• 제목/요약/키워드: White Blood Cells

검색결과 378건 처리시간 0.022초

혈액 세포의 고유자성을 이용한 마이크로 자기영동 세포분리기 (Magnetophoretic Microseparators for Separating Blood Cells Based on Their Native Magnetic Properties)

  • 정진희;한기호
    • 대한기계학회논문집B
    • /
    • 제32권11호
    • /
    • pp.856-862
    • /
    • 2008
  • This paper presents the characterization of a continuous magnetophoretic microseparator for separating white and red blood cells from peripheral whole blood cells based on their native magnetic properties. The magnetophoretic microseparator separated the blood cells using a high gradient magnetic separation (HGMS) method without the use of additives such as magnetic beads or probing materials. Experimental results show that the paramagnetic capture mode microseparator can continuously separate out 93.5% of red blood cells and 97.4% of white blood cells from diluted whole blood, and the diamagnetic capture mode microseparator can continuously separate out 89.7% of red blood cells and 72.7 % of white blood cells by using applying an external magnetic flux of 0.2 T using a permanent magnet.

White Blood Cell Types Classification Using Deep Learning Models

  • Bagido, Rufaidah Ali;Alzahrani, Manar;Arif, Muhammad
    • International Journal of Computer Science & Network Security
    • /
    • 제21권9호
    • /
    • pp.223-229
    • /
    • 2021
  • Classification of different blood cell types is an essential task for human's medical treatment. The white blood cells have different types of cells. Counting total White Blood Cells (WBC) and differential of the WBC types are required by the physicians to diagnose the disease correctly. This paper used transfer learning methods to the pre-trained deep learning models to classify different WBCs. The best pre-trained model was Inception ResNetV2 with Adam optimizer that produced classification accuracy of 98.4% for the dataset comprising four types of WBCs.

Microsystems for Whole Blood Purification and Electrophysiological Analysis

  • Han, Arum;Han, Ki-Ho;Mohanty Swomitra K.;Frazier A. Bruno
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제5권1호
    • /
    • pp.1-10
    • /
    • 2005
  • This paper presents the development of a microsystem for whole blood purification and electrophysiological analysis of the purified cells. Magnetophoresis using continuous diamagnetic capture (DMC) was utilized for whole cell purification and electrical impedance spectroscopy (EIS) was utilized for electrophysiological analysis of the purified cells. The system was developed on silicon and plastic substrates utilizing conventional microfabrication technologies and plastic microfabrication technologies. Using the magnetophoretic microseparator, white blood cells were purified from a sample of whole blood. The experimental results of the DMC microseparator show that 89.7% of the red blood cells (RBCs) and 72.7% of the white blood cells (WBCs) could be continuously separated out from a whole blood using an external magnetic flux of 0.2 T. EIS was used as a downstream whole cell analysis tool to study the electrophysiological characteristics of purified cells. In this work, primary cultured bovine chromaffin cells and human red blood cells were characterized using EIS. Further analysis capabilities of the EIS were demonstrated by successfully obtaining unique impedance signatures for chromaffin cells based on the whole cell ion channel activity.

Comparison of the methods for platelet rich plasma preparation in horses

  • Lee, Eun-bee;Kim, Jung-Won;Seo, Jong-pil
    • Journal of Animal Science and Technology
    • /
    • 제60권8호
    • /
    • pp.20.1-20.4
    • /
    • 2018
  • Platelet rich plasma (PRP) is popularly used in the horse industry to enhance regeneration of tissue injury that has limitation of blood supply. This study aimed to compare the methods for platelet rich plasma preparation since they has not been established yet. Blood was collected from six horses and platelets were concentrated by three different methods (2-step centrifugation, separated centrifugation and separated centrifugation using histopaque). Concentrated blood was analyzed using Advia hematology systems. In the result, separated centrifugation with histopaque showed the significantly lower number of red blood cells than other groups. The 2-step centrifugation showed the significantly higher number of white blood cells than other groups, while it contained the highest concentration of red blood cells among three groups. In the 2-step centrifugation, separated centrifugation and separated centrifugation with histopaque, platelets were concentrated 4.5, 5.3 and 5.6 times, respectively. And no significant difference of the platelet concentration between the three groups was found. This study demonstrated that separated centrifugation using histopaque was the best method for platelet rich plasma preparation because of the proper amount of platelets and the separation of red blood cells from platelet rich plasma.

