• Title/Summary/Keyword: Wires

Search Result 1,515, Processing Time 0.034 seconds

Magnetic Resonance and Electromagnetic Wave Absorption of Metamaterial Absorbers Composed of Split Cut Wires in THz Frequency Band (THz 대역에서 Cut Wire로 구성된 메타소재의 자기공진 및 전파흡수특성)

  • Ryu, Yo-Han;Kim, Sung-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.2
    • /
    • pp.49-53
    • /
    • 2017
  • Metamaterials composed of split cut wire (SCW) on grounded polyimide film substrate have been investigated for the aim of electromagnetic wave absorbers operated in THz frequency band. Reflection loss and current density distributions are numerically simulated with variations of the SCW geometries using the commercial software. The minimum reflection loss lower than -20 dB has been identified at 5.5~6.5 THz. The simulated resonance frequency and reflection loss can be explained on the basis of the circuit theory of an inductance-capacitance (L-C) resonator. Dual-band absorption can be obtained by arrangement of two SCWs of different length on the top layer of the grounded substrate, which is due to multiple magnetic resonances by scaling of SCWs. With increasing the side spacing between SCWs, a more enhanced absorption peak is observed at the first resonance frequency that is shifted to a lower frequency.

Vibration control of small horizontal axis wind turbine blade with shape memory alloy

  • Mouleeswaran, Senthil Kumar;Mani, Yuvaraja;Keerthivasan, P.;Veeraragu, Jagadeesh
    • Smart Structures and Systems
    • /
    • v.21 no.3
    • /
    • pp.257-262
    • /
    • 2018
  • Vibrational problems in the domestic Small Horizontal Axis Wind Turbines (SHAWT) are due to flap wise vibrations caused by varying wind velocities acting perpendicular to its blade surface. It has been reported that monitoring the structural health of the turbine blades requires special attention as they are key elements of a wind power generation, and account for 15-20% of the total turbine cost. If this vibration problem is taken care, the SHAWT can be made as commercial success. In this work, Shape Memory Alloy (SMA) wires made of Nitinol (Ni-Ti) alloys are embedded into the Glass Fibre Reinforced Polymer (GFRP) wind turbine blade in order to reduce the flapwise vibrations. Experimental study of Nitinol (Ni-Ti) wire characteristics has been done and relationship between different parameters like current, displacement, time and temperature has been established. When the wind turbine blades are subjected to varying wind velocity, flapwise vibration occurs which has to be controlled continuously, otherwise the blade will be damaged due to the resonance. Therefore, in order to control these flapwise vibrations actively, a non-linear current controller unit was developed and fabricated, which provides actuation force required for active vibration control in smart blade. Experimental analysis was performed on conventional GFRP and smart blade, depicted a 20% increase in natural frequency and 20% reduction in amplitude of vibration. With addition of active vibration control unit, the smart blade showed 61% reduction in amplitude of vibration.

Effects of Tensile Properties and Microstructure on Abrasive Wear for Ingot-Slicing Saw Wire (잉곳 슬라이싱용 Saw Wire의 연삭마모에 미치는 인장특성과 미세조직의 영향)

  • Hwang, Bin;Kim, Dong-Yong;Kim, Hoi-Bong;Lim, Seung-Ho;Im, Jae-Duk;Cho, Young-Rae
    • Korean Journal of Materials Research
    • /
    • v.21 no.6
    • /
    • pp.334-340
    • /
    • 2011
  • Saw wires have been widely used in industries to slice silicon (Si) ingots into thin wafers for semiconductor fabrication. This study investigated the microstructural and mechanical properties, such as abrasive wear and tensile properties, of a saw wire sample of 0.84 wt.% carbon steel with a 120 ${\mu}M$ diameter. The samples were subjected to heat treatment at different linear velocities of the wire during the patenting process and two different wear tests were performed, 2-body abrasive wear (grinding) and 3-body abrasive wear (rolling wear) tests. With an increasing linear velocity of the wire, the tensile strength and microhardness of the samples increased, whereas the interlamellar spacing in a pearlite structure decreased. The wear properties from the grinding and rolling wear tests exhibited an opposite tendency. The weight loss resulting from grinding was mainly affected by the tensile strength and microhardness, while the diameter loss obtained from rolling wear was affected by elongation or ductility of the samples. This result demonstrates that the wear mechanism in the 3-body wear test is much different from that for the 2-body abrasive wear test. The ultra-high tensile strength of the saw wire produced by the drawing process was attributed to the pearlite microstructure with very small interlamellar spacing as well as the high density of dislocation.

