• Title/Summary/Keyword: Wire tension

Search Result 249, Processing Time 0.028 seconds

Evaluation For Adhesion in Tension of SBR Polymer Modified Concrete Tensile by Uniaxial Method (직접인장방법에 의한 SBR 폴리머 개질 콘크리트의 부착강도 특성 평가)

  • Yun, Kyong-Ku;Jang, Heung-Gyun;Lee, Nam-Ju;Lee, Seung-Jae;Hong, Chang-Woo
    • International Journal of Highway Engineering
    • /
    • v.3 no.4 s.10
    • /
    • pp.117-126
    • /
    • 2001
  • In this research, evaluation of adhesion in tension property of SBR-modified concrete to ordinary portland cement concrete was conducted with uniaxial direct tensile bond test which was proposed by Kuhlmann. A test set-up was fabricated in order to minimize the eccentric force by introducing a joint which might fully rotate. The main experimental variables were cement-latex ratios, surface preparations and moisture levels. The results obtained were as follows: The LMC specimen at 15% latex-cement ratio increased the adhesion in tension by range of 37% compared to that of conventional cement concrete. This might be due to latex film formed between cement paste and aggregate. The effects of surface preparation on bond of latex modified concrete to conventional concrete were significant at the conditions by sand paper and wire brush. A better bond could be achieved by rough surface rather than smooth. The saturated and surface dry (SSD) condition were considered to be the most appropriate moisture level followed by wet, finally by dry. Thus, a proper surface preparation and moisture level are quite necessity in order to obtain better bonding at LMC overlay.

  • PDF

THE ROOT RESORPTION AND THE PERIODONTAL TISSUE CHANGE AFTER ORTHODONTIC TOOTH MOVEMENT OF THE VITAL AND ENDODONTICALLY TREATED TOOTH IN THE DOG (실활치의 교정적 치아이동시 치근 및 치주조직의 변화에 관한 실험적 연구)

  • Shim, Won Seop;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.20 no.3 s.32
    • /
    • pp.447-462
    • /
    • 1990
  • The objective of this experiment is to observe structural differences in the othodontic movement of vital (control group) and devitalized (experimental group) teeth in the mongrel dogs. The 5 utilized dogs in this experiment were approximately 1 year of age and their average weight was about 12 Kg. Endodontic therapy was performed on the 2nd premolars in upper & lower jaws of each animal under the general anesthesia by intravascular injection of 25mg/kg of pentobarbital sodium. The canals of the teeth were obturated by using gutta percha in conjunction with root canal sealer (AH26 Densply). One of the roots in the 2nd premolars was hemisected to make an extraction space for the devitalized teeth to be moved. The edgewise technique was employed for the movement of the teeth. Orthodontic models and intraoral roentgenograms were taken before and after orthodontic tooth movement. The open coil springs (.010 x .040) were used at interbraket space in order to provide equal forces (75gm) between the teeth in each arch wire. After 13 weeks of active orthodontic tooth movement, dogs were sacrified and the experimental results w ere examined through the intraoral radiography, microscopic examination and scanning electromicroscopic examination at the root sulfate. From the results of the study, the following conclusions may be drawn: The root resolution and cemental deposition were observed within the pressure and tension site in both group. 2. The root resorbed lacunae were observed in the cementum and/or into the dentin in both group. 3. The prominent osteoblastic activities were observed on the alveolar margin in the tension site in both group. 4. A few of blood vessels were observed in the pressure site, but also lots of blood vessels were observed in the tension site especially in the periphery of the alveolar bone in both group. 5. In the pressure site, resorbed lacunae were formed with deep and narrow cavity in the control group; the shallow and wide cavity in the experimental group. 6. In the pressure site, the repaired cementum or cementoid tissue was lined on cementum in the experimental group, but not in the control group. 7. There was no significant difference between external root resolution of endodontically and vital teeth when both were subjected to orthodontic forces.

