• Title/Summary/Keyword: Wireless body sensor system

Search Result 119, Processing Time 0.028 seconds

Basic Study on Monitoring System of Reservoir and Leeve Using Wireless Sensor Network (무선센서 네트워크 계측을 이용한 저수지 및 제방 계측시스템 구축에 관한 기초연구)

  • Yoo, Chanho;Kim, IkHoon;Lee, Seungjoo;Hwang, Jungsoon;Baek, Seungcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.1
    • /
    • pp.25-30
    • /
    • 2018
  • Conventional monitoring method is used for evaluation of the reservoir and levee at the highest height sections. In recent years, automated measurement technology has been developed, and the measurement results are transmitted, collected and stored in real time into management office. Despite the development of real time monitoring technology, the measurement results are not used directly or indirectly with facility management at real time. Recently, as wireless sensor network measurement technology has been developed based on internet of things, this study proposed a real - time measurement and evaluation system based on wireless sensor network technology in the reservoir structure. As a result of the seepage analysis for the application, it was confirmed that the volumetric water content changes together with the change of the seepage line inside the embankment body according to the change of the water level of the embankment. In other words, the applicability of the measurement system with the volumetric water ratio set as the sensor node was verified.

A Fast Localization Technique without Range Information in Wireless USB Services for Wearable Computer Systems (무선 USB 서비스 기반 웨어러블 컴퓨터 시스템의 Fast Range-Free 위치인식기법)

  • Hur, Kyeong;Sohn, Won-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.10
    • /
    • pp.1228-1235
    • /
    • 2012
  • In this Paper, we propose an energy efficient localization technique based on WUSB (Wireless USB) over WBAN (Wireless Body Area Networks) protocol required for Wearable Computer systems. For this purpose, the proposed localization algorithm minimizes power consumption and estimates location without range information. It is executed independently on the basis of WUSB over WBAN protocol at each sensor node comprising peripherals of a wearable computer system. And it minimizes power consumption by estimating locations of sensor nodes with range-free method fast.

A study on WSN based ECG and body temperature measuring system for ubiquitous healthcare: 2. Vital signal monitoring software system (유비쿼터스 헬스케어를 위한 센서 네트워크 기반의 심전도 및 체온 측정 시스템: 2. 생체신호 모니터링 소프트웨어 시스템)

  • Lee, Dae-Seok;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.417-424
    • /
    • 2006
  • An ubiquitous healthcare monitoring system for elderly person at home was designed for continuous healthy monitoring of elderly person or patients. Human vital signals, such as ECG and body temperature, were monitored by terminal PC or PDA via ECG and temperature sensor nodes on the patient's body. From the ECG data, the heart rate, tachycardia, bradycardia and arrhythmia were diagnosed on the terminal PC or PDA to assist doctor's or nurse's aid or patient itself to monitor the patient's condition and give medical examination. Artificial judgement support system was designed in server computer and the system support a doctor or nurser for management or treatment of the patient. This system can be applied to vital signal monitoring system for solitude elderly person at self house or home health care service part. And this ubiquitous healthcare system can reduce the medical expenses in coming aging or aged society.

Design and Implementation of Remote Diagnostics System for Wireless Sensor Network (Wireless Sensor Network를 이용한 원격 진료 시스템의 설계 및 구현)

