The Effects of Operational Conditions of Cooling Water System on Energy Consumption for Central Cooling System (냉각수 계통의 운전변수가 중앙냉방시스템의 에너지소비량에 미치는 영향)

  • Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • 제13권4호
    • /
    • pp.8-13
    • /
    • 2017
  • The effects of operational conditions of cooling water system on energy consumption for central cooling system are researched by using TRNSYS program. Cooling tower water pump flow rate, cooling tower fan flow rate, and condenser water temperature with various dry-bulb and wet-bulb temperatures are varied and their effects on total and component power consumption are studied. If the fan maximum flow rates of cooling tower is decreased, cooling tower fan and total power consumptions are increased. If the cooling tower water pump maximum flow rates is decreased, chiller and total power consumptions are increased. If condenser water set-point temperature is increased, chiller power consumption is increased and cooling tower fan power consumption is decreased, respectively.

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • 제38권2호
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.

The Cooling Water Bypass Ratio of Packing in Plume Abatement Cooling Tower of a Combined Cycle Power Plant During Winter Operation (복합화력발전소 동계운전시 백연방지 냉각탑 냉각수의 충전재 바이패스 비율 확인)

  • Chung, Hee-Bong;Yoo, Hoseon
    • Plant Journal
    • /
    • 제14권4호
    • /
    • pp.33-38
    • /
    • 2018
  • In this study, it was confirmed whether the cooling water bypass ratio of packing for plume abatement matched designed value during winter operation of combined cycle power plant. Designed operating wet bulb temperature of the plume abatement cooling tower with 29 Gcal/h capacity had a range from $13^{\circ}C$ to $-20^{\circ}C$, while its designed bypass ratio was from 0 % to 78%, so that increasing rate of the designed bypass ratio was $2.36%/^{\circ}C$ when the external temperature decreased. When the wet bulb temperature at cooling tower inlet had a range from $7.8^{\circ}C$ to $-11.8^{\circ}C$ in a normal operation, it was measured that actual bypass ratio of packing for plume abatement had a range from 23.8 % to 74.3%. While increasing rate of the actual bypass ratio was $2.71%/^{\circ}C$ in a range from $7.8^{\circ}C$ to $-9.55^{\circ}C$, it was $1.61%/^{\circ}C$ under $-10^{\circ}C$ in cold weather condition according to atmospheric temperature drop, therefore it was confirmed that the increasing rate of the bypass ratio for packing was lowered than its design.

  • PDF

Assessment of Semen Quality among Workers Exposed to Heat Stress: A Cross-Sectional Study in a Steel Industry

  • Hamerezaee, Masoud;Dehghan, Somayeh F.;Golbabaei, Farideh;Fathi, Asad;Barzegar, Loghman;Heidarnejad, Naseh
    • Safety and Health at Work
    • /
    • 제9권2호
    • /
    • pp.232-235
    • /
    • 2018
  • Background: This study was conducted to investigate the heat stress and semen quality among male workers in a steel industry in Iran and investigate the relationship between heat stress indices and semen parameters. Methods: The study was conducted on workers exposed (n = 30) and unexposed (n = 14) to heat in a steel industry. After obtaining a brief biography of the selected employees, scrotal temperature, oral temperature, and environmental parameters were measured, and their semen samples were analyzed according to the procedure recommended by the World Health Organization. The heat stress indices, including wet-bulb globe temperature (WBGT) and predicted heat strain (PHS), in their workplace were calculated according to environmental parameters (ISO 7243:1989 and 7933:2004, respectively). Results: Time-weighted averages of WBGT and PHS ($35.76^{\circ}C$ and 491.56 $w/m^2{\frac{w}{m^2}}$, respectively) for the exposed group were higher than threshold limit values. The mean difference of environmental, physiological, and semen parameters (exception: pH of semen), and also WBGT and PHS indices were statistically significant (p < 0.05) between the two groups. Mean semen parameters were in the normozoospermic range. WBGT and PHS indices showed significantly "negative" correlation with physiological parameters (scrotal and oral temperature) and most semen parameters (semen volume, sperm morphology, sperm motility, sperm count; p < 0.05); moreover, the correlation of WBGT with these parameters was stronger than PHS. Conclusion: Semen parameters of the studied workers exposed to heat were in the borderline level of normozoospermic range, and their semen parameters were significantly lower than controls. For better assessment of occupational environment concerning physiological and semen parameters in steel industries, WBGT can be a more useful index.

