• Title/Summary/Keyword: Windows System

Search Result 1,451, Processing Time 0.031 seconds

Design & Performance of the Solar Energy Research & Test Center (태양에너지 연구 시험센타 설계 및 효율에 관한 연구)

  • Auh, Paul Chung-Moo;Lee, Jong-Ho;Choi, Byung-Owan;Cho, Yil-Sik
    • Solar Energy
    • /
    • v.2 no.2
    • /
    • pp.29-36
    • /
    • 1982
  • The Solar Energy R&D Department of KIER under the auspice of the Korean government is pushing hard on the development of the passive solar technology with high priority for the expeditious widespread use of solar energy in Korea, since the past few years of experiences told us that the active solar technology is not yet ready for massive commercialization in Korea. KIER has completed the construction of the Solar Energy Research & Test Center in Seoul, which houses the major facilities for its all solar test programs. The Center was designed as a passive solar building with great emphasis on the energy conserving ideas. The Center is not only the largest passive building in Korea, but also the exhibit center for the effective demonstration of the passive heating and cooling technology to the Korean public. The Center was designed to satisfy the requirements based on the technical and economical criteria set by the KIER. Careful considerations, therefore, were given in depth in the following areas to meet the requirements. 1) Passive Heating Concepts The Center employed the combination of direct and indirect gain system. The shape of the Center is Balcomb House style, and it included a large built-in sunspace in front. A partition, consists of transparent and translucent glazings, separates the sunspace and the living space. Since most activities in the Center occur during the day time, direct utilization of the solar energy by the living spaces was emphasized with the limited energy storage capacity. 2) Passive Cooling Concepts(for Summer) Natural ventilation concept was utilized throughout the building. In the direct gain portion of the system, the front glazing can be openable during the cooling season. Natural convection scheme was also applied to the front sunspace for the Summer cooling. Reflective surfaces and curtains were utilized wherever needed. 3) Auxiliary Heat ing and Cooling System As an auxiliary cooling system, mechanical means(forced convection system) were adopted. Therefore forced air heating system was also used to match the duct work requirements of the auxiliary cool ing system. 4) Effect ive Insulation & Others These included the double glazed windows, the double entry doors, the night glazing insulation, the front glazing-frame insulation as well as the building skin insulation. All locally available construction materials were used, and natural lightings were provided as much as possible. The expected annual energy savings (compared to the non-insulated conventional building)of the Center was estimated to be about 80%, which accounts for both the energy conservation and the solar energy source. The Center is being instumented for the actual performance tests. The experimental results of the simplified tests are discussed in this paper.

  • PDF

Development of an Editor and Howling Engine for Realtime Software Programmable Logic Controller based on Intelligent Agents (지능적 에이전트에 의한 실시간 소프트웨어 PLC 편집기 및 실행엔진 개발)

  • Cho, Young-In
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.12
    • /
    • pp.1271-1282
    • /
    • 2005
  • Recently, PC-based control is incredibly developed in the industrial control field, but it is difficult for PLC programming in PC. Therefore, I need to develop the softeware PLC, which support the international PLC programming standard(IECl131-3) and can be applied to diverse control system by using C language. In this paper, I have developed the ISPLC(Intelligent Agent System based Software Programmable Logic Controller). In ISPLC system, LD programmed by a user which is used over $90\%$ among the 5 PLC languages, is converted to IL, which is one of intermediate codes, and IL is converted to the standard C rode which can be used in a commercial editor such as Visual C++. In ISPLC, the detection of logical error in high level programming(C) is more eaier than PLC programming itself The study of code conversion of LD->IL->C is firstly tried in the world as well as KOREA. I developed an execution engine with a good practical application. To show the effectiveness of the developed system, 1 applied it to a practical case, a real time traffic control(RT-TC) system. ISPLC is minimized the error debugging and programming time owing to be supported by windows application program.