  • Kim, Won-Joong;Jo, Jae-Joon;An, Sun-Shin
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.06d
    • /
    • pp.204-207
    • /
    • 2007
  • 최근 대두되고 있는 무선 센서네트워크는 실생활의 많은 부분에 있어 그 응용 분야를 넓혀 가고 있다. 본 연구는 WSN의 응용 중 Human Health Care에 주안을 두어 WSN을 이용한 원격 진료 시스템에 대해 설계 및 구현을 하였다. 원격 진료 시스템을 위해 각 센서 노드들은 인체의 Body 정보를 수집할 수 있는 센서들을 가지고 신체의 각 부위에 부착된다. 또한 각 센서 노드들은 고유의 Human Body Code를 가지고 있으며 이 고유의 Code에 의해 인체의 어느 부위에서 측정된 Data인지를 Sink 노드로 전송하게 된다. Sink 노드는 수집된 정보를 원격에 위치한 의료진들에게 전송하며 원격의 의료진들은 Sink 노드에서 전송된 정보를 바탕으로 진료 정보를 환자 및 User에게 Feedback하게 된다. Human Body Code는 인체를 세분화하고 각 세분화한 신체 부위에 계층적으로 고유의 Code를 부여한다. 본 연구에서는 실제 Human Body Code를 직접 제작한 센서 Node에 주입하여 Human Body Network을 구성하여 인체에서 센싱되는 Data를 원격에 위치한 PC에서 진료 가능한 원격 진료 시스템을 구현하였다.

  • PDF

Development of u-Lifecare Monitoring System Device (u-라이프케어 모니터링 시스템 단말기 개발)

  • Choi, Dong-Oun;Kang, Yun-Jeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.7
    • /
    • pp.1533-1540
    • /
    • 2012
  • u-Life care device collect body bio formation, and classify and store them in exercise patterns. Afterwards, the devices send the data through bluetooth wireless communication to the smart phones which set Google Android operation system at regular intervals. The information is checked out through application. u-Life care device calculates calories spent a day after monitoring activity quantity with 3-axis acceleration sensor. The device judges the status of health through body data mining and consults tailored exercise treatment. When sending body data, the device sends them in smart phone through Blue Tooth wireless communication at once. So, as a strong point, the device doesn't need mobile gateway or home gateway used for sending to web server information sensed from exercise life care products.

The Measurement System of ECG, Temperature and Humidity Using RF wireless Communication Technique (RF 무선통신 기술을 이용한 심전도 및 온.습도 측정 시스템)

  • Lim, Jin-Hee;Nam, Hyo-Duck;Jung, Woo-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.356-357
    • /
    • 2007
  • In this paper, we developed an integrated miniaturized device which acquires and transmits the signal of ECG an interested heartbeat and body's temperature and humidity. Using an amplifier circuit on the electrodes and the radio frequency transmission, the developed system dispenses with the use of cables among the electrodes, amplifier, and the post processing system. The sensor signals are transmitted to the RF-wireless terminal that was developed using the micro controller Aduc812, LCD, RF-module (frequency 424MHz, 9600-bps). In results, the developed system improves not only the signal-to-noise ration in dynamic ECG & and body's temperature and humidity measurement, but also the user convenience.

  • PDF

The Comparison of Performance Hierarchical Routing Protocols in Wide Area Sensor Field

  • Park, SeaYoung;Jung, KyeDong;Lee, Jong-Yong
    • International journal of advanced smart convergence
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 2016
  • Studies have been made for the wireless sensor network protocols by a number of researchers to date. In particular, the studies as to the hierarchical protocol LEACH algorithm was concentrated. Various studies have been derived for the performance of the protocol is based on the LEACH protocol have been made. Improved algorithms have been proposed continuously. On the other hand, The performance comparison and evaluation of the improved algorithm is insufficient. Therefore, we compared the performance for the ML-LEACH (Multi Hop-Layered) and DL-LEACH (Dual Hop-Layered) been derived mainly LEACH. scalability, energy consumption, CH elected, network lifetime were selected as a Performance evaluation items.

