• Title/Summary/Keyword: Window ratio

Search Result 403, Processing Time 0.028 seconds

A Comparative Study on Heating Energy Consumption for Apartment Based on the Annually Strengthened Criteria of Insulation (공동주택 연도별 단열기준 강화에 따른 에너지소요량 비교 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.83-89
    • /
    • 2013
  • Energy consumption is closely related to our lives. As Korea has four seasons, heating and cooling system is considered as essential facilities for the residential buildings. Accordingly, the government has continuously strengthened the design criteria to improve energy for new and existing building to save energy. The most important factor in the energy efficiency analysis for apartment is the heat transmission coefficient, and the value is significantly different as the heating energy amount is greatly different according to the window area ratio versus facade area ratio. Therefore, it is time to conduct continuous set-up for goal to enhance efficiency and restriction on window area ratio versus facade area ratio.

The Meaning of P50 Suppression : Interaction of Gamma and Alpha Waves

  • Lee, Kyungjun;Kang, Ung Gu
    • Korean Journal of Biological Psychiatry
    • /
    • v.21 no.4
    • /
    • pp.168-174
    • /
    • 2014
  • Objectives Sensory gating dysfunctions in patients with schizophrenia and bipolar disorder have been investigated through two similar methods ; P50 suppression and prepulse inhibition paradigms. However, recent studies have demonstrated that the two measures are not correlated but rather constitute as distinct neural processes. Recent studies adopting spectral frequency analysis suggest that P50 suppression reflects the interaction between gamma and other frequency bands. The aim of the present study is to investigate which frequency component shows more significant interaction with gamma band. Methods A total of 108 mood disorder patients and 36 normal subjects were included in the study. The P50 responses to conditioning and test stimuli with an intra-pair interval of 500 msec were measured in the study population. According to P50 ratio (amplitude to the test stimulus/amplitude to the conditioning stimulus), the subjects with P50 ratio less than 0.2 were defined as suppressed group (SG) ; non-suppressed group (NSG) consisted of P50 ratio more than 0.8. Thirty-five and 25 subjects were included in SG and NSG, respectively. Point-to-point correlation coefficients (PPCCs) of both groups were calculated between two time-windows : the first window (S1) was defined as the time-window of one hundred millisecond after the conditioning auditory stimulus and the second window (S2) was defined as the time-window of 100 msec after the test auditory stimulus. Spectral frequency analysis was performed to investigate which frequency band results in the difference of PPCC between SG and NSG. Results Significant reduction of PPCC between S1 and S2 was observed in the SG (Pearson's r = 0.24), compared to PPCC of the NSG (r = 0.58, p < 0.05). In spectral frequency analysis, gamma band showed "phase-reset" and similar responses after the two auditory stimuli in suppressed and non-suppressed group. However in the case of alpha band, comparison showed significantly low PPCC in SG (r = -0.14) compared to NSG (r = 0.36, p < 0.05). This may be reflecting "phase-out" of alpha band against gamma band at approximately 50 msecs after the test stimulus in the SG. Conclusions Our study suggests that normal P50 suppression is caused by phase-out of alpha band against gamma band after the second auditory stimulus. Thus it is demonstrated that normal sensory gating process is constituted with attenuated alpha power, superimposed on consistent gamma response. Implications of preserved gamma and decreased alpha band in sensory gating function are discussed.

Numerical simulation of infill CACB wall cracking subjected to wind loads

  • Ruige Li;Yu Gao;Hongjian Lin;Mingfeng Huang;Chenghui Wang;Zhongzhi Hu;Lingyi Jin
    • Structural Engineering and Mechanics
    • /
    • v.89 no.5
    • /
    • pp.479-489
    • /
    • 2024
  • The cracking mechanism in ceramsite aerated concrete block (CACB) infill walls were studied in low seismic fortification intensity coastal areas with frequent occurrence of typhoons. The inter-story drifts of an eight-story residential building under wind loads and a seismic fortification intensity of six degrees were analyzed by using the PKPM software. The maximum inter-story drift ratio of the structure in wind load was found to be comparable to that under the seismic fortification intensity of six degrees. However, when accounting for the large gust wind speed of typhoon, the maximum inter-story drift ratio was much larger than that obtained under reference wind load. In addition, the finite element models of RC frames were employed by displacement loading to simulate two scenarios with and without window hole in the CACB infill walls, respectively. The simulation results show no signs of cracking in both the infill walls with window hole and those without window for the inter-story drift caused by seismic loads and the reference wind load. However, both types of infill walls experienced structural creaking when assessing the gust wind pressure recorded from previous typhoon monitoring. It is concluded that an underestimate of wind loads may contribute substantially to the cracking of frame CACB infill walls in low seismic fortification intensity coastal areas. Consequently, it is imperative to adopt wind pressure values derived from gust wind speeds in the design of CACB infill walls within frame structures. Finally, the future research directions of avoiding cracks in CACB filled walls were proposed. They were the material performance improving and building structure optimizing.

