Comparison of Frequencies in Order to Estimate of Tree Species Diversity in Caspian Forests of Iran

  • Mirzaei, Mehrdad;Bahnemiry, Atefeh Karimiyan;Abkenar, Kambiz Taheri
    • Journal of Forest and Environmental Science
    • /
    • v.35 no.1
    • /
    • pp.1-5
    • /
    • 2019
  • Species diversity is one of the most important indices that used to evaluate the sustainability of forest communities. In the present study, three variables including number of individuals (frequency of species), basal area and volume of tree species were compared to estimate tree species diversity in broadleaves forests of Iran. Based on systematic random design, 30 plots (circle plot, $1000m^2$) was selected. Type of species, number of species, DBH and height of trees were measured. Simpson (1-D), Hill ($N_2$), Shannon-Wiener (H'), Mc Arthur ($N_1$), Smith-Wilson ($E_{var}$) and Margalef ($R_1$) indices used to estimate tree species diversity. Species diversity was calculated in each plot. ANOVA test showed that there was a significant difference between of three variables used for estimation of species diversity. Number of trees variable has more precision than basal area and volume variables to estimate of species diversity. But Duncan test revealed that there were significant difference between of basal area and volume variables with number of trees. Therefore, basal area and volume variables were selected as more suitable variables in order to estimate of biodiversity indices in northern forests of Iran.

Development of design technique for automotive condenser (자동차용 에어컨 응축기의 설계기술 개발)

  • Cho, Y.D.;Han, C.S.;Yoo, S.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.10-17
    • /
    • 1999
  • The present work presents condensation heat transfer and pressure drop data for the flow of R-12 in flat extruded aluminum tubes with small hydraulic diameters. The tube outside dimensions are $18mm(width){\times}1.7mm(height)$. Three types of internal geometry with the same outside dimensions are tested : sample 1 (7 tube holes), sample 2 (13 tube holes) and sample 3 (7 tube holes, micro-fin). The overall heat transfer coefficient is obtained for air-to-refrigerant heat transfer, and the Wilson plot method is used to determine the heat transfer coefficient for refrigerant flow. The sample 2 and sample 3 show significantly higher performance than sample 1. The heat transfer rates for the sample 2 and sample 3 are 9% and 12% higher, respectively, than sample 1. The friction factors for the sample 2 and sample 3 are 11.9% and 2.4% higher, respectively, than sample 1.

  • PDF

A Study on Thermal Performance of Plate Cooler for Cooling Medium Speed Engine Lubricant Oil (선박용 중속엔진 오일냉각용 판형쿨러의 전열성능에 관한 연구)

  • Park, Jae-Hong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.83-90
    • /
    • 2020
  • Plate heat exchangers(PHE) have been commercialized since the 1920s. Since then, although the basic concept of PHEs has changed little, its design and construction have progressed significantly to accommodate higher temperatures, higher pressures, and large heat exchanging capacities. The development trend of PHEs is consistent with heat plate developments with better thermal efficiency, lower pressure drop, and good flow distribution. The purpose of this paper is to introduce the main development processes of a plate cooler for medium-speed engine lubricant oil cooling in vessels which is in line with the development trend of PHEs and to provide its thermal performance data that were found out during experimental tests. The plate cooler in this study cannot measure the wall temperatures directly due to its structural characteristics, so the heat transfer coefficients were calculated using the modified Wilson Plot method. The water-to-water tests were first conducted experimentally to figure out the characteristics of heat transfer coefficients and pressure drops on the water side and then the water-to-oil tests followed to obtain the heat transfer coefficients on the oil side. The test results showed that heat transfer coefficients and pressure drops on both water and oil side increased with flow rates, and it was also found that all the development targets of the plate cooler in this study were achieved successfully.

Performance Characteristic of Large Diameter Oval Finned-Tube Heat Exchanger for Dryer (건조기용 타원관 대구경 핀-관 열교환기의 성능특성)

  • Bae, Kyung-Jin;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.22-27
    • /
    • 2014
  • The objectives of this paper are to obtain an empirical equations regarding the correlations between heat transfer and pressure drop of oval fin-tube heat exchanger having large diameter using wilson plot method. It was difficult to find any recommendable heat transfer and friction factor correlation available for our large diameter experimental cases. Overall heat transfer coefficients are composed of the heat transfer coefficients both inside and outside tubes. The resulting empirical correlations for the Nui and f-factor are given as $Nu_i=0.0146Re^{0.809}Pr^{0.3}$ and $f=4.366Re^{-0.64}$, respectively. The empirical correlations of the Nui and f-factors were developed for the large diameter oval finned-tube heat exchanger as a function of the Reynolds number. As the EG(Ethylene glycol) and air flow rate increases, the heat transfer rate and pressure drop is increased largely.

