• 제목/요약/키워드: Wires

검색결과 1,511건 처리시간 0.025초

FES보행중의 피드백제어를 위한 관절 각도계측 시스템 개발 (Development of Joint Angle Measurement System for the Feedback Control in FES Locomotion)

  • 문기욱;김철승;김지원;이재호;권유리;강동원;강곤;김요한;엄광문
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.203-209
    • /
    • 2009
  • The purpose of this study is to develop a minimally constraint joint angle measurement system for the feedback control of FES (functional electrical stimulation) locomotion. Feedback control is desirable for the efficient FES locomotion, however, the simple on-off control schemes are mainly used in clinic because the currently available angle measurement systems are heavily constraint or cosmetically poor. We designed a new angle measurement system consisting of a magnet and magnetic sensors located below and above the ankle joint, respectively, in the rear side of ipsilateral leg. Two magnetic sensors are arranged so that the sensing axes are perpendicular each other. Multiple positions of sensors attachment on the shank part of the ankle joint model and also human ankle joint were selected and the accuracy of the measured angle at each position was investigated. The reference ankle joint angle was measured by potentiometer and motion capture system. The ankle joint angle was determined from the fitting curve of the reference angle and magnetic flux density relationship. The errors of the measured angle were calculated at each sensor position for the ankle range of motion (ROM) $-20{\sim}15$ degrees (dorsiflexion as positive) which covers the ankle ROM of both stroke patients and normal subjects during locomotion. The error was the smallest with the sensor at the position 1 which was the nearest position to the ankle joint. In case of human experiment, the RMS (root mean square) errors were $0.51{\pm}1.78(0.31{\sim}0.64)$ degrees and the maximum errors were $1.19{\pm}0.46(0.68{\sim}1.58)$ degrees. The proposed system is less constraint and cosmetically better than the existing angle measurement system because the wires are not needed.

구강내에서 임플랜트 지대주 형성 시 내부연결방식과 외부연결방식간의 열전달 효과 비교 (THE COMPARATIVE STUDY OF THERMAL INDUCTIVE EFFECT BETWEEN INTERNAL CONNECTION AND EXTERNAL CONNECTION IMPLANT IN ABUTMENT PREPARATION)

  • 허중보;고석민
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.60-70
    • /
    • 2007
  • Statement of problem: The cement-type abutment would be needed for the reduction of its body in order to correct the axis and to assure occlusal clearance. In the case of intraoral preparation, there is a potential risk that generated heat could be transmitted into the bone-implant interface, where it can cause deterioration of tissues around the implant and failed osseointegration. Purpose: The purpose of this study was to assess the difference of the heat transmitting effect on external and internal connection implant types under various conditions. Material and method: For evaluating the effects of alternating temperature, the thermocoupling wires were attached on 3 areas of the implant fixture surface corresponding to the cervical, middle, and apex. The abutments were removed 1mm in depth horizontally with diamond burs and were polished for 30 seconds at low speed with silicone points using pressure as applied in routine clinical practice. Obtained data were analyzed using Mann-Whitney rank-sum test and Wilcoxon / Kruskal-Wallis Tests. Result: Increased temperature on bone-implant interface was evident without air-water spray coolant both at high speed reduction and low speed polishing (p<.05). But, the difference between connection types was not shown. Conclusion: The reduction procedure of abutment without using proper coolant leads to serious damage of oral tissues around the implant irrespective of external and internal connection type.

2.5 mm2 HIV에 일반화염 및 DC 단락 전류를 인가하여 생성된 기공의 정량적 분포 해석 (Quantitative Distribution of Created Voids by Applying General Flame and DC Short-circuit Current to 2.5 mm2 HIV)

  • 김승삼;최충석
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.38-42
    • /
    • 2013
  • This study performed the quantitative distribution analysis of created voids to an insulator when applying general flame and DC short-circuit current to 2.5 $mm^2$ HIV (600 V Grade Heat-Resistant Polyvinyl Chloride Insulated Wires). The diameter of cross-section of HIV normal product and the radius of conductor were measured to be 3.3 mm and 1.8 mm. The exterior of HIV exposed to general flame showed severe carbonization and its interior exhibited voids created by dechlorination reaction. This study observed the characteristics that, when the shortcircuit current applied for 2 seconds from a DC 12 V lead battery, the conductor and neighboring insulator were melted, causing the insulator adhering to the conductor. On average, 87 voids were created on 10 mm of the HIV. The average diameter of voids was 0.25 mm. In addition, it was found that, when the short-circuit current applied for 4 seconds, the interior of insulator in contact with conductor severely carbonized and showed exfoliation phenomenon. On average, 47 voids were created, with more voids at the bottom. The average diameter of voids was 0.20 mm. When the short-circuit current for 6 seconds, most parts of upper part of conductor was carbonized, 20 voids were created. The average diameter of voids was measured to be 0.24 mm. It could be seen that the created voids received little influence by the type of energy source and the number of created voids was reduced as the energy supply time increased.