The study on the Analysis of Useful Daylight Illuminance in rural standard house model - By Dynamic Daylight Simulation Using Weather Data - (농어촌주택 표준설계의 유용조도 분석에 관한 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Yun, Young Il;Song, Jeong Suk;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.47-55
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the Rural standard house models design process, because of lack of previous studies on elderly-light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

Causality change between Korea and other major equity markets

  • Kwon, Tae Yeon
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.4
    • /
    • pp.397-409
    • /
    • 2018
  • The world financial markets are inter-linked in ways that varies according to market and time. We examine the causality of change focusing on the Korean market as related to the U.S. (S&P 500), Japan (Nikkei 225), Hong-Kong (HSI), and European (DAX) markets. In order to capture time-varying causality running from and to the Korea stock market, we apply the Granger causality test under a VAR model with a wild bootstrap rolling-window approach. We also propose a new concept of a significant causality ratio to measure the intensity of the Granger causality in each time unit. There are many asymmetric strengths in mutual Granger causal relationships. Moreover, there are cases with significant Granger causal relations only in one direction. The period with the most severe Granger causality both running from and to the KOSPI market is the GFC. The market that formed the two-way Granger causal relationship with the KOSPI market for the longest period is the S&P 500. The HSI and DAX markets have the strongest two-way Granger causal relationship with the KOSPI shortly after 2000, and the Nikkei market had the strongest two-way Granger causal relationship with the KOSPI market before the Asian financial crisis.

The Study on the Analysis of Useful Daylight Illuminance in Care Facilities - By Dynamic Daylight Simulation Using Weather Data - (요양시설의 유용조도 분석에 관한 연구 -기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로-)

  • Yun, Youngil;Cho, Juyoung;Lee, Hyowon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the care facility design process, because of lack of previous studies on elderly- light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

A Weighted-window based Cache Replacement Policy for Streaming Cache Server (스트리밍 캐쉬 서버를 위한 가중치 윈도우 기반의 캐쉬 교체 정책)

  • 오재학;차호정;박병준
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.30 no.10
    • /
    • pp.556-568
    • /
    • 2003
  • This paper presents and analyzes the performance of a weighted-window based cache replacement policy for the efficient media caching in streaming media cache servers. The proposed policy makes, for each cached object, use of the reference count, reference time, amount of media delivered to clients and, in particular, the periodic patterns of user requests. Also, by giving weights to the recently referenced media contents, the replacement policy adequately and swiftly reflects the ever-changing characteristics of users preferences. The simulation studies show that the performance of the proposed policy has improved over the conventional policies such as LRU, LFU and SEG - in terms of hit ratio, byte hit ratio, delayed start and cache input.

A Study on performance comparison of frequency estimators for sinusoid (정현파 신호 주파수 추정 알고리즘의 추정 정확도 비교 연구)

  • Cho, Hyunjin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.6
    • /
    • pp.457-467
    • /
    • 2018
  • This paper presents performance comparison of several high-resolution frequency estimation algorithms for pure real tone signal. Algorithms are DFT (Discrete Fourier Transform - for reference purpose), Jacobsen, Candan, reassignment and Cedron. Each algorithm is evaluated under various experimental conditions, e.g., different SNR (Signal to Noise Ratio), window function and window length and performance is compared in the perspective of bias, MSE (Mean Square-Error) and variance. Experimental results indicate that Cedron algorithms works well in the most cases. For actual usage in the engineering problem, each algorithm needs additional analysis and modification.

A Study on Characteristics of Main Indoor Air Pollutants and Ventilation in Nursery Facilities (어린이집 실내공기 중 주요 오염물질의 특성 및 환기에 관한 연구)

  • Kim, Sang Cheol;Kang, Byeong-Chang;Lee, Sang-Uk;Kim, Gi-Doo;Seo, Won-Ho;Kim, Jong-Heon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.3
    • /
    • pp.245-250
    • /
    • 2014
  • As the number of nursery facilities and infants who stay there is continuously increasing, IAQ (Indoor Air Quality) of nursery facilities should be managed strictly and thoroughly because infants are more susceptible to infections due to their low resistivity. In this study the characteristics of IAQ and ventilation associated factors were investigaed for suggesting a desirable condition for IAQ management. Environmental factors were not much related to IAQ characteristics rather than internal factors such as structures of the room. And the positive effect of ventilation on IAQ was obvious and seemed to hinge on factors related to window area especially window/wall ratio. Results of this study indicate that the structure with broader window area of a room and frequnet ventilation can be an effective way for keeping IAQ of nursery facilities clean and safe.

A Study on the Window Glass Pressure for High-speed Train (고속철도차량의 유리창 압력에 관한 연구)

  • Kwon, Hyeok-Bin;Chang, Dae-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.4
    • /
    • pp.371-375
    • /
    • 2010
  • In order to decide the strength requirement of the window glass for the high-speed train, the pressure change during the passage of the EMU type high-speed train has been numerically simulated. Based on the calculation results, the pressure difference between the inner and outer pressure of the cabin has been calculated to yield the amount of load acting on the window glass of the cabin. To simulate the pressure field generated by the high-speed train passing through the tunnel, computational fluid dynamics based on the axi-symmetric Navier-Stokes equation has been employed. The pressure change inside a train has been calculated using first order difference approximation based on a linear equation between the pressure change ratio inside a train and the pressure difference of inside and outside of the train.