• Title/Summary/Keyword: Window Effect

Search Result 741, Processing Time 0.03 seconds

Effect of Observation Window at Peripheral Intravenous Catheter Site on Early Recognition of Infiltration among Hospitalized Children (아동의 말초정맥관 삽입 부위 관찰창 확보가 침윤조기감지에 미치는 효과)

  • Jeong, Ihn Sook;Park, Soon Mi;Park, Kyung Ju
    • Journal of Korean Academy of Nursing
    • /
    • v.46 no.4
    • /
    • pp.534-541
    • /
    • 2016
  • Purpose: The aim of this study was to identify the effect of an observation window (OW) at peripheral intravenous (IV) catheter sites on early detection of IV infiltration among hospitalized children. Methods: This was a retrospective observational study with history control group design. Participants were children who had IV infiltration after peripheral catheterization when hospitalized from January to May, 2014 and January to May, 2015 at a children's hospital located in Yangsan city, Korea. The 193 patients, who were hospitalized from January to May, 2014 formed the control group and did not have OW, and the 167 patients, who were hospitalized from January to May, 2015 formed the window group and had OW. Data were analyzed using ${\chi}^2$-test, independent samples t-test and multiple logistic regression. Results: First stage IV infiltration was 39.5% for the window group and 25.9% for the control group, which was significantly different (p=.007). The likelihood of $2^{nd}$ stage and above IV infiltration decreased by 44% in the window group, which was significantly different (p=.014). Conclusion: OW at the peripheral IV catheter site was found to be an effective measure in early recognition of IV infiltration. Considering the effect of OW, we recommend that nurses should make an OW with transparent dressing during stabilization of the IV catheter site in hospitalized children in clinical settings.

A Numerical and Experimental Study of Heat Transfer through a Double Pane Window to Enhance Thermal Insulation of Building (건물 에너지 절약을 위한 수치해석적/실험적 이중창 열전달 연구)

  • 장동순;송은영;이상일
    • Journal of Energy Engineering
    • /
    • v.1 no.1
    • /
    • pp.66-75
    • /
    • 1992
  • The performance of heat transfer through double pane window has been investigated using experimental and numerical methods. The range of the gap distance between glasses are 0.5-10 cm. The convection heat transfer plays the dominant role for the case of the wide gap distance together with the large Rayleigh number and thereby, reduces the enhanced thermal resistance due to the increased air gap, while the conduction heat transfer does the major role for the case of small gap distance. In order to enhance the thermal insulation of the double pane window, the heat transfer of triple pane window, which is constructed to put one more glass at the middle of the double pane, is investigated to check the reduction of the convection heat transfer together with the effect of the radiation shield due to the presence of the additional glass. Further, a spacer is installed at the middle height of the double pane, and the effect of which on the suppression of the convective heat transfer is analyzed carefully, using experimental and numerical methods. For the case of the spacer-installation, the amount of energy saving is considered about 10%, but the energy saving increases a lot to 30-50% for the case of triple pane window, due to the substantial radiation shield effect of the presence of the additional glass.

  • PDF

The Impact of Window Information Effect on Consumers' Willingness to Visit a Fashion Store -Focusing on Group Differences by Clothing Shopping Orientation- (패션제품의 윈도우 정보효과가 점포 방문의사결정에 미치는 영향 -의복쇼핑성향에 따른 집단간 차이를 중심으로-)

  • Jeon, Min-Ji;Oh, Hee-Sun;Suh, Yong-Han
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.9_10 s.157
    • /
    • pp.1423-1433
    • /
    • 2006
  • The purpose of this study is to explore the impact of window information on consumers' willingness to visit a fashion store according to their clothing shopping orientation. The sutjects of the research are conveniently selected females over the age of 20 living in Busan. A total of 202 questionnaire are collected far data analysis. The results of this study are as follows: 1. The factor analysis to identify the clothing shopping orientation showed four factors, such as hedonic, planned, independent/loyalty, and impulsive/convenience. A cluster analysis conducted by the four factors resulted in four patterns - utilitarian shopping orientation group, impulsive/convenience shopping orientation group, hedonic shopping orientation group, independent/loyalty shopping orientation group. 2. The window information conducted by factor analysis were divided into the four levels-product information, promotion information, fashion information, and store image. 3. A one-way ANOVA analysis carried out to find the window information effects among the groups revealed that there were significant differences in the factors of promotion information, fashion information, and store image. 4. Multi-regression analysis was conducted in order to find the impact of window information on the consumers' willingness to visit a fashion store. As a result, fashion information had the most impact on utilitarian shopping group, while product information, promotion information and store image had a great impact on impulsive/convenience shopping orientation group, fashion information and store image had the most impact on hedonic shopping orientation group.

