• Title/Summary/Keyword: Wires

Search Result 1,515, Processing Time 0.024 seconds

Rapid canine retraction in a Class II bialveolar protrusion case using a lingually extended distraction screw (제II급 치조 전돌 환자에서 설측 견인 장치를 이용한 급속 견치 견인술)

  • Ahn, Kwang-Seok;Joo, Euk;Park, Ju-Young;Ryu, Young-Kyu;Cha, In-Ho;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.308-320
    • /
    • 2006
  • Rapid canine retraction, first introduced by Liou, is a distraction osteogenesis applied to the periodontal ligament tissue. Rapid tooth movement was facilitated by establishing minimal bony resistance on the distal surface of the canine by socket preparation and by osteogenesis on the mesial side in response to the periodontal distraction. Since undesired buccal tipping or extrusion of the canine during retraction tends to occur, it is crucial to maintain the firm path of movement and the axis of the canine during retraction. In order to improve the predictability of the canine movement, lingually extended distraction screws with heavy labial guiding wires were designed. Prefabricated plastic canine models for the estimation of socket depth and miniscrew implants for anchorage reinforcement were also devised. Applying these devices to a female patient with Class II anterior protrusion, the whole treatment was effectively finished in 13 months. Loss of vitality or periodontal problems did not occur throughout treatment, and stable occlusion was maintained during 10 months of retention. This case report demonstrates that a predictable rapid canine retraction can be achieved through the use of this modified technique.

A study on the effect of the magnitude of the gable bends on the tooth movement pattern during on-masse space closure in the maxillary dentition (상악전치 후방 견인시 견인 loop후방에 부여한 gable bend 양에 따른 치아이동 양상에 관한 연구)

  • Chun, Youn-Sic;Row, Joon;Jung, Sang-Hyuk;Kim, Hui-Jung
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.33-45
    • /
    • 2004
  • The purpose of this experimental study was to determine appropriate magnitude of the Gable bends to produce maximum retraction of the anterior teeth. The Calorific Machine was used to illustrate the tooth movement in three dimension. The experimental teeth except the first premolar were embedded in the artificial alveolar bone part. In a series of experiments, the extraction space was closed using arch wires with bull loops into which the gable bends of $10^{\circ},\;20^{\circ},\;30^{\circ}$ degrees were incorporated. The experiments were repeated three times for each degree of the gable bend. Before and after the space closure, radiographs were taken in the sagittal and occlusal directions using occlusal films. Analysis of variance and Scheffe post hoc test were used to determine significant differences among the three groups. The following results were obtained. 1. As magnitudes of the gable bends increased, more bodily anterior tooth movement was seen and the distance of retraction also increased. 2. As magnitudes of the gable bends increase, the amount of posterior tooth protraction decreased while intrusive and buccal movement increased. 3. The arch was coordinated by distal-in rotation of the canine and mesial-in rotation of the second premolar adjacent to the extraction space.

A New Study of Sensing and Optimum Preparation Conditions of Graphite/Different Paper Sensors for Composite Materials (복합재료용 흑연/종이 센서의 최적제조조건 및 감지능 평가 연구)

  • Park, Ha-Seung;Shin, Pyeong-Su;Kim, Jong-Hyun;Baek, Yeong-Min;Park, Joung-Man
    • Composites Research
    • /
    • v.31 no.2
    • /
    • pp.51-56
    • /
    • 2018
  • A new study was carried out to utilize a pencil drawing paper sensor (PDPS), which drew a line using a pencil on the paper, as a sensor. The sensing effect on 3 different papers based on the properties of PDPS was compared. The specimens were prepared by drawing 4B pencils on plain (A4), Hwasun, and Han papers. The silver paste was used to give good electrical contacts of the copper wires and the pencil drawn line. The chemical structures of 3 papers for PDPS by FT-IR spectrum analysis were similar and the comparative compact states of each paper were observed by optical microscope. From statistical evaluation of tensile strength using 3 papers, plain paper was chosen to be best for the PDPD. The optimum drawing number of PDPD was determined by changing the thickness of the paper with the drawing number. Electrical resistance (ER) with graphite on 3 different papers were compared. The changes in compression was observed through cyclic compressive test of composite materials, it was possible to predict the degree of strain sensing under compressive test. It leads to expectation of properties.

