• 제목/요약/키워드: Wind Power density

검색결과 205건 처리시간 0.023초

A linear model for structures with Tuned Mass Dampers

  • Ricciardelli, Francesco
    • Wind and Structures
    • /
    • 제2권3호
    • /
    • pp.151-171
    • /
    • 1999
  • In its 90 years of life, the Tuned Mass Damper have found application in many fields of engineering as a vibration reducing device. The evolution of the theory of TMDs is briefly outlined in the paper. A generalised mathematical linear model for the analysis of the response of line-like structures with TMDs is presented. The system matrices of the system including the TMDs are written in the state space as a function of the mean wind speed. The stability of the system can be analysed and the Power Spectral Density Function of any response parameter calculated, taking into account an arbitrary number of modes of vibration as well as an arbitrary number of TMDs, for any given PSDF of the excitation. The procedure can be used to optimise the number, position and mechanical properties of the damping devices, with respect to any response parameter. Due to the stationarity of the excitation, the method is well suited to structures subjected to the wind action. In particular the procedure allows the calculation of the onset galloping wind speed and the response to buffeting, and a linearisation of the aeroelastic behaviour allows its use also for the evaluation of the response to vortex shedding. Finally three examples illustrate the suggested procedure.

북한 지역에서의 30년 동안의 평균 바람 지도 (A 30-year Average Wind Map in North Korea)

  • 서은경;윤준희;박영산
    • 한국지구과학회지
    • /
    • 제30권7호
    • /
    • pp.845-854
    • /
    • 2009
  • 북한의 풍력발전 가능성을 조사하기 위한 첫 단계로 북한 지역에서의 30년 동안의 27개 지점의 지상관측자료 중 풍속과 풍향 자료를 이용하여 이 지역에서의 기후학적 바람 자원을 분석하였다. 바람자원 분석을 위해 풍속의 확률 밀도함수를 Weibull 함수로 가정하여 접근하였다. 지표로부터 50 m 고도에서 연중 평균 풍속이 4.0 m/s 이상인 지역은 대체적으로 개마고원 지역과 황해도 해안 지역이었다. 이 지역들은 비교적 바람 자원이 풍부한 것으로 나타났다. 풍속이 5 m/s 이상을 유지하는 지속시간이 가장 긴 계절은 봄이었고, 짧은 계절은 여름이었다. 관측 지점 중 장진과 양덕이 지속시간이 가장 길고 평균 풍속도 가장 큰 곳이었다.

Spectral Analysis of Geomagnetic Activity Indices and Solar Wind Parameters

  • Kim, Jung-Hee;Chang, Heon-Young
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권2호
    • /
    • pp.159-167
    • /
    • 2014
  • Solar variability is widely known to affect the interplanetary space and in turn the Earth's electromagnetical environment on the basis of common periodicities in the solar and geomagnetic activity indices. The goal of this study is twofold. Firstly, we attempt to associate modes by comparing a temporal behavior of the power of geomagnetic activity parameters since it is barely sufficient searching for common peaks with a similar periodicity in order to causally correlate geomagnetic activity parameters. As a result of the wavelet transform analysis we are able to obtain information on the temporal behavior of the power in the velocity of the solar wind, the number density of protons in the solar wind, the AE index, the Dst index, the interplanetary magnetic field, B and its three components of the GSM coordinate system, $B_X$, $B_Y$, $B_Z$. Secondly, we also attempt to search for any signatures of influence on the space environment near the Earth by inner planets orbiting around the Sun. Our main findings are as follows: (1) Parameters we have investigated show periodicities of ~ 27 days, ~ 13.5 days, ~ 9 days. (2) The peaks in the power spectrum of $B_Z$ appear to be split due to an unknown agent. (3) For some modes powers are not present all the time and intervals showing high powers do not always coincide. (4) Noticeable peaks do not emerge at those frequencies corresponding to the synodic and/or sidereal periods of Mercury and Venus, which leads us to conclude that the Earth's space environment is not subject to the shadow of the inner planets as suggested earlier.

Optimized Installation and Operations of Battery Energy Storage System and Electric Double Layer Capacitor Modules for Renewable Energy Based Intermittent Generation

  • Min, Sang Won;Kim, Seog Ju;Hur, Don
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.238-243
    • /
    • 2013
  • In this paper, a novel approach for optimized installation and operations of battery energy storage system (BESS) and electric double layer capacitor (EDLC) modules for the renewable energy based intermittent generation is presented for them to be connected with an electric power grid. In order to make use of not merely the high energy density of battery but also the high power density of EDLC modules, it is very useful to devise the hybrid system which combines BESS and EDLC modules. The proposed method adopts the linear programming to calculate the optimized capacity as well as the quadratic programming to transmit the optimal operational signals to BESS and EDLC modules. The efficiency of this methodology will be demonstrated in the experimental study with the real data of wind speed in Texas.