Parameter Estimation of Perillyl Alcohol in RP-HPLC by Moment Analysis

  • Row Kyung Ho;Lee Chong Ho;Kang Ji Hoon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.1
    • /
    • pp.16-20
    • /
    • 2002
  • Parameter estimations were made for the reversed-phase adsorption of perillyl alcohol (POH), a potent anti-cancer agent, on octadecylsilyl-silica gel (ODS). The average particle diameter of ODS was about $15\;{\mu}m$, and the particles were packed in the column $(3.9\;\times\;300mm)$. The mobile phase used was a mixture of acetonitrile and water, in which the acetonitrile ranged between 50 and $70\;(v/v\;\%)$. The first absolute moment and the second central moment were determined from the chromatographic elution curves by moment analysis. Experiments were carried out using POH solutions within the linear adsorption range. The fluid-to-particle mass transfer coefficient was estimated using the Wilson-Geankoplis equation. The axial dispersion coefficient and the intra particle diffusivity were determined from the slope and intercept of a plot of H vs $1/u_0$, respectively. The contributions of each mass-transfer step were axial dispersion, fluid-to-particle mass transfer, and intraparticle diffusion.

Fouling Characteristics of Washable Shell and Coil Heat Exchanger (세척이 가능한 원통 코일형 열교환기의 파울링 특성에 관한 연구)

  • Hwang, Jun Hyeon;Na, Byung Chul;Oh, Sai Kee;Koo, Kyoung Min;Lee, Jae Keun;Ahn, Young Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.69-74
    • /
    • 2015
  • In this work, we studied the shell and helically coiled tube heat exchangers. Shell and coil heat exchangers with different rate of water flow and plate heat exchanger with same capacity were tested for condensing conditions. We proposed design guide using modified Wilson plot method. We compared fouling characteristics between shell and coil heat exchanger and plate heat exchanger, when they were washed and were not washed. The shell and coil heat exchanger showed 120% of higher saturated fouling resistance value and 4% of better heat transfer ratio than the plate heat exchanger.

Studies on Biomass for Young Abies koreana Wilson

  • Lee, Do-Hyung;Yoon, Jun-Hyuck;Woo, Kwan-Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.2
    • /
    • pp.138-144
    • /
    • 2007
  • This study was undertaken to compare the biomass of Abies koreana growing at two sites. A $10{\times}10m$ plot was established in each site of a natural stand in Mt. Jiri and a plantation in Gyeongsan nursery. Five trees of A. koreana were randomly selected in each site. The following traits were investigated from each tree : height, basal diameter, age, weight of stem, branches, and needles as above-ground traits and weight of total roots, horizontal roots, and vertical roots as below-ground traits. In Gyeongsan nursery, age of sample trees was negatively correlated with both height and weight of total stem, while height was highly correlated with weight of horizontal roots. There was high correlation between the basal diameter and weight of total stem, and between the basal diameter and weight of roots. In Mt. Jiri stand, most of the above-ground traits except age were significantly correlated with the below-ground traits. The linear regression equation between the cross section area of base (X) and the weight of total stem (Y) in Gyeongsan nursery was Y=12.66X-12.92, and correlation was significant ($R^2=0.89$). The linear regression equation between the cross section area of base(X) and the weight of total branches (Y) in Mt. Jiri stand was Y=25.51X+6.00, and correlation was highly significant ($R^2=1.0$).

An Experimental Study on Tube-Side Heat Transfer Coefficients and Friction Factors of the Enhanced Tubes Used in Regenerators of Absorption Chillers (흡수식 냉동기의 재생기에 사용되는 전열촉진관의 관 내측 열전달계수 및 마찰계수에 대한 실험적 연구)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.716-723
    • /
    • 2016
  • Enhanced tubes are used widely in the heat exchangers of absorption chillers. In regenerators, corrugated, ribbed or floral tubes are commonly used. In this study, the tube-side heat transfer coefficients and friction factors of enhanced tubes were obtained experimentally using the Wilson Plot method. The results showed that the heat transfer coefficients and the friction factors were the largest for the corrugated tube, followed by the ribbed tube. The heat transfer coefficients and friction factors of the floral tube matched those of the smooth tube within 4%, which suggests that the heat transfer and friction characteristics of the floral tube may be accounted for properly by the hydraulic diameter. The B(e+) and g(e+) were obtained from the experimental data of the corrugated and ribbed tube. The B(e+) and g(e+) of the corrugated tube matched those of the existing correlation within 20%. The present results may be used for an assessment of the heat transfer and friction characteristics of the enhanced tubes for regenerators.

Condensation Heat Transfer of R32 and R454B Inside a Microfin Tube as an Alternative Refrigerant to R410A (R410A 대체냉매 R32와 R454B의 미세핀 관내 응축 열전달)

  • KARAGEORGIS, ANDREAS;HINOPOULOS, GEORGE;KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.413-418
    • /
    • 2022
  • This paper presents two-phase condensation heat transfer and pressure drop characteristics of R32 and R454B as an alternative refrigerant to R410A in a 9.52 mm OD microfin tube. The test facility has a straight, horizontal test section with an active length of 2.0 m and is cooled by cold water circulated in a surrounding annular space. The heat transfer coefficients of the annular space were obtained using the modified Wilson plot method. Average condensation heat transfer coefficient and pressure drop data are presented at the condensation temperature of 35℃ for the range of mass flux 100-400 kg/m2s. The average condensation heat transfer coefficients of R32 refrigerant are 35-47% higher than R410A at the mass flux considered in the study, while R454B data are similar to R410A. The average pressure drop of R32 and R454B are much higher than R410A and they are 134-224% and 151-215% of R410A, respectively. R32 and R454B have relatively low GWP and high heat transfer characteristics, so they are suitable as alternatives for R410A.