Kirschner Wire Fixation for the Treatment of Comminuted Zygomatic Fractures

  • Kang, Dai-Hun;Jung, Dong-Woo;Kim, Yong-Ha;Kim, Tae-Gon;Lee, JunHo;Chung, Kyu Jin
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.3
    • /
    • pp.119-124
    • /
    • 2015
  • Background: The Kirschner wire (K-wire) technique allows stable fixation of bone fragments without periosteal dissection, which often lead to bone segment scattering and loss. The authors used the K-wire fixation to simplify the treatment of laborious comminuted zygomatic bone fracture and report outcomes following the operation. Methods: A single-institution retrospective review was performed for all patients with comminuted zygomatic bone fractures between January 2010 and December 2013. In each patient, the zygoma was reduced and fixed with K-wire, which was drilled from the cheek bone and into the contralateral nasal cavity. For severely displaced fractures, the zygomaticofrontal suture was first fixated with a microplate and the K-wire was used to increase the stability of fixation. Each wire was removed approximately 4 weeks after surgery. Surgical outcomes were evaluated for malar eminence, cheek symmetry, K-wire site scar, and complications (based on a 4-point scale from 0 to 3, where 0 point is 'poor' and 3 points is 'excellent'). Results: The review identified 25 patients meeting inclusion criteria (21 men and 4 women). The mean age was 52 years (range, 15-73 years). The mean follow up duration was 6.2 months. The mean operation time was 21 minutes for K-wire alone (n=7) and 52 minutes for K-wire and plate fixation (n=18). Patients who had received K-wire only fixation had severe underlying diseases or accompanying injuries. The mean postoperative evaluation scores were 2.8 for malar contour and 2.7 for K-wire site scars. The mean patient satisfaction was 2.7. There was one case of inflammation due to the K-wire. Conclusion: The use of K-wire technique was associated with high patient satisfaction in our review. K-wire fixation technique is useful in patient who require reduction of zygomatic bone fractures in a short operating time.

Double Frequency Forcing of the Laminar Separated Flow over a Backward-Facing Step (층류박리 후향계단 유동의 이중주파수 가진)

  • Kim, Sung-Wook;Choi, Hae-Cheon;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1023-1032
    • /
    • 2003
  • The effect of local forcing on the separated flow over a backward-facing step is investigated through hot-wire measurements and flow visualization with multi-smoke wires. The boundary layer upstream of the separation point is laminar and the Reynolds number based on the free stream velocity and the step height is 13800. The local forcing is given from a slit located at the step edge and the forcing signal is always defined when the wind tunnel is in operation. In case of single frequency forcing, the streamwise velocity and the reattachment length are measured under forcing with various forcing frequencies. For the range of 0.010〈S $t_{\theta}$〈0.013, the forcing frequency component of the streamwise velocity fluctuation grows exponentially and is saturated at x/h = 0.75 , while its subharmonic component grows following the fundamental and is saturated at x/h = 2.0. However, the saturated value of the subharmonic is much lower than that of the fundamental. It is observed that the vortex formation is inhibited by the forcing at S $t_{\theta}$ = 0.019 . For double frequency forcing, natural instability frequency is adopted as a fundamental frequency and its subharmonic is superposed on it. The fundamental frequency component of the streamwise velocity grows exponentially and is saturated at 0.5 < x/h < 0.75, while its subharmonic component grows following the fundamental and is saturated at x/h= 1.5 . Furthermore, the saturated value of the subharmonic component is much higher than that for the single frequency forcing and is nearly the same or higher than that of the fundamental. It is observed that the subharmonic component does not grow for the narrow range of the initial phase difference. This means that there is a range of the initial phase difference where the vortex parring cannot be enhanced or amplified by double frequency forcing. In addition, this effect of the initial phase difference on the development of the shear layer and the distribution of the reattachment length shows a similar trend. From these observations, it can be inferred that the development of the shear layer and the reattachment length are closely related to the vortex paring.

