • PDF

섬유 보강 복합레진의 섬유 방향이 중합수축에 미치는 영향 (EFFECT OF FIBER DIRECTION ON THE POLYMERIZATION SHRINKAGE OF FIBER-REINFORCED COMPOSITES)

  • 염중원;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제34권4호
    • /
    • pp.364-370
    • /
    • 2009
  • 본 연구의 목적은 strain gage와 LVDT (linear variable differential transformer) 변위센서를 이용하여 섬유 보강 복합레진에서 섬유의 방향이 복합레진의 중합수축에 미치는 영향을 알아보기 위함이다. 지름 10 mm, 높이 2 mm의 원반 모양 유동성 복합레진 (Aeliteflo A2, Bisco, Inc., IL, USA) 중앙에 유리섬유 (X-80821P Glass Fiber, Bisco, Inc., IL, USA)를 위치시키고, 섬유가 배열된 장축 방향 (longitudinal)과 수직방향 (transversal)의 중합수축량을 strain gage (Linear S-series 350${\Omega}$, CAS, Seoul, Korea)를 이용하여 각각 측정하였다. 사용된 유동성 복합레진 자체의 free 중합수축을 구하기 위해 지름 7 mm, 높이 1 mm의 원반 모양 시편의 수직 방향 (axial) free 중합수축값을 LVDT로 측정하였다. 중합된 시편들을 절단하여 주사전자현미경으로 복합 레진 내부의 섬유배열을 관찰하고 각 군에서 측정된 평균 수축값들을 ANOVA로 비교하였고 Scheffe post-hoc test로 사후 검정하였다 (${\alpha}$=0.05). 섬유가 배열된 평면 상에서 복합레진의 중합수축 (radial shrinkage)은 섬유와 평행한 방향에서 감소하고 섬유와 수직한 방향에서 증가했다 (p<0.05). 본 연구의 결과 섬유 보강 복합레진으로 스플린트나 수복물을 제작할 때 중합수축량은 보강된 섬유의 배열방향에 따라 큰 차이가 남을 알 수 있었다.

수중 아-크 방전음원에 관한 연구 (ARC Discharge Sound Source in Underwater)

  • 장재환;장지원
    • 수산해양기술연구
    • /
    • 제21권1호
    • /
    • pp.12-18
    • /
    • 1985
  • 고압변압기의 1차측을 제어하고 2차측에 유도된 전압을 이용한 수중방전음원의 전기음향학적 제특성을 분석.검사한 결과는 다음과 같다. 1. 방전시 2차측 전류는 초기에는 Ohm 법칙을 따르다가 전류가 최고 6.3A 흘러 절연 파괴되었으며, 그 순간 방전음이 생성되었다. 2. 전류인가점과 방전음 생성문의 시간차는 약 3ms였으며, 전압이 최고일 때 절연파괴가 일어나 방전음이 생성되었다. 3. 전극의 끝이 뾰족할수록 2차측 전압이 높을수록 음압수준은 높았다. 4. 뾰족한 형태의 전극은 전극간격이 100cm일 때도 방전이 일어났으며 전극간격이 1cm이상부터 비교적 안정된 방전음이 생성되었다. 5. 방전음의 펄스폭은 약 0.15ms인 Shock Wave였으며, 10HKz 이하의 합성저주파 성분이었다.

  • PDF

High Efficiency Active Clamp Forward Converter with Synchronous Switch Controlled ZVS Operation

  • Lee Sung-Sae;Choi Seong-Wook;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • 제6권2호
    • /
    • pp.131-138
    • /
    • 2006
  • An active clamp ZVS PWM forward converter using a secondary synchronous switch control is proposed in this paper. The proposed converter is suitable for low-voltage and high-current applications. The structure of the proposed converter is the same as a conventional active clamp forward converter. However, since it controls the secondary synchronous switch to build up the primary current during a very short period of time, the ZVS operation is easily achieved without any additional conduction losses of magnetizing current in the transformer and clamp circuit. Furthermore, there are no additional circuits required for the ZVS operation of power switches. Therefore, the proposed converter can achieve high efficiency with low EMI noise, resulting from soft switching without any additional conduction losses, and shows high power dens~ty, a result of high efficiency, and requires no additional components. The operational principle and design example are presented. Experimental results demonstrate that the proposed converter can achieve an excellent ZVS performance throughout all load conditions and demonstrates significant improvement in efficiency for the 100W (5V, 20A) prototype converter.

