• Title/Summary/Keyword: Wide-angle

Search Result 1,039, Processing Time 0.035 seconds

Optimum Designs of 2 Segment LED Reflectors for Various Light Output Distributions on the Surface of an LED Chip (LED 칩 표면 광량 분포 변화에 따른 2단 반사컵의 최적 설계)

  • Yim, Hae-Dong;Lee, Dong-Jin;Kim, Yang Gyeom;Jeong, Jang Hee;Lee, Seung-Gol;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.6
    • /
    • pp.269-273
    • /
    • 2012
  • It is important to control the beam pattern of an LED by the design of a reflector. The optimum conditions of the structure parameters for the 2 segment LED reflector are analyzed and compared as they vary depending on the various intensity distributions of light output on the LED chip surface. It is also interesting that combining various types of reflectors is possible to give several efficient beam patterns, such as the maximum intensity profile or relatively wide controllability of beam angle.

A Study on Parallax Registration for User Location on the Transparent Display using the Kinect Sensor (키넥트 센서를 활용한 투명 디스플레이에서의 사용자 위치에 대한 시계 정합 연구)

  • Nam, Byeong-Wook;Lee, Kyung-Ho;Lee, Jung-Min;Wu, Yuepeng
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.599-606
    • /
    • 2015
  • International Hydrographic Organization(IHO) adopted standard S-100 as the international standard Geographic Information System(GIS) that can be generally used in the maritime sector. Accordingly, the next-generation system to support navigation information based on GIS standard technology has being developed. AR based navigation information system that supported navigation by overlapping navigation information on the CCTV image has currently being developed. In this study, we considered the application of a transparent display as a method to support efficiently this system. When a transparent display applied, the image distortion caused by using a wide-angle lens for parallax secure, and the disc s, and demonstrated the applicability of the technology by developing a prototype.

Investigation on High Transmittance Vertical Alignment (VA) display associated with Surface Polymer Stabilization (표면 고분자 안정화를 이용한 고 광효율 VA 디스플레이 연구)

  • Kim, Woo-Il;Kim, Sung-Min;Cho, In-Young;Kim, Dae-Hyun;Kwon, Dong-Won;Jeong, Yeon-Hak;Ryu, Jae-Jin;Kim, Kyeong-Hyeon;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.39-40
    • /
    • 2009
  • The patterned vertical alignment (PVA) display showed good electro-optic properties such as wide viewing angle, fast response time, high Contrast Ratio. However, the device has patterned electrode on both top and bottom electrodes which requires high accuracy of assembling of top and bottom substrates in order to exhibit a high performance. So, they have disadvantage about low yield. In order to resolve these problem, in this paper, we studied about top substrate pattern free vertical alignment device associated with surface polymer stabilization using the UV curable monomer. This method shows simple progress, low cost and good electro-optic properties such as high transmittance and fast response time.

  • PDF

A Study on the accuracy of Rangefinder between vessels by use of GPS (GPS를 이용한 선간거리계의 정확도에 관한 연구)

  • 김광홍
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.215-226
    • /
    • 1999
  • The experimented rangefinder consist of sets of V/A-Code GPS and sets of L1 C/A-code & carrier phase receivers connected by two spread spectrum radio modems in order to measure relative range and bearing between two ship antennas by real time, comparing and analyzing accuracy of both GPS receivers at the fix point on the land by means of executing zero baseline test by C/A code and by carrier phase as well as measuring distance range 5m, 10m, 15m between each other receivers. The results from the measurement of relative range and bearing are as follows as ;1. According to the results from zero baseline test, the average error by C/A-code receiver is less than 0.1m, which proves theories from published books but when each GPS receivers track different satellites, the range accuracy error becomes up to 100m by means of S/A. Because of this sudden wide range error, rangefinder is not appropriate at relative range measurement without additional modification of the algorism of the GPS receiver itself.2. According to relative range measurement by Carrier Phase and zero baseline test at static condition, the range error is less than 3.5cm in case that it passes more than 5 minutes after GPS sets can track simultaneously more than 6 satellites. Its main reason is understood that the phase center of antenna is bigger than geodetic antenna.3. When range measurement of two receivers from 5m, to 10m to 15m, the each range error is 0.340m, 0.190m, 0.011m and each standard variation is 0.0973m, 0.0884m, 0.0790m. The range error and standard variation are in inverse proportion to distance between two receivers. 4. L1 Carrier Phase GPS generally needs 5 minutes to fix and during this ambiguity search, the relative range and bearing angle is shown to be various.

