• Title/Summary/Keyword: Wide area detector

Search Result 37, Processing Time 0.026 seconds

The Effects of a Vasodilator on Transluminal Attenuation Gradient at Coronary Computed Tomography Angiography

  • Moon Sung Kim;Eun-Ju Kang;Hyun Jin Kim;Moo Hyun Kim;Ki-Nam Lee
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1285-1293
    • /
    • 2020
  • Objective: To evaluate the effects of vasodilators on contrast enhancement and transluminal attenuation gradient (TAG) of coronary arteries at coronary computed tomography angiography (CCTA). Materials and Methods: We retrospectively reviewed CCTA scans of patients who underwent double-acquisition CCTA; CCTA without a vasodilator, and CCTA during a intravenous (IV) infusion of nitrate. Among them, we enrolled 19 patients who had no significant atherosclerotic lesions or coronary spasms. In the control group, 28 patients were enrolled who showed normal coronary arteries on CCTA, which was acquired by a conventional method (sublingual vasodilator). We measured the TAG and Hounsfield units for each of the three major epicardial coronary arteries (reported as 'ProxHU') and then compared the results between the nitrate administration methods (CT without vasodilator [CTpre], CT with IV vasodilator [CTiv], and CT with sublingual vasodilator [CTsub]). Results: The mean TAG showed a significant difference between the coronary arteries (right coronary artery [RCA] > left anterior descending artery [LAD] > left circumflex artery [LCX], p < 0.05), while there was no difference in ProxHU of each coronary artery in all three types of nitrate administration methods (p > 0.05). The TAG of CTpre group showed steeper slope than those of vasodilator groups (CTiv and CTsub) on LAD and LCX ([LAD: CTpre = -22.1 ± 6.66, CTiv = -16.76 ± 5.78, and CTsub = -16.47 ± 5.78, p = 0.005], [LCX: CTpre = -31.26 ± 17.43, CTiv = -23.74 ± 14.06, and CTsub = -20.94 ± 12.15, p = 0.051]), while that of RCA showed no significant differences (p = 0.600). When comparing proxHU, CTiv showed higher proxHU than that of CTpre or CTsub, especially on LCX (CTpre = 426.7 ± 68.3, CTiv = 467.9 ± 84.9, and CTsub = 404.9 ± 63.3, p = 0.013). ProxHU showed a negative correlation with TAG on all three of methods (r = -0.280, p < 0.001). Conclusion: TAG in CCTA was significantly affected by vasodilator administration. Both TAG and ProxHU of coronary arteries tend to increase with vasodilator administration on CCTA.

Characterization of CdS Thin Films for Compound Photovoltaic Applications by Atmospheres of Rapid Thermal Process (급속열처리 분위기에 따른 화합물 태양전지용 CdS 박막의 특성변화)

  • Park, Seung-Beum;Kwon, Soon-Il;Lee, Seok-Jin;Jung, Tae-Hwan;Yang, Kea-Joon;Lim, Dong-Gun;Park, Jae-Hwan;Song, Woo-Chang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.105-106
    • /
    • 2008
  • Structural, optical and electrical properties of CdS films deposited by chemical bath deposition (CBD), which are a very attractive method for low-cost and large-area solar cells, are presented. Cadmium sulfide (CdS) is II-VI semiconductor with a wide band gap of approximately 2.42 eV. CdS films have a great application potential such as solar cell, optical detector and optoelectronics device. In this paper, effects of Rapid Thermal Process (RTP) on the properties of CdS films were investigated. The CdS films were prepared on a glass by chemical bath deposition (CBD) and subsequently annealed at standard temperature $(400^{\circ}C)$ and treatment time (10 min) in various atmospheres (air, vacuum and $N_2$). The CdS films treated RTP in $N_2$ for to min were showed larger grain size and higher carrier density than the other samples.