Three-Phase Four-Wire Inverter Topology with Neutral Point Voltage Stable Module for Unbalanced Load Inhibition

  • Cai, Chunwei;An, Pufeng;Guo, Yuxing;Meng, Fangang
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1315-1324
    • /
    • 2018
  • A novel three-phase four-wire inverter topology is presented in this paper. This topology is equipped with a special capacitor balance grid without magnetic saturation. In response to unbalanced load and unequal split DC-link capacitors problems, a qusi-full-bridge DC/DC topology is applied in the balance grid. By using a high-frequency transformer, the energy transfer within the two split dc-link capacitors is realized. The novel topology makes the voltage across two split dc-link capacitors balanced so that the neutral point voltage ripple is inhibited. Under the condition of a stable neutral point voltage, the three-phase four-wire inverter can be equivalent to three independent single phase inverters. As a result, the three-phase inverter can produce symmetrical voltage waves with an unbalanced load. To avoid forward transformer magnetic saturation, the voltages of the primary and secondary windings are controlled to reverse once during each switching period. Furthermore, an improved mode chosen operating principle for this novel topology is designed and analyzed in detail. The simulated results verified the feasibility of this topology and an experimental inverter has been built to test the power quality produced by this topology. Finally, simulation results verify that the novel topology can effectively improve the inhibition of an inverter with a three-phase unbalanced load while decreasing the value of the split capacitor.

전력용 변압기의 유중가스 해석을 위한 지능형 진단 알고리즘 개발 (Development of Artificial Diagnosis Algorithm for Dissolved Gas Analysis of Power Transformer)

  • 임재윤;이대종;이종필;지평식
    • 조명전기설비학회논문지
    • /
    • 제21권7호
    • /
    • pp.75-83
    • /
    • 2007
  • 일반적으로 변압기의 고장진단을 위해 IEC 코드법이 사용되지만, 이 방법은 가스비율이 규정된 범위 내에 존재하지 않거나 경계조건에 있는 경우 숙련된 진단 전문가에게 의뢰하지 않고는 정확한 고장의 원인을 판정하는데 어려움이 있다. 이러한 문제점을 해결하기 위하여 본 논문에서는 SOM을 이용한 전력용 변압기의 고장진단 알고리즘을 제안한다. 제안된 방법은 훈련 데이터의 경쟁학습을 통하여 자기 구성 맵을 구축한 후, 실증 데이터를 구축된 맵에 적용하여 고장의 진단이 이루어진다. 또한 클러스터링 기법에 의해 구축된 정상/고장모델과 정상 데이터를 비교함으로써 고장의 추이 및 열화정도를 분석한다. 제안된 방법의 유용성을 보이기 위한 실험결과에서 기존의 방법들에 비해 향상된 진단결과를 보임을 확인할 수 있었다.

선박용 변압기 없는 40W LED 조명 구동회로의 설계 및 구현 (Design and Implementation of Transformerless 40W LED Light Driver Circuit for Ships)

  • 송종관;박장식;윤병우
    • 한국전자통신학회논문지
    • /
    • 제7권3호
    • /
    • pp.485-490
    • /
    • 2012
  • 본 논문에서는 선박의 진동에 의하여 수명이 짧은 필라멘트를 사용하는 조명기구를 대체하기 위하여 선박용 LED 조명등 구동회로를 설계 및 구현하였다. 구동회로는 부피를 줄이고 비용을 절감하기 위하여 변압기가 없는 스위칭 회로로 설계되었다. 스위칭 회로는 입력 교류전압 220 V에 PWM 제어를 함으로써 안정적으로 LED를 구동할 수 있도록 설계하였다. 스위칭 회로의 펄스성 전류에 대하여 Valley-fill 방식의 역률 보상회로를 채용함으로써 역률를 개선하였다. 장기간 운항하는 선박에서의 조명등 교체 주기를 줄여 관리를 효율적으로 할 수 있도록 직병렬 배열로 LED 모듈 회로를 설계하여 LED의 일부가 손상되더라도 LED 모듈이 조명등 기능을 할 수 있도록 하였다. 개발한 구동회로를 포함한 조명기구는 전력소모와 역률이 각각 39 W, 0.925 로 선박 조명에 적합함을 확인하였다.

