• Title/Summary/Keyword: Wireless Communication Module

Search Result 480, Processing Time 0.023 seconds

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF

The introductory study for MIMO techniques over satellite systems

  • Kang, Yeon-Su;Kang, Kun-Suk;Ahn, Do-Seob
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.80-84
    • /
    • 2007
  • In this paper, the introductory study of the multi input multi output (MIMO) techniques for satellite communication systems is presented. Because of the advantage of wide coverage of satellite, it has been considered for broadcasting services and fill-in services. On the other hand, state of the art multi input multi output (MIMO) techniques such as space time code (STC) and spatial multiplexing (SM) makes the terrestrial system increase link performance and their coverage, and also increase the link throughput. For these regard, in order to satisfy the requirements of the next generation communications and coexists with terrestrial systems harmoniously, the studying about satellite MIMO techniques is necessary. In this paper, we introduce some system model and scenarios to apply MIMO technique to intermediate module repeater (IMR). The possibility of these techniques and technical requirements are also considered. Especially, Space time code is used to enhance IMRs coverage and increase the link performance, and space time multiplexing is utilized to multiplex satellite broadcasting signals with local broadcasting signal in IMR cell.

  • PDF

Design and Implementation of LoRa-based Emergency Exit Guide System (LoRa 기반 피난 유도 체계의 설계 및 구현)

  • Shin, Jaejun;Eun, Seongbae;So, Sun-Sup;Kim, Byungho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.4
    • /
    • pp.569-574
    • /
    • 2018
  • This paper proposes and implements a LoRa-based emergency exit guide system which can direct the optimal refuge path accounting for the real state of the fires. Each 4-way emergency exit guide sign presents a right direction through one of four LED signs toward the possible exit dynamically calculated by the shortest path algorithm. We constructed a simulation environment with 8 spots of the emergency exit guide signs and 2 exits, which can simulate variant cases of fire accidents, and showed that the proposed algorithm can presents the right guidance for each emergency exit guide sign. We also evaluated the performances of LoRa-based wireless communications using a self developed communication module in the various indoor and outdoor environments. The proposed system can be applied to small and medium sized buildings as well as larger ones in terms of cost efficiency, in which there's no needs to invest for the complex equipments except only sensors and emergency exit guide signs.

Development of a Cost Effective Radio Communication System for UAS (무인항공기용 저비용 고효율 무선통신 시스템 개발)

  • Park, Sang-Hyuk;Kim, Sung-Su;Choi, Kee-Young;Park, Choon-Bae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.6
    • /
    • pp.600-607
    • /
    • 2008
  • Reliable wireless transmission of data generated by the flight critical subsystems or mission equipments of the unmanned aerial system is critical for mission success. As the UAS system becomes more sophisticated, its dependency on a reliable high rate radio communication system also increases. This requirement is applied not only during the operation phase but also in the early development test phase. This paper introduces a practical cost-effective communication system for a UAS. The downlink module combines analog NTSC video signal with onboard data, and send them using 2.4 GHz carrier wave. The uplink system has less a severe requirement on the bandwidth, and thus uses 430 MHz signal. This paper also presents a sample packet structure which can be adopted for many UAS of similar class.

Embedded Multi-LED Display System based on Wireless Internet using Otsu Algorithm (오츠 알고리즘을 활용한 무선인터넷 기반 임베디드 다중 LED 전광판 시스템)

  • Jang, Ho-Min;Kim, Eui-Ryong;Oh, Se-Chun;Kim, Sin-Ryeong;Kim, Young-Gon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.6
    • /
    • pp.329-336
    • /
    • 2016
  • In the outdoor advertising and industrial sites, are trying to implement the LED electric bulletin board system that is based on image processing in order to express a variety of intention in real time. Recently, in various field, rather than simple text representation, the importance of intuitive communication using images is increasing. Thus, instead of outputting the simple input information for communication, a system that can output a real-time information being sought. Therefore, the system is directed to overcoming by converting the problem of mapping an image on a variety of conventional LED display that can not be output images, the possible image output formats. Using an LED of low power, it has developed to output the efficient messages and images within a limited resources. This paper provides a system capable of managing the LED display on the wireless network. Atmega2560, Wi-Fi module, using the server and Android applications client, rather than printing a text only, it is a system to reduce the load generated image output character output in to the conversion process as can be managed by the server.