Characteristics of HFIX Insulated Wire Sheaths Contaminated by Pollutants (오염물질에 따른 HFIX 절연전선 피복의 특성 변화에 관한 연구)

  • Choi, Su-Gil;Nam, Yeong-Jae;Jin, Se-Young;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.8-17
    • /
    • 2020
  • In this study, the characteristics of HFIX insulated wire sheaths contaminated by pollutants were examined. KS C IEC 60811-1-3 standard was followed in performing the water-resistance wire tests. Pollutants were selected, and the specimens were exposed to the pollutants for a maximum duration of four weeks. The maximum tensile load and the elongation rate were measured each week. As the period of pollution exposure increased, the maximum tensile load of the specimens decreased by 6.22% and 6.52% at room temperature and high temperature, respectively, and 19.94% for specimens coated with a rust-proof lubricant. The elongation rate also decreased rapidly, such that the reductions in the properties of the sheath were significant. From the analysis of the surfaces using a scanning microscope, as the contamination period increased, structural changes such as perforation, split, and melting occurred, and the mechanical properties of the specimens decreased. Therefore, it is necessary to develop and follow an inspection cycle and periodically carry out repairs to prevent the deterioration of insulated wires.

Effect of Acetylcholine on Electrical Activity of Cat Stomach (자율신경계에 작용하는 약물이 위장 전기도에 미치는 영향)

  • Kim, Myung-Suk;Park, Hyoung-Jin;Bai, Sun-Ho;Choi, Hyun;Kim, Chul
    • The Korean Journal of Physiology
    • /
    • v.14 no.2
    • /
    • pp.21-28
    • /
    • 1980
  • In order to investigate the effect of cholinergic substance on the electrical and the mechanical activities of the stomach muscle, 10 isolated cat stomachs were studied. At various sites of a stomach muscle preparation, the electrical activity was monopolarly recorded by using capillary electrodes containing chlorided silver wires, and the isometric contractile activity was recorded simultaneously at the terminal portion of the antrum in Krebs solution$(36^{\circ}C)$ which was aerated with a gas mixture consisting of 95% $O_2$ and 5% $CO_2$. The recording of these activities were performed before (control period) and after acetylcholine$(10^{-5}M)$ and atropine $(10^{-6}M)$ administrations serially. Following results were obtained: 1) The mean frequency of the slow wave was $4.36{\pm}0.22\;cycles/min$ at all the various sites of the cat stomach. The slow wave was propagated caudad in sequence and its velosity of propagation increased as the slow wave approached the pylorus in normal Krebs solution. 2) After acetylcholine administration, the frequency of the slow wave increased transiently and the increase of slow wave frequency was followed by the isometric contraction of antral muscle in association with the second potential which succeeded the slow wave. 3) By atropine administration, the stimulatory effect of acetylcholine on the antral muscle contraction was abolished completely, and the frequency of the slow wave decreased significantly compared with that of the control period, which tendency was more prominent in the antrum. The above results suggest that the transient increase in the frequency of gastric slow wave by acetylcholine may have some influence upon the contraction mechanism of the cat antral muscle.

  • PDF

Combined Percutaneous and Minimal on Internal Fixation of Calcaneal Fractures Using Extensile Lateral Approach (광범위 외측 도달법을 이용한 종골 골절의 경피적 및 최소 내고정술)

  • Yu, Sun-O;Kim, Joo-Sung;Kim, Jong-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.2
    • /
    • pp.201-207
    • /
    • 2002
  • Purpose: To present the clinical analysis of the results obtained in 38 cases of displaced intraarticular calcaneal fractures undergone combined percutaneous axial pin fixation of calcaneal body and minimal internal fixation using extensile lateral approach. Materials and Methods: From March 2000 to February 2002, thirty-eight displaced intraarticular fractures of the calcaneus in 35 patients were fixed with 3.5mm cannulated screws and percutaneous 2.5mm K-wires. The extensile lateral approach was used in all cases. The average follow-up period was 16 months. Clinical evaluation was assessed according to the Ankle-Hind Foot Scale of American Orthopedic Foot and Ankle Society. Results: The clinical results were graded as excellent in 8 cases(21%), good in 22 cases(58%), fair in 6 cases(16%), and poor in 2 cases(5%). Two cases of poor result were type IV of Sanders classification. The postoperative reduction status of the articular surface was analyzed by computed tomography in all cases and was found to be less 2mm of step off in 30 cases and between 2 and 4mm in 8 cases. Unsatisfactory results were correlated with severity of articular comminution and failure to obtain accurate reduction of the articular surface. Using early functional postoperative care, all fractures healed without secondary displacement except 1 case on an average of ten weeks. Two cases had superficial necrosis of the wound margins, however, secondary wound healing was uneventful and skin grafting was not needed. Conclusion: Combined minimal internal fixation and percutaneous pin fixation using extensile lateral approach is useful operative method of intraarticular calcaneal fractures because providing enough stability to permit functional aftercare and allowing excellent anatomical reduction. In addition, this method diminishes the risk of lateral soft tissue problems.

