• 제목/요약/키워드: Wind loads

검색결과 938건 처리시간 0.025초

건축 구조물에 대한 능력스펙트럼법의 정확성 연구 (Accuracy of Capacity Spectrum Method for Building Structures)

  • 민경원;이상현;박민규;이영철;정란
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.27-34
    • /
    • 2003
  • Capacity Spectrum Method (CSM) defined in ATC-40 or FEMA-273 is a most widely used static inelastic analysis method to evaluate the performance level of the existing structures. In CSM, however, uncertainties and errors exist when lateral forces such as earthquake and wind loads are analyzed into equivalent static loads. This paper examines the accuracy of CSM for different structural parameters, such as natural frequency, yield strength and hardening ratio, and various soil conditions by comparing the estimated values to exact solutions obtained by time history analysis. Results indicate that the accuracy of CSM, in general, is influenced mostly by hardening ratio.

  • PDF

TMD를 이용한 서해대교 가로등의 진동제어 (Vibration control of lamp posts in Seohae Bridge using TMD)

  • 박찬민;박종칠;황성호;김용길;권오병
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.252-256
    • /
    • 2003
  • Tuned Mass Damper(TMD) has been applied in various fields in order to mitigate these vibrations. The shape or configuration of TMDs being unrestricted, a large panel of designs is possible to improve their effectiveness and economical-efficiency, where ingenuity plays an essential role and is required. This study presents an application of a new-type TMD on lamp posts to reduce vibrations induced by loads with large frequency domains such as wind loads. It is shown that the proposed TMD absorbs efficiently the energy without being restricted by frequency contents of the vibration.

  • PDF

Ultimate strength of long-span buildings with P.E.B (Pre-Engineered Building) system

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1483-1499
    • /
    • 2015
  • With the improvement of the quality of construction materials and the development of construction technologies, large-scale long-span steel frame buildings have been built recently. The P.E.B system using tapered members is being employed as an economically-efficient long-span structure owing to its advantage of being able to distribute stress appropriately depending on the size of sectional areas of members. However, in December 2005 and in February 2014, P.E.B buildings collapsed due to sudden loads such as snow loads and wind gusts. In this study, the design and construction of the P.E.B system in Korea were analyzed and its structural safety was evaluated using the finite element analysis program to suggest how to improve the P.E.B system in order to promote the efficient and rational application of the system.

해양 수직 파일(Vertical Pile)에 작용하는 환경 하중하의 응력 해석 기법 비교 (Comparison of stress analysis tools for ocean vertical pile under environmental loads)

  • 조철희;김병환;김두홍
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.121-127
    • /
    • 2001
  • To investigate the stability and integrity of offshore structures, it is necessary to estimates the significant ocean environmental loadings. They include hydrostatic pressure, wind, wave, current, tide, ice, earthquake, temperature, marine growth and scouring. Waves are of major importance among them because of the large forces acting on submerged parts of the structure caused by accompanying water motions. For the comparison of stress and deflection analysis tools, a vertical pile is applied under environmental loads. The analysis is concerned with SACS(Structural Analysis Computer System), ANSYS and C program. SACS and C program have nearly the same results but not ANSYS. This study shows the comparison of results obtained from 3 different approaches.

  • PDF

케이블댐퍼 감쇠성능의 수치해석적 연구 (Numerical Analysis Study on Damping Performance of Cable Damper)

  • 임성순
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.97-104
    • /
    • 2015
  • Compared with a strong axial rigidity due to large intial tension, cable has a weak laterally flexural rigidity. A variety of dynamic loads such as traffic loads and wind loads etc. cause the cables to vibrate significantly and affect the mechanical properties and the performance of cables. Therefore, vibration reduction design is an urgent task to control the vibration of cable-supported bridges. Because a various kind of dampers have shown to reduce the amplitude and duration time of vibration of cable from measured date in field test, damper can be considered that it is effective device significantly to reduce the amplitude and duration time in vibration of cable. Vibration characteristics of cable can change according to manufacturing method and type of established form, and damper has been designed according to distribution of natural frequencies and vibration modes. In this study, numerical analysis is used to show the reduction effects of vibrations and present the design of damper for vibration reduction of cable.

구조물 진동제어를 위한 전자석구동 HMD의 응용에 관한 연구 (A study on the Application of Electromagnetic Type HMD for Vibration Control of Structure)

  • 최현;정정교;김두훈;이상조
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.280-285
    • /
    • 2000
  • With recent development of technology of high stiffness material and the structural design, the construction of high rise structures such as tall building, tower has increased. The more flexible and slender structure is vulnerable to the internal and external dynamic loads induced by earthquake, wind and traffic load. There have been great effort and many researches to minimize the influence of dynamic loads on the structure. The traditional and stable method, the application of the passive damper, is not able to comply with various dynamic loads, while the mass damper which active control technology is integrated can effectively comply with load types. Therefore, the application of active control of huge structures with AMD(Active mass damper) or HMD(Hybrid Mass damper) is increasing. Up to now, most of actuators are servomotor and hydraulic actuator. But it is known that the electromagnetic actuator applies non contacting control force, which makes the control system easier with no characteristic change depending on time. In this paper, Hybrid mass damper with electromagnetic actuator was designed and applied to building scaled structure. The performance of designed HMD tested by shake table test is included.