An Application-Specific and Adaptive Power Management Technique for Portable Systems (휴대장치를 위한 응용프로그램 특성에 따른 적응형 전력관리 기법)

  • Egger, Bernhard;Lee, Jae-Jin;Shin, Heon-Shik
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.8
    • /
    • pp.367-376
    • /
    • 2007
  • In this paper, we introduce an application-specific and adaptive power management technique for portable systems that support dynamic voltage scaling (DVS). We exploit both the idle time of multitasking systems running soft real-time tasks as well as memory- or CPU-bound code regions. Detailed power and execution time profiles guide an adaptive power manager (APM) that is linked to the operating system. A post-pass optimizer marks candidate regions for DVS by inserting calls to the APM. At runtime, the APM monitors the CPU's performance counters to dynamically determine the affinity of the each marked region. for each region, the APM computes the optimal voltage and frequency setting in terms of energy consumption and switches the CPU to that setting during the execution of the region. Idle time is exploited by monitoring system idle time and switching to the energy-wise most economical setting without prolonging execution. We show that our method is most effective for periodic workloads such as video or audio decoding. We have implemented our method in a multitasking operating system (Microsoft Windows CE) running on an Intel XScale-processor. We achieved up to 9% of total system power savings over the standard power management policy that puts the CPU in a low Power mode during idle periods.

On the Architecturally Planned Logic System of Gyeonghoeru Pavilion in Gyeongbokgung Palace - Concentrating on The Book of Gyeonghoeru Pavilion (慶會樓全圖) written by Jeong Haksun - (경복궁 경회루의 건축계획적 논리체계에 관한 연구 - 정학순의 "경회루전도(慶會樓全圖)" 를 중심으로 -)

  • Lee, Sang-Hae;Zho, In-Choul
    • Journal of architectural history
    • /
    • v.14 no.3 s.43
    • /
    • pp.39-52
    • /
    • 2005
  • This study relates to the architectural planning principle of Gyeonghoeru pavilion, one of the major buildings in Gyeongbokgung palace. The study is concentrated on The Book of Gyeonghoeru Pavilion written by Jeong Haksun in 1865 during the reconstruction of Gyeonghoeru pavilion. The architectural planning principle of Gyeonghoeru pavilion disclosed in The Book of Gyeonghoeru Pavilion appears to be 'the method of expanding with six by six system'. 'The method of expanding with six by six system' means a way of continuously extending the number related to 6 by addition, subtraction, multiplication and division, and reflecting to architecture, having number 6 as the basic number. Number 6 means a large amount of water in East Asian philosophy, Applying 'the method of expanding with six by six system' to the architecture of Gyeonghoeru includes an intention to prevent fire in a way of a type of incantation because Korean traditional wooden buildings are we to fire. Since Gyeonghoeru is surrounded by a pond and was constructed based on the number 6 having a strength of water, it was believed that it could be safe from fire. This study compares the contents disclosed in The Book of Gyeonghoeru Pavilion with the construction of Gyeonghoeru to find out how the number 6 was applied to the overall construction of Gyeonghoeru. From the fact that the total number of km of Gyeonghoeru is 36 ($6{\times}6$), the number of pillars is 42 ($6{\times}7$), and the number of windows and doors is multiples of 6, it has been found out that the number 6 is deeply related to the overall construction of Gyeonghoeru. In addition to the fact that the construction of Gyeonghoeru can be explained by 'the method of expanding with six by six system', The Book of Gyeonghoeru Pavilion also discloses parts where Diagram of Hotu, Later Heaven Arrangement and Arrangement of 64 Hexagrams are applied. Therefrom, it has been found out that Gyeonghoeru pavilion was constructed by applying the principles of East Asian philosophy based on The Book of Changes.

  • PDF

DESIGN AND IMPLEMENTATION OF HITL SIMULATOR COUPLEING COMMUNICATIONS PAYLOAD AND SOFTWARE SPACECRAFT BUS (통신탑재체와 소프트웨어 위성버스체를 통합한 HITL 시뮬레이터의 설계 및 구현)

  • 김인준;최완식
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.4
    • /
    • pp.339-350
    • /
    • 2003
  • Engineering qualification model payload for a communications and broadcasting satellite(CBS) was developed by ETRI from May, 2000 to April, 2003. For. the purpose of functional test and verification of the payload, a real-time hardware-in-the-loop(HITL) CBS simulator(CBSSIM) was also developed. We assumed that the spacecraft platform for the CBSSIM is a geostationary communication satellite using momentum bias three-axis stabilization control technique based on Koreasat. The payload hardware is combined with CBSSIM via Power, Command and Telemetry System(PCTS) of Electrical Ground Support Equipment(EGSE). CBSSIM is connected with PCTS by TCP/IP and the payload is combined with PCTS by MIL-STD-1553B protocol and DC harness. This simulator runs under the PC-based simulation environment with Windows 2000 operating system. The satellite commands from the operators are transferred to the payload or bus subsystem models through the real-time process block in the simulator. Design requirements of the CBSSIM are to operate in real-time and generate telemetry. CBSSIM provides various graphic monitoring interfaces and control functions and supports both pre-launch and after-launch of a communication satellite system. In this paper, the HITL simulator system including CBSSIM, communications payload and PCTS as the medium of interface between CBSSIM and communications payload will be described in aspects of the system architecture, spacecraft models, and simulator operation environment.