  • PDF

A Design of Power Line Communication system using Wavelet OFDM (Wavelet OFDM 기법을 이용한 전력선 통신 시스템 설계)

  • Moon, Ki-Tak;Kim, Joo-Seok;Jang, Dong-Won;Kim, Kyung-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.11C
    • /
    • pp.871-876
    • /
    • 2010
  • Currently the development of powerline communication technology has become possible due to the high-speed communications. But the communication lines used for power line communication, not wires carrying power wiring is because when sending high-frequency wireless communication system unintentionally be influenced. To compensate for these shortcomings by using notch filters to reduce interference has been studied. Wavelet-based OFDM on the other hand by the method has been used to reduce interference. Wavelet-based OFDM has been used in the existing powerline OFDM scheme using FFT instead of the general structure of the CMFB filters to generate a signal. By doing so, subtly signals per frequency band, cut it, is to realize how efficient highways. It brought a deep filter characteristics, a flexible notch filter can be achieved without an external circuit has an advantage. In this paper, Using Wavelet OFDM powerline communication system is designed and presented the results of simulations.

A Very Compact 60 GHz LTCC Power Amplifier Module (초소형 60 GHz LTCC 전력 증폭기 모듈)

  • Lee, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1105-1111
    • /
    • 2006
  • In this paper, using low-temperature co-fired ceramic(LTCC) based system-in-package(SiP) technology, a very compact power amplifier LTCC module was designed, fabricated, and then characterized for 60 GHz wireless transmitter applications. In order to reduce the interconnection loss between a LTCC board and power amplifier monolithic microwave integrated circuits(MMIC), bond-wire transitions were optimized and high-isolated module structure was proposed to integrate the power amplifier MMIC into LTCC board. In the case of wire-bonding transition, a matching circuit was designed on the LTCC substrate and interconnection space between wires was optimized in terms of their angle. In addition, the wire-bonding structure of coplanar waveguide type was used to reduce radiation of EM-fields due to interconnection discontinuity. For high-isolated module structure, DC bias lines were fully embedded into the LTCC substrate and shielded with vias. Using 5-layer LTCC dielectrics, the power amplifier LTCC module was fabricated and its size is $4.6{\times}4.9{\times}0.5mm^3$. The fabricated module shows the gain of 10 dB and the output power of 11 dBm at P1dB compression point from 60 to 65 GHz.

Use of resorbable mesh and fibrin glue for restoration in comminuted fracture of anterior maxillary wall

  • Yang, Jae-Hyuk;Chang, Suk Choo;Shin, Jin Yong;Roh, Si-Gyun;Lee, Nae-Ho
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.3
    • /
    • pp.175-180
    • /
    • 2018
  • Background: The facial bone has a complex structure compared to other bones, and various types of fractures can occur due to its characteristics. Among them, in comminuted fractures of anterior maxillary wall, multiple depressed and impacted bony segments cannot be reduced easily when performing internal fixation using plates and screws or wires, and inadequate restoration leads to a range of complications. This paper introduces an alternative technique using a resorbable mesh with fibrin glue to restore comminuted fractures of anterior maxillary wall. Methods: Thirteen patients were diagnosed with comminuted fractures of anterior maxillary wall between March 2017 and February 2018 in the authors' hospital. All patients with comminuted fractures of anterior maxillary wall underwent restoration using resorbable mesh with fibrin glue. The patients' demographics, causes of facial trauma, mean operation time, length of hospital stay, follow-up period, and complications were recorded. Results: No major complications and only one hypoesthesia of the skin area was noted. Three months after surgery, the hypoesthesia recovered completely. After surgery (mean, 3.9 months; range, 2-12 months), computed tomography showed that the bone fragments in all patients were fixed successfully in their anatomical places. Conclusion: In comminuted fractures of anterior maxillary wall, the use of a resorbable mesh with fibrin glue can be an advantageous and effective method for a successful restoration without complications.

Development and Test of a Cooling System for a 154 kV Superconducting Fault Current Limiter

  • Kim, Heesun;Han, Young Hee;Yang, Seong-Eun;Yu, Seung-Duck;Park, Byung Jun;Park, Kijun;Yoo, Jaeun;Kim, Hye-Rim;In, Sehwan;Hong, Yong Joo;Yeom, Hankil
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.141-144
    • /
    • 2015
  • The superconducting fault current limiter (SFCL) is an electric power device that limits the fault current immediately in a power grid. Korea Electric Power Corporation (KEPCO) has been developing a 154 kV, 2 kA SFCL since 2011 to protect power grids from increasing fault current and improve the stability and quality of electric power. This SFCL adopts 2G YBCO wires and operates at 71 K and 5 bars. In this paper, a cooling system for the 154 kV SFCL and its cooling test results are reported. This cooling system uses a Stirling-type cooler to make sub-cooled liquid nitrogen ($LN_2$), which cools the superconductor modules of the SFCL. The $LN_2$ is circulated between the cooler and the cryostat that contains superconductor modules. The $LN_2$ also plays the role of a high voltage insulator between the modules and the cryostat, so the pressure was maintained at 5 bars for high insulation performance. After installation in a test site, the cooling characteristics of the system were tested. In this operation test, some important data were measured such as temperature distribution in $LN_2$, pressure change, performance of the heat exchanger, and cooling capacity of the total system. Consequently, the results indicate that the cooling system operates well as designed.