• Title/Summary/Keyword: Window Contamination

Search Result 22, Processing Time 0.026 seconds

The Development of the Contamination Prevention Module of an Optical Window Using Ultrasonic Waves (초음파를 이용한 광학창 오염방지 모듈 개발)

  • Lee, ChangHee;Jeon, KiMun;Shin, JaeSoo;Yun, JuYoung;Cho, Seonghyun;Kang, Sang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.4
    • /
    • pp.175-180
    • /
    • 2013
  • We developed the contamination prevention module of an optical window for an In-Situ Particle Monitor (ISPM) system. the core part of the module is the generator of an ultrasonic wave and the module is to remove particles stuck to the window by the transfer of the wave force to the window surface. In order to enhance transfer efficiency of the waves the frequency of the ultrasonic wave was optimized and a low impedance material (plexiglass) and a soft sealing material (Si rubber) were used. The ISPM with the developed module was installed at the exhaust line of a BPSG CVD equipment and the effect of the module was verified.

A Study on the amount of Co gas in the kitchen related to facility enviromental condition and fuel management (부엌공기 중에 함유되어 있는 가스량과 부엌 구조시설 연료관리와의 관계에 대한 연구)

  • 장명욱
    • Journal of the Korean Home Economics Association
    • /
    • v.8 no.1
    • /
    • pp.146-158
    • /
    • 1970
  • It is a matter of amazing to realize that contamination of air by fuel gas in recent daily life at home directly effects to health of Korean housewives. A study in finding the status and the amount of co gas in the kitchen was con-ductedrelating the size of kitchen, door of exit, ventilation window, constraction of built in-brick stove (Boo Tu Mack), fuel management, in order to extend beneficial and improved management of housing. From the result of study, it was pointed out that constractional improvement of built-in-brick stove, heating floor (Ondol), timny, and ventilation window would been emergently needed. Demonstration studies were obtained in finding differences of the amount of co gas respectively in cooking time as 50-55ppm, and in not cooking time as 50-80p,p,m in the kitchen both, original and improved. Definite differences were found depend upon the condition with, without, or direction of the ventilation window. In addition to all above results, significant influence on gas pulling power of Ondol tunnel was shown. Many houses of Apartment house for have middle and low income groups been recognized so poor for health as indicated over 100ppm of co gas if window were not opened because of poor ventilation and weak gas pulling power of Ondol tunnel.

  • PDF

A Study on the Statistical Predictability of Drinking Water Qualities for Contamination Warning System (수질오염 감시체계 구축을 위한 수질 데이터의 통계적 예측 가능성 검토)

  • Park, No-Suk;Lee, Young-Joo;Chae, Seonha;Yoon, Sukmin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.4
    • /
    • pp.469-479
    • /
    • 2015
  • This study have been conducted to analyze the feasibility of establishing Contamination Warning System(CWS) that is capable of monitoring early natural or intentional water quality accidents, and providing active and quick responses for domestic C_water supply system. In order to evaluate the water quality data set, pH, turbidity and free residual chlorine concentration data were collected and each statistical value(mean, variation, range) was calculated, then the seasonal variability of those were analyzed using the independent t-test. From the results of analyzing the distribution of outliers in the measurement data using a high-pass filter, it could be confirmed that a lot of lower outliers appeared due to data missing. In addition, linear filter model based on autoregressive model(AR(1) and AR(2)) was applied for the state estimation of each water quality data set. From the results of analyzing the variability of the autocorrelation coefficient structure according to the change of window size(6hours~48hours), at least the window size longer than 12hours should be necessary for estimating the state of water quality data satisfactorily.