  • PDF

Residual Concentrations of Fluoroquinolones in Farmed Fish in the Southern Coast of Korea (남해안 양식어류의 fluoroquinolone계 항균제 잔류량)

  • Kim Poong-Ho;Lee Hee-Jung;Jo Mi-Ra;Lee Tae-Seek;Ha Jin-Hwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.39 no.2
    • /
    • pp.66-71
    • /
    • 2006
  • Fluoroquinoles have a wide range of antimicrobial properties and are effective in the treatment of bacterial diseases in fish. The use of fluoroquinoles continues to grow steadily. Fluoroquinolone antibiotics are probably the most important class used among synthetic antibiotics in human and veterinary medicines because of their broad activity spectrum and good oral absorption. This study was conducted to estimate the residue of antibiotics in four species of farmed fishes, including olive flounder (Paralichthys olivaceus), black rock fish (Sebastes schlegeli), red sea bream (Pagrus major), and sea bass (Lateolabrax japonicus), collected from fish farms located in the southern coastal area of Korea. The residues of fluoroquinolones were determined using high performance liquid chromatography (HPLC) with a fluorescence detector. Residuals of five fluoroquinolones in muscle tissue of farmed fish were analyzed. We found that enrofloxacin was the most common agent in fish muscle, and that ciprofloxacin was the next most common. The range of detected concentrations of fluoroquinolones in olive flounder muscle was 0-0.859 mg/kg in 32.6% of all samples. Enrofloxacin was commonly detected in sea bass muscle at a range of 0-0.143 mg/kg in 38.9% of all samples. Fluoroquinolones were detected in 6.9% of black rock fish muscle and in 16.6% of sea bream, although the detected concentration was below 0.01 mg/kg. The maximum detection value of enrofloxacin and ofloxacin in olive flounder at the time of shipping was 0.102 mg/kg and 0.09 mg/kg, respectively; no other antimicrobials were detected. We detected no antimicrobial substances in red sea bream.

A Study on the Precise Lineament Recovery of Alluvial Deposits Using Satellite Imagery and GIS (충적층의 정밀 선구조 추출을 위한 위성영상과 GIS 기법의 활용에 관한 연구)

  • 이수진;석동우;황종선;이동천;김정우
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2003.04a
    • /
    • pp.363-368
    • /
    • 2003
  • We have successfully developed a more effective algorithm to extract the lineament in the area covered by wide alluvial deposits characterized by a relatively narrow range of brightness in the Landsat TM image, while the currently used algorithm is limited to the mountainous areas. In the new algorithm, flat areas mainly consisting of alluvial deposits were selected using the Local Enhancement from the Digital Elevation Model (DEM). The aspect values were obtained by 3${\times}$3 moving windowing of Zevenbergen & Thorno's Method, and then the slopes of the study area were determined using the aspect values. After the lineament factors in the alluvial deposits were revealed by comparing the threshold values, the first rank lineament under the alluvial deposits were extracted using the Hough transform In order to extract the final lineament, the lowest points under the alluvial deposits in a given topographic section perpendicular to the first rank lineament were determined through the spline interpolation, and then the final lineament were chosen through Hough transform using the lowest points. The algorithm developed in this study enables us to observe a clearer lineament in the areas covered by much larger alluvial deposits compared with the results extracted using the conventional existing algorithm. There exists, however, some differences between the first rank lineament, obtained using the aspect and the slope, and the final lineament. This study shows that the new algorithm more effectively extracts the lineament in the area covered with wide alluvlal deposits than in the areas of converging slope, areas with narrow alluvial deposits or valleys.

  • PDF

Analysis of Surface Plasmon Resonance on Periodic Metal Hole Array by Diffraction Orders

