Effect of Palm Facing Forward Posture on SpinoPelvic Parameters on the Whole Spine Lateral Radiography (척추 전장 측면 방사선검사 시 손바닥 정면 자세가 척추골반지표에 미치는 영향)

  • Joo, Young-Cheol;Kim, Han-Yong;Kim, Dong-Hwan
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.391-396
    • /
    • 2022
  • The purpose of this study was to investigate the effect of cross arms and palms facing forward on spinopelvic parameters during the whole spine lateral radiography. In addition, we would like to present the usefulness of a posture with the palm facing forward during whole spine lateral radiography of the spine using EOS. The subjects of this study were images of a total of 50 patients (18 males, 32 females) who whole spine lateral radiography using the conventional method and the EOS method from October 2020 to March 2021. The posture used in this study was set as 'CAP' for cross arms and 'PUSH' for posture with palms facing forward. In this study, among the spinal stability factors, thoracic kyphosis (thoracic vertebrae 4 to 12), lumbar lordosis (lumbar vertebrae 1 to sacrum 1), sagittal vertical axis, sacral slope, and shoulder flexion angle were compared on average. The mean thoracic kyphosis was 34.52±12.46° for CAP and 28.46±10.81° for PUSH (p<0.01). The lumbar lordosis of CAP was 42.45±17.45°and that of PUSH was 40.56±16.14°(p>0.57). The sagittal vertical axis was 26.59±34.34 mm in CAP and 21.21±35.41 mm in PUSH (p>0.44). In CAP, the sacral slope was 30.96±10.29°, and in PUSH, it was 31.01±10.19° (p>0.98). shoulder flexion angle was 38.31±8.24° for CAP and 26,08±6.71° for PUSH(p<0.01). As a result of this study, the PUSH posture is considered to be a posture that can minimize the shoulder flexion angle and can perform a stable examination while minimizing changes in spino-pelvic parameter.

Effect of Stitching Range on Radiation Dose to Eyeball, Thyroid, Breast, Pelvis in Whole Spine Radiography with Standing Position (선 자세 척추 전장 방사선검사 시 스티칭 범위가 장기(수정체, 갑상샘, 유방, 골반부)의 선량에 미치는 영향)

  • Min-Ji, Hong;Han-Yong, Kim;Dong-Hwan, Kim;Young-Cheol, Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.47-52
    • /
    • 2023
  • In whole spine radiography using the stitching technique, overlapping parts occur in the process of synthesizing the three segmented images, so some anatomical structures may be repeatedly exposed, and it has been thought that the dose increases as the scan range increases. However, in the whole spine radiography using the stitching technique in this study, under the condition that the stitching range is taken in the same three splits, the overlapping area decreases as the stitching range increases, so in the case of breasts included in the overlapping range, the dose value decreased by almost half as the stitching range increased from 90 cm to 105 cm. During spinal full-length radiological examination using the stitching method, an appropriately long stitching range could be set to reduce the exposure dose of the breast.

Measurement of Breast Skin Dose According to Shield Thickness During Whole Spine Scanography Using Digital Radiography System (Digital Radiography 시스템을 사용하여 전 척추검사 시 차폐체 두께에 따른 유방피부선량 측정)

  • Nam, Soon-Kwon;Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.25-30
    • /
    • 2019
  • Whole Spine Scanography (WSS) using the Digital Radiography (DR) system is an examination that requires whole body X-ray exposure, which involves more exposure to radiation for patients than other general radiographies. This can affect the occurrence of breast cancer. This research measured radiation dose when breasts were shield and not shield using the Auto Exposure Control (AEC) mode. The radiation dose without a shield was 1.540 mGy, and that using a collimator was measured 0.506 mGy. Moreover, 0.733 mGy was measured when 1 shield (0.3 mm) was used, and $0.523{\mu}Gy$ when 5 of them (1.5 mm) were used. The results showed that the radiation dose with 5 shields and the radiation dose with a collimator were similar. Moreover, 0.233 mGy was measured when 8 shields (2.4 mm) were used. The standard deviation were 0.081 when using collimator and 0.014 when 5 shields were used. Also, when 8 shields were used, it was found to be 0.002. Most patients who go under a scoliosis test are children or young people who are highly sensitive to radiation. In the research results, the case where the organs sensitive to radiation, women's breasts, were shielded showed more distinct differences compared to without shields. It is considered that using shields can provide more constant shield than using a collimator and lower the risk of breast cancer caused by exposure to radiation.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

Patient Radiation Exposure Dose Evaluation of Whole Spine Scanography Due to Exposure Direction (Whole Spine Scanography의 검사방향에 따른 환자 선량 평가)

