• 제목/요약/키워드: White-Light Interferometry

검색결과 63건 처리시간 0.028초

Absolute Temperature Measurement using White Light Interferometry

  • Kim, Jeong-Gon
    • Journal of the Optical Society of Korea
    • /
    • 제4권2호
    • /
    • pp.89-93
    • /
    • 2000
  • Recently a new signal processing algorithm for white light interferometry was presented. In this paper, the proposed signal processing algorithm was applied for absolute temperature measurement using white light interferometry. Stability testing and absolute temperature measurement were demonstrated. Stability test demonstrated the feasibility of absolute temperature measurement with an accuracy of 0.015 fringe. The test also showed that the absolute temperature measurement system using white light interferometry is capable of obtaining the theoretical minimum detectable change (0.0005 fringe), which is consistent with the performance predicted by the proposed signal processing algorithm.

자유 곡면 형상 측정을 위한 백색광 주사 간섭계의 정확도 향상 및 시스템 오차 분석 (Accuracy Improvement and Systematic Bias Analysis of Scanning White Light Interferometry for Free-form Surfaces Measurements)

  • 김영식;;이혁교
    • 한국정밀공학회지
    • /
    • 제31권7호
    • /
    • pp.605-613
    • /
    • 2014
  • Scanning white-light interferometry is an important measurement option for many surfaces. However, serious profile measurement errors can be present when measuring free-form surfaces being highly curved or tilted. When the object surface slope is not zero, the object and reference rays are no longer common path and optical aberrations impact the measurement. Aberrations mainly occur at the beam splitter in the interference objective and from misalignment in the optical system. Both effects distort the white-light interference signal when the surface slope is not zero. In this paper, we describe a modified version of white-light interferometry for eliminating these measurement errors and improving the accuracy of white-light interferometry. Moreover, we report systematic errors that are caused by optical aberrations when the object is not flat, and compare our proposed method with the conventional processing algorithm using the random ball test.

광 간섭계의 측정 정밀도와 구동 정밀도의 관계 (The effects of moving accuracy on inteferometric 3D shape measurement)

  • 박민철;엄창용;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.110-113
    • /
    • 2001
  • We present an interferometer system, which is able to perform both the phase shifting interferometry and white light interferometry. The interferometer system uses a d.c. motor to control the probe position with an accuracy of 10nm, which shows an outstanding performance on white light interferometry. However, the moving mechanism of d.c. motor is not accurate enough for the phase shifting interferometry that requires a moving precision less than 1 nm. We therefore propose a Fourier transform technique to calculate the phase of interferograms, which is strongly resistant to calibration errors and external vibration. Experimental results show that the Fourier transform technique is capable of reducing the measurement error caused by inaccurate movement within 0.1nm.

  • PDF

Methods to Measure the Critical Dimension of the Bottoms of Through-Silicon Vias Using White-Light Scanning Interferometry

  • Hyun, Changhong;Kim, Seongryong;Pahk, Heuijae
    • Journal of the Optical Society of Korea
    • /
    • 제18권5호
    • /
    • pp.531-537
    • /
    • 2014
  • Through-silicon vias (TSVs) are fine, deep holes fabricated for connecting vertically stacked wafers during three-dimensional packaging of semiconductors. Measurement of the TSV geometry is very important because TSVs that are not manufactured as designed can cause many problems, and measuring the critical dimension (CD) of TSVs becomes more and more important, along with depth measurement. Applying white-light scanning interferometry to TSV measurement, especially the bottom CD measurement, is difficult due to the attenuation of light around the edge of the bottom of the hole when using a low numerical aperture. In this paper we propose and demonstrate four bottom CD measurement methods for TSVs: the cross section method, profile analysis method, tomographic image analysis method, and the two-dimensional Gaussian fitting method. To verify and demonstrate these methods, a practical TSV sample with a high aspect ratio of 11.2 is prepared and tested. The results from the proposed measurement methods using white-light scanning interferometry are compared to results from scanning electron microscope (SEM) measurements. The accuracy is highest for the cross section method, with an error of 3.5%, while a relative repeatability of 3.2% is achieved by the two-dimensional Gaussian fitting method.

