• Title/Summary/Keyword: Wire structure

Search Result 655, Processing Time 0.024 seconds

Experimental Modal Analysis of the Hinge Structure (힌지 구조물의 실험적 동특성 해석)

  • 전병희;양명석;강휘원;이기범
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.629-634
    • /
    • 2004
  • Modal parameters of the total missile structure including a hinge mechanism are estimated by the experimental modal analysis. The free-free boundary condition is simulated by hanging the missile structure with a wire rope, and the missile structure is excited by the random vibration technique. Test results are used to verify the FE analysis, the 1-D FE model is modified by 3-D model at the hinge part. Consequently, the modal parameters of the missile structure are estimated preciously.

  • PDF

Soft Morphing Motion of Flytrap Robot Using Bending Propagating Actuation (밴딩 전파 구동을 이용한 파리지옥 로봇의 소프트 모핑 동작)

  • Kim, Seung-Won;Koh, Je-Sung;Cho, Maeng-Hyo;Cho, Kyu-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.3
    • /
    • pp.168-174
    • /
    • 2012
  • This paper presents a bending propagating actuation using SMA (Shape Memory Alloy) spring for an effective shape transition of a flytrap-inspired soft morphing structure. The flytrap-inspired soft morphing structure is made from unsymmetric CFRP (Carbon Fiber Reinforced Prepreg) structure which shows bi-stability and snap-through phenomenon. For a thin and large curved bistable CFRP structure, SMA spring is more acceptable than SMA wire and piezoelectric actuator which used in previous investigations. A bending propagating actuation is proposed which can induce snap-through of the bi-stable CFRP structure effectively. From this research, effective shape transition of soft morphing structure is possible.

Influence of Ge addition on AC loss and micro-structure in $Nb_{3}Sn$ wires (Ge를 첨가한 Nb$_3$Sn 초전도 선에서의 교류손실 및 미세조직 변화)

  • 하도우;이남진;오상수;하홍수;송규정;권영길;류강식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.104-107
    • /
    • 2001
  • In order to investigate the effect of Ge addition to the Cu matrix on the microstructure and the critical current density, four kinds of internal tin processed Nb$_3$Sn strands with pure Cu and Cu 0.2, 0.4, 0.6 wt % Ge alloys were drawn to 0.8 mm diameter. The microstructure and critical current of internal tin processed Nb$_3$Sn wires that were heat treated at temperatures ranging from 68$0^{\circ}C$ to 74$0^{\circ}C$ for 240h were investigated. The Ge addition to the matrix did not make workability worse. A Ge rich layer in the Cu-Ge matrix suppressed the growth of the Nb$_3$Sn layer and promoted grain coarsening. The greater the Ge content in the matrix, the lower the net Jc result after Nb$_3$sn reaction heat treatment. There was no significant variation in Jc observed with heat treatment temperature ranging from 68$0^{\circ}C$ to 74$0^{\circ}C$. The values of AC loss of Ge added wires were decreased to 40 % compare with no addition wire. Low AC loss was due to segregation of Ge rich layer in the Cu-Ge matrix. If Ge added wire with thin Nb filaments were fabricated, slow diffusion rate of Sn would be overcome and decreased AC loss that is weak Point of internal tin method.

  • PDF

A Broad-Band Metamaterial Absorber Using Flexible Substrate (유연성 기판을 사용한 광대역 메타 흡수체)

  • Lee, Hong-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.3
    • /
    • pp.339-347
    • /
    • 2014
  • In this paper, the authors present a new design for a broad-band metamaterial(MTM) absorber that utilizes flexible substrate. The proposed MTM unit cell is constructed by a electric-inducive-capacitive(ELC) resonator and a cut-wire on the same side of the flexible polyimide substrate. To reduce the radar cross section at frequencies other than the targeted frequency bands, the metallic pattern layer of the proposed structure is placed facing toward the incident wave propagation direction. A prototype absorber was fabricated with a planar array of $33{\times}45$ unit cells. Our experiments showed that the proposed absorber exhibits a peak absorption rate of 92 % and 93 % at 9.06 GHz and 15.0 GHz, respectively, and 75 % of the full-width at half-maximum(FWHM) bandwidth is achieved. The proposed backplane-less MTM structure can be used for a broad-band microwave absorber and irregular surface applications.

Extraction of Effective Permittivity and Permeability of Periodic Metamaterial Cells (주기 구조 Metamaterial의 유효 유전율과 투자율 추출)

  • Lee, Dong-Hyun;Park, Wee-Sang
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.8
    • /
    • pp.60-68
    • /
    • 2008
  • The complex permittivity and permeability of various periodic metamaterial (MTM) cells are extracted by simulating a fictitious rectangular waveguide consisting of PEC and PMC walls. The shapes of the MTM cells include a thin wire (TW), a single split-ring resonator (SSRR), a double SRR (DSRR), a modified SRR, and a combined structure of the TW and the DSRR. The TW falls on a negative-$\varepsilon$/positive-$\mu$ region, the SRRs on a positive-$\varepsilon$/negative-$\mu$ region, and the combined structure on a negative-$\varepsilon$/negative-$\mu$ region. We also investigate how the permeability and permeability are affected by the dimension parameters of the MTM cells. Another extraction technique utilizing time domain signals is developed overcoming some limitations that the waveguide technique can not handle.