  • PDF

종이의 유전 특성 향상을 위한 표면 사이즈제의 열적 안정성 및 유동현상 평가

  • 이학래;서만석
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2001.11a
    • /
    • pp.53-53
    • /
    • 2001
  • 종이의 전기적 성질 가운데 유전율은 전기장에 대한 종이의 물리화학적인 반응으로 일반적으로 종이의 밀도와 종이를 구성하는 성분의 쌍극자 모멘트에 비례하며 온도에 따라서도 변화한다. 일반적으로 온도가 상승하면 열에너지를 얻게된 쌍극자가 전기장에 배열됨으로써 유전율이 상승하지만 온도가 유리전이점 이상으로 높아질 경우에는 열적 교란에 의해서 분극능력이 감소하게 되어 유전완화 현상이 나타난다. 전기절연지로 사 용될 종이의 절연특성을 이해하기 위해서는 사용환경에 따른 유전적 특성 및 tan 0에 관한 연구가 필요하며 필름형성능력이 우수한 polyvinyl a1cohoHPV A)와 acrylonitrile을 이용하여 시아노에틸화한 PYA의 표면처리에 의해 종이의 유전적 특성이 향상되었음을 기존의 연구를 통하여 확인할 수 있었다. 본 연구에서는 전기절연지가 사용되는 환경조건에서 PYA를 기본물질로하는 유전필름 의 열적 안정성을 평가하였으며, 아울러 표면사이징 공정에서의 적용성 검토를 위하여 용액의 유동특성을 분석하였다. 유전특성 향상을 위해서는 표면 사이즈제의 유도체화 과정에서 쌍극자 모벤트의 밀도 증가를 통한 유전율 향상이 요청되며 이와 동시에 네트원 구조를 통하여 전기장에 대 한 물리적 특성이 유지되어야 한다. 본 연구에서는 W AXD( wide angle x-ray diffraction)를 이용하여 시아노에틸화 반응 과 고온에서의 열화에 의한 필름의 결정화도를 평가하였으며 온도 상승에 따른 흡열 피크의 변화를 통하여 온도 변화에 따른 PYA 분자구조의 변화와 유리전이온도의 추이 를 분석하였다. 또 열화과정에서 수반되는 필름의 중량감소율을 평가함으로써 열안정성 을 평가하였다. 그 결과 시아노에틸화한 PYA가 안정된 분자구조를 유지하고 있음을 확인할 수 있었다. 시아노에틸화한 PYA용액의 점탄성 평가를 위하여 storage modulus와 loss modulus 를 분석하였다. 일반적 유변특성 평가 결과 PYA용액은 shear-thinning, pseudoplastic 한 특성을 나타내어 표면사이즈 공정에서의 적용 가능성을 확인할 수 있었다.

  • PDF

Gasless Endoscopic Thyroidectomy Via Single Incision Axillary Approach (액와 단일절개 접근법을 이용한 내시경적 갑상선 절제술)

  • Kim, So Young;Ryu, Yoonjong;Jeong, Woo-Jin;Ahn, Soon-Hyun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.28 no.2
    • /
    • pp.114-117
    • /
    • 2012
  • Background and Objectives : To assure the surgical completeness of the gasless endoscopic thyroidectomy via single incision axillary approach using flexible videoscope which provide wide angle and working space, we compared single incision axillary approach and axillo-areolar approach by means of clinical, surgical outcomes. Materials and Methods : From March 2011 to July 2012, 24 patients who had underwent endoscopic thyroidectomy via transaxillary approach were enrolled. Of total, 17 patients underwent single incision axillary approach(group I) and the other 7 underwent axillo-areolar approach(group II). Results : Patient demographics, surgical indications were similar between the two groups. The operating time(group I 144.6min, group II 153.6 min ; p=.29), blood loss(group I : 55.4cc, group II : 35.7cc : p=.64), hospital stay(group I : 4.2days, group II : 4.4 days ; p=.65) were similar in the two groups. Overall, two patients in group I(2/17, 11.8%) experienced postoperative complications, including one hematoma and one seroma. Due to narrow working space, one patient was change to axillo-areolar approach during single incision axillary approach with $30^{\circ}$ rigid endoscope. Conclusion:Single incision axillary approach is safe and effective similar to other endoscopic thyroidectomy methods using flexible videoscope. Different with $30^{\circ}$ rigid endoscope, 10-mm flexible videoscope can put inside the axillary inicision site in different axis with endoscopic instruments. This difference in endoscopic axis help to prevent crash with endoscopic instrument.

Prediction on Throttling Performance of a Movable Sleeve Injector for Deep Throttling (딥 스로틀링 가변 슬리브 인젝터의 추력제어 성능예측)

  • Park, Sunjung;Nam, Jeongsoo;Lee, Keonwoong;Koo, Jaye;Hwang, Yongsok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.6
    • /
    • pp.487-495
    • /
    • 2018
  • Experimental analysis of the spray characteristics of the movable sleeve injector, which can simultaneously control the area of the annular gap and the pintle gap, has been studied and a method for controlling the uniform performance over a wide thrust range has been studied. It is confirmed that the design flow rate is not satisfied when the constant pressure difference is set regardless of the opening distance of the sleeve. In order to improve this, the differential pressure in the annular gap and the pintle gap was applied differently according to the opening distance. It was confirmed that the design flow rate was satisfied within the operating range and thrust control was linear from 25% to 100% in linear sleeve area.

