• Title/Summary/Keyword: Wide-field

검색결과 2,373건 처리시간 0.035초

Wide Field-of-View Imaging Using a Combined Hyperbolic Mirror

  • Yi, Sooyeong;Ko, Youngjun
    • Current Optics and Photonics
    • /
    • 제1권4호
    • /
    • pp.336-343
    • /
    • 2017
  • A wide field-of-view (FOV) image contains more visual information than a conventional image. This study proposes a new type of hyperbolic mirror for wide FOV image acquisition. The proposed mirror consists of a hyperbolic cylindrical section and a bowl-shaped hyperbolic omnidirectional section. Using an imaging system with this mirror, it is possible to achieve a $213.8^{\circ}$ horizontal and a $126.94^{\circ}$ vertical maximum FOV. Parameters of each section of the mirror are designed to be continuous at the junction of the two parts, and the resultant image is seamless. The image-acquisition model is obtained using ray-tracing optics. To rectify the geometrical distortion of the original image due to the mirror, an image-restoration algorithm based on conformal projection is presented in this study. The performance of the proposed imaging system with the hyperbolic mirror and its image-restoration algorithm are verified by experiments.

Wide-angle optical design using high-resolution uncooled thermal detector

  • Lee, Jonghoon
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권11호
    • /
    • pp.31-37
    • /
    • 2017
  • In this paper, we propose efficient design and construction of an infrared wide angle optical system with low distortion utilizing a high resolution detector for automobile application. The operational convenience and the recognition ability have been improved significantly by applying the high resolution uncooled thermal detector with wide angle optical design. The active ahtermalization mechanism is implemented so that the adjustment of the optical component of the system is to be made automatically according to the temperature change by motorized control. The modulation transfer function (MTF) is about 50% at the Nyquist frequency close the diffraction limit. The distortion is less than 5% at the edge field. As a result, a high-resolution uncooled thermal optical system with wide field of view (FOV) is assembled, aligned and its performance is tested successfully.

Wide-Field Imaging Telescope-0(WIT0): A New Wide-Field 0.25 m Telescope at McDonald Observatory

  • Lee, Sang-Yun;Im, Myungshin;Pak, Soojong;Ji, Tae-Geun;Lee, Hye-In;Hwang, Seong Yong;Marshall, Jennifer;Prochaska, Travis;Gibson, Coyne A.
    • 천문학회보
    • /
    • 제42권1호
    • /
    • pp.34.2-34.2
    • /
    • 2017
  • A small wide-field imaging telescope is a powerful instrument to survey the Universe: wide-field image can monitor the variability of many sources at a time, e.g. young stellar objects and active galactic nuclei, and it can be an effective way to locate transient sources without precise positional information such as gravitational wave sources or some gamma-ray bursts. In February 2017, we installed a 0.25 m f/3.6 telescope on the McDonald 0.8 m telescope as a piggyback system. With a $4k{\times}4k$ CCD camera, the telescope has a $2.35{\times}2.35deg$ field-of-view. Currently, it is equipped with Johnson UBVRI filters and 3 narrow-band filters: $H{\alpha}$, OIII and SII. We will present the installation process, and the telescope performance such as detection limit and image quality based on the data from commissioning observations. We will also discuss possible scientific projects with this system.

  • PDF

저전력 광역통신망 기반 현장데이터 수집 전송 및 모니터링 시스템 개발 (Development of a System for Field-data Collection Transmission and Monitoring based on Low Power Wide Area Network)

  • 주영태;김종실;김응곤
    • 한국전자통신학회논문지
    • /
    • 제17권6호
    • /
    • pp.1105-1112
    • /
    • 2022
  • 신재생에너지 발전, 스마트팜 통합관제 등 현장데이터의 모니터링 시스템은 PC, 서버 기반에서 모바일 퍼스트 중심으로 발전하고 있으며, IoT 기술의 발전으로 다양한 무선통신 및 응용 서비스들이 출현하였다. 저전력 광역통신망은 저전력, 저용량, 저속 데이터 전송에 최적화된 서비스로 현장에서 수집된 데이터는 지정 저장 서버나 클라우드 기반 데이터 플랫폼으로 전송되며, 이를 통해 데이터 모니터링이 가능하다. 본 논문에서는 단일 디바이스로 현장 데이터를 수집하고 저전력 광역통신망을 이용하여 무선통신 사업자 클라우드 데이터 플랫폼으로 전송하는 IoT 중계기와 이를 활용한 현장 모니터링 앱을 설계 및 구현하였다. 이를 활용하면 보다 모니터링 시스템 구성이 간단하고, 구축 및 운영 비용이 저렴하며 효과적인 데이터 축적이 가능하다.