Correlation analysis of the wind of a cable-stayed bridge based on field monitoring

  • Li, Hui;Laima, Shujin;Li, Na;Ou, Jinping;Duan, Zhondong
    • Wind and Structures
    • /
    • 제13권6호
    • /
    • pp.529-556
    • /
    • 2010
  • This paper investigates the correlation of wind characteristics monitored on a cable-stayed bridge. Total five anemoscopes are implemented into the bridge. Two out of 5 anemoscopes in inflow and two out of 5 anemoscopes in wake-flow along the longitudinal direction of the bridge are installed. Four anemoscopes are respectively distributed at two cross-sections. Another anemoscope is installed at the top of the tower. The correlation of mean wind speed and direction, power spectral density, the turbulent intensity and integral length of wind in flow at two cross-sections are investigated. In addition, considering the non-stationary characteristics of wind, the spatial correlation in time-frequency is analyzed using wavelet transform and different phenomenon from those obtained through FFT is observed. The time-frequency analysis further indicates that intermittence, coherence structures and self-similar structures are distinctly observed from fluctuant wind. The flow characteristics around the bridge deck at two positions are also investigated using the field measurement. The results indicate that the mean wind speed decrease when the flow passing through the deck, but the turbulence intensity become much larger and the turbulence integral lengths become much smaller compared with those of inflow. The relationship of RMS (root mean square) of wake-flow and the mean wind speed of inflow is approximately linear. The special structures of wake-flow in time-frequency domain are also analyzed using wavelet transform, which aids to reveal the forming process of wake-flow.

다양한 변장비를 가진 고층건축물에 작용하는 풍력의 상관 분석 (Correlation Analysis of Aerodynamic Forces acting on Tall Buildings with Various Side Ratios)

  • 김원술;요시다 아키히토;타무라 유키오
    • 한국전산구조공학회논문집
    • /
    • 제28권2호
    • /
    • pp.153-160
    • /
    • 2015
  • 본 연구는 고층건축물의 기본설계 단계에서 평면형태를 결정할 때, 응용할 수 있도록 다양한 형상을 가진 고층건축물에 작용하는 풍력 및 풍응답에 대한 데이터베이스를 구축하는데 목적이 있다. 따라서 본 논문에서는 풍력데이터베이스의 초기단계로, 높이 200m이상의 고층건축물의 변장비(D/B=0.33, 0.50, 0.77, 0.83, 0.91, 1.0, 1.1, 1.2, 1.3, 2.0, 3.0) 변화에 따른 풍력의 특성을 조사하고 기존 문헌과의 비교 검토를 통해 실험결과를 검증하였다. 또한 풍하중조합의 관점에서 풍방향-풍직각방향, 풍방향-비틀림방향 및 풍직각방향-비틀림방향 간의 풍력의 상호상관에 대해서 검토하였다. 실험결과, 풍방향 및 풍직각방향에 대한 평균 및 변동 모멘트계수와 풍직각방향 및 비틀림방향 변동모멘트계수의 파워스펙트럼밀도의 결과는 기존 연구결과와 잘 부합되는 것으로 나타났다. 또한, 지표면조도의 변화에 따른 풍방향, 풍직각방향 및 비틀림방향에 대한 풍력의 특성은 큰 변화가 없는 것으로 나타났다. 시간영역과 주파수영역에서의 변동모멘트의 상호상관계수 분석결과, 풍직각방향-비틀림방향 변동모멘트계수의 상호상관계수가 높게 나타나는 경향을 보였다.

