• Title/Summary/Keyword: Wick effect

Search Result 27, Processing Time 0.02 seconds

The Effect of Working Fluid Charge on the Performance of a Heat Pipe for Medium-temperature Solar Thermal Storage System (중온 태양열 축열조용 히트파이프의 작동액체 충전량이 열성능에 미치는 영향)

  • Min, Kyu-Park;Joon, Hong-Boo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.68-73
    • /
    • 2011
  • An experimental study was conducted to investigate the thermal performance of a medium-temperature heat pipe against the charge amount of working fluid. The container and the wick of the heat pipe were made of stainless steel and the working fluid was Dowtherm-A for medium-temperature applications around $250^{\circ}C$. The diameter and length of the heat pipe were 25.4 mm and 1 m, respectively. The maximum thermal load was 1 kW and the working fluid charge ratio varied from 372% to 420%. The results showed that the thermal resistance ranged from 0.12 to $250^{\circ}C/W$ and the effective thermal conductance ranged from 7,703 to $8,898 W/m{\cdot}K$. Dry-out occurred for the heat pipe with 372% fill-charge at the heat load of 950 W, while the other heat pipes with higher charge amount did not encounter dry-out up to 1060 W.

  • PDF

Effect of Opuntia Ficus-indicts variety Saboten Makino and Satsuma Mandarin Dyeing on Physical Characteristics and Colors of Protein Fabrics (선인전 및 감귤염색에 의한 단백질 직물의 물성 및 색상에 관한 연구)

  • 박순자;박덕자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.3_4
    • /
    • pp.473-484
    • /
    • 2002
  • The physical characteristics of silk and wool fabrics dyed with OFS-FR and SM-FR were examined and color difference and colorfastness of these fabrics were analyzed. The results are as follows; 1. The thickness, density and weight of both dyed fabrics were increased than those of undyed fabrics independently of dyeing materials and mordants. 2. Air permeability of all the silk samples increased than that of undyed silk, on the other hand, air permeability of most of wool samples decreased than that of undyed wool. 3. Thermal insulation values of silk samples were not consistent with dyeing conditions, but those of wool samples increased than those of undyed fabrics regardless of dyeing materials and mordants. 4. Color difference was clear between OFS-FR and SM-FR dyed fabrics. The colors dyed with OFS-FR-Al and OFS-FR-chitos an showed violet, those dyed with SM-FR displayed yellowish, in addition to in case of wool, dyed with OFS-FR-Cu the color was greenish yellow, in case of silk dyed with SM-FR-Cu that was yellowish red. 5. Sense of silk fabrics by sensory-test was soft and smooth. Feeling of colors in silk fabrics was wick, warm and slightly brilliant. In case wool, sense of dyed fabrics was slightly soft and slightly rough. Feeling of colors in wool fabrics was warm but not elegant. Therefore the result of sensory-test in silk might be better than that of in wool. 6. Colorfastness to dry cleaning and perspirations was good, but that to washing and sunlight was not fine.

Perception of upper lip augmentation utilizing simulated photography

  • Linkov, Gary;Wick, Elizabeth;Kallogjeri, Dorina;Chen, Collin L.;Branham, Gregory H.
    • Archives of Plastic Surgery
    • /
    • v.46 no.3
    • /
    • pp.248-254
    • /
    • 2019
  • Background No head to head comparison is available between surgical lip lifting and upper lip filler injections to decide which technique yields the best results in patients. Despite the growing popularity of upper lip augmentation, its effect on societal perceptions of attractiveness, successfulness and overall health in woman is unknown. Methods Blinded casual observers viewed three versions of independent images of 15 unique patient lower faces for a total of 45 images. Observers rated the attractiveness, perceived success, and perceived overall health for each patient image. Facial perception questions were answered on a visual analog scale from 0 to 100, where higher scores corresponded to more positive responses. Results Two hundred and seventeen random observers with an average age of 47 years (standard deviation, 15.9) rated the images. The majority of observers were females (n=183, 84%) of white race (n=174, 80%) and had at least some college education (n=202, 93%). The marginal mean score for perceived attractiveness from the natural condition was 1.5 points (95% confidence interval [CI], 0.9-2.18) higher than perceived attractiveness from the simulated upper lip filler injection condition, and 2.6 points higher (95% CI, 1.95-3.24) than the simulated upper lip lift condition. There was a moderate to strong correlation between the scores of the same observer. Conclusions Simulated upper lip augmentation is amenable to social perception analysis. Scores of the same observer for attractiveness, successfulness, and overall health are strongly correlated. Overall, the natural condition had the highest scores in all categories, followed by simulated upper lip filler, and lastly simulated upper lip lift.