Assessment of The Luminance Distribution from Daylighting window by Using Image Processing Methodology (이미지 프로세싱 기법을 활용한 채광창의 휘도분포 평가)

  • Park, Jong Myung;Lim, Hong Soo;Kim, Jeong Tai;Kim, Gon
    • KIEAE Journal
    • /
    • v.12 no.5
    • /
    • pp.77-84
    • /
    • 2012
  • Daylighting is the controlled admission of natural light into a space, reducing electric lighting and saving energy. By providing a direct link to the dynamic and perpetually evolving patterns of outdoor illumination, daylighting helps create a visually stimulating and comfort environment for building occupants, while reducing energy costs. Especially, however, glare is the most important factor in daylighting, which is issued by incoming direct sunlight into windows. This study analyzed the discomfort glare on a daylighting window by using Image processing methodology and found a solution to problems with glare source of occupants. There are several ways to evaluate discomfort glare such as UGR (Unified Glare Rating) of CIE, DGI (Daylight Glare Index, Hopkinson, 1972) and VCP (Visual Comfort Probability) of IES. These are used to apply to the relatively little artificial light source and they cannot cover discomfort glare from a real daylighting window. In this regarding, this paper aimed to calculate DGI index of the real daylighting window in a experimental space by using image processing methodology. The variables and outcomes are luminance distribution of non-shading window, effect of venetian blind installed on the window and locations related to position index of DGI.

An Effect of the Change of Orientation and Window Area Ratio upon Building Energy Requirement in Apartment Housings (공동주택 향별 창면적비 변화에 따른 에너지 영향도 분석)

  • Kim, Jae Moon;Lee, Gyu Chul;Lee, Seung Gyu;Kim, Min Sung;Min, Joon Ki
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.21-26
    • /
    • 2013
  • Due to the increasing concerns about the buildings which have affected the global environment, most countries have enacted a regulation for the sustainability of domestic buildings. In 2008, the Korean government started to enact a regulation of apartment and office buildings for energy saving. Many research on the sustainable apartment building focuses on $84m^2$ or larger type in response to market demand; therefore, small size type such as $46m^2$ type needs to be researched. In addition, the research on the orientation and window to wall ratio of the building have been separately studied as a means of energy reduction; therefore, the research on correlation of the orientation and window to wall ratio hasn't been fully explored yet. This paper analyzes the energy demand of the apartment building as the change of orientation and window to wall ratio among $46m^2$ and $84m^2$ type. In conclusion, when reducing the window to wall ratio, energy demand was reduced, except when the orientation of the building was between from +10 to -20 from the south.

Numerical Analysis of Borehole Stability Depending on Drilling Fluid (Drilling Fluid를 적용한 시추공의 안정성에 대한 수치해석)

  • Sin, Chun-won;Yoo, Chung-Sik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.183-194
    • /
    • 2017
  • When a borehole is drilled, the load distributed by the removal is taken to re-establish equilibrium. As a result, the stresses around the borehole is redistributed. If there is no hydrostatic support pressure by drilling fluid (mud) introduced into the borehole, failure in the formation may take place. The mud pressure boundary that keeps the borehole stable is defined as a mud window. To predict the potential for failures around the borehole, a series of numerical analysis were performed and compared with a mud window. The effect of failure criterion and the intial stress ratio adopted on the mud window was also studied.

