• 제목/요약/키워드: Wire Speed Fluctuation

검색결과 11건 처리시간 0.021초

GMAW에서 와이어 송급속도의 변동이 아크안정성에 미치는 영향에 관한 연구 (Effects of Wire speed Fluctuation on Arc Stability in GMA Welding)

  • 신현욱;최용범;성원호;장희석
    • Journal of Welding and Joining
    • /
    • 제13권4호
    • /
    • pp.85-102
    • /
    • 1995
  • Weld quality of GMA welding processes is closely related to arc stability. Although many researches on arc stability have been performed, real-time estimation of arc stability has not been attempted. For instance, Mita proposed a off-line statistical method in which short circuiting and arcing time, and voltage and current wave forms were sampled to assess arc stability. But this method is not suitable to assess arc stability for GMA welder which employ inverter power source due to its controlled current and voltage wave forms. In this paper, the relationship between are stability and wire feed rate fluctuation is analyzed to propose new criterion for inverter power source. When arc voltage and arc current and arcing time are analyzed, we can assess arc stability only for short circuit transfer mode. When wire feed rate is analyzed, we can estimate arc stability udner the condition of spray transfer mode as well. Hence, the wire feed rate is chosen for monitoring process variable to cover possible metal transfer modes in GMAW. Through this research, it has been identified that arc stability in GMA welding processes is closely related to wire fed rate. When inverter power source is used, conventional statistical method of estimating arc stability, such as Mita index, is no longer valid due to its controlled voltage and current wave forms. Arc stability has been also examined in phase plane diagram.

  • PDF

전기철도 속도향상에 따른 전차선로 가선 시스템 최적화에 관한 연구 (A Study on the Overhead Contact Lines Optimization According to the Increased Train Speed)

  • 정인철;정락교;최규형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.3037-3045
    • /
    • 2011
  • The optimization of the overhead contact lines according to the increased train speed is to design the low-sag-wire so that the pantograph can follow the vertical fluctuation of the catenary. Main factors for the overhead contact lines design include the span, dropper interval, movable bracket, vertical fluctuation of the catenary, tension, and wave propagation speed. In this paper, a model is proposed to improve the electric railway speed, and the speed improvement analysis technology is examined to ensure the stable and reliable electric railway. In addition, the effect between pantograph and catenary according to the speed improvement is quantitatively analyzed by using simulation.

  • PDF

밀폐된 동시회전 디스크 유동장에 대한 열선 지지대의 영향 (The Effect of a Hot-wire Supporter on the Flow Between Corotating Disks in Shroud)

  • 공대위;주원구
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.663-666
    • /
    • 2002
  • Hard disk drived (HDD) in computer are used extensively as data storage capacity. The trend in the computer industry to produce smaller disk drives rotating at higher speeds requires an improved understanding of fluid motion in the space between disks. The distribution of pressure disturbance on disks has relation to flow structure. To investigate the flow structure, time-resolved hot-wire measurements of the circumferential velocity component were obtained for the flow between the center pair of four disks of common radius $R_2$ coretating at angular velocity ${\Omega}$ in a fixed cylindrical enclosure. Hot-wire supporter acts as an obstruction in this case. The effects of rotating speed and size of hot-wire supporter diameter between disks on the flow driven by disks were investigated. Velocity spectra at the fixed space were measured to obtain the structure of inner and outer region in flow field.

  • PDF

Optimal Shape of Blunt Device for High Speed Vehicle

  • Rho, Joo-Hyun;Jeong, Seongmin;Kim, Kyuhong
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제17권3호
    • /
    • pp.285-295
    • /
    • 2016
  • A contact strip shape of a high speed train pantograph system was optimized with CFD to increase the aerodynamic performance and stability of contact force, and the results were validated by a wind tunnel test. For design of the optimal contact strip shape, a Kriging model and genetic algorithm were used to ensure the global search of the optimal point and reduce the computational cost. To enhance the performance and robustness of the contact strip for high speed pantograph, the drag coefficient and the fluctuation of the lift coefficient along the angle of attack were selected as design objectives. Aerodynamic forces were measured by a load cell and HWA (Hot Wire Anemometer) was used to measure the Strouhal number of wake flow. PIV (Particle Image Velocimetry) was adopted to visualize the flow fields. The optimized contact strip shape was shown a lower drag with smaller fluctuation of vertical lift force than the general shaped contact strip. And the acoustic noise source strength of the optimized contact strip was also reduced. Finally, the reduction amount of drag and noise was assessed when the optimized contact strip was applied to three dimensional pantograph system.