Fracture resistance of ceramic brackets to arch wire torsional force (토오크 양에 따른 세라믹 브라켓의 파절 저항성)

  • Han, Jung-Heum;Chang, Minn-Hii;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.37 no.4
    • /
    • pp.293-304
    • /
    • 2007
  • The purpose of this study was to estimate the fracture resistance of commercially available ceramic brackets to torsional force exerted from arch wires and to evaluate the characteristics of bracket fracture. Methods: Lingual root torque was applied to maxillary central incisor brackets with 0.022-inch slots by means of a $022\;{\times}\;028-inch$ stainless steel arch wire. A custom designed apparatus that attached to an Instron was used to test seven types of ceramic brackets (n = 15). The torque value and torque angle at fracture were measured. In order to evaluate the characteristics of failure, fracture sites and the failure patterns of brackets were examined with a Scanning Electron Microscope. Results: Crystal structure and manufacturing process of ceramic brackets had a significant effect on fracture resistance. Monocrystalline alumina (Inspire) brackets showed significantly greater resistance to torsional force than polycrystalline alumina brackets except InVu. There was no significant difference in fracture resistance during arch wire torsional force between ceramic brackets with metal slots and those without metal slots (p > 0.05). All Clarity brackets partially fractured only at the incisal slot base and the others broke at various locations. Conclusion: The fracture resistance of all the ceramic brackets during arch wire torsion appears to be adequate for clinical use.

Synthesis and Characterization of The Electrolessly Deposited Co(Re,P) Film for Cu Capping Layer (무전해 도금법으로 제조된 Co(Re,P) capping layer제조 및 특성 평가)

  • Han, Won-Kyu;Kim, So-Jin;Ju, Jeong-Woon;Cho, Jin-Ki;Kim, Jae-Hong;Yeom, Seung-Jin;Kwak, Noh-Jung;Kim, Jin-Woong;Kang, Sung-Goon
    • Korean Journal of Materials Research
    • /
    • v.19 no.2
    • /
    • pp.61-67
    • /
    • 2009
  • Electrolessly deposited Co (Re,P) was investigated as a possible capping layer for Cu wires. 50 nm Co (Re,P) films were deposited on Cu/Ti-coated silicon wafers which acted as a catalytic seed and an adhesion layer, respectively. To obtain the optimized bath composition, electroless deposition was studied through an electrochemical approach via a linear sweep voltammetry analysis. The results of using this method showed that the best deposition conditions were a $CoSO_4$ concentration of 0.082 mol/l, a solution pH of 9, a $KReO_4$ concentration of 0.0003 mol/l and sodium hypophosphite concentration of 0.1 mol/L at $80^{\circ}C$. The thermal stability of the Co (Re,P) layer as a barrier preventing Cu was evaluated using Auger electron spectroscopy and a Scanning calorimeter. The measurement results showed that Re impurities stabilized the h.c.p. phase up to $550^{\circ}C$ and that the Co (Re,P) film efficiently blocked Cu diffusion under an annealing temperature of $400^{\circ}C$ for 1hr. The good barrier properties that were observed can be explained by the nano-sized grains along with the blocking effect of the impurities at the fast diffusion path of the grain boundaries. The transformation temperature from the amorphous to crystal structure is increased by doping the Re.

RELATIONSHIP OF THE BACTERIA INHIBITING PLAQUE FORMATION AND THE NUMBER OF ORAL BACTERIA (치태형성 억제세균과 구강내 세균수와의 관계)