Classification of White Blood Cell Using Adaptive Active Contour

  • Theerapattanakul, J.;Plodpai, J.;Mooyen, S.;Pintavirooj, C.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1889-1891
    • /
    • 2004
  • The differential white blood cell count plays an important role in the diagnosis of different diseases. It is a tedious task to count these classes of cell manually. An automatic counter using computer vision helps to perform this medical test rapidly and accurately. Most commercial-available automatic white blood cell analysis composed mainly 3 steps including segmentation, feature extraction and classification. In this paper we concentrate on the first step in automatic white-blood-cell analysis by proposing a segmentation scheme that utilizes a benefit of active contour. Specifically, the binary image is obtained by thresolding of the input blood smear image. The initial shape of active is then placed roughly inside the white blood cell and allowed to grow to fit the shape of individual white blood cell. The white blood cell is then separated using the extracted contour. The force that drives the active contour is the combination of gradient vector flow force and balloon force. Our purposed technique can handle very promising to separate the remaining red blood cells.

  • PDF

고양이 말초혈액 탐식세포의 탐식능에 있어서 계난백유래물질의 효과 (Effect of Egg White Derivatives on Phagocytic Response of Feline Peripheral Blood Phagocytes)

  • 양만표;김기홍
    • 한국임상수의학회지
    • /
    • 제16권1호
    • /
    • pp.37-41
    • /
    • 1999
  • The immunostimulating effects of egg white derivatives (EWD) on the phagocytic response of feline peripheral blood polymorphonuclear cells (PMN) as well as mono- nuclear cells (MNC) were examined. The phagocytic activity was analyzed by a flow cytometry system. The EWD showed directly an enhanced effect on the phagocytic response of MNC but not PMN. The phagocytic activity of MNC was enhanced by culture supernatant from MNC and PMN treated with EWD, respectively. Similarly, the phagocytic activity of PMN was enhanced by culture supernatant from MNC but not PMN treated with EWD. It was, therefore, indicated that the enhanced phagocytic activity of feline PMN could be mainly mediated by humoral factor(s) released from MNC treated with EWD. These results suggested that EWD could enhance the phagocytosis of feline peripheral blood phagocytes.

  • PDF

진공채혈관의 상태에 따른 평가 (Evaluation of Vacutainer Distribution Conditions)

  • 박창은
    • 대한임상검사과학회지
    • /
    • 제48권2호
    • /
    • pp.109-113
    • /
    • 2016
  • 분석전 변이로 인하여 검사실은 오류에 직면하게 되고 많은 요인들은 환자의 검사결과에 영향을 미치게 된다. 다양한 진공채혈관은 신속하게 분리하고 방치된 검체의 용혈을 방지한다. 그러나 진공채혈관의 상태에 따라 몇 가지 제한점들이 발생하는데 이러한 문제점을 알아보기 위해 다양한 진공채혈관을 이용해 혈구산정검사로 비교 평가하였다. 유통기한별 검사결과에서는 백혈구(WBC)와 혈소판(PLT)의 값에서 0.24, 0.21로 큰 변이계수를 나타냈고 상관성에서는 백혈구(WBC), 혈소판(PLT), 적혈구(RBC)의 값이 유의성을 보였다(p<0.01). 한편 각 3사의 비교평가에서는 백혈구(WBC), 혈소판(PLT)의 값에서 0.27, 0.21로 가장 큰 변이계수를 나타냈고, 상관성에서는 각 3사가 모두 백혈구(WBC), 혈소판(PLT), 혈소판분포폭(PDW)의 값에서 높은 유의한 차이를 보였다(p<0.01) 그러나 G사와 B사는 혈소판(PLT), 혈소판분포폭(PDW)의 값에서는 낮은 유의한 차이를 보였다(p<0.05). 결론적으로 진공채혈관의 상태에 따른 분석의 안정성을 위해 적절한 진공채혈관의 분석평가가 이루어져야 한다.