Study of Damage in Germanium Optical Window Irradiated by a Near-infrared Continuous Wave Laser (근적외선 연속발진 레이저 조사에 의한 게르마늄 광학창 손상 연구)

  • Lee, Kwang Hyun;Shin, Wan-Soon;Kang, Eung-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.82-89
    • /
    • 2014
  • The damage in germanium (Ge) optical window irradiated by a near-infrared continuous wave (CW) laser was studied. Laser-induced heating and melting process were surveyed, and the specific laser power and the irradiance time to melt were estimated by numerical simulation. The experiments were also carried out to investigate the macro and micro structure change on Ge window. Results showed that the surface deformation was formed by melting and resolidification process, the damaged surface had a polycrystalline phase, and the transmittance as an optical performance factor in mid-infrared region was decreased. We confirmed that an abnormal polycrystalline phase and surface deformation effect such as hillock formation and roughness increase reduced the transmittance of Ge window and were the damage mechanism of CW laser induced damage on Ge window.

Active Window to Reduce the Exterior Noise Flowed Through the Open Window (열린 창문을 통해 유입되는 소음을 저감하는 능동소음제어 창문)

  • Kwon, Byoung-Ho;Park, Young-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.820-827
    • /
    • 2011
  • Recently, noise has been regarded as one of the most notorious and frequent environmental pollutions which can be often encountered not only in the living space but also in the industrial site. Studies on physiological and psychological effects of long-term noise exposure to human being have commanded the public interest on noise issues. Since environmental noises such as traffic noise and construction noise is mainly flowed through the open window, it is necessary to develop the active noise control system to reduce it inside the building. Although control speakers and microphones for the noise signal measurement in the control region are essential for the conventional active noise control methods, it is impossible to implement them in the control region in the building environment because the control region is the living quarter and they may hinder activities of the residents. Therefore, we proposed the active window system to reduce the exterior noise flowed through the open window with microphones installed outside the window and control speakers installed at the frame of the window. To confirm the performance of the proposed active window, we carried out the simulation and experiment using active window system with 8 control speakers. Simulation results showed the noticeable noise reduction effect inside the control region within the frequency range without the spatial aliasing. Experimental result showed that the total acoustic potential energy inside the room of the scale model is reduced to about 10dB within the interest of frequency range.

Computationally Efficient Sliding Window BCJR Decoding Algorithms For Turbo Codes (터보 코드의 복호화를 위한 계산량을 줄인 슬라이딩 윈도우 BCJR 알고리즘)

  • 곽지혜;양우석;김형명
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8A
    • /
    • pp.1218-1226
    • /
    • 1999
  • In decoding the turbo codes, the sliding window BCJR algorthm, derived from the BCJR algorithm, permits a continuous decoding of the coded sequence without requiring trellis fermination of the constituent codes and uses reduced memory span. However, the number of computation required is greater than that of BCJR algorithm and no study on the effect of the window length has been reported. In this paper, we propose an eddicient sliding window type scheme which maintains the advantages of the conventional sliding window algorithm, reduces its computational burdens, and improves is BER performance. A guideline is first presented to determine the proper window length and then a computationally efficient sliding window BCJR algorithm is obtained by allowing the window to be forwarded in multi-step. Simulation results show that the proposed scheme outperforms the conventional sliding window BCJR algorithm with reduced complexity. It gains 0.1dB SNR improvements over the conventional method for the constraint length 3 and BER $10^{-4}$

  • PDF

A Experimental Study on the Influence of the Display Effect by Color and Light Source in Show Window (색채와 광원이 쇼윈도 전시효과에 미치는 영향)

  • 이정옥;김현지
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.4
    • /
    • pp.49-54
    • /
    • 1995
  • This paper is an experimental study on the influence of the demonstration effect by color and light source in show window. This experiment used semantic differentical method in model show window of actual size. The important outcomes of this study are summarized below. 1. In the result by factor analysis, three factors are classified. They are diversity, emotion, lightness. 2. In the study on the influence by light source, incandescence lamp is the most effective light source in every items. 3. In the result of the study on the influence by color source, according to each factor bring out following result ; Green is the most effective in diversity factor and ligthness factor. Yellow is the most effective in emotion factor.

  • PDF