• Title/Summary/Keyword: Window ratio

Search Result 403, Processing Time 0.02 seconds

A Study on Facades of Buildings - The window area ratio distribution of building facade in Tokyo - (건물파사드에 관한 실측조사 연구 - 일본 동경지역의 벽체의 창면적비를 중심으로 -)

  • Kim, Chong-Min;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.71-80
    • /
    • 2003
  • The purpose of this study is to analyze the window area ratio distribution of building facade in Tokyo metropolitan area. The survey was carried out in Marunouchi, Kanda, Kasai and Todoriki district. The results of this study were as follows; to propose of window area ratio production method, analyzed and surveyed window area ratio of each district building-used and to compared every wall window area ratio of building. Every wall window area ratio of office district is $20\sim40%$, ones of non-office district is 15% or 35%. Residential area results are every wall window area ratio of apartment is 35%, ones of a house is 15%. To increase of office building to appear that Kanda, Kasai added window area ratio. But, Marunouchi, Todoriki wad not this tendency. Above mentioned results are made out database.

The verification about possibility of introducing Window to Floor Ratio as design index for building energy performance

  • Choi, Won-Ki;Lee, Yong-Jun;Lee, Hyun-Soo;Eom, Jae-Yong;Lee, Chung-Kook
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • Purpose: Many design index that are using in planning phase have been developed. The most popular things among them are Window to Wall Ratio and Surface to Volume Ratio. However there are some limits. Window to Wall Ratio cannot consider building size and Surface to Volume Ratio cannot do Window to Wall Ratio. Accordingly, in this paper, the Window to Floor Ratio was proposed that it can be considered both building size and Window to Wall Ratio. And analyzed correlation of energy demand. Method: For the test, 16 modules with the size of $6m{\times}6m{\times}4m$ were used to make 35 models with the same volume. The simulation was conducted to 945 cases using the window-to-wall ratio of 30, 50 and 70 % in three areas such as Seoul, Gwangju and Jeju and three kinds of windows. And IES_VE was used. Result: The findings above show that the Window to Floor Ratio that can be considered both building size and Window area have to become as design index. It was found out that design criteria with SHGC is necessary, not with the thermal performance (U-value). It is needed to additional analysis about residential building and the effect of 24-hours heating and cooling condition. It plans to carry out research to establish design indicators for climatic conditions in the country and building applications.

A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance (염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구)

  • Oh, Myung-Hwan;Sim, Se-Ra;Lee, Chul-Sung;Chin, Kyung-Il;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

Study on the Analysis of Energy Consumption Corresponding Window Area Ratio (건물 외피 창호면적 변화에 따른 에너지 소비량에 관한 연구)

  • Ha, Dae-Woong;Park, Kyung-Soon;Son, Won-Tug
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.857-862
    • /
    • 2008
  • Window is the most demanding design component in the building design. Recently, window area in the building surface has been increased significantly in the office building. As window area increased significantly, however, the thermal load has been increased significantly due to lack of thermal performance of the outside wall. In this paper, we discussed the energy consumption of the buildings according to window area ratio. Two types of building for energy consumption analysis were made by Designbuilder v.1.4 and Energyplus v.2.0. Window area ratio was five different types ($30%{\sim}70%$) in each building. As a result, the cooling energy consumption has been decreased as window area decreased in each building. Whereas the heating energy consumption has been increased window area decreased.

  • PDF

Robust Design Using Operating Window (기능창을 이용한 강건설계법)

  • Kim, Kyung-Mo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.1
    • /
    • pp.22-31
    • /
    • 2008
  • The operating window method is a novel approach in quality improvement. But it has not received deserved attention in academic research. If a critical factor for competing failure modes can be identified, the probability of failure can be reduced by widening the operating window of this factor. Traditional SN ratio for the operating window advocated by Taguchi has a critical shortcoming, which has been derived under the assumption that failure rates are determined by the operating window factor only. A new metric for robustness is given for the operating window method, which has relaxed the restrictive assumption of Taguchi's SN ratio. And procedures for determining optimal conditions based on the new metric is presented. The effectiveness of the proposed approach over the traditional practice is tested with the aid of a wave soldering process.