$Pd_{(1-x)}$$Cd_x$[(Mn, Sb), Zr, $Ti]O_3$ 세라믹스의 소결 거동 및 압전 특성에 대한 연구 (The Study of Sintering Behavior and Piezoelectric Properties in $Pd_{(1-x)}$$Cd_x$[(Mn, Sb), Zr, $Ti]O_3$ Ceramics)

  • 나은상;최성철
    • 한국세라믹학회지
    • /
    • 제37권4호
    • /
    • pp.395-401
    • /
    • 2000
  • In this study, we chose the basic composition which indicated the best electrical properties by change of x content(0, 0.05, 0.1, 0.15, 0.2, 0.25 mol respectively) in xPb(Mn1/3Sb2/3)O3-(1-x)Pb(Zr0.52Ti0.48)O3 ceramics. And we substituted Cd2+ for Pb2+ site, then observed the sintering behavior, microstructure and electrical propertties according to the various sintering temperature. The basic composition was the 0.05PMS-0.95PZt, and it showed single perovskite phase and excellent properties. In case of Cd2+ substitution, we were able to sinter at 90$0^{\circ}C$ which was lower than conventional sintering temperature(1200~130$0^{\circ}C$). Especially, when the 2mol% substituted PMS-PZT specimens were sintered at 90$0^{\circ}C$ for 2h, we obtained the p=7.6g/㎤, kp=56%, Qm=520 and made sure of a position of Cd2+ substitution by observing lattice parameter, phase transition temperature. From this results, we could infer that because Cd2+ substituted fro A-site, low temperature sintering of Cd2+ substituted PMS-PZT without any loss of electrical properties shows its applicability for the piezoelectric ceramic transformer.

  • PDF

분산전원 연계선로에서 지락고장시 중성선의 과전류 해석 및 보호계전기의 새로운 알고리즘 (An Overcurrent Analysis in Neutral Line and Algorithm to Prevent Malfunction of Relay in Distributed Generations)

  • 신동열;김동명;차한주
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1916-1922
    • /
    • 2009
  • Introducing distributed generators(DGs) to utility distribution system can cause malfunction of relay on the grid when ground faults or severe load unbalances are occurred on the system. Because DGs interconnected to the grid can contribute fault currents and make bidirectional power flows on the system, fault currents from DGs can cause an interference of relay operation. A directional over current relay(DOCR) can determine the direction of power flow whether a fault occurs at the source side or load side through detecting the phases of voltage and current simultaneously. However, it is identified in this paper that the contributed fault current(Ifdg) from the ground source when was occurred to contribute single-line-to-ground(SLG) fault current, has various phases according to the distances from the ground source. It means that the directionality of Ifdg may not be determined by simply detecting the phases of voltage and current in some fault conditions. The magnitude of Ifdg can be estimated approximately as high as 3 times of a phase current and its maximum is up to 2,000 A depending on the capacity of generation facilities. In order to prevent malfunction of relay and damage of DG facilities from the contribution of ground fault currents, Ifdg should be limited within a proper range. Installation of neutral ground reactor (NGR) at a primary neutral of interconnection transformer was suggested in the paper. Capacity of the proposed NGR can be adjusted easily by controlling taps of the NGR. An algorithm for unidirectional relay was also proposed to prevent the malfunction of relay due to the fault current, Ifdg. By the algorithm, it is possible to determine the directionality of fault from measuring only the magnitude of fault current. It also implies that the directionality of fault can be detected by unidirectional relay without replacement of relay with the bidirectional relay.