• Title/Summary/Keyword: Wireless Signals

Search Result 714, Processing Time 0.028 seconds

A Study on Algorithm of Emotion Analysis using EEG and HRV (뇌전도와 심박변이를 이용한 감성 분석 알고리즘에 대한 연구)

  • Chon, Ki-Hwan;Oh, Ju-Young;Park, Sun-Hee;Jeong, Yeon-Man;Yang, Dong-Il
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.10
    • /
    • pp.105-112
    • /
    • 2010
  • In this paper, the bio-signals, such as EEG, ECG were measured with a sensor and their characters were drawn out and analyzed. With results from the analysis, four emotion of rest, concentration, tension and depression were inferred. In order to assess one's emotion, the characteristic vectors were drawn out by applying various ways, including the frequency analysis of the bio-signals like the measured EEG and HRV. RBFN, a neural network of the complex structure of unsupervised and supervised learning, was applied to classify and infer the deducted information. Through experiments, the system suggested in this thesis showed better capability to classify and infer than other systems using a different neural network. As follow-up research tasks, the recognizance rate of the measured bio-signals should be improved. Also, the technology which can be applied to the wired or wireless sensor measuring the bio-signals more easily and to wearable computing should be developed.

Real-time Intelligent Health and Attention Monitoring System for Car Driver (실시간 지능형 운전자 건강 및 주의 모니터링 시스템)

  • Shin, Heung-Sub;Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.5
    • /
    • pp.1303-1310
    • /
    • 2010
  • Recently, researches related with automative mechanism have been widely studied to increase the driver's safety by continuously monitoring the driver's health condition to prevent driver's drowsiness. This paper describes the design of wearable chest belt for ECG and reflectance pulse oximetry for SpO2 sensors based on wireless sensor network to monitor the driver's healthcare status. ECG, SpO2 and heart rate signals can be transmitted via wireless sensor node to base station connected to the server. Intelligent monitoring system is designed at the server to analyze the SpO2 and ECG signals. HRV (Heart Rate Variability) signals can be obtained by processing the ECG and PPG signals. HRV signals are further analyzed based on time and frequency domain to determine the driver's drowsiness status.

Real-time Intelligent Health and Attention Monitoring System for Car Driver by Measurement of Vital Signal (생체신호 측정에 의한 실시간 지능형 운전자 건강 및 주의 모니터링 시스템)

  • Shin, Heung-Sub;Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.545-548
    • /
    • 2009
  • Recently, researches related to automative mechanism have been widely studied to increase the driver's safety by continuously monitoring the driver's health condition to prevent driver's drowsiness. This paper describes the design of wearable chest belt for ECG and reflectance pulse oximetry for $SpO_2$ sensors based on wireless sensor network to monitor the driver's healthcare status. ECG, $SpO_2$ and heart rate signals can be transmitted via wireless sensor node to base station connected to the server. Intelligent monitoring system is designed at the server to analyze the $SpO_2$ and ECG signals. HRV(Heart Rate Variability) signals can be obtained by processing the ECG and PPG signals. HRV signals are further analyzed based on time and frequency domain to determine the driver's drowsiness status.

  • PDF

Study on Compressed Sensing of ECG/EMG/EEG Signals for Low Power Wireless Biopotential Signal Monitoring (저전력 무선 생체신호 모니터링을 위한 심전도/근전도/뇌전도의 압축센싱 연구)

  • Lee, Ukjun;Shin, Hyunchol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.89-95
    • /
    • 2015
  • Compresses sensing (CS) technique is beneficial for reducing power consumption of biopotential acquisition circuits in wireless healthcare system. This paper investigates the maximum possible compress ratio for various biopotential signal when the CS technique is applied. By using the CS technique, we perform the compression and reconstruction of typical electrocardiogram(ECG), electromyogram(EMG), electroencephalogram(EEG) signals. By comparing the original signal and reconstructed signal, we determines the validity of the CS-based signal compression. Raw-biopotential signal is compressed by using a psuedo-random matrix, and the compressed signal is reconstructed by using the Block Sparse Bayesian Learning(BSBL) algorithm. EMG signal, which is the most sparse biopotential signal, the maximum compress ratio is found to be 10, and the ECG'sl maximum compress ratio is found to be 5. EEG signal, which is the least sparse bioptential signal, the maximum compress ratio is found to be 4. The results of this work is useful and instrumental for the design of wireless biopotential signal monitoring circuits.

Structure of Dual Polarized System for Wireless Communication (무선 통신을 위한 이중 편파 시스템 구조)

  • Kim, Jaekil;Gwak, Gye Seok;Ahn, Jae Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.8
    • /
    • pp.746-755
    • /
    • 2014
  • In this paper, we propose the structure of a dual polarized system for a wireless communication. The proposed dual polarized antenna is formed by one vertical antenna and two horizontal antennas that are orthogonal to each other. Vertical and horizontal polarized antennas transmit different signals, but two orthogonal horizontal polarized antennas transmit the same data signals. So, the signals of the proposed dual polarized system construct two dual-polarization planes. And, only one dual-polarization plane with a large signal power is selected at the side of a receiver. The simulation results show that the proposed dual polarized system could obtain a higher capacity compared to an ordinary $2{\times}2$ MIMO (Multi-input Multi-output) system.