  • PDF

Diagonal bracing of steel frames with multi-cable arrangements

  • Husem, Metin;Demir, Serhat;Park, Hong G.;Cosgun, Suleyman I.
    • Structural Engineering and Mechanics
    • /
    • v.59 no.6
    • /
    • pp.1121-1137
    • /
    • 2016
  • A large number of structure in the world were build with poor seismic details, with or without any lateral load resisting system like concentrically braced frames and steel plate shear walls. These structures can reveal deteriorating hysteretic behaviors with stiffness and strength degradation. Therefore, seismic retrofitting of such structures for drift control has vital importance. In this study a retrofit methodology has been developed, which involves diagonal bracing of steel frames with different cable arrangements. In the experimental and numerical program 5 different lateral load resisting system were tested and results compared with each other. The results indicated that multi-cable arrangements suggested in this study showed stable ductile behavior without any sudden decrease in strength. Due to the usage of more than one diagonal cable, fracture of any cable did not significantly affect the overall strength and deformation capacity of the system. In cable braced systems damages concentrated in the boundary zones of the cables and beams. That is why boundary zone must have enough stiffness and strength to resist tension field action of cables.

Strengthening of bolted shear joints in industrialized ferrocement construction

  • Ismail, M.;Shariati, M.;Abdul Awal, A.S.M.;Chiong, C.E.;Chahnasir, E. Sadeghipour;Porbar, A.;Heydari, A.;Khorami, M.
    • Steel and Composite Structures
    • /
    • v.28 no.6
    • /
    • pp.681-690
    • /
    • 2018
  • This paper highlights results of some experimental work that deals with strengthening of bolted shear joints in thin-walled ferrocement structure where steel wires, bent into U-shape are considered as simple inserts around the bolt hole. The parameters investigated include the number of layers of wire mesh, edge distance of bolt hole, size and location of the inserts. Test results have shown that for small edge distance, failure occurred either in cleavage or shearing mode, and the strength of the joint increased with an increase in the edge distance. This continued up to an upper limit set by either tension or bearing failure. The experimental study further revealed that for a given edge distance the strength of a joint can significantly be enhanced by using U-inserts. The equations developed for predicting joint strength in ferrocement composites can also be modified to include the effects of the inserts with a good level of accuracy.

Design and evaluation of renovated NSI T/O PC sleeper (개량형 NSI 분기기용 PC침목 설계와 성능평가)

  • Park, Choon-Bok;Kwon, Ho-Jin;Lee, Young-Sou;Yoon, Byung-Hyun;Shin, Won-Sun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1129-1137
    • /
    • 2007
  • 50kg NSI PCT(Prestress Concrete Timber, sleeper) is developed for the purpose of low maintenance cost, Extend life cycle, Track stability, Friendly Environment, Good running quality. In this study, as a part of research which is to make renovated NSI turnout, the main objective of this study is the optimization of PC sleeper's section, the number of PS tension wire. For this purpose, the finite element analysis was conducted to evaluate the serviceability and the safety of NSI PC sleeper developed.

  • PDF

Percutaneus Cerclage Wiring in Distal Clavicle Fracture Type 2a - One Case Report - (원위 쇄골 골절 2a 형에서의 경피적 환상 강선 고정술 -1례 보고-)

  • Kim, Jae-Hwa;Lee, Soon-Chul;Cho, Duck-Yun;Yoon, Hyung-Ku;Lee, Yoon-Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.124-129
    • /
    • 2006
  • Distal clavicular fracture frequently requires operative treatment due to high rate of non-union. The operative technique includes the tension band wiring, K- wire fixation, and cerclage wiring etc. Each method has disadvantages somewhat like pin migration or acromioclavicular joint injury and so on. For the distal clavicular fracture type 2a, because of its oblique fracture line, the cerclage wiring is suitable. We performed the cerclage wiring percutaneously under minimal incision without injury to periosteum for the patient who had the distal clavicular fracture type 2a, and the result was favorable.