Thermal-hydraulic analysis of He-Xe gas mixture in 2×2 rod bundle wrapped with helical wires

  • Chenglong Wang;Siyuan Chen;Wenxi Tian;G.H. Su;Suizheng Qiu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2534-2546
    • /
    • 2023
  • Gas-cooled space reactor, which adopts He-Xe gas mixture as working fluid, is a better choice for megawatt power generation. In this paper, thermal-hydraulic characteristics of He-Xe gas mixture in 2×2 rod bundle wrapped with helical wires is numerically investigated. The velocity, pressure and temperature distribution of the coolant are obtained and analyzed. The results show that the existence of helical wires forms the vortexes and changes the velocity and temperature distribution. Hot spots are found at the contact corners between helical wires and fuel rods. The highest temperature of the hot spots reach 1600K, while the mainstream temperature is less than 400K. The helical wire structure increases the friction pressure drop by 20%-50%. The effect extent varies with the pitch and the number of helical wires. The helical wire structure leads to the reduction of Nusselt number. Comparing thermal-hydraulic performance ratios (THPR) of different structures, the THPR values are all less than 1. It means that gas-cooled space reactor adopting helical wires could not strengthen the core heat removal performance. This work provides the thermal-hydraulic design basis for He-Xe gas cooled space nuclear reactor.

Cold Rolling and Heat Treatment Characteristics of TiNi Based Shape Memory Wire (TiNi계 형상기억합금 선재의 냉간압연 및 열처리 특성)

  • Kim, R.H.;Kim, H.S.;Jang, W.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.30 no.6
    • /
    • pp.251-257
    • /
    • 2017
  • The effect of annealing temperature on the martensitic transformation behavior, tensile deformation chracteristics and shape recovery etc., has been studied in TiNi based shape memory ribbon fabricated by coldrolling of wire. TiNi based shape memory wire (${\phi}=500{\mu}m$) of which structure is intermetallic compound could be cold-rolled without process annealing up to the reduction rate in thickness of 50%, but a few cracks appear in cold-rolled ribbon in the reduction rate in thickness of 65%. The $B2{\rightarrow}R{\rightarrow}B19^{\prime}$ martensitic transformation or $B2{\rightarrow}B19^{\prime}$ martensitic transformation occurs in annealing conditions dissipating lattice defects introduced by coldrolling. However, in case of higher reduction rate or lower annealing temperature, martensitic transformation in cold-rolled and then annealed ribbons does not occur. The maximum shape recovery rate of cold-rolled ribbons with the reduction rate of 35 and 65% could be achieved at annealing temperatures of 250 and $350^{\circ}C$, respectively. The shape recovery rate seems to be related to the stress level of plateau region on stress-strain curve.

Retrofitting of exterior RC beam-column joints using ferrocement jackets

  • Bansal, Prem Pal;Kumar, Maneek;Dar, Manzoor Ahmed
    • Earthquakes and Structures
    • /
    • v.10 no.2
    • /
    • pp.313-328
    • /
    • 2016
  • Beam-column joints are recognized as one of the most critical and vulnerable zones of a Reinforced Concrete (RC) moment resisting structure subjected to seismic loads. The performance of the deficient beam-column joints can be improved by retrofitting these joints by jacketing them with varied materials like concrete, steel, FRP and ferrocement. In the present study strength behavior of RCC exterior beam-column joints, initially loaded to a prefixed percentage of the ultimate load, and retrofitted using ferrocement jacketing using two different wrapping schemes has been studied and presented. In retrofitting scheme, RS-I, wire mesh is provided in L shape at top and at bottom of the beam-column joint, whereas, in scheme RS-II along with wire mesh in L shape at top and bottom wire mesh is also provided diagonally to the joint. The results of these retrofitted beam-column joints have been compared with those of the controlled joint specimens. The results show an improvement in the ultimate load carrying capacity and yield load of the retrofitted specimens. However, no improvement in the ductility and energy absorption has been observed.

Flow Measurements and Performance Analysis using a 5-Hole Pitot Tube and a Rotating Hot-Wire Probe in an Axial Flow Fan (5공 피토관 및 회전 열선 유속계에 의한 축류 홴 내부 유동장 계측 및 평가)

  • Jang, Choon-Man;Kim, Kwang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1750-1757
    • /
    • 2003
  • This paper describes the flow measurements inside the blade passage of an axial flow fan by using a rotating hot-wire probe sensor from a relative flame of reference fixed to the rotor blades. The validity of fan rotor designed by a streamline curvature equation was performed by the measurement of the three-dimensional flow upstream and downstream of the fan rotor using a 5-hole pitot tube. The vortical flow structure near the rotor tip can be clearly observed by the measurements of a relative velocity and its fluctuation on quasi-orthogonal planes to a tip leakage vortex. Larger vortical flow, which results in higher blockage in the main flow, is formed according to decrease a flow rate. The vortical flow spreads out to the 30 percent span from the rotor tip at near stall condition. In the design operating condition, the tip leakage vortex is moved downstream while the center of the vortex keeps constant in the spanwise direction. Detailed characteristics of a velocity fluctuation with relation to the vortex were also analyzed.

A Study on the Characteristics of Repair Welding for Mold Steel using Continuous Wave Nd:YAG Laser (연속파형 Nd:YAG 레이저를 이용한 금형강의 보수용접 특성에 관한 연구)

  • Yoo, Young-Tae;Shin, Ho-Jun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.7-16
    • /
    • 2010
  • In this study, wire was used as the filler material for the laser repair welding, and the phenomenon in which the supplied filler material was melted and beaded down into the specimen was examined with varying laser powers and welding speeds. The optimal processing condition was found to be the laser power of 1,300 W, the welding speed and feed wire supply speed of 0.5 ml/in and the defocused distances of +2mm. At this time, the heat input(E) was $65{\sim}75\;J/mm^2$, and no internal defect occurred. When repair welding was carried out as the optimal processing for the part that had an external defect with the radius of 2mm, the filler metal was melted, resulting in the volume smaller than the defect part and thus causing the part unfilled. Therefore, it was found to be necessary to carry out repair welding two to three times by multiple passes rather than does it only once by single pass.