An Experimental Study of the Cochlea-inspired Artificial Filter Bank(CAFB) for Compressed Sensing (압축센싱을 위한 달팽이관 원리기반 인공필터뱅크의 실험적 검증)

  • Heo, Gwanghee;Jeon, Joonryong;Jeon, Seunggon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.11
    • /
    • pp.787-797
    • /
    • 2015
  • In this paper, a cochlea-inspired artificial filter bank(CAFB) was developed in order to efficiently acquire dynamic response of structure, and it was also evaluated via dynamic response experiments. To sort out signals containing significant modal information from all the dynamic responses of structure, it was made to adopt a band-pass filter optimizing algorithm(BOA) and a peak-picking algorithm (PPA). Optimally designed on the basis of El-centro and Kobe earthquake signals, it was then embedded into the wireless multi-measurement system(WiMMS). In order to evaluate the performance of the developed CAFB, a vibration test was conducted using the El-centro and Kobe earthquake signals, and structural responses of a two-span bridge were obtained and analyzed simultaneously by both a wired measurement system and a CAFB-based WiMMS. The test results showed that the compressed dynamic responses acquired by the CAFB-based WiMMS matched with those of the wired system, and they included significant modal information of the two-span bridge. Therefore this study showed that the developed CAFB could be used as a new, economic, and efficient measurement device for wireless sensor networks(WSNs) based real time structural health monitoring because it could reconstruct the whole dynamic response using the compressed dynamic response with significant modal information.

Study on the Transmission of Medical Information using Bluetooth Technology (블루투스를 이용한 의료정보 신호의 전송에 관한 연구)

  • 엄정규;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.520-523
    • /
    • 2001
  • In this paper, a system that transmits ECG signals which get from hand baggage ECG is implemented by using Bluetooth technology. Bluetooth technology is a close range wireless communication used wireless frequency 2.4GHZ bandwidth. This technology consumes very small power and provides high reliability also self error correction with high speed frequency hopping. Because every device which uses Bluetooth protocol can communicate each other. These can connect between the system implemented and any devices such as mobile telephone with Bluetooth module, notebook, and the personal mobile device. Also, the paper proposes capability of transmission to the sever of hospital through each type of wireless communication device that acquired medical information signals in mobile medical machine. The system consists of hardware parts with Bluetooth module and host part, and software parts with bluetooth protocol stacks. The host precesses a connection with other device and transmits ECG signals with bluetooth frequency hopping sequence.

  • PDF

Study on the Transmission of Medical Information using Bluetooth Technology (블루투스를 이용한 의료정보 신호의 전송에 관한 연구)

  • 엄정규;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.2
    • /
    • pp.297-301
    • /
    • 2001
  • In this paper, a system that transmits ECG signals which get from hand baggage ECG is implemented by using Bluetooth technology. Bluetooth technology is a close range wireless communication used wireless frequency 2.4GHz bandwidth. This technology consumes very small power and provides high reliability also self error correction with high speed frequency hopping. Because every device which uses Bluetooth protocol can communicate each other. These can connect between the system implemented and any devices such as mobile telephone with Bluetooth module, notebook, and the personal mobile device. Also, the paper proposes capability of transmission to the sever of hospital through each type of wireless communication device that acquired medical information signals in mobile medical machine. The system consists of hardware parts with Bluetooth module and host part, and software parts with blutooth protocol stacks. The host precesses a connection with other device and transmits ECG signals with bluetooth frequency hopping sequence.

  • PDF

An Analysis of Radio Interference in the Rain Radars (강우 레이더 전파간섭 분석)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • The interference among the rain radars and interference in the adjacent wireless station due to the spurious signals from the rain radar were analyzed in this paper. The rain radar measures the rain intensity using S-band signal. The measured data are utilized in forecasting the rainfall. The interference among the rain radars or in the adjacent wireless stations may be caused by the operation with low elevation angle and the high output power. Based on the propagation analysis of S band signal and the deduced interference protection ratio of rain radar, the interference due to the rain radar are analyzed. Also, the radiation spectrum characteristics of a rain radar are deduced from the caused interference effects by the spurious signals of the rain radar. To minimize the interference effects for adjacent wireless stations, it is required to get the rejection characteristics of spurious signals above 105 dB. In viewpoints of interference for rain radars, it is necessary to operate the rain radar with a different PRF and operation time opposite to adjacent rain radars.

Evaluation on MRC Diversity Reception of M-ary PSK and DPSK Signals on Wireless Fading Channels

  • Kim, Chung-Sock;Kim, Chang-Hwan;Jin, Yong-Ok
    • Journal of electromagnetic engineering and science
    • /
    • v.7 no.3
    • /
    • pp.109-115
    • /
    • 2007
  • The performances of M-ary PSK(MPSK) systems using L-branch maximum ratio combining(MRC) diversity reception in frequency-nonselective slow Rician fading channels are derived theoretically. Especially we investigate the effect of number of symbols on the difference between the approximation to bit error probability and the exact bit error rate(BER) in evaluating the performance of MPSK signals through numerical analyses. On the other hand, when M-ary DPSK(MDPSK) signals experience the Rician fading channels, the general formula for evaluating BER of MDPSK signals in the independent branch diversity system is presented using the integral-form expressions.