BOTANI: High-fidelity multiphysics model for boron chemistry in CRUD deposits

  • Seo, Seungjin;Park, Byunggi;Kim, Sung Joong;Shin, Ho Cheol;Lee, Seo Jeong;Lee, Minho;Choi, Sungyeol
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1676-1685
    • /
    • 2021
  • We develop a new high-fidelity multiphysics model to simulate boron chemistry in the porous Chalk River Unidentified Deposit (CRUD) deposits. Heat transfer, capillary flow, solute transport, and chemical reactions are fully coupled. The evaporation of coolant in the deposits is included in governing equations modified by the volume-averaged assumption of wick boiling. The axial offset anomaly (AOA) of the Seabrook nuclear power plant is simulated. The new model reasonably predicts the distributions of temperature, pressure, velocity, volumetric boiling heat density, and chemical concentrations. In the thicker CRUD regions, 60% of the total heat is removed by evaporative heat transfer, causing boron species accumulation. The new model successfully shows the quantitative effect of coolant evaporation on the local distributions of boron. The total amount of boron in the CRUD layer increases by a factor of 1.21 when an evaporation-driven increase of soluble and precipitated boron concentrations is reflected. In addition, the concentrations of B(OH)3 and LiBO2 are estimated according to various conditions such as different CRUD thickness and porosity. At the end of the cycle in the AOA case, the total mass of boron incorporated in CRUD deposits of a reference single fuel rod is estimated to be about 0.5 mg.

The effect of Temperature Reduction of Green Roof using Rainwater Storage Tank (빗물 저류 시스템을 활용한 옥상 녹화의 온도 저감 효과)

  • Yun, Seok-Hwan;Kim, Eun-Sub;Piao, Zheng-Gang;Jeon, Yoon-Ho;Kang, Hye-Won;Kim, Sang-Hyuck;Kim, Ji-Yeon;Kang, Han-Min;Ham, Eun-Kyung;Lee, Dong-Kun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.6
    • /
    • pp.109-119
    • /
    • 2021
  • Thermal environment of city is getting worse due to severe urban heat island caused by climate change and urbanization. Green roof improves the urban thermal environment and save the cooling energy in buildings. This study presented a green roof combined with a storage system that stores rain-water and supplies water through a wick and evaluated the temperature reduction effect as surface temperature and amount of evapotranspiration. For about a week, the surface temperature using a infrared thermal imager and the evapotranspiration by recording change of module weight were measured at intervals of 30 minutes from sunrise to sunset. The results show that the mean surface temperature of the green roof was 15.4 degrees lower than that of the non-green roof from 12:00 P.M. to 14:00 P.M. There was no significant difference between mean surface temperature of green roof with and without storage system immediately after rain, but more than a week after rain, there was a difference with average of 2.49 degrees and maximum of 4.72 degrees. The difference in daily amount of evapotranspiration was measured to be 1.66 times on average. As drought stress increased over time, the difference in daily amount of evapotranspiration and surface temperature between with/without storage system increased simultaneously. The results of the study show a more excellent cooling effect of green roof combined with the rainwater storage system.

Combustion of a Female Body Due to an External Ignition Source (외부 점화원에 의한 여성 신체의 연소)

  • Cho, Young Jin;Ji, Hong Keun;Kim, Sun Jae;Lim, Kyu Young;Lee, Dong Kyu;Choi, Gyeong Won;Park, Jong Taek;Moon, Byung Sun;Goh, Jae Mo;Park, Nam Kyu
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.94-96
    • /
    • 2020
  • In November 2013, a case of sustained combustion of a female body was encountered in a Korean farming village. The body was almost completely incinerated from the neck to the knees, and other parts of the body, such as the head, arms, lower legs, and feet, were slightly damaged. The most likely external ignition source was the flame from a matchstick. The elderly woman was found incinerated on the floor of the living room, while other objects in the house were largely undamaged except for having a brown oily or greasy coating. Flammable substances were not detected from the woman's intact pieces of clothing and socks, and her muscular tissues did not contain toxic chemicals. The concentration of carboxyhemoglobin in her peripheral blood was 11% and that of ethyl alcohol in her aqueous humor was below 0.010%. An autopsy failed to determine the exact cause of death because of excessive charring.

Similitude Law on Material Non-linearity for Seismic Performance Evaluation of RC Columns (RC기둥의 내진성능평가를 위한 재료비선형 상사법칙)

  • Lee, Do-Keun;Cho, Jae-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.409-417
    • /
    • 2010
  • This paper discusses a series of experiments including material improvement in order to ensure quality of grouting for the post-tensioned structure. In prestressed concrete, grouting refers to the construction procedure of filling empty space of duct enclosing with strands using cementitious material, To date, adequate quality control of the grouting has not been established in Korea because the relationship between the grouting and durability of post-tensioned structure is not well-recognized. The Korean standard does not consider the important material characteristic, wick effect, which is caused by strands in the ducts and current standard testing method unlikely quantify reasonable material segregation. As a result, the grout material, which meets the current material standards, may exhibit excessive bleeding water or shrinkage during construction. In this study, international codes and standards related to grouting were surveyed. The ratio of constituents and novel admixtures were suggested to meet equivalently with these standards. Performance of this enhanced grout was compared to common domestic grout using the international standard testing method. A series of mock-up specimens considering geometry of PC beam was constructed and grout flow pattern was observed as the grout was injected. It was observed that the grouting performance was highly influenced by material properties and filling characteristic can be varied depending on geometry of ducts.