고진음자(固眞飮子)가 methotrexate로 유발된 흰쥐의 면역기능저하(免疫機能低下)에 미치는 영향(影響) (Effects of Gojineumja on Immunosuppression Induced by Methotrexate in Rat)

  • 강대원;강석봉
    • 대한한방내과학회지
    • /
    • 제25권4호
    • /
    • pp.117-128
    • /
    • 2004
  • Objectives : To examine the effects of Gojineumja on white rats which deteriorated immunity caused by Methotrexate(MTX), first of all, MTX was fed to the rats once a day for 4 day. Methods : After the immune response of the rats are deteriorated, dried extracts of Gojineumja(GJE) mixed in water was fed to the white rats once a day for l4days. The next conclusion was made by examining the rates of B-cells and T-cells of the peripheral blood and the changes in rates of CD4+ T-cells and CD8+ T -cells of the blood sampled from the spleen and peripheral region. Especially the count of CD3+ CD4+ T-cells of the peripheral blood and the count of CD3+ CD4+ T-cells of the spleen the count of CD4+/ CD8+ T-cell of the peripheral blood and the spleen proved the significant effect of increasing immune responses statistically. Results :(1) The following are the summary of the results. (2) The percentage of B lymphocyte of peripheral blood was increased significantly in GJE group as compared with control group. (3) The percentage of CD3+ CD4+ T-cell of peripheral blood was increased significantly in GJE group as compared with control group. (4) The percentage of CD3+ CD8+ T-cell of peripheral blood was not different statistically. (5) The percentage of CD4+/ CD8+ T-cell of peripheral blood was increased significantly in GJE group as compared with control group. (6) The percentage of CD3+ CD4+ T-cell of spleen was increased significantly in GJE group as compared with control group. (7) The percentage of CD3+ CD8+ T-cell was not different statistically. (8) The percentage of CD4+ /CD8+ T-cell was not different statistically. Conclusions : Gojineumja has an effect of increasing immune responses on white rats with deteriorated immunity caused by MTX.

  • PDF

전도성 액체기반 정상표면탄성파(CL-SSAW)를 이용한 백혈구로부터의 말라리아 기생충 분리 (Malaria Parasite Separation from White Blood Cells Using Conductive Liquid-Based Standing Surface Acoustic Wave (CL-SSAW))

  • 지현슬;남정훈;임채승
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권5호
    • /
    • pp.151-157
    • /
    • 2019
  • An acoustofluidic device using conductive liquid-based electrodes was developed for malaria parasite separation from white blood cells. In this device, the electrode channels filled with a conductive liquid were used to generate standing surface acoustic waves (SSAWs) in a fluidic channel, which can overcome the limitation of conventional patterned metal electrodes. Separation performance of the device was evaluated using fluorescent polystyrene particles with two different sizes (2 and $10{\mu}m$ diameters), which were successfully separated. In addition, a mixture of malaria parasites and white blood cells were also efficiently separated with high purity of ~98% in the CL-SSAW device at the flow rate of $12{\mu}l/min$.

Reference Values for Peripheral Blood Lymphocyte Subsets in a Healthy Korean Population

  • Choi, Joungbum;Lee, Su Jin;Lee, Yun A;Maeng, Hyung Gun;Lee, Jong Kyun;Kang, Yong Won
    • IMMUNE NETWORK
    • /
    • 제14권6호
    • /
    • pp.289-295
    • /
    • 2014
  • Flow cytometric immunophenotyping of peripheral blood lymphocyte subsets is a powerful tool for evaluating cellular immunity and monitoring immune-mediated diseases. The numbers and proportions of blood lymphocyte subsets are influenced by factors such as gender, age, ethnicity, and lifestyle. This study aimed to establish reference ranges for peripheral blood lymphocyte subsets in a healthy Korean population. Blood samples from 294 healthy adults were collected. Lymphocyte subsets were analyzed using a single-platform method with a flow cytometer; white blood cells and lymphocytes were analyzed using an automated hematology analyzer. The mean value of the white blood cell count was $5,665cells/{\mu}l$, and the mean values of the subtype counts (percentages) were as follows: lymphocytes, $1,928cells/{\mu}l$ (35.08%); $CD3^+$ cells, $1,305cells/{\mu}l$ (67.53%); $CD3^+CD4^+$ cells, $787cells/{\mu}l$ (40.55%); $CD3^+CD8^+$ cells, $479cells/{\mu}l$ (25.23%); $CD3^-CD19^+$ cells, $203cells/{\mu}l$ (10.43%); and $CD3^-CD56^+$ cells, $300cells/{\mu}l$ (15.63%). Additionally, the $CD4^+/CD8^+$ ratio was 1.81. In this study, gender and age significantly influenced blood lymphocyte subsets. Our results demonstrate that, as with other populations, a healthy Korean population has its own, region-specific, lymphocyte subset reference ranges.