An Adaptive Transmission Power Control Algorithm for Wearable Healthcare Systems Based on Variations in the Body Conditions

  • Lee, Woosik;Kim, Namgi;Lee, Byoung-Dai
    • Journal of Information Processing Systems
    • /
    • v.15 no.3
    • /
    • pp.593-603
    • /
    • 2019
  • In wearable healthcare systems, sensor devices can be deployed in places around the human body such as the stomach, back, arms, and legs. The sensors use tiny batteries, which have limited resources, and old sensor batteries must be replaced with new batteries. It is difficult to deploy sensor devices directly into the human body. Therefore, instead of replacing sensor batteries, increasing the lifetime of sensor devices is more efficient. A transmission power control (TPC) algorithm is a representative technique to increase the lifetime of sensor devices. Sensor devices using a TPC algorithm control their transmission power level (TPL) to reduce battery energy consumption. The TPC algorithm operates on a closed-loop mechanism that consists of two parts, such as sensor and sink devices. Most previous research considered only the sink part of devices in the closed-loop. If we consider both the sensor and sink parts of a closed-loop mechanism, sensor devices reduce energy consumption more than previous systems that only consider the sensor part. In this paper, we propose a new approach to consider both the sensor and sink as part of a closed-loop mechanism for efficient energy management of sensor devices. Our proposed approach judges the current channel condition based on the values of various body sensors. If the current channel is not optimal, sensor devices maintain their current TPL without communication to save the sensor's batteries. Otherwise, they find an optimal TPL. To compare performance with other TPC algorithms, we implemented a TPC algorithm and embedded it into sensor devices. Our experimental results show that our new algorithm is better than other TPC algorithms, such as linear, binary, hybrid, and ATPC.

An Energy Efficient Time Synchronization Technique Based on WUSB over WBAN Protocol for Wearable Computer Systems (웨어러블 컴퓨터 시스템을 위한 WUSB over WBAN 프로토콜의 에너지 효율적인 시간 동기 기술)

  • Hur, Kyeong;Sohn, Won-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.7
    • /
    • pp.879-884
    • /
    • 2012
  • In this Paper, we propose an Energy Efficient Time Synchronization technique based on WUSB (Wireless USB) over WBAN (Wireless Body Area Networks) protocol required for Wearable Computer systems. For this purpose, the proposed Time Synchronization algorithm minimizes power consumption and estimates time information with accuracy. It is executed on the basis of WUSB over WBAN protocol at each sensor node comprising peripherals of a wearable computer system. It minimizes power consumption by exchanging time stamp packets and forming a hierarchical structure.

Partially Observable Markov Decision Processes (POMDPs) and Wireless Body Area Networks (WBAN): A Survey

  • Mohammed, Yahaya Onimisi;Baroudi, Uthman A.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.5
    • /
    • pp.1036-1057
    • /
    • 2013
  • Wireless body area network (WBAN) is a promising candidate for future health monitoring system. Nevertheless, the path to mature solutions is still facing a lot of challenges that need to be overcome. Energy efficient scheduling is one of these challenges given the scarcity of available energy of biosensors and the lack of portability. Therefore, researchers from academia, industry and health sectors are working together to realize practical solutions for these challenges. The main difficulty in WBAN is the uncertainty in the state of the monitored system. Intelligent learning approaches such as a Markov Decision Process (MDP) were proposed to tackle this issue. A Markov Decision Process (MDP) is a form of Markov Chain in which the transition matrix depends on the action taken by the decision maker (agent) at each time step. The agent receives a reward, which depends on the action and the state. The goal is to find a function, called a policy, which specifies which action to take in each state, so as to maximize some utility functions (e.g., the mean or expected discounted sum) of the sequence of rewards. A partially Observable Markov Decision Processes (POMDP) is a generalization of Markov decision processes that allows for the incomplete information regarding the state of the system. In this case, the state is not visible to the agent. This has many applications in operations research and artificial intelligence. Due to incomplete knowledge of the system, this uncertainty makes formulating and solving POMDP models mathematically complex and computationally expensive. Limited progress has been made in terms of applying POMPD to real applications. In this paper, we surveyed the existing methods and algorithms for solving POMDP in the general domain and in particular in Wireless body area network (WBAN). In addition, the papers discussed recent real implementation of POMDP on practical problems of WBAN. We believe that this work will provide valuable insights for the newcomers who would like to pursue related research in the domain of WBAN.