Development of the Automated Ultrasonic Testing System for Inspection of the flaw in the Socket Weldment (소켓 용접부 결함 검사용 초음파 자동 검사 장비 개발)

  • Lee, Jeong-Ki;Park, Moon-Ho;Park, Ki-Sung;Lee, Jae-Ho;Lim, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.275-281
    • /
    • 2004
  • Socket weldment used to change the flow direction of fluid nay have flaws such as lack of fusion and cracks. Liquid penetrant testing or Radiography testing have been applied as NDT methods for flaw detection of the socket weldment. But it is difficult to detect the flaw inside of the socket weldment with these methods. In order to inspect the flaws inside the socket weldment, a ultrasonic testing method is established and a ultrasonic transducer and automated ultrasonic testing system are developed for the inspection. The automated ultrasonic testing system is based on the portable personal computer and operated by the program based Windows 98 or 2000. The system has a pulser/receiver, 100MHz high speed A/D board, and basic functions of ultrasonic flaw detector using the program. For the automated testing, motion controller board of ISA interface type is developed to control the 4-axis scanner and a real time iC-scan image of the automated testing is displayed on the monitor. A flaws with the size of less than 1mm in depth are evaluated smaller than its actual site in the testing, but the flaws larger than 1mm appear larger than its actual size on the contrary. This tendency is shown to be increasing as the flaw size increases. h reliable and objective testing results are obtained with the developed system, so that it is expected that it can contribute to safety management and detection of repair position of pipe lines of nuclear power plants and chemical plants.

Energy Performance Evaluation of Low Energy Houses using Metering Data (실측데이터를 이용한 저에너지주택의 에너지성능평가)

  • Baek, Namchoon;Kim, Sungbum;Oh, Byungchil;Yoon, Jongho;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

The Effects of distilled Astragali Radix Herbal Acupuncture on the Heart Rate Variability(HRV) (황인 약침이 정산인의 심박변이도(HRV)에 미치는 영향)

  • Lim, Sung-Taek;Kim, Lak-Hyung;Song, Beom-Yong;Yook, Tae-Han
    • Journal of Oriental Neuropsychiatry
    • /
    • v.19 no.1
    • /
    • pp.107-124
    • /
    • 2008
  • We investigated the effects of distilled Astragali Radix Herbal Acupuncture on autonomic nervous system with the Heart Rate Variability(HRV) in adult man. as well as we tried to observe how distilled Astragali Radix Herbal Acupuncture on the balance of the autonomic nervous system. Methods : We investigated on 61 healthy volunteers consisted of 31 subjects in experiment(distilled Astragali Radix Herbal Acupuncture) group and 30 subjects in control(Normal Saline) group. Study form was a randomized, placebo-controlled, double-blind clinical trial. 31 subjects in experiment group were injected distilled Astragali Radix Herbal Acupuncture at GB21(Kyonjong) and 30 subjects in control group were injected Normal Saline at GB21(Kyonjong). except of 2 subjects(in control group) who can't be measured and 10 subjects(6 in experiment group and 4 in control group) who move or make unforceable error during measuring. Finally 25 subject in experiment group and 24 subject in control group are studied. We measured HRV by PolyG-I on 7 times : before and after injection per 5 minutes during 30 minutes. The SPSS 10.0 for windows was used to analyze the data and the paired t test(in group) and Student t test(between two groups) were used to verify the result. Results : I. After distilled Astragali Radix Herbal Acupuncture injection, SDNN is significantly high from 5 minute to 10 minute and from 15 minute to 30 minute, Complexity is significantly low from 20 minute to 30minute. HRV index is significantly mgb for first 20 minute and from 25 minute to 30 minute, RMSSD is significantly high only from 15 minute to 20 minute. 2. HRV index of distilled Astragali Radix Herbal Acupuncture Group significantly increased from 25 minute to 30 minute, pNN50 of distilled Astragali Radix Herbal Acupuncture Group significantly decreased from 25 minute to 30 minute and RMSSD of distilled Astragali Radix Herbal Acupuncture Group significantly increased from 25 minute to 30 minute compared with those of Normal Saline group. 3. After distilled Astragali Radix Herbal Acupuncture injection, Ln(TP) is significantly high from 5 minute to 10 minute and from 15 minute to 30 minute. Ln(VLF) is significantly high after 5 minute, Ln(LF) is significantly high after 15 minute and Ln(HF) is significantly high from 5 minute to 10 minute and 25 minute to 30 minute, but significantly low for first 5 minute and from 10 minute to 20 minute. Normalized LF is significantly high after 20 minute and Normalized LF is significantly low after 20 minute. Conclusions : The results suggest that distilled Astragali Radix Herbal Acupuncture in healthy adult man tend to activate the autonomic nervous system within normal range. This result is derived from that parasympathetic nervous system was continuously activated and sympathetic nervous system was activated a little later.