Preparation of Poly(vinyl chloride)-graft-poly(styrene sulfonic acid) Composite Nanofiltration Membranes (폴리비닐클로라이드-그래프트-폴리스티렌 술폰산 복합 나노막 제조)

  • Kim, Jong-Hak;Park, Jung-Tae;Koh, Joo-Hwan;Roh, Dong-Kyu;Seo, Jin-Ah
    • Membrane Journal
    • /
    • v.18 no.2
    • /
    • pp.132-137
    • /
    • 2008
  • Nanofiltration membranes were prepared based on coating a sulfonated comb-like copolymer layer on top of a poly(vinylidene fluoride) (PVDF) support. The comb-like copolymer comprising poly(vinyl chloride) backbone and poly(styrene sulfonic acid) side chains, i.e. PVC-g-PSSA was synthesized by atom transfer radical polymerization (ATRP) using direct initiation of the secondary chlorines of PVC. The successful synthesis of graft copolymers were confirmed by nuclear magnetic resonance ($^1H$-NMR), FT-IR spectroscopy and wide angle X-ray scattering (WAXS). Composite nanofiltration membranes consisting PVC-g-PSSA as a top layer exhibited the increase of both rejections and solution flux with increasing PSSA concentration. This performance enhancement is presumably due to the increase of SO3H groups and membrane hydrophilicity. The rejections of composite membranes containing 71 wt% of PSSA were 88% for $Na_2SO_4$ and 33% for NaCl, and the solution flux were 26 and $34L/m^2h$, respectively, at 0.3 MPa pressure.

Simulated Optimum Substrate Thicknesses for the BC-BJ Si and GaAs Solar Cells

  • Choe, Kwang-Su
    • Korean Journal of Materials Research
    • /
    • v.22 no.9
    • /
    • pp.450-453
    • /
    • 2012
  • In crystalline solar cells, the substrate itself constitutes a large portion of the fabrication cost as it is derived from semiconductor ingots grown in costly high temperature processes. Thinner wafer substrates allow some cost saving as more wafers can be sliced from a given ingot, although technological limitations in slicing or sawing of wafers off an ingot, as well as the physical strength of the sliced wafers, put a lower limit on the substrate thickness. Complementary to these economical and techno-physical points of view, a device operation point of view of the substrate thickness would be useful. With this in mind, BC-BJ Si and GaAs solar cells are compared one to one by means of the Medici device simulation, with a particular emphasis on the substrate thickness. Under ideal conditions of 0.6 ${\mu}m$ photons entering the 10 ${\mu}m$-wide BC-BJ solar cells at the normal incident angle (${\theta}=90^{\circ}$), GaAs is about 2.3 times more efficient than Si in terms of peak cell power output: 42.3 $mW{\cdot}cm^{-2}$ vs. 18.2 $mW{\cdot}cm^{-2}$. This strong performance of GaAs, though only under ideal conditions, gives a strong indication that this material could stand competitively against Si, despite its known high material and process costs. Within the limitation of the minority carrier recombination lifetime value of $5{\times}10^{-5}$ sec used in the device simulation, the solar cell power is known to be only weakly dependent on the substrate thickness, particularly under about 100 ${\mu}m$, for both Si and GaAs. Though the optimum substrate thickness is about 100 ${\mu}m$ or less, the reduction in the power output is less than 10% from the peak values even when the substrate thickness is increased to 190 ${\mu}m$. Thus, for crystalline Si and GaAs with a relatively long recombination lifetime, extra efforts to be spent on thinning the substrate should be weighed against the expected actual gain in the solar cell output power.

A Study on Fabrication of Polyester Copolymers (Ⅵ) -Physical Properties of PET/PETG Copolymer Blend by the Drawing Conditions- (폴리에스테르 공중합체의 Fabrication 연구 (Ⅵ) -PET/PETG 공중합체 블렌드의 연신조건에 따른 물리적 특성-)

  • 현은재;이소화;김기영;제갈영순;장상희
    • Polymer(Korea)
    • /
    • v.26 no.3
    • /
    • pp.335-343
    • /
    • 2002
  • Blend resin (PET/PETG 70/30 blend) of poly (ethylene terephthalate) (PET) and poly (ethylene terephthalate glycol) (PETG) of weight percent 70/30 was prepared by a twin-screw extruder. Undrawn films of the blend and pure PETG were made by melt-press in hot press. Drawn films were made by capillary rheometer. Crystallinity, shrinkage, thermal, dynamic mechanical, and mechanical properties of these blends and PETG drawn films were investigated by wide angle X-ray diffractometer, dry oven, DSC thermal analyzer, and tensile tester. The crystallinity and density of these films increased with increasing draw ratio and draw rate but decreased with increasing draw temperature. The crystallinity and density of the blend films were higher than those of PETG films. The tensile strength and tensile modulus of these drawn alms increased with increasing draw ratio and draw rate but decreased with increasing draw temperature. The tensile strength and tensile modulus of blend films were higher than those of PETG films. Shrinkage of PETG md blend films decreased with draw ratio and draw rate. Shrinkage of undrawn blend film was 600% higher than that of pure PET film.