Development and Characterization of Vertical Type Probe Card for High Density Probing Test (고밀도 프로빙 테스트를 위한 수직형 프로브카드의 제작 및 특성분석)

  • Min, Chul-Hong;Kim, Tae-Seon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.9
    • /
    • pp.825-831
    • /
    • 2006
  • As an increase of chip complexity and level of chip integration, chip input/output (I/O) pad pitches are also drastically reduced. With arrival of high complexity SoC (System on Chip) and SiP (System in Package) products, conventional horizontal type probe card showed its limitation on probing density for wafer level test. To enhance probing density, we proposed new vertical type probe card that has the $70{\mu}m$ probe needle with tungsten wire in $80{\mu}m$ micro-drilled hole in ceramic board. To minimize alignment error, micro-drilling conditions are optimized and epoxy-hardening conditions are also optimized to minimize planarity changes. To apply wafer level test for target devices (T5365 256M SDRAM), designed probe card was characterized by probe needle tension for test, contact resistance measurement, leakage current measurement and the planarity test. Compare to conventional probe card with minimum pitch of $50{\sim}125{\mu}m\;and\;2\;{\Omega}$ of average contact resistance, designed probe card showed only $22{\mu}$ of minimum pitch and $1.5{\Omega}$ of average contact resistance. And also, with the nature of vertical probing style, it showed comparably small contact scratch and it can be applied to bumping type chip test.

The Design and Implementation of the Explorer Robot Adaptive Pipe Magnitude Width and Curve (파이프 크기와 굴곡에 적응하는 탐사로봇 설계 및 구현)

  • Lee, Kwang-Seok;Lee, Byeong-Ro;Choo, Yeon-Gyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.3
    • /
    • pp.602-607
    • /
    • 2009
  • Most of explorer robot in past has the fixed magnitude and communicate with wire communication method. In case of various range of pipe's width and various angle in pipe inter structure, the exploring work is very difficult. Thus, in this paper, we design as dealing with spring tension with pushing out pipe exterior, and applied RF communication. We can accept good performance both structure change and improvement of ability, monitor and collect the defaults data in pipe inter structure. Newly designed and developed pipe explorer robot is very advantageous to carrying and driving as being small and law weight.

A Study of the real-time graphic deformation algorithm with virtual environment control (가상환경 제어에서 실시간 그래픽 변형에 관한 연구)

  • Kim, Young-Su;Bae, Chul;Kim, A-Hyun;Park, Kyung-Seok;Kang, Won-Chan;Kim, Young-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2265-2267
    • /
    • 2003
  • In this paper, the virtual reality system is tried to developed, which controls not only the sense of sight and hearing but also the sense of touch, In order to develope the sense of touch in this study, the stable tactual transaction system, based on summing up the basic algorithm and theory is embodied. Especially, the graphic deformation algorithm is developed in realtime with using the deformed FEM. To apply the FEM, a deformed material model is produced and then the graphic deformation with this model is able to force. Finally, the graphic transaction algorithm is deduced by the realtime calculation and simplification because the purpose of this system is to transact in real time. The result of this study is that the proposed system is possible to deform the graphics and transact the haptic in real time in PC. The simulation program has been made to prove this result.

  • PDF

The effects of applied voltage on copper powder manufactured by electric explosion (전기폭발방식을 이용한 동(Cu) 미분 제조 및 인가전압의 영향)

  • Lee, Hoo-In;Kim, Won-Baek;Suh, Chang-Youl;Sohn, Jeong-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.474-475
    • /
    • 2007
  • Wire electrical explosion(WEE) has been used for the production of fine metal particles. In WEE, electrical powder was stored and compressed into capacitor and released to produce fine particles through evaporation and condensation. In this study, the effect of applied voltage on the size of copper powders was investigated. High tension was added up to the explosion device by dividing 4 steps. At voltages lower than 5.2 kV, the fraction of powders finer than $44{\mu}m$ was almost negligible. The effectiveness of explosion increased sharply with increased voltage over 5.8 kV. At the highest voltage of 6.4 kV, more than 80% of explosion products were finer than $44{\mu}m$.

  • PDF