  • Kim, Jung-Su;Seo, Deok-Nam;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Whole spine scanography (WSS) is a radiological examination that exposes the whole body of the individual being examined to x-ray radiation. WSS is often repeated during the treatment period, which results in a much greater radiation exposure than that in routine x-ray examinations. The aims of the current study were to evaluate the patient dose of WSS using computer simulation, image magnification and angulation of phantom image using different patient position. We evaluated the effective dose(ED) of 23 consecutive patients (M : F = 13:10) who underwent WSS, based on the automatic image pasting method for multiple exposure digital radiography. The Anterior-Posterior position(AP) and Posterior-Anterior position( PA) projection EDs were evaluated based on the PC based Monte Carlo simulation. We measured spine transverse process distance and angulation using DICOM measurement. For all patient, the average ED was 0.069 mSv for AP position and 0.0361 mSv for PA position. AP position calculated double exposure then PA position. For male patient, the average ED was 0.089 mSv(AP) and 0.050 mSv(PA). For female patient, the average ED was 0.0431 mSv(AP) and 0.026 mSv(PA). The transverse process of PA spine image measured 5% higher than AP but angulation of transverse process was no significant differences. In clinical practice, just by change the patient position was conformed to reduce the ED of patient. Therefor we need to redefine of protocol for digital radiography such as WSS. whole spine scanography, effective dose, patient exposure dose, exposure direction. protocol optimization.

Effect of Field Size on the Clinical Exposure Index for Lumbar Spine X-ray Examination (노출지수를 이용한 요추 X선 촬영의 조사야 유효성 평가)

  • Park, Hyemin;Yoon, Yongsu;Kim, Jungsu;Jeong, Hoiwoun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.183-187
    • /
    • 2021
  • The field size of the lumbar spine X-ray examination, which belongs to the most frequent examination in general radiography, is 5 times wider than the width of the lumbar spine. Exposure index (EI) as per International Electrotechnical Commission has a proportional relationship with the dose incident on the image receptor for clinical protocols in addition to RQA5, which is a calibration beam quality. In this study, the effectiveness of the set field size was evaluated through the change of EI according to the size of field during lumbar spine X-ray examinations. Lumbar anterior-posterior and lateral examinations was performed using a whole-body phantom, and the national average exposure conditions of Korea investigated in 2017 were introduced for the X-ray exposure. As a result of comparing the EI displayed on the console of digital radiography system for the three field size in ① 18 × 36 cm2 ② 25 × 36 cm2 ③ 36 × 36 cm2, the EI values showed a tendency to increase as the field size increased. Since the patient dose, such as organ dose around the lumbar spine, increases as the field size becomes larger, thus, if the EI obtained from the field size at a level that does not interfere with diagnosis is set as a reference, the effectiveness of the field size can be evaluated through the EI displayed on the console when the lumbar spine X-ray examination is conducted.

The Study of Effectiveness of 3 Spot DR for the Whole Spine Radiography with Comparison of Phantom Distortions (3 Spot DR를 이용한 척추 전장 촬영 시 모형 왜곡도 비교를 통한 유용성 연구)

  • Kim, Sang-Hyun;Lee, Mi-Hwa
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.345-351
    • /
    • 2014
  • The purpose of this study is to offer more accurate information in whole spine examination of 3 spot DR through the comparative study about image distortion as making the flat phantom and measuring horizontal, vertical ratio and cobb angle of the virtual. We produced $H(40cm){\times}V(116cm){\times}D(2.3cm)$ flat acrylic phantom with lattice type of lead plate. We took projection respectively 3 times, total 9 times in each equipments using manufactured phantom as changing OFD to 6, 12, 18 cm. We measured a horizontal and vertical length of lead lattice and calculated the ratio. As appointing arbitrary points in the phantom and we measured cobb angle. The results of horizontal, vertical ratio measured CR type 0.98~1.01, scan DR type 0.96~0.97 and 3 spot DR 0.99~1.01. Cobb angle measured $52.5{\sim}53.3^{\circ}$, $52.1{\sim}54.3^{\circ}$ and $52.8{\sim}53.2^{\circ}$. Finally we can say that 3 spot DR method is an accurate method without any distortion in whole spine radiography.