En-masse 견인에 의한 발치공간 폐쇄 후 상악치열의 이동양상 -제1소구치 및 제2소구치 발치 비교 (Spatial changes of the upper dentition following en-masse space closure: A comparison between first and second premolar extraction)

  • 김희정;전윤식;정상혁
    • 대한치과교정학회지
    • /
    • 제35권5호
    • /
    • pp.371-380
    • /
    • 2005
  • 제1소구치 또는 제2소구치 발치 후 발치공간 폐쇄 시 치아이동의 양상 즉, 치아이동방향과 이동량을 구명하는 것이 본 연구의 목적이었다. 상악 우측 인공 치조골부에 제1소구치 또는 제2소구치를 제외한 중절치부터 제2대구치 까지 실험용 치아들을 식립하고 bull loop이 형성된 반쪽 호선에 15도의 gable bend를 부여한 후 전치부를 후방견인하여 발츠공간을 폐쇄시켰다. 실험 전후에 교합면 방사선사진과 시상면 방사선사진을 촬영하고 인공치조골부 하단에 식립된 기준표지점에 중첩하여 이동방향 및 이동량을 계측하였다. 그 결과 제2소구치 발치군의 전치부후방이동량이 제1소구치 발치군에 비해 더 적었으며 구치부의 고정원 소실 및 고정원의 근심설측회전량은 제2소구치 발치군에서 더 크게 나타났다.

부착 유지장치의 직, 간접 부착법에 따른 전단 접착력 비교 (Direct and indirect bonding of wire retainers to bovine enamel using three resin systems: shear bond strength comparisons)

  • 권태엽;;;박효상
    • 대한치과교정학회지
    • /
    • 제41권6호
    • /
    • pp.447-453
    • /
    • 2011
  • Objective: We compared the shear bond strength (SBS) of lingual retainers bonded to bovine enamel with three different resins using direct and indirect methods. Methods: Both ends of pre-fabricated twisted ligature wires were bonded to bovine enamel surfaces using Light-Core, Tetric N-Flow, or Transbond XT. Phosphoric acid-etched enamel surfaces were primed with One-Step prior to bonding with Light-Core or Tetric N-Flow. Transbond XT primer was used prior to bonding with Transbond XT. After 24 hours in water at $37^{\circ}C$, we performed SBS tests on the samples. We also assigned adhesive remnant index (ARI) scores after debonding and predicted the clinical performance of materials and bonding techniques from Weibull analyses. Results: Direct bonding produced significantly higher SBS values than indirect bonding for all materials. The SBS for Light-Core was significantly higher than that for Tetric N-Flow, and there was no significant difference between the direct bonding SBS of Transbond XT and that of Light-Core. Weibull analysis indicated Light-Core performed better than other indirectly bonded resins. Conclusions: When the SBS of a wire retainer is of primary concern, direct bonding methods are superior to indirect bonding methods. Light-Core may perform better than Transbond XT or Tetric N-Flow when bonded indirectly.

Pb 함량을 달리한 전구체 분말에서의 Bi-2223/Ag 초전도 테이프의 특성 변화 (Properties of Bi-2223/Ag HTS tapes prepared using powders of varying lead content)

  • 하동우;양주생;황선역;하홍수;오상수;이언용;권영길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.585-588
    • /
    • 2003
  • Bi-2223 superconducting wires were fabricated by stacking, drawing process with different precursor powders and different heat-treatment histories. The precursor powders were 2 kinds of Pb content. And a part of the tapes were experienced pre-annealing process which caused tetragonal structure of Bi-2212 phase to orthorhombic structure of it was during drawing process. We confirmed the transformation of Bi-2212 phase from tetragonal structure to orthorhombic structure and reduction of second phases. AC magnetization analysis were performed in order to investigate the fraction of Bi-2223 phase in Bi-2223/Ag HTS tape. The cross sections of 55 filaments and 61 filaments were investigated after rolled in order to understand deformation mechanism of superconducting cores. We could achieve best Ic of 70 A class at the Bi-2223/Ag tape using low Pb content of precursor powder and experienced pre-annealing process. AC magnetization analysis was useful to investigate the fraction of Bi-2223 phase in the Bi-2223/Ag tape.

  • PDF

Study on Properties of Ag and PbO Doped $YBa_2Cu_3O_x$

  • Son, Dea-Wha;Fan, Zhanguo
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.593-596
    • /
    • 2003
  • A proposed way to prepare $YBa_2Cu_3O_y$ wires or tapes is that Ag is used as substrate and melting point of $YBa_2Cu_3O_y$ is decreased to lower than the melting point of silver ($961\;^{\circ}C$). Therefore after the deposition of $YBa_2Cu_3O_y$ film on Ag substrate, the heat treatment can be carried out below the Ag melting point. Silver (Ag) and Lead oxide(PbO) were selected to be additives for $YBa_2Cu_3O_y$. Different Ag and PbO contents were added in $YBa_2Cu_3O_y$, the melting points of which were measured by DTA. In order to guarantee that the superconductivity of $YBa_2Cu_3O_y$ was not reduced after Ag and PbO added into $YBa_2Cu_3O_y$, their superconductivities were measured. It is proved that as additives, both Ag and PbO can reduce the melting point of $YBa_2Cu_3O_y$. For Ag doped $YBa_2Cu_3O_y$, $T_c$ is about 93K and ${\Delta}Tc$ is $2{\sim}3K$. For PbO doped $YBa_2Cu_3O_y$, $T_c$ is $88K{\sim}92K$ and ${\Delta}T_c$ is $11{\sim}12K$. When 10 wt% of Ag and 10 wt% PbO were added in $YBa_2Cu_3O_y$, the melting point of the mixture of $YBa_2Cu_3O_y$ (80 wt%), Ag (10 wt%) and PbO (l0 wt%) is $943^{\circ}C$. The transition temperatures ($T_c$) of the sample is 91.8 K.