A Study of the Mask and Hand Contamination in Dental Clinic (치과에서의 마스크 및 손의 미생물 오염정도 비교)

  • Pyo, Eunji;Lee, Kyunghee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.3
    • /
    • pp.85-94
    • /
    • 2019
  • Purpose: The purpose of this study was to observe the degree of mask contamination in dental hygienist for general and oral bacteria and to identify areas of mask contamination after treatment. Methods: Masks were collected with every fifty dental hygienists who currently working in the department of preventive dentistry, prosthodontics, and orthodontics in Busan. The mask bacteria were collected in specific upper and side parts of the mask. Hand germs were collected using sterile cotton swabs, and then placed in a sterile conical tube. These were transferred to the laboratory. Hand germs and mask bacteria were incubated with nutrient broth (NB) and brain heart infusion broth (BHI) for 24 hrs and each cultured with NB and BHI plate at $37^{\circ}C$ for 48 hrs. Collected data were analyzed using the SPSS Window 20. Results: The number of bacteria was observed in the order of the department of preventive dentistry ($10.1{\times}10^5CFU/ml$), prosthodontics ($14.7{\times}10^5CFU/ml$), and orthodontics ($23.3{\times}10^5CFU/ml$) in the hand. In general bacteria, the difference of contamination was seen by the parts of the mask, but there was no significant difference. However, the oral bacteria were observed highly contaminated upper part of the mask in preventive dentistry. The mask contamination according to the medical departments was observed. Especially, the contamination of mask in preventive dentistry was significantly higher than other departments in oral bacteria. Conclusion: This study suggested that correct mask replacement and recognition of contamination areas can contribute to the prevention of infectious disease. and it would be necessary to increase hand hygiene performance to prevent cross-infection with masks. Also, this study may give an idea for making guidelines for mask management and supporting to establish clear criteria for the education program of personal protective equipment.

CONSTRUCTING DAILY 8KM NDVI DATASET FROM 1982 TO 2000 OVER EURASIA

  • Suzuki Rikie;Kondoh Akihiko
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.18-21
    • /
    • 2005
  • The impact of the interannual climatic variability on the vegetation sensitively appears in the timing of phenological events such as green-up, mature, and senescence. Therefore, an accurate and temporally high-resolution NDVI dataset will be required for analysis on the interannual variability of the climate-vegetation relationship. We constructed a daily 8km NDVI dataset over Eurasia based on the 8km tiled data of Pathfinder A VHRR Land (PAL) Global daily product. Cloud contamination was successfully reduced by Temporal Window Operation (TWO), which is a method to find optimized upper envelop line of the NDVI seasonal change. Based on the daily NDVI time series from 1982 to 2000, an accurate (daily) interannual change of the phenological events will be analyzed.

  • PDF

A STUDY OF SHEAR BOND STRENGTH OF ORTHODONTIC BRACKET UNDER BLOOD-CONTAMINATED CONDITIONS (혈액 오염 환경 하에서 접착된 교정용 브라켓의 전단 강도에 관한 연구)

  • Shin, Ji-Sun;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.191-199
    • /
    • 2005
  • This study was experienced in order to obtain the shear bond strength of orthodontic bracket adhesives under the blood contamination that can be occurred during the procedure of bracket bonding under window opening surgery. As a result of this study, shear bond strength of all glass ionomer groups were lower than resin cement groups. However, the strength of uncontaminated and post-contaminated group of glass ionomer was strong enough to perform an orthodontic forced eruption. This study revealed that during a window opening surgery, glass ionomer without etching procedure is available in order to bond a bracket if surface of teeth is not pre-contaminated by blood before the adhesive application. Both simple procedure and less adhesives remnant after bonding failure could make light-cured glass ionomer cement the ultimate choice for racket bonding.