Evaluation of computed tomographic and radiographic myelography in normal miniature pigs

  • Choi, Mihyun;Lee, Hyeyeon;Kim, Mieun;Kim, Junyoung;Lee, Namsoon;Chang, Jinhwa;Jung, Joohyun;Choi, Mincheol
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.1
    • /
    • pp.37-42
    • /
    • 2010
  • Evaluation of the myelography was studied in miniature pigs. Radiographs and computed tomographic (CT) images of the whole spine were obtained at clinically healthy twelve miniature pigs of 4 (8.7-10 kg) and 12 (26-31 kg) months. The assessments of the spinal cord were made in accordance with the Pavlov's method and compared area ratio [at spinal cord (SC), vertebral canal (VC) and vertebral body (VB)]. The Pavlov's ratio in the cervical spine was significant larger than that of thoracolumbar in radiographic myelography. On CT myelography, the area of the spinal cord had a significant difference between the cervical and thoracolumbar spine. Among the cervical spine, the ratios of spinal cord and vertebral body (SC : VB), vertebral canal and vertebral body (VC : VB) were minimum at the level of 4th cervical spine in both ages, while maximum at the level of 6th cervical spine in both months. In case of lumbar spine, the ratios of spinal cord and vertebral body (SC : VB) were the largest at the level of 4th lumbar spine in 4 months and at the level of 3rd lumbar spine in 12 months. In addition, the ratio of spinal cord and vertebral body (SC : VB) of the cervical spinal cord was significant lower at 4 months but the lumbar spinal cord showed lower pattern at 12 months old miniature pigs.

Surgical Outcomes after Traumatic Vertebral Fractures in Patients with Ankylosing Spondylitis

  • An, Seong-Bae;Kim, Keung-Nyun;Chin, Dong-Kyu;Kim, Keun-Su;Cho, Yong-Eun;Kuh, Sung-Uk
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.2
    • /
    • pp.108-113
    • /
    • 2014
  • Objective : Ankylosing spondylitis is an inflammatory rheumatic disease mainly affecting the axial skeleton. The rigid spine may secondarily develop osteoporosis, further increasing the risk of spinal fracture. In this study, we reviewed fractures in patients with ankylosing spondylitis that had been clinically diagnosed to better define the mechanism of injury, associated neurological deficit, predisposing factors, and management strategies. Methods : Between January 2003 and December 2013, 12 patients with 13 fractures with neurological complications were treated. Neuroimaging evaluation was obtained in all patients by using plain radiography, CT scan, and MR imaging. The ASIA Impairment Scale was used in order to evaluate the neurologic status of the patients. Management was based on the presence or absence of spinal instability. Results : A total of 9 cervical and 4 thoracolumbar fractures were identified in a review of patients in whom ankylosing spondylitis had been diagnosed. Of these, 7 fractures were associated with a hyperextension mechanism. 10 cases resulted in a fracture by minor trauma. Posttraumatic neurological deficits were demonstrated in 11 cases and neurological improvement after surgery was observed in 5 of these cases. Conclusions : Patients with ankylosing spondylitis are highly susceptible to spinal fracture and spinal cord injury even after only mild trauma. Initial CT or MR imaging of the whole spine is recommended even if the patient's symptoms are mild. The patient should also have early surgical stabilization to correct spinal deformity and avoid worsening of the patient's neurological status.

Dose Reduction of the Adolescent Female Breast during Scoliosis Radiography (청소년기 여성의 척추측만증 검사에서 유방입사선량 저감효과)

  • Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.373-379
    • /
    • 2018
  • The purpose of this study was to investigate quantitative data on the difference in breast entrance surface dose with changes in focus-film distance, patient posture (anteroposterior-posteroanterior), thoracic wall thickness, rib bone thickness, lung tissue thickness, tube voltage, and high-voltage rectification method in Whole Spine Scanography, which is necessary for the treatment of scoliosis patients. Given a tube voltage of 90 kVp, kerma of 0.1 mGy, focus-film distance of 260 cm, tube voltage ripple rate of 0, filter thickness of 3.5 mm, and thickness of patient's thoracic wall of 120 mm as an X-ray exposure condition, from the simulation results using the Simulation of X-ray Spectra program to confirm the reduction effect of breast entrance surface dose according to the patient's posture (AP and PA), there was a dose reduction effect in aluminum filter thickness of 2.6 times at 3.5 mm, 25.7 times the thoracic wall thickness at 120 mm, 1.43 times higher tube voltage, and 0 to 1.14 times the tube voltage ripple rate. The total dose reduction effect was about 109 times. In order to confirm the dose reduction effect of RANDO phantom posture (AP and PA), from the results of the measurements taken under the conditions that the focus-film distance was 260 cm, the tube voltage was 90 kVp, the tube current was 270 mA, the exposure time was 0.31 sec, and the tube voltage ripple rate of X-ray generators was 0, the entrance surface dose reduction effect of the breast in the PA position was found to be 20.56 times lower than that of the AP position.