  • Hwang, Jeong-U;Yun, Su-Jin;Gang, Sang-U;No, Sam-Gyu;Lee, Sang-Jun;Urbas, Augustine;Ku, Zahyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.176-177
    • /
    • 2013
  • Surface plasmon polaritons (SPPs) have attracted the attention of scientists and engineers involved in a wide area of research, microscopy, diagnostics and sensing. SPPs are waves that propagate along the surface of a conductor, usually metals. These are essentially light waves that are trapped on the surface because of their interaction with the free electrons of conductor. In this interaction, the free electrons respond collectively by oscillating in resonance with the light wave. The resonant interaction between the surface charge oscillation and the electromagnetic field of the light constitutes the SPPs and gives rise to its unique properties. In this papers, we studied theoretical and experimental extraordinary transmittance (T) and reflectance (R) of 2 dimensional metal hole array (2D-MHA) on GaAs in consideration of the diffraction orders. The 2d-MHAs was fabricated using ultra-violet photolithography, electron-beam evaporation and standard lift-off process with pitches ranging from 1.8 to $3.2{\mu}m$ and diameter of half of pitch, and was deposited 5-nm thick layer of titanium (Ti) as an adhesion layer and 50-nm thick layer of gold (Au) on the semiinsulating GaAs substrate. We employed both the commercial software (CST Microwave Studio: Computer Simulation Technology GmbH, Darmstadt, Germany) based on a finite integration technique (FIT) and a rigorous coupled wave analysis (RCWA) to calculate transmittance and reflectance. The transmittance was measured at a normal incident, and the reflectance was measured at variable incident angle of range between $30^{\circ}{\sim}80^{\circ}$ with a Nicolet Fourier transmission infrared (FTIR) spectrometer with a KBr beam splitter and a MCT detector. For MHAs of pitch (P), the peaks ${\lambda}$ max in the normal incidence transmittance spectra can be indentified approximately from SP dispersion relation, that is frequency-dependent SP wave vector (ksp). Shown in Fig. 1 is the transmission of P=2.2 um sample at normal incidence. We attribute the observation to be a result of FTIR system may be able to collect the transmitted light with higher diffraction order than 0th order. This is confirmed by calculations: for the MHAs, diffraction efficiency in (0, 0) diffracted orders is lower than in the (${\pm}x$, ${\pm}y$) diffracted orders. To further investigate the result, we calculated the angular dependent transmission of P=2.2 um sample (Fig. 2). The incident angle varies from 30o to 70o with a 10o increment. We also found the splitting character on reflectance measurement. The splitting effect is considered a results of SPPs assisted diffraction process by oblique incidence.

  • PDF

Development of Agricultural Products Screening System through X-ray Density Analysis

  • Eunhyeok Baek;Young-Tae Kwak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.4
    • /
    • pp.105-112
    • /
    • 2023
  • In this paper, we propose a new method for displaying colored defects by measuring the relative density with the wide-area and local densities of X-ray. The relative density of one pixel represents a relative difference from the surrounding pixels, and we also suggest a colorization of X-ray images representing these pixels as normal and defective. The traditional method mainly inspects materials such as plastics and metals, which have large differences in transmittance to the object. Our proposed method can be used to detect defects such as sprouts or holes in images obtained by an inspection machine that detects X-rays. In the experiment, the products that could not be seen with the naked eye were colored with pests or sprouts in a specific color so that they could be used in the agricultural product selection system. Products that are uniformly filled with a single ingredient inside, such as potatoes, carrots, and apples, can be detected effectively. However, it does not work well with bumpy products, such as peppers and paprika. The advantage of this method is that, unlike machine learning, it doesn't require large amounts of data. The proposed method could be applied to a screening system using X-rays and used not only in agricultural product screening systems but also in manufacturing processes such as processed food and parts manufacturing, so that it can be actively used to select defective products.

Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring (파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측)

  • Kim, Young-Su;Park, Jin Hyung;Cho, Hwa Youn;Kim, Jae Hyeon;Kwon, Heungrok;Seo, Hee;Park, Se-Hwan;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Compton cameras overcome several limitations of conventional mechanical collimation based gamma imaging devices, such as pin-hole imaging devices, due to its electronic collimation based on coincidence logic. Especially large-scale Compton camera has wide field of view and high imaging sensitivity. Those merits suggest that a large-scale Compton camera might be applicable to monitoring nuclear materials in large facilities without necessity of portability. To that end, our research group have made an effort to design a large-scale Compton camera for safeguard application. Energy resolution or position resolution of large-area detectors vary with configuration style of the detectors. Those performances directly affect the image quality of the large-scale Compton camera. In the present study, a series of Geant4 Monte Carlo simulations were performed in order to examine the effect of those detector parameters. Performance of the designed large-scale Compton camera was also estimated for various monitoring condition with realistic modeling. The conclusion of the present study indicates that the energy resolution of the component detector is the limiting factor of imaging resolution rather than the position resolution. Also, the designed large-scale Compton camera provides the 16.3 cm image resolution in full width at half maximum (angular resolution: $9.26^{\circ}$) for the depleted uranium source considered in this study located at the 1 m from the system when the component detectors have 10% energy resolution and 7 mm position resolution.