Photonic-Assisted Reactive-Near-Field Analysis of a 3 dB-Tapered Ka-Band Array Antenna

  • Lee, Dong-Joon;Kang, Jeong-Jin;Kang, No-Weon;Kim, Wan-Sik;Park, Wee-Sang;Rothwell, Edward J.;Whitaker, John F.
    • Journal of electromagnetic engineering and science
    • /
    • 제10권1호
    • /
    • pp.18-24
    • /
    • 2010
  • A Ka-band microstrip array antenna for wide-range detection of moving targets is analyzed through a photonicassisted reactive-near-field characterization technique. The antenna array employs a 3-dB-tapered feed network to suppress the sidelobe level while retaining a wide azimuth beamwidth for a wide detection range. The relative nearelectric field patterns of the array and its 3-dB-tapered feed lines have been measured using an electro-optic fieldmapping technique for minimally invasive millimeter-wave sensing. A number of typical limitations on the technique, involving bandwidth, low signal-modulation depth, and high laser-induced noise in high-frequency applications, have been overcome by suppressing the carrier portion of the optical interrogation beam.

병렬처리 그래픽 기술 기반의 Spectral Domain-Optical Coherence Tomography를 이용한 3차원 광 대역 망막 촬영 (High-Speed SD-OCT for Ultra Wide-field Human Retinal Three Dimensions Imaging using GPU)

  • 박기범;조남현;;김지현
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권3호
    • /
    • pp.135-140
    • /
    • 2013
  • We have developed an ultra wide-field of view Optical Coherence Tomography(OCT) which has capability to 2D and 3D views of cross-sectional structure of in vivo human retina. Conventional OCT has a limitation in visualizing the entire retina due to a reduced field of view. We designed an optical setup to significantly improve the lateral scanning range to be more than 20 mm. The entire human retinal structure in 2D and 3D was reported in this paper with the developed OCT system. Also, we empirically searched an optimized image size for real time visualization by analyzing variation of the frame rate with different lateral scan points. The size was concluded to be $1024{\times}2000{\times}300$ pixels which took 9 seconds for visualization.

시야 확장형 적외선카메라 설계 (Design of Infrared Camera for Extended Field of View)

  • 이용춘;송천호;김상운;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.699-701
    • /
    • 2017
  • 장거리 관측용 카메라의 일반적인 운용방법은 광각에서 표적에 대한 탐지를 하며, 망원으로 표적에 대한 인지/식별을 하게 된다. 탐지/인지거리 성능은 방산용 적외선카메라의 성능을 평가하는 중요한 항목이다. 탐지거리 성능이 증가하려면 카메라의 시야가 좁아져야 하고, 좁은 시야각으로 인하여 표적을 찾게 될 확률이 상대적으로 낮아지게 된다. 본 연구에서는 탐지거리 성능을 유지하면서 넓은 시야각을 제공하여 표적에 대한 탐색을 용이하게 할 수 있는 방안을 검토하였다. 그리고 M&S 및 최적화 설계를 통하여 시야 확장형 적외선카메라를 제작하고 시험한 결과를 정리하였다.

  • PDF

Design of an Optical System for a Space Target Detection Camera

  • Zhang, Liu;Zhang, Jiakun;Lei, Jingwen;Xu, Yutong;Lv, Xueying
    • Current Optics and Photonics
    • /
    • 제6권4호
    • /
    • pp.420-429
    • /
    • 2022
  • In this paper, the details and design process of an optical system for space target detection cameras are introduced. The whole system is divided into three structures. The first structure is a short-focus visible light system for rough detection in a large field of view. The field of view is 2°, the effective focal length is 1,125 mm, and the F-number is 3.83. The second structure is a telephoto visible light system for precise detection in a small field of view. The field of view is 1°, the effective focal length is 2,300 mm, and the F-number is 7.67. The third structure is an infrared light detection system. The field of view is 2°, the effective focal length is 390 mm, and the F-number is 1.3. The visible long-focus narrow field of view and visible short-focus wide field of view are switched through a turning mirror. Design results show that the modulation transfer functions of the three structures of the system are close to the diffraction limit. It can further be seen that the short-focus wide-field-of-view distortion is controlled within 0.1%, the long-focus narrow-field-of-view distortion within 0.5%, and the infrared subsystem distortion within 0.2%. The imaging effect is good and the purpose of the design is achieved.

High performance switched reluctance drives with wide field weakening range

  • Marquardt Rainer;Hiller Marc
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.779-784
    • /
    • 2001
  • For electrical vehicles, switched reluctance drives present a promising alternative-compared to asynchronous and synchronous (permanent magnet) concepts. For these applications, a very wide field weakening range is a key issue. Other requirements include high torque output from a small machine and low current ripple at the DC-side without the use of bulky filters - when powered from fuel cells or advanced Lithium-Ion-batteries. A new converter and control strategy according to these requirements is presented and compared to existing designs. The comparison is done for a drive system with a continuous power rating of 30 to 40 kW.

  • PDF