  • PDF

A Study on the Ransomware Detection System Based on User Requirements Analysis for Data Restoration (데이터 복원이 가능한 사용자 요구사항 분석기반 랜섬웨어 탐지 시스템에 관한 연구)

  • Ko, Yong-Sun;Park, Jae-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.50-55
    • /
    • 2019
  • Recently Ransomware attacks are continuously increasing, and new Ransomware, which is difficult to detect just with a basic vaccine, continuously has its upward trend. Various solutions for Ransomware have been developed and applied. However, due to the disadvantages and limitations of existing solutions, damage caused by Ransomware has not been reduced. Ransomware is attacking various platforms no matter what platform it is, such as Windows, Linux, servers, IoT devices, and block chains. However, most existing solutions for Ransomware are difficult to apply to various platforms, and there is a limit that they are dependent on only some specific platforms while operating. This study analyzes the problems of existing Ransomware detection solutions and proposes the onboard module based Ransomware detection system; after the system defines the function of necessary elements through analyzing requirements that can actually reduce the damage caused by the Ransomware from the viewpoint of users, it supports various OS without pre-installation and is able to restore data even after being infected. We checked the feasibility of each function of the proposed system through the analysis of the existing technology and verified the suitability of the proposed techniques to meet the user's requirements through the questionnaire survey of a total of 264 users of personal and corporate PC users. As a result of statistical analysis of the questionnaire results, it was found that the score of intent to introduce the system was at 6.3 or more which appeared to be good, and the score of intent to change from existing solution to the proposed system was at 6.0 which appeared to be very high.

Research on the Design of TPO(Time, Place, 0Occasion)-Shift System for Mobile Multimedia Devices (휴대용 멀티미디어 디바이스를 위한 TPO(Time, Place, Occasion)-Shift 시스템 설계에 대한 연구)

  • Kim, Dae-Jin;Choi, Hong-Sub
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2009
  • While the broadband network and multimedia technology are being developed, the commercial market of digital contents as well as using IPTV has been widely spreading. In this background, Time-Shift system is developed for requirement of multimedia. This system is independent of Time but is not independent of Place and Occasion. For solving these problems, in this paper, we propose the TPO(Time, Place, Occasion)-Shift system for mobile multimedia devices. The profile that can be applied to the mobile multimedia devices is much different from that of the setter-box. And general mobile multimedia devices could not have such large memories that is for multimedia data. So it is important to continuously store and manage those multimedia data in limited capacity with mobile device's profile. Therefore we compose the basket in a way using defined time unit and manage these baskets for effective buffer management. In addition. since the file name of basket is made up to include a basket's time information, we can make use of this time information as DTS(Decoding Time Stamp). When some multimedia content is converted to be available for portable multimedia devices, we are able to compose new formatted contents using such DTS information. Using basket based buffer systems, we can compose the contents by real time in mobile multimedia devices and save some memory. In order to see the system's real-time operation and performance, we implemented the proposed TPO-Shift system on the basis of mobile device, MS340. And setter-box are desisted by using directshow player under Windows Vista environment. As a result, we can find the usefulness and real-time operation of the proposed systems.