  • PDF

원격제어기반 이동체 감지 및 변형 퍼스널 로봇시스템 설계 및 구현 (Development of Moving Objects Monitoring and Transforming Personal Robot System Based on Remote Controls)

  • 이동명
    • 한국산학기술학회논문지
    • /
    • 제11권1호
    • /
    • pp.159-165
    • /
    • 2010
  • 본 논문에서는 원격제어기반 이동체 감지 및 변형 퍼스널 로봇시스템을 설계 및 구현하고 성능을 분석하였다. 설계에 있어서 중점적으로 고려한 사항은 퍼스널 로봇의 버튼기반 및 원격제어방식 설계, 휠 주행모드/보행모드/자동 주행모드/감시모드의 동작모드 설계, 원격제어기능 설계, 주변환경 변화감지 기능 설계, 모션데이터 추출기법 설계, 장애물 탐지기법 설계이다. 개발한 퍼스널 로봇은 언제 어디서나 원격지에서 인터넷과 접속하여 로봇의 동작 및 영상인식을 제어하여 주변 환경변화를 감지하는 이동체 감지 및 4가지의 변형이 가능하다. 또한 실험결과, 실내의 문턱이나 전선등으로 이루어진 지형의 요철을 다리 관절로 이동 가능하며, 자동 주행모드로 진행 할 경우 30cm*30cm 공간의 장애물 환경에서 3개의 적외선 센서를 이용하여 장애물을 성공적으로 벗어남을 확인하였다.

교정용 와이어의 표면특성에 미치는 TiN 및 ZrN 코팅영향 (Effects of TiN and ZrN Coating on Surface Characteristics of Orthodontic Wire)

  • 김원기;김도영;최한철
    • 한국표면공학회지
    • /
    • 제41권4호
    • /
    • pp.147-155
    • /
    • 2008
  • The dental orthodontic wire provides a good combination of strength, corrosion resistance and moderate cost. The purpose of this study was to investigate the effects of TiN and ZrN coating on corrosion resistance and physical property of orthodontic wire using various instruments. Wires(round type and rectangular type) were used, respectively, for experiment. Ion plating was carried out for wire using Ti and Zr coating materials with nitrogen gas. Ion plated surface of each specimen was observed with field emission scanning electron microscopy(FE-SEM), energy dispersive X-ray spectroscopy(EDS), atomic force microscopy(AFM), vickers hardness tester, and electrochemical tester. The surface of TiN and ZrN coated wire was more smooth than that of other kinds of non-coated wire. TiN and ZrN coated surface showed higher hardness than that of non-coated surface. The corrosion potential of the TiN coated wire was comparatively high. The current density of TiN coated wire was smaller than that of non-coated wire in 0.9% NaCl solution. Pit nucleated at scratch of wire. The pitting corrosion resistance $|E_{pit}-E_{rep}|$ increased in the order of ZrN coated(300 mV), TiN coated(120 mV) and non-coated wire(0 mV).

다른 형태를 가진 2소자 프린트 안테나의 방사특성에 관한 연구 (A Study of the Radiation Characteristics of Novel Printed Antenna Composed of Dual Elements with Different Shape)

  • 이채봉;김정현
    • 융합신호처리학회논문지
    • /
    • 제9권2호
    • /
    • pp.141-145
    • /
    • 2008
  • 길이가 서로 다른 평행선로에 전류가 흐르는 경우, 커먼모드 전류(Common mode current)에 의한 전자파의 방사가 일어난다. 이러한 방사 원리를 이용하여 경량, 소형의 길이가 다른 2소자 선형 안테나가 제안되어 있다. 그러나 이 안테나의 경우 선으로 결합된 구조를 가지기 때문에 제작에 있어서 많은 제약이 따른다. 본 논문에서는 선형 안테나의 단점을 개선하고, 제작과 설계가 용이한 평면 기판에 길이가 다른 2소자 평면 안테나를 설계하고, 광대역(UWB: Ultra Wide Band)의 특성을 가지는 안테나를 설계하였다. 그리고 안테나 소자에 삼각형 패치 S, 노치, 테이퍼를 설계함으로서 방사특성은 다이 폴 안테나와 비슷하나 보다 넓은 대역에서 동작하는 안테나를 제작 할 수 있었다. 그 결과 비대역($VSWR{\le}2$)이 약 58%가 되었다.

  • PDF