• Title/Summary/Keyword: Wide-beam

Search Result 546, Processing Time 0.023 seconds

Environmental Friendly Construction Process of Composite Beam and its Application (친환경 층고 절감형 합성보의 시공 Process 및 시공사례)

  • Hong, Won-Kee;Park, Seon-Chee;Lee, Kyoung-Hun;Kim, Jeom-Han;Lee, Ho-Chan;Hwang, Yun-Ha
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.107-112
    • /
    • 2007
  • Recently hybrid beam system is widely used because it has many structural advantages such as short construction period and low story height etc. Generally steel wide flange beam exposure type and embedded type hybrid beams are constructed. Even though exposure hybrid beam is easily constructed, the fire proofing protection process is necessary because steel wide flange beam cannot resist to fire itself. Story height reduction type hybrid beam, which is introduced hybrid beam in this paper, does not need fire proofing protection process because it is constructed as a fully embedded type hybrid beam. Developed construction process and actual construction cases of story height reduction type hybrid beam were introduced in this study.

Evaluation of Shear Strength for Wide Beam using GFRP Plate Shear Reinforcement (GFRP 판을 전단보강재로 사용한 넓은 보의 전단성능 평가)

  • Jo, Eunsun;Choi, Jin Woong;Kim, Min Sook;Kim, Heecheul;Lee, Young Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.3
    • /
    • pp.267-274
    • /
    • 2015
  • In this paper, an experimental evaluation of shear strength of wide beam is presented. By the experiment in paper, shear strength depending on parameter of shear reinforcement by GFRP plate on wide beam is investigated. Specimens are 7 of reinforced by GFRP plate with openings. The shear reinforcement is manufactured into plate shape with openings to ensure perfect integration with concrete. The test was performed on 7 specimens. The parameters are including number of shear reinforcement by GFRP plates and center-to-center spacing between vertical strip. We analysed the crack, failure mode, strain, shear strength of specimens. A calculation of the shear strength of reinforced wide beam with GFRP plate based on ACI 318-11. The result of the experiment shows that the GFRP plate is works successfully as shear reinforcement in the wide beam.

Study on Flexural Strength of Wide Composite Beam for Long Span and Saving Story height (장스팬 및 층고저감형 와이드 복합보의 휨성능에 관한 연구)

  • Choi, Yun-Cheul;Park, Keum-Sung;Lee, Sang-Sup;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.44-51
    • /
    • 2017
  • Recently, the parking in downtown area has caused severe problem due to the dramatic increase of possessing automobile in the country. A parking structure has been on the spotlight to solve the parking problem in downtown area. However, the overall height of parking structure is stipulated less than 8 m. Therefore, in this research, 'wide composite beam', which is possible for reducing story height and having long span, is developed and the flexural capacity of the wide composite beam is evaluated. Based on the result of the flexural test, the flexural strength of wide composite beam increased by 20% as the thickness of steel beam increased by 3 mm ($6mm{\rightarrow}9mm$) The shapes of rebar (whether it is triangle or rectangular shape) in the wide composite beam did not affect its flexural strength. The flexural strength of wide composite beam without rebar decreased by 10% compared to that of wide composite beam with rebar. In addition, the neutral axis moved upward as a load increased, but the neutral axis moved downward, when the load exceeded a certain level of load.

Structural Design Guide Line of Composite Beam (내화피복이 생략된 합성보의 구조설계지침 제정을 위한 고찰)

  • Hong, Won-Kee;Kim, Jin-Min;Lee, Kyoung-Hun;Park, Seon-Chee;Kim, Jeom-Han
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.93-98
    • /
    • 2008
  • As high rise buildings and large span spatial structures are constructed, new composite members and construction techniques are continuously developed. Wide flange steel beam can be easily constructed but the fire proofing protection is necessary and the cost is high. Nowadays environmental pollution of structures is becoming a big issue. The material of fire proofing protection is not allowed to use for structural members in several countries because it cab be a cause of environment pollution. Composite beam is a new hybrid beam system which is not needed a fire proofing protection process. Composite beam has better construction capacity than that of RC system and has more economic advantages than that of wide flange steel beam. In this paper, structural design guide lines of composite beam were provided to apply design and construction.

Hysteretic Behavior of Wide Beam-Column joint (외부 넓은 보-기둥 접합부의 이력거동에 관한 연구)

  • Seo Soo-Yeon;Kim Jong-Sun;Yoon Yong-Dae;Lee Woo-Jin;Kim Sang-Sik;Yoon Seung-Joe
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.623-626
    • /
    • 2004
  • The purpose of this paper is to study the effect of longitudinal reinforcement for anchoring in the wide beam column joint as wall as the contribution of depth of spandrel beam to hysteretic behavior of the wide beam column joint. From the test it was shown that the specimen with anchorage in the joint had higher strength than the specimen with normal hook anchorage. Specimen with debonded reinforcement at out of Id from column face failed showing moved plastic hinge and less strength than normal specimen. However, the dissipated energy was increased $11\%$.

