• Title/Summary/Keyword: Wires

Search Result 1,509, Processing Time 0.026 seconds

Fatigue Life Prediction for Electric Railway Catenary wires (가선재의 피로수명 예측)

  • Kim, Yong-Ki;Chang, Se-Ky
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.558-567
    • /
    • 2003
  • The catenary wires are damaged by periodic running of train as well as repeated stress. The wires are also degraded by atmosphere corrosion at fields. Corrosion of wires increased surface roughness and deteriorated mechanical properties by providing fatigue crack initiation sited resulting in a bad effect on service life of the wires. Fatigue test of catenary wires performed to estimate service lifetime. Also, simulation to analyze stress on catenary wires was conducted through modelling the finite elements for dynamic behaviors of wires. Fatigue life of catenary wires was estimated with fatigue and simulation tests.

  • PDF

Comparison of frictional forces between aesthetic orthodontic coated wires and self-ligation brackets

  • Kim, Yunmi;Cha, Jung-Yul;Hwang, Chung-Ju;Yu, Hyung Seog;Tahk, Seon Gun
    • The korean journal of orthodontics
    • /
    • v.44 no.4
    • /
    • pp.157-167
    • /
    • 2014
  • Objective: The purpose of this study was to evaluate the clinical efficacy of polymer- and rhodium-coated wires compared to uncoated wires by measuring the frictional forces using self-ligation brackets. Methods: 0.016-inch nickel titanium (NiTi) wires and $0.017{\times}0.025$-inch stainless steel (SS) wires were used, and the angulations between the brackets and wires were set to $0^{\circ}$, $5^{\circ}$, and $10^{\circ}$. Upper maxillary premolar brackets (Clippy-C$^{(R)}$) with a 0.022-inch slot were selected for the study and a tensile test was performed with a crosshead speed of 5 mm/min. The maximum static frictional forces and kinetic frictional forces were recorded and compared. Results: The maximum static frictional forces and the kinetic frictional forces of coated wires were equal to or higher than those of the uncoated wires (p < 0.05). The maximum static frictional forces of rhodium-coated wires were significantly higher than those of polymercoated wires when the angulations between the brackets and wires were set to (i) $5^{\circ}$ in the 0.016-inch NiTi wires and (ii) all angulations in the $0.017{\times}0.025$-inch SS wires (p < 0.05). The kinetic frictional forces of rhodium-coated wires were higher than those of polymer-coated wires, except when the angulations were set to $0^{\circ}$ in the 0.016-inch NiTi wires (p < 0.05). Conclusions: Although the frictional forces of the coated wires with regards to aesthetics were equal to or greater than those of the uncoated wires, a study under similar conditions regarding the oral cavity is needed in order to establish the clinical implications.

Fatigue Life Properties of Messenger Wire with Service Environments (가설환경에 따른 조가선의 피로수명 특성)

  • 김용기;장세기;조성일
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.1
    • /
    • pp.21-28
    • /
    • 2003
  • Environment-dependent fatigue life of Cu-Cd alloy wires used as messenger wires was investigated. Tensile test results showed the decrease of tensile strength and elongation of messenger wires by 3.7% and 16.8%, respectively, in used specimens when compared to new ones. Messenger wires used at industrial region for 26 yeras showed 35∼50% decrease in fatigue life, which is partly due to the in stress concentrations by formation of corrosion products at the surface. Single wires showed better fatigue properties than stranded wires, especially at low cycle regions with higher stresses. Stranded wires showed shorter fatigue lives than single wires because of friction between wires by surface contact. Service life of messenger wires was dependent upon the environments which they were exposed to. SO$_2$ and humidity deteriorated the fatigue properties by environmental degradation.

THE STUDY 0F TENS10N CHARACTERISTICS IN ORTHODONTIC WIRES (교정용 철사의 인장 특성에 관한 연구)

  • Park, Dae-Han;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.14 no.2
    • /
    • pp.241-248
    • /
    • 1984
  • The mechanical properties of Cr-Ni alloy of austenitic stainless steel and Co-Cr alloy orthodontic wires were studied in tension. The wires (0.018 inch) were tested in the as-manufactured and heat-treated conditions. Instron type tension testing machine was used for this study. Mean values and standard deviations were computed. The results were as follows; 1. The Cr-Ni orthodontic wires of austenitic stainless steel are generally superior than the Co-Cr orthodontic wires in ultimate tensile strength, In the elongation, however, Co-Cr orthodontic wire are superior than Cr-Ni orthodontic wires. 2. Increase in the degree of strength by heat treatment are more clearly shown in Co-Cr orthodontic wires than Cr-Ni orthodontic wires. And the elongation is decreased by heat treatment in both case. 3. The changes of the degree of strength by cooling method we not clearly shown, but in Cr-Ni orthodontic wires, air cooling are more effective, in Co-Cr orthodontic wires, cooling effect are scarcely shown.

  • PDF

Magnetization loss of Hybrid Multi-Stacked wire made of 1G wires and 2G wires (1세대 선재와 2세대 선재의 혼합 적층에 따른 자화손실 특성)

  • Lim, H.;Lee, Y.;Lee, H.;Cha, G.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.57-60
    • /
    • 2007
  • Superconducting electric power devices need to stack HTS wires to increase the current carrying capacity. Uniform multi-stacked wires(UMS) which were made of the same HTS wires have been used. This paper shows the magnetization loss of hybrid multi-stacked(HMS) wire made of BSCCO wires and YBCO wires. Five HMS wires, YB(YBCO-BSCCO), YYBB. YBYB, YBBY and BYYB, were made and tested. Magnetization losses of each UMS wire were compared with corresponding HMS wire. Test results show that magnetization losses per unit length of HMS wire are between the corresponding UMS BSCCO wire and HMS YBCO wire below critical magnetic field. Above the critical magnetic field, magnetization losses of HMS wires are larger than that of corresponding both VMS wires.