Real-time Feedback Vibration Control of Structures Using Wireless Acceleration Sensor System - System Design and Basic Performance Evaluation - (무선 가속도센서 시스템을 이용한 건축물의 실시간 피드백 진동제어 - 시스템 구축 및 기초성능 평가 -)

  • Jeon, Joon Ryong;Park, Ki Tae;Lee, Chin Ok;Heo, Gwang Hee;Lee, Woo Sang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.21-32
    • /
    • 2013
  • This is a preliminary study for the real-time feedback vibration control of building structures. The study developed a wireless acceleration sensor system based on authentic technology capacities, to integrate with the Prototype AMD system and ultimately construct the feedback vibration control system. These systems were used to evaluate the basic performance levels of the control systems within model building structures. For this purpose, the study first developed a wireless acceleration sensor unit that integrates an MEMS sensor device and bluetooth communication module. Also, the study developed an operating program that enables control output based on real-time acceleration response measurement and control law. Furthermore, the Prototype AMD and motor driver system were constructed to be maneuvered by the AC servo-motor. Eventually, all these compositions were used to evaluate the real-time feedback vibration control system of a 2-story model building, and qualitatively measure the extent of vibrational reduction of the target structure within the laboratory validation tests. As a result of the tests, there was a definite vibrational reduction effect within the laboratory validation tests. As a result of the tests, there was a definite vibrational reduction effect within 1st and 2nd resonance frequency as well as the random frequency of the model building structure. Ultimately, this study confirmed the potential of its wireless acceleration sensor system and AMD system as an effective tool that can be applied to the active vibration control of other structures.

Flexible USIM Authentication System for Next Generation Mobile Radio Communication Systems (차세대 이동통신 시스템에서 유동적 USIM 카드를 이용한 인증 시스템)

  • Choi, Dong-Wook;Hwang, Jae-Young;Chung, Yeon-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.11
    • /
    • pp.2340-2346
    • /
    • 2011
  • This paper presents a user-friendly authentication system using a flexible USIM. In the proposed method and its system, the flexible USIM utilizes personalized data such as Mobile Directory Number(MDN) and social security number as the key to user authentication. The authentication method proposed in this paper permits limited times of use and/or limited duration of use. A simple simulation model shows that the proposed algorithm works well and shows high compatibility with existing authentication methods. In addition, an alternative or more advanced authentication system can be developed with the proposed flexible USIM card. It is seen that this simple alternative method will eventually be able to make wireless communication networks more easily accessible for subscribers, irrespective of user environments.

Mobile Remote Healthcare in Ubiquitous Computing Environments (유비쿼터스 환경에서 모바일을 이용한 원격 헬스케어)

  • Kang, Eun-Young;Im, Yong-Soon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.6
    • /
    • pp.55-61
    • /
    • 2008
  • In this paper, we proposed a multi-agent based healthcare system (MAHS) which is the combination of medical sensor module and wireless communication technology. This MAHS provides wide services to mobile telemedicine, patient monitoring, emergency management, doctor's diagnosis and prescription, patients and doctors, information exchange between hospital workers in a long distance. Also, MAHS is connected to Body Area Network (BAN) and a doctor and hospital workers. In addition, we designed and implemented extended JADE based MAHS that reduces hospital server's burden. Agents gather, integrate, and deliver the collected patient's information from sensor, and provide presentation in healthcare environment. Proposed MAHS has advantage that can handle urgent situation in the far away area from hospital like Islands through PDA and mobile device. In addition, by monitoring condition of patient (old man) in a real time base, it shortens time and expense and supports medical service efficiently.

  • PDF

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.

Development of a Smart Grid Monitoring System with Anti-Islanding Function for Electric Vehicle Charging (안티아일랜딩 기능을 적용한 전기자동차 충전계통 연계 스마트그리드 모니터링 시스템 개발)

  • Ro, Sunny;Shin, Bum-Sik;Lee, Kyung-Jung;Ki, Young-Hun;Ahn, Hyun-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.31-37
    • /
    • 2012
  • In this paper, we present a smart grid monitoring system connected with electric vehicle charging system using anti-islanding method. Electric vehicles can be charged through remote control of smart grid monitoring system and the charging process may be more stable and more efficient by wireless communication between the Local Area Module and End Modules. It is illustrated by some experiments that electric vehicle charging process may not be interrupted without any serious fault even though the islanding phenomena occurred in the grid if the presented monitoring system was applied to the smart grid system.