유량에 따른 축류홴의 익단누설와류 특성 (Flow Characteristics of a Tip Leakage Vortex at Different Flow Rates in an Axial Flow Fan)

  • 장춘만;김광용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1383-1388
    • /
    • 2004
  • The flow characteristics in the blade passage of a low speed axial flow fan have been investigated by experimental analysis using a rotating hot-wire sensor for design and off-design operating conditions. The results show that the tip leakage vortex is moved upstream when flow rate is decreased, thus disturbing the formation of wake flow near the rotor tip. The tip leakage vortex interfaces with blade pressure surface, and results in high velocity fluctuation near the pressure surface. From the relative velocity distributions near the rotor tip, large axial velocity decay is observed at near stall condition, which results in large blockage compared to that at the design condition. Througout the flow measurements using a quasi-orthogonal measuring points to the tip leakage vortex, it is noted that the radial position of the tip leakage vortex is distributed between 94 and 96 percent span for all flow conditions. High spectrum density due to the large fluctuation of the tip leakage vortex is observed near the blade suction surface below the frequency of 1000 Hz at near stall condition.

  • PDF

유량에 따른 축류홴의 익단누설와류 및 후류 특성 (Flow Characteristics of Wake Flow with Relation to a Tip Leakage Vortex at Different Flow Rates in an Axial Flow Fan)

  • 김광용;장춘만
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.322-329
    • /
    • 2005
  • The flow characteristics in the blade passage and in the wake region of a low speed axial flow fan have been investigated by experimental analysis using a rotating hot-wire sensor for design and off-design operating conditions. The results show that the tip leakage vortex is moved upstream when flow rate is decreased, thus disturbing the formation of wake flow near the rotor tip. The tip leakage vortex interfaces with blade pressure surface, and results in high velocity fluctuation near the pressure surface. From axial velocity distributions downstream of the fan rotor, large axial velocity decay near the rotor tip is observed at near stall condition, which results in large blockage compared to that at the design condition. Although the wake flow downstream of the rotor blade is clearly measured at all operating conditions, the trough of the high velocity fluctuation due to Karmann vortex street in the wake flow is mainly observed at a higher flow condition than the design flow rate.

원심압축기 깃 없는 디퓨저에서의 선회실속에 관한 실험적 연구 (An experimental study on rotating stall in vaneless diffuser of a centrifugal compressor)

  • 신유환;김광호;손병진
    • 대한기계학회논문집B
    • /
    • 제22권2호
    • /
    • pp.153-161
    • /
    • 1998
  • This study describes the results of the analysis of measured rotating stall signal in a centrifugal compressor with vaneless diffuser. Unsteady flow and rotating stall in vaneless diffuser were investigated by measuring of unsteady velocity fluctuation using hot-wire anemometer. Experiments were carried out in several impeller rotating speeds, at different radius ratios. Single hot -wire was used to study the characteristics of rotating stall. As a result, the abrupt rotating stall was detected at all measured impeller rotating speeds and the several flow coefficients which are less than 0.16. The number of the stall cell was one at all measured rotational speeds, and the rotating direction was the same as that of the impeller. As the flow rate decreased, the profile of the phase averaged radial velocity component with time changed from a sawtooth to a sine wave.

예혼합 연소기에서의 화염 전달 함수 측정 (Flame Transfer Function Measurement in a Premixed Combustor)

  • 김대식;김기태;전승배;이종근
    • 한국연소학회지
    • /
    • 제13권2호
    • /
    • pp.1-6
    • /
    • 2008
  • An experimental study of the flame response in a turbulent premixed combustor has been conducted with room temperature, atmospheric pressure inlet conditions using premixed natural gas. The fuel is premixed with the air upstream of a choked inlet to avoid equivalence ratio fluctuations. Therefore the observed flame response is only the result of the imposed velocity fluctuations, which are produced using a variable speed siren. Measurements are made of the velocity fluctuation in the nozzle using hot wire anemometry and of the heat release fluctuation in the combustor using chemiluminescence emission. The results are analyzed to determine the phase and gain of the flame transfer function as a function of the modulation frequency. Of particular interest is the effect of flame structure on the flame response predictions and measurements. The results show that both the gain and the phase of flame transfer function are closely associated with the flame length and structure, which is dependent upon the upstream flow perturbation as well as equivalence ratio in the current study.

  • PDF

A harmonic movable tooth drive system integrated with shape memory alloys

  • Xu, Lizhong;Cai, Zongxing;He, Xiaodong
    • Smart Structures and Systems
    • /
    • 제23권4호
    • /
    • pp.319-327
    • /
    • 2019
  • Continuous rotating SMA actuators require motion conversion mechanisms, so their structure is relatively complex and difficult to realize the miniaturization. Here, a new type of continuous rotating actuator driven by SMA is proposed. It combines the movable tooth drive with SMA drive. The structure and working principle of the integrated movable tooth drive system is introduced. The equations of temperature, stress and strain of memory alloy wires, and the output torque of drive system are given. Using these equations, the temperature, the output forces of the SMA wires, and output torque of the drive system are studied. Results show that the compact drive system could give large output torque. To obtain large output torque plus small fluctuation, large eccentricity and small diameter of the SMA wire should be taken. Combined application of ventilation cooling and high current can increase the rotary speed of the drive system.