  • PDF

교량 케이슨 운송의 동적 안정성 고찰 (Dynamic Stability during Transportation of Bridge Caisson)

  • 조철희;김성준;정현
    • 한국해양공학회지
    • /
    • 제23권1호
    • /
    • pp.104-108
    • /
    • 2009
  • As the demands of ocean resource development increase, many offshore structures are required. To cope with the active ocean developments, many types of construction methods have been applied for offshore facilities, including oil, gas and harbors. One of the challenges is to transport and install the heave bridge caisson. Several construction methods are well understood. However, for the sake of safety and reliability, the F/D installation method can be utilized. While the caisson is carried by an F/D, the mooring force of the tug boat and the structure stability from exiting motions in the dock should be checked against external loadings and sea conditions. The external loads can be classified with wind force, current force, and wave force. In the stability analysis, transportation velocity and draft of F/D are important factors. The dynamic stability and hook load for crane barge installation for the same caisson are also studied. Considering external loads and dominant factors, the stability of caisson during transportation has been investigated.

교량상부에 부착된 구조물의 동적거동해석 (Dynamic Evaluation of Bridge Mounted Structures)

  • 김동주;이완수;양종호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.324-327
    • /
    • 2011
  • The design requirement for ground mounted sign structures are fairly well defined in the AASHTO Standard Specifications for Structural Supports for Highway Signs, Luminaries, and Traffic Signals and consists of applying an equivalent pseudo-dynamic loading to account for the dynamic effects of wind loads and ignores the dynamic effect due to moving vehicle loads. This design approach, however, should not be applied to the design of bridge mounted sign structures because ignoring the dynamic effects of the moving vehicle loads may produce non-conservative results, since the stiffness of the bridge structure can greatly influence the behavior. Not enough information is available in the literatures which provide guide lines to include the influence of moving vehicles in the design of the bridge mounted sign structures. This paper describes a theoretical methodology, Bridge-Vehicle Interaction Element, which can be utilized to account for the dynamic effect of moving vehicles. A case study is also included where this methodology was successfully applied. It was concluded that the bridge-vehicle interaction finite element developed can provide a more accurate representation of the behavior of bridge mounted sign structures. The result of these analysis enabled development of simple and effective retrofitting scheme for the existing support system of bridge-mounted-structure.

  • PDF

주상 복합 구조물에 적용된 중간층 면진 시스템의 성능 검토 (Control Performance Evaluation of Mid-Story Isolation System for Residence-Commerce Complex Building)

  • 박광섭;김윤태;김현수
    • 한국공간구조학회논문집
    • /
    • 제19권3호
    • /
    • pp.33-40
    • /
    • 2019
  • A seismic isolation system is one of the most effective control devices used for mitigating the structural responses due to earthquake loads. This system is generally used as a type of base isolation system for low- and mid-rise building structures. If the base isolation technique is applied to high-rise buildings, a lot of problems may be induced such as the movement of isolation bearings during severe wind loads, the stability problem of bearings under large compression forces. Therefore, a mid-story isolation system was proposed for seismic protection of high-rise buildings. Residence-commerce complex buildings in Korea have vertical irregularity because shear wall type and frame type structures are vertically connected. This problem can be also solved by the mid-story isolation system. An effective analytical method using super elements and substructures was proposed in this study. This method was used to investigate control performance of mid-story isolation system for residence-commerce complex buildings subjected to seismic loads. Based on numerical analyses, it was shown that the mid-story isolation system can effectively reduce seismic responses of residence-commerce complex tall buildings.

2축 동조 질량 감쇠기를 이용한 구조물의 진동 제어 연구 (A Study of the Structural Vibration Control Using a Biaxial Tuned Mass Damper)

  • 정태영
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.473-481
    • /
    • 2000
  • Civil structures are becoming more flexible and lightly damped. When subjected to dynamic loads such as wind, earthquake and wave, vibration may be easily induced and lasted for lond duration. To suppress the wind-induced and earthquake-induced vibration of high-rise buildings, study on the development of a tuned mass damper has been carried out. Based on optimal design on passive tuned mass damper which is considered for a building subject to random excitations, a biaxial tuned mass damper was designed and developed. It is confirmed that the vibration levels of the test structure are reduced using the developed tuned mass damper.

  • PDF