  • Yang, Kyu-Ho;Chung, Hyun-Ju;Oh, Jong-Suk
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.459-465
    • /
    • 1999
  • The inhibition degree of the isolated bacteria on plaque formation of Streptococcus mutans, and the effect of these bacterial genus on the concentration of total bacteria in saliva were assessed with the following. The effectiveness of the isolated bacteria on the inhibition of plaque formation was assessed culturing Streptococcus mutans in the beaker with orthodontic wires. The mean weight of plaque produced on a wire was 152mg in the culture of Streptococcus mutans only, whereas being reduced to 4mg, 78mg, or 72mg in the combined culture of Streptococcus mutans and Enterococcus durans, Lactobacillus acidophilus, or Streptococcus oralis. The colony forming units (CFU) of Streptococcus mutans were $3.6{\times}10^8$ per ml in the culture of Streptococcus mutans, only, wheras being $1.4{\times}10^6,\;5.6{\times}10^6,\;or\;3.8{\times}10^6$ per ml in the combined culture of Streptococcus mutans and Enterococcus durans, Lactobacillus acidophilus, or Streptococcus oralis. When saliva from children was inoculated on brain heart infusion agar, the colony forming units of bacteria were $4.8{\times}10^6\;to\;1.3{\times}10^9$ per ml of saliva. The concentration of Enterococcus, Lactobacillus, or Streptococcus inhibiting Streptococcus mutans in saliva was not proportioned to that of total bacteria replicated on brain heart infusion agar. These results indicate that the isolated bacteria inhibited the replication of Streptococcus mutans, resulting into inhibiting the formation of plaque, but the concentration of Enterococcus, Lactobacillus, or Streptococcus inhibiting Streptococcus mutans, in saliva might not affect the total bacterial concentration of saliva.

  • PDF

FACTORS INFLUENCING THE FORMATION OF INSOLUBLE GLUCAN BY STREPTOCOCCUS SOBRINUS (Streptococcus sobrinus의 비수용성 글루캔 합성에 영향을 미치는 인자)

  • Chung, Jin;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.90-97
    • /
    • 2000
  • There are various kinds of factors associated with the formation of dental plaque in oral cavity such as nutrient molecules and chemical agents. The factors influencing the formation of insoluble glucan by Streptococcus sobrinus and its replication were examined on orthodontic wires. The results were as follows: 1. Insoluble glucan was well produced in the media initially adjusted at pH 7.0 than pH 5.5 or pH 8.5 like bacterial replication. 2. The synthesis of insoluble glucan and bacterial replication were significantly increased in the media containing 2.5% yeast extract. The formation of insoluble glucan was inhibited by 10 folds in the media containing 20% of sucrose than 1.25%, but the replication of bacteria was increased by 20 folds. 3. Insoluble glucan was significantly formed at a concentration of 1.0mM of calcium chloride, 40mM of potassium chloride, 0.1mM of magnesium chloride, while the replication of bacteria was little influenced by them regardless their concentration. 4. The formation of insoluble glucan and bacterial replication were significant in the media containing 10mM of sodium bicarbonate, but both were completely inhibited at 100mM or above. The production of insoluble glucan and the bacterial replication were largely decreased at 10mM of Tris while insoluble glucan was formed in abundance at 100mM of Tris. 5. The synthesis of insoluble glucan and the bacterial replication were inhibited at 10mM or above of sodium phosphate and potassium phosphate.

  • PDF

PHYSICAL PROPERTIES OF VAR10US BRANDS OF ELASTOMERIC CHAINS (수종의 합성 고무탄성재의 성질에 관한 연구)

  • Kim, Kyung-Ho;Hwang, Chung-Ju;Sung, Sang-Jin
    • The korean journal of orthodontics
    • /
    • v.27 no.6 s.65
    • /
    • pp.943-954
    • /
    • 1997
  • Forces needed for orthodontic tooth movement are obtained from various appliances such as orthodontic wires or elastic rubber. Orthodontic elastic rubber is widely used clinically, but permanent deformation and force decay may occur from the environmental changes, time of clinical use and the extent of the stretch, making the Prediction of force being applied difficult. The Present study examined and compared the changes in residual force between three brands of elastomeric chains (Ormco Generation II Power Chains ; brand A, RMO : Energy-Chain ; brand B, Unitek : AlastiK ; brand C) under various environmental conditions, amount of initial force, types of elastomer and the rate of extension. The characteristic physical properies of the elastomeric chains were as follows. 1. In all three brands, the residual force ratio was largest when the chains were stored in air, with no difference between water and saliva. 2. In all three brands, after 24 hours, there was no statistical difference in residual force ratio according to the initial force level. 3. In Brand A and B, the presence of filament had no correlation with the residual force ratio. In Brand C force decay was more severe when the chain contained filament. 4. In each brand, rate of extension had no effect on residual force ratio. 5. Brand B showed relatively higher residual force ratio compared to other brands.

  • PDF