  • PDF

10㎛-wide Pattern Engraving using Metal Specimens coated with a heterogeneous metal for Printed Electronics (이종 금속이 코팅된 금속소재를 이용한 인쇄전자소자용 선폭 10㎛급 패턴 가공)

  • Sohn, Hyonkee;Cao, Binh Xuan;Cho, Yong-Kwon;Shin, Dong-Sig;Choi, Jiyeon
    • Laser Solutions
    • /
    • v.17 no.4
    • /
    • pp.20-23
    • /
    • 2014
  • In printed electronics, printing rolls are used to transfer electronic ink onto a flexible substrate. Generally printing rolls are patterned in microscale by the indirect laser method. Since based on the wet etch process, the indirect method is neither environment-friendly nor suitable for making a printing roll with patterns narrower than $20{\mu}m$. In this paper, we have directly engraved micro-patterns into a Zn-coated metal specimens using a picosecond laser in order both to engrave $10{\mu}m$-wide patterns and to improve the pattern profile. Experiments showed that it is possible to engrave $10{\mu}m$-wide patterns with an a rectangular-shaped profile which is necessary for the dimensionally accurate printing.

  • PDF

FE Analysis of Exterior Wide Beam-Column Connections with Bonded Tendon Stress (부착된 프리스트레스 넓은 보-기둥 외부접합부의 유한요소해석)

  • Lee, Moon-Sung;Choi, Yun-Cheul;Lim, Jaei-Hyung;Moon, Jeong-Ho;Choi, Chang-Sick
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.4
    • /
    • pp.307-315
    • /
    • 2008
  • Post-tensioned precast concrete system (PPS) consists of U-shaped precast wide beams and concrete column. The continuity of beam-column joint is provided with the topping concrete on the PC shell beam and post-tensioning. Nonlinear analysis was conducted, using ANSYS, a finite-element analysis program, to obtain data for determining the characteristics of the structure and to allow various parametric analyses for post-tensioned wide beam-column connections. In this analysis, the Solid 65 element was used, in which concrete element had 8 nodes and each node had 3 degrees of freedomIn. Solid 65, the shear-transfer factor reflects a decrease of shear strength for the positions with cracks, as an impact factor to make the analysis value approximate the experiment value. In this study, the behavior of test specineus were most closely predicted to the experimental results, when the shear-transfer coefficient 0.85 was used for a closed crack, and 0.2 was used for an open crack.

Evaluation of Shear Capacity of Wide Beams Reinforced with GFRP and Steel Plates with Openings by Various Supporting Areas (지지부 조건에 따른 유공형 판으로 전단보강된 넓은 보의 전단성능 평가)

  • Kim, Heecheul;Ko, Myung Joon;Kim, Min Sook;Lee, Young Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.3
    • /
    • pp.269-275
    • /
    • 2016
  • In this paper, shear performance of concrete wide beams was evaluated through shear failure tests. The specimens were designed to have two continuous spans with a column at the center of the wide beam. Also the specimens were reinforced with plates with openings as shear reinforcements. For the test, total eight specimens, including five specimens were reinforced with steel plates and the other three specimens were reinforced with GFRP plates were manufactured. And the shear strengths obtained from the tests were compared with ones from the equation provided by ACI 318. Support width of wide beam, support section of wide beam and shear reinforcement material were considered as variables. The results showed that the support width was proportional to the increase of shear strength. Also, regardless of material type of shear reinforcement, the shear reinforcing effect was similar when the amount of shear reinforcement was the same.

Effect of fatigue crack propagation on natural frequencies of system in AISI 4140 Steel

  • Bilge, Habibullah;Doruk, Emre;Findik, Fehim;Pakdil, Murat
    • Steel and Composite Structures
    • /
    • v.32 no.3
    • /
    • pp.305-312
    • /
    • 2019
  • In this study, we investigated the effect of fatigue crack propagation of the beams which have a vital importance in engineering applications, on the natural frequency of the system. Beams which have a wide range of applications, are used as fundamental structural elements in engineering structures. Therefore, early detection of any damages in these structures is of vital importance for the prevention of possible destructive damages. One of the widely used methods of early detection of damages is the vibration analysis of the structure. Hence, it is of vital importance to detect and monitor any changes in the natural frequencies of the structure. From this standpoint, in this study we experimentally investigated the effect of fatigue crack propagation on beams produced from 4140 steel, of the natural frequency of the beam. A crack was opened on the $8{\times}16{\times}500mm$ beam using a 3 mm long and 0.25 mm wide wire erosion. The beam, then, underwent 3 point bending tests at 10 Hz with a dynamic fatigue device and its natural frequencies were measured in scheduled intervals and any changes taking place on the natural frequencies of the beam were measured. This data allowed us to identify and measure the crack occurring on the beam subjected to dynamic loading, during the propagation phase. This method produced experimental data. The experimental data showed that the natural frequency of the beam decreased with the propagation of the fatigue crack on the beam.

Performance Verification of Active Phased Array Broadband Antenna in Ka-Band (Ka대역 능동위상배열 광대역 안테나 성능 검증 )

  • Youngwan Kim;Jong-Kyun-Back;Hee-Duck Chae;Ji-Han Joo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.1
    • /
    • pp.23-30
    • /
    • 2024
  • This paper dedcribes the design. verification, and analysis techniques for an advanced phased array antenna. When applying an active phased array antenna to an aircraft or missile, miniaturization of the array antenna and wide-angle beam steering characteristics can be unavoidable antenna design considerations. In particular, the active reflection coefficient characteristics when electronically steering a wide-angle beam is a design parameter that must be minimized in terms of system survival and system performance. As a radiator suitable for broadband characteristics and wide-angle beam steering, this paper designed an array structure using SFN and minimized the active reflection coefficient according to beam steering of up to 40° based on the spherical coordivate system angle. The bandwidth of the radiator was confirmed to be 3GHz based on active reflection in the Ka-band. In addition, the performance of the actually manufactured 8by8 array antenna wsa analyzed by measuring the single pattern of the radiator through a near-field test, mathematically synthesizing it, and predicting the Tx/TRx beam used in the seeker system.