Characteristics of AC loss of Hybrid Multi-Stacking with HTS Wires in External Magnetic Field (고온초전도 혼합적층선재의 외부자장 변화에 따른 손실 특설)

  • Lim, Hyoung-Woo;Lee, Dong-Min;Yun, Ki-Hyun;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.71-73
    • /
    • 2006
  • AC loss on variation of external magnetic field is a very important factor in development of power applications. In this paper, we measured and compared AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires and uniform-multi-stacked wire made of one type of wires, 1G wires or 2G wires. Measurement was performed using by the linked-picked coil method. As results, as the number of wires increase, AC loss per unit volume of both stacked wires in low external magnetic field is reduced. Also AC loss of 2G slacked wire is higher than that of 1G wire. AC loss per unit length of 2G stacked wire is less than that of 1G stacked wire. And AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires was between uniform-multi-stacked wire made of 1G wires and 2G wires.

  • PDF

AN EXPERIMENTAL STUDY ON FRICTIONAL FORCES OF VARIOUS ORTHODONTIC WIRES UNDER ARTIFICIAL SALIVA (인공타액하에서 수종 교정선의 마찰력에 관한 실험적 연구)

  • Hwang, Hyeon-Shik;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.19 no.1 s.27
    • /
    • pp.245-256
    • /
    • 1989
  • Translational movement along an arch wire requires sufficient force to overcome frictional forces between bracket and arch wire. The orthodontist must appreciate the importance of friction in this process, and study out the influencing factors on the level of friction. The purpose of this study was to evaluate the effect of artificial saliva on frictional resistances generated between the bracket and arch wire. Independent variables of this study were arch wire material, angulation and environment. Static frictional forces of cobalt-chromium, heat-treated cobalt-chromium, beta-titanium, stainless steel wires were measured under non-angulated dry, angulated dry, non-angulated saliva, angulated saliva conditions. The results were as follows: 1. Stainless steel wires showed lower friction values in non-angulated dry condition, and heat-treated cobalt-chromium wires showed higher friction values in angulated dry condition. Higher friction values were showed in order of cobalt-chromium. stainless steel, heat-treated cobalt-chromium and beta-titanium wires in non-angulated saliva condition. and were showed in order of stainless steel, cobalt-chromium, heat-treated cobalt-chromium, beta-titanium wires in angulated saliva condition. 2. Angulation increased friction for stainless steel wires under dry condition. 3. Artificial saliva decreased friction for cobalt-chromium wires and increased friction for stainless steel wires under non-angulated condition. 4. Artificial saliva decreased friction for all wires except beta-titanium wires under angulated condition. 5. Regardless of angulation or environment. heat-treated cobalt-chromium and beta-titanium wires showed higher friction values, and stainless steel wires showed lower friction values.

  • PDF

LASER WELDING OF TI-NI SHAPE MEMORY ALLOY WIRE

  • Kim, Young-Sik;Kim, Jong-Do
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.139-144
    • /
    • 2002
  • Ti-50.9at%Ni wires were welded using pulsed YAG laser. The laser welded wires were tested for investigating the shape memo교 effect and the ability of super elasticity. The fatigue properties of the welded wires were investigated using the rotary bending fatigue tester specially designed for wires. Moreover, the effect of defocusing distance during laser welding on the static and fatigue properties was investigated. The shape memory effect and super elasticity of the laser welded wires were approximately identical with that of base metal at the test temperature below 353K. However, the welded wires were broken within elastic limit at the test temperature above 353k. Under the cyclic bending loading conditions, the welded wires could be useful only below the elastic limit, while the base metal had sufficient fatigue life even the stress induced M-phase region. The fatigue strength of the welded wires was about half of that of the base metal. The deterioration of the static and fatigue properties in the welded wires was proven to be from the large difference of the transformation behavior between the base metal and welded part that is caused by vaporization of Ni-content at the welded part during the welding process. The defocusing distance below 3mm acted more largely on lowering the strength of the welded wires than that of 6mm or 8mm.

  • PDF

Fatigue Properties of Ti-Ni Shape Memory Alloy Wire Welded by Nd: YAG Laser

  • Kim, Y.S.;Kim, J.D.;Kil, B.L.
    • International Journal of Korean Welding Society
    • /
    • v.3 no.1
    • /
    • pp.39-44
    • /
    • 2003
  • The welded specimens were made by butt welding of the 2 wires of 50mm length using the pulsed YAG laser. The laser welded wires were tested for investigating the shape memory effect and the ability of super elasticity. The fatigue properties of the welded wires were investigated using the rotary bending fatigue tester specially designed for wires. Moreover, the effect of defocusing distance during laser welding on the static and fatigue properties was Investigated. The shape memory effect and super elasticity of the laser welded wires were approximately identical with that of base metal at the test temperature below 353K. However, the welded wires were broken within elastic limit at the test temperature above 353k. Under the cyclic bending loading conditions, the welded wires could be useful only below the elastic limit, while the base metal had sufficient fatigue life even the stress induced M-phase region. The fatigue strength of the welded wires was about half of that of the base metal. The deterioration of the static and fatigue properties in the welded wires was proven to be from the large difference of the transformation behavior between the base metal and welded part that is caused by vaporization of Ni-content at the welded part during the welding process. The defocusing distance below 3mm acted more largely on lowering the strength of the welded wires than that of 6mm or 8mm.

  • PDF