백색광 간섭계의 위상 정점 알고리즘에서 조명에 따른 위상 정점 모호성에 관한 연구 (Phase Peak Ambiguity According to Illumination in White-Light Phase-Shifting Interferometry)

  • 김기홍;이형석
    • 한국정밀공학회지
    • /
    • 제25권1호
    • /
    • pp.85-91
    • /
    • 2008
  • White light scanning interferometry has gotten a firm position in 3D surface profile measuring field. Recently, the LCD industry gave a chance for this technology to enter into real industry fields. It is known that white-light phase-shifting algorithm give a best resolution compare to other algorithms, but there are some problems to be resolved. One of them is 300nm jump in height profile, called bat-wing effect. The main reason of this problem is an ambiguity of phase-peak detection algorithm, and some solution has been proposed, but it didn't work perfectly. In this paper, I will show the cases when these effects are occurred, and these height discrepancies will be almost disappeared when broad-band illuminators are used.

분산형 백색광 간섭계를 이용한 미세 박막 구조물의 삼차원 두께 형상 및 굴절률의 실시간 측정 (Dispersive White-light Interferometry for in-situ Volumetric Thickness Profile of Thin-film Layers and a refractive index)

  • 김영식;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.23-24
    • /
    • 2006
  • We present a dispersive scheme of white-light interferometry that enables not only to perform tomographical measurements of thin-film layers but also to measure a refractive index without mechanical depth scanning. The interferometry is found useful particularly for in-situ 3-D inspection of micro-engineered surfaces such as liquid crystal displays, semi-conductor and MEMS structure, which requires for high-speed implementation of 3-D surface metrology.

  • PDF

Generating a True Color Image with Data from Scanning White-Light Interferometry by Using a Fourier Transform

  • Kim, Jin-Yong;Kim, Seungjae;Kim, Min-Gyu;Pahk, Heui Jae
    • Current Optics and Photonics
    • /
    • 제3권5호
    • /
    • pp.408-414
    • /
    • 2019
  • In this paper we propose a method to generate a true color image in scanning white-light interferometry (SWLI). Previously, a true color image was obtained by using a color camera, or an RGB multichannel light source. Here we focused on acquiring a true color image without any hardware changes in basic SWLI, in which a monochrome camera is utilized. A Fourier transform method was used to obtain the spectral intensity distributions of the light reflected from the sample. RGB filtering was applied to the intensity distributions, to determine RGB values from the spectral intensity. Through color corrections, a true color image was generated from the RGB values. The image generated by the proposed method was verified on the basis of the RGB distance and peak signal-to-noise ratio analysis for its effectiveness.

백색광 주사간섭계의 생물학적 응용 (Biological Applications of White Light Scanning Interferometry)

  • 김기우
    • Applied Microscopy
    • /
    • 제41권4호
    • /
    • pp.223-228
    • /
    • 2011
  • 백색광 주사간섭계는 다양한 시료의 표면 특성을 분석하기 위하여 널리 활용되고 있다. 이 기법은 재료공학 분야에서 오래 전부터 이용되었으며 정성적인 형상 이미지 이외에도 정량적인 3차원 결과를 제공한다. 이 기법에서는 백색광을 광원으로 이용하는데, 기준면과 측정면에서의 반사광을 합쳐서 형성되는 간섭신호를 형태 정보로 활용한다. z축 결과인 고도는 회색수준으로 구분되어 제시된다. 이 기법을 통하여 대영역으로 생물 시료를 신속하고 비파괴적으로 형태를 계측할 수 있다. 연골세포, 치아 법랑질, 식물 잎을 대상으로 적용한 사례가 있다. 특히 표면 구조물의 폭, 길이, 경사각과 같은 특성도 이 기법을 통하여 정량화할 수 있다. 이 기법을 적용하기 위하여 일정 수준의 반사도가 필요한데, 식물 잎에서의 반사도는 그 요건을 충족하였다. 전도성 금속의 코팅 등 부가적인 시료 전처리가 필요 없으므로 이 기법을 통한 생물 시료의 정량적 측정이 더욱 증가할 것으로 예상한다.