  • PDF

An Effect of the Change of Orientation and Window Area Ratio upon Building Energy Requirement in Apartment Housings (공동주택 향별 창면적비 변화에 따른 에너지 영향도 분석)

  • Kim, Jae Moon;Lee, Gyu Chul;Lee, Seung Gyu;Kim, Min Sung;Min, Joon Ki
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.21-26
    • /
    • 2013
  • Due to the increasing concerns about the buildings which have affected the global environment, most countries have enacted a regulation for the sustainability of domestic buildings. In 2008, the Korean government started to enact a regulation of apartment and office buildings for energy saving. Many research on the sustainable apartment building focuses on $84m^2$ or larger type in response to market demand; therefore, small size type such as $46m^2$ type needs to be researched. In addition, the research on the orientation and window to wall ratio of the building have been separately studied as a means of energy reduction; therefore, the research on correlation of the orientation and window to wall ratio hasn't been fully explored yet. This paper analyzes the energy demand of the apartment building as the change of orientation and window to wall ratio among $46m^2$ and $84m^2$ type. In conclusion, when reducing the window to wall ratio, energy demand was reduced, except when the orientation of the building was between from +10 to -20 from the south.

A Study on the Improvement of Adhesive Mixing Ratio about Acoustic Window for Enhancing SONAR Performance of Submarine (수중함 소나 수신성능 향상을 위한 음향창 접착제 배합비 개선)

  • Ham, Younghoon;Kim, Joonwoo;Chang, Hoseong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.481-488
    • /
    • 2018
  • This study suggest the improvement of the CFRP adhesive mixing ratio about acoustic window to enhance SONAR performance. The CFRP of submarine is produced by allocation an acoustic window zone by the beam width of SONAR sensors. During the sea trial, SONAR system's bearing and range accuracy data is not in tolerance due to debonding phenomenon on CFRP. The inappropriate mixing ratio of adhesives caused that peeling phenomenon occurred in the acoustic window part, which is the reason for the deterioration of SONAR sensors performance. The report includes explanation of test procedure of SONAR, root cause analysis, CFRP manufacturing procedure, laboratory tests results, and proof of the performance at the sea trial.

Appropriate Choice of Window Function for Noise Reduction (잡음 감소를 위한 창 함수의 선택에 관한 연구)

  • 백문열
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.3-8
    • /
    • 1997
  • This paper shows a performance estimation of windowing a single tone with added Gaussian noise and uniform noise. Signal-to-noise ratio can be determined by the ratio of the output noisy signal variance to the input noisy signal variance of a window. Standard deviation of noise is reduced by windowing Signal-to-noise ratio of the noisy signal is reduced by the windowing operation. Thus, performance of window function can be determined by this filtering operation that improved the signal-to-noise ratio.

  • PDF

Study on Estimate of Window Condensation performance Due to Temperature Depreciation Ratio (표면 온도 저하율에 따른 창호부 결로성능 예측에 관한 연구)

  • Sung, Uk-Joo;Cho, Soo;Jang, Cheul-Yong;Lee, Jin-Seong;Peak, Sang-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1255-1260
    • /
    • 2006
  • This present study analyzed temperature depreciation ratio of window inside surface by KS F 2295 'Procedure for determining fenestration product condensation resistance values'. it estimated window indoor surface condensation due to variable environmental condition. Performance of condensation resistance by using temperature depreciation ratio until applied Low-e and Ar glazing improved about 45% from 24 mm clear. Temperature depreciation ratio by KS F 2295 considers analytic index of window condensation due to variable boundary condition.

  • PDF

Luminance Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 휘도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room