  • PDF

Assembly Neutron Moderation System for BNCT Based on a 252Cf Neutron Source

  • Gheisari, Rouhollah;Mohammadi, Habib
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.101-105
    • /
    • 2018
  • In this paper, a neutron moderation system for boron neutron capture therapy (BNCT) based on a $^{252}Cf$ neutron source is proposed. Different materials have been studied in order to produce a high percentage of epithermal neutrons. A moderator with a construction mixture of $AlF_3$ and Al, three reflectors of $Al_2O_3$, BeO, graphite, and seven filters (Bi, Cu, Fe, Pb, Ti, a two-layer filter of Ti+Bi, and a two-layer filter of Ti+Pb) is considered. The MCNPX simulation code has been used to calculate the neutron and gamma flux at the output window of the neutronic system. The results show that the epithermal neutron flux is relatively high for four filters: Ti+Pb, Ti+Bi, Bi, and Ti. However, a layer of Ti cannot reduce the contribution of ${\gamma}$-rays at the output window. Although the neutron spectra filtered by the Ti+Bi and Ti+Pb overlap, a large fraction of neutrons (74.95%) has epithermal energy when the Ti+Pb is used as a filter. However, the percentages of the fast and thermal neutrons are 25% and 0.5%, respectively. The Bi layer provides a relatively low epithermal neutron flux. Moreover, an assembly configuration of 30% $AlF_3+70%$ Al moderator/$Al_2O_3$ reflector/a two-layer filter of Ti+Pb reduces the fast neutron flux at the output port much more than other assembly combinations. In comparison with a recent model suggested by Ghassoun et al., the proposed neutron moderation system provides a higher epithermal flux with a relatively low contamination of gamma rays.

Sensor-based Motion Planning Algorithm for High-rise Building Facade Cleaning of Built-in Guide Type Multi-Robot (Built-in guide 타입 다중 로봇의 고층 빌딩 외벽 청소를 위한 센서 기반 운동 계획 알고리즘)

  • Lee, Seung-Hoon;Kim, Dong-Hyung;Kang, Min-Sung;Gil, Myung-Soo;Kim, Young-Soo;Back, Sung-Hoon;Han, Chang-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.5
    • /
    • pp.445-452
    • /
    • 2012
  • With the increasing number of high-rise and large-scale buildings, modern buildings are becoming intelligent, and are incurring high construction costs and requiring careful maintenance. Maintenance works for high-rise buildings significantly depend on human labor, unlike other construction processes that are gradually being automated. The resulting accidents may produce very high social and economic losses. To address this problem, herein, this paper proposes robotic building maintenance system using multi-robot concept, in specific, cleaning a building facade which is directly subjected to minimize human labor; that improves the process efficiency and economic feasibility. The sensor for detecting contamination of building's outer-wall glass is proposed; Kalman filter was used for estimating robots' status with the contamination of the window glass. Task allocation of the sensor based multi-robots for an effective way of task execution is introduced and the feasibility was verified through the simulations.

Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter (Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석)

  • Jang, Ji-Yong;Jeong, Moon-Taeg;Song, Jong-Nam;Ha, Jae-Jun;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.31-37
    • /
    • 2018
  • In the surface contamination test using the end-window Geiger-Muller type counter, the wrap is used as a method for protecting the detector exposed to the outside in order to measure the beta-rays. We analyze the effect of this method on the measurement rate and the correction factor, and wanted to make it clear to radiation workers that excessive use of the wrap can affect the measured value of the beta-rays. The experimental method was to compare and analyze the change of the beta-rays measurement counting rate and the calibration factor according to the wrap thickness using the beta-rays with different energy of 3 KBq, 1.5 KBq and 0.3 KBq. The subjects of this study were the end-window Geiger-Muller type counter which were held at the calibration center certified by Korea Laboratory Accreditation Scheme (KOLAS) in March 2012, Cl-36 (Chlorine) and Sr-90 (Strontium) were used as the source of beta radiation. The measurement counting rate decreased with increasing wrap thickness, and the calibration factor increased with increasing wrap thickness. Since the changes of the measurement counting rate and the calibration factors can reduce the accuracy of the instrument readings, but also have a significant impact on detector contamination and damage, so there is a need to find out what thickness of wrap is most effective. If we using a wraps with thickness that show a low rate of change of the measurement counting rate and the calibration factor, it will protect the detector and minimize the effect on the measured value of the beta-rays.