전산유동해석을 통한 산악 지역의 고해상도 풍력자원 특성에 관한 수치연구 (A Numerical Study on the Characteristics of High Resolution Wind Resource in Mountainous Areas Using Computational Fluid Dynamic Analysis)

  • 이순환
    • 한국지구과학회지
    • /
    • 제32권1호
    • /
    • pp.46-56
    • /
    • 2011
  • 전산유동 수치모형을 이용하여 다양한 대기안정도 상태하에서 부산광역시내 승학산과 구덕산의 초고해상도 풍력자원을 평가하였다. 연구에 사용된 수치모형은 중규모와 미규모 기상현상의 재현에 널리 사용되는 전산유동 수치모형인 A2C이다. 대기안정도가 강할 때, 위치에너지의 크기가 상대적으로 강해지기 때문에 산을 넘어가는 경향이 나타난다. 반면 대기안정도가 약해지면서 산악후면의 후류 발생이 증대되며, 난류에너지가 증가한다. 그리고 연평균 풍력밀도, 난류운동에너지, 연직 바람전단력 분석을 통하여 구덕산 정상의 남쪽 부근이 다른 구역보다 가용 풍력자원이 풍부함을 확인하였다.

계자 코일 구조에 따른 초전도 풍력 발전기의 모듈화 된 HTS계자 코일의 특성 분석 (Characteristic Analysis of Modularized HTS Field Coils for a Superconducting Wind Power Generator According to Field Coil Structure)

  • 투덴수런 오운자르갈;고병수;성해진;박민원;유인근
    • 한국산업정보학회논문지
    • /
    • 제24권2호
    • /
    • pp.15-23
    • /
    • 2019
  • 풍력발전 시스템용 고온 초전도 (HTS) 발전기는 높은 효율과 기존 발전기에 비해 작은 크기로 제작이 가능한 이점을 가지고 있다. 그러나 고온 초전도 발전기는 높은 전류 밀도와 자기장으로 인해 HTS 계자 코일에 작용하는 로렌츠 힘에 따른 문제가 발생할 수 있다. 본 논문에서는 계자 코일 구조에 따른 750 kW 급 초전도 풍력 발전기에 대한 모듈화 된 HTS 계자 코일의 특성 분석을 다룬다. 모듈화 된 HTS 필드 코일의 구조는 3D 유한 요소법을 사용하여 얻은 전자기 및 기계 분석 결과를 기반으로 설계하였고 모듈 코일의 전자기력도 분석하였다. 그 결과, HTS 코일의 수직 자기장과 최대 자기장은 각각 2.5 T와 3.9 T로 나타났다. 지지대의 최대 응력은 유리 섬유 강화 플라스틱 재료의 허용 응력보다 작았으며, 변위는 허용 범위 이내로 발생하였다. HTS 모듈 코일 구조의 설계 사양 및 결과는 대용량 초전도 풍력 발전기 개발에 효과적으로 활용될 수 있다.

공기 중의 미세먼지에 의한 태양전지의 오염에 관한 연구 (A Study on the Contamination of Photovoltaic Cells by Fine Dust in the Air)

  • 한진목;최수광;김세웅;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제29권3호
    • /
    • pp.292-298
    • /
    • 2018
  • The contamination of photovoltaic (PV) cells reduces the incidence of sunlight and reduces the power generation output of PV cells. The main factor influencing the contamination of PV cells installed outdoors is the fine dust in the air, but the influence of temperature, humidity, rain and wind can be considered. In this paper, experiments on the contamination of PV cells according to the fine dust density, the temperature and humidity of air were investigated. As results of this study, the contamination area of PV cells increases with contamination time and cumulative fine dust density in the air. The contamination of PV cells increases when the temperature is low and the humidity is high. Also, as the contamination of PV cells is affected to the wind, the deviation of contamination area is happened.

Uncertainty Analysis of Dynamic Thermal Rating of Overhead Transmission Line

  • Zhou, Xing;Wang, Yanling;Zhou, Xiaofeng;Tao, Weihua;Niu, Zhiqiang;Qu, Ailing
    • Journal of Information Processing Systems
    • /
    • 제15권2호
    • /
    • pp.331-343
    • /
    • 2019
  • Dynamic thermal rating of the overhead transmission lines is affected by many uncertain factors. The ambient temperature, wind speed and wind direction are the main sources of uncertainty. Measurement uncertainty is an important parameter to evaluate the reliability of measurement results. This paper presents the uncertainty analysis based on Monte Carlo. On the basis of establishing the mathematical model and setting the probability density function of the input parameter value, the probability density function of the output value is determined by probability distribution random sampling. Through the calculation and analysis of the transient thermal balance equation and the steady- state thermal balance equation, the steady-state current carrying capacity, the transient current carrying capacity, the standard uncertainty and the probability distribution of the minimum and maximum values of the conductor under 95% confidence interval are obtained. The simulation results indicate that Monte Carlo method can decrease the computational complexity, speed up the calculation, and increase the validity and reliability of the uncertainty evaluation.