An Experimental Study on the Effect of the Air Temperature on the Air-Side Heat-Transfer Coefficient and the Friction Factor of a Fin-and-Tube Heat Exchanger (외기 온도 변화가 핀-관 열교환기의 공기측 열전달계수와 마찰계수에 미치는 영향에 관한 실험적 연구)

  • Kim, Nae-Hyun;Cho, Honggi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제29권4호
    • /
    • pp.149-158
    • /
    • 2017
  • In general, the air-side j and f factors of evaporators or condensers are obtained through single-design tests performed under air-dry and wet-bulb temperatures. Considering that the indoor or outdoor air temperatures vary significantly during the operation of an air conditioner, it is necessary to confirm that the experimentally-obtained j and f factors are widely applicable under variable air conditions. In this study, a series of tests were conducted on a two-row slit-finned heat exchanger to confirm the applicability. The results showed that, for the dry-surface condition, the changes of the tube-side water temperature, water-flow rate, and air temperature had virtually no effect on the air-side j and f factors. For the wet condition, however, the f factor was significantly affected by these changes; contrarily, the j factor is relatively independent regarding this change. The formulation of the possible reasoning is in consideration of the condensation behavior underneath the tube. The wet-surface j and f factors are larger than those of the dry surface, with a larger amount for the f factor.

The Burdens of Occupational Heat Exposure-related Symptoms and Contributing Factors Among Workers in Sugarcane Factories in Ethiopia: Heat Stress Wet Bulb Globe Temperature Meter

  • Mitiku B. Debela;Achenef M. Begosaw;Negussie Deyessa;Muluken Azage
    • Safety and Health at Work
    • /
    • 제14권3호
    • /
    • pp.325-331
    • /
    • 2023
  • Background: Heat stress is a harmful physical hazard in many occupational settings. However, consequences of occupational heat exposure among workers in a sugarcane factory in Ethiopia are not well characterized. This study aimed to assess the level of occupational heat exposure-related symptoms and contributing factors. Methods: In this cross-sectional study, five workstations were selected for temperature measurement. Heat stress levels were measured using a wet-bulb globe temperature index meter. A stratified random sampling technique was used to select 1,524 participants. Heat-related symptoms were assessed using validated questionnaires. Results: The level of occupational heat exposure was 72.4% (95% CI: 70.2%-74.8%), while 71.6% (95% CI: 69.3%-74.9%) of participants experienced at least one symptom related to heat stress. The most common heat-related symptoms were swelling of hands and feet (78%), severe thirst (77.8%) and dry mouth (77.4%). The identified risk factors were a lack of reflective shields (AOR: 2.20, 95% CI: 1.53, 3.17), not-enclosed extreme heat sources (AOR: 1.76, 95% CI: 1.23, 2.51), a lack of access to shade (AOR: 9.62, 95% CI: 6.20, 14.92), and inappropriate protective clothing provision (AOR: 1.58, 95% CI: 1.27, 2.71). Conclusions: The burden of occupational heat exposure and heat-induced symptoms was high. Lack of reflective shields, the absence of enclosed extreme heat sources, a lack of access to shade, and inappropriate protective clothing provision were considerable attributes of heat stress. Therefore, the use of mechanical solutions to stop heat emissions at their sources and the key factors identified were areas for future intervention.

Program Development for the Prediction of Cooling Tower Performance (냉각탑 성능 예측을 위한 프로그램 개발)

  • Jung, Jaehyung;Jung, Jaihyun;Choi, Young Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제26권3호
    • /
    • pp.130-136
    • /
    • 2014
  • The present study is performed to set up the framework of cooling tower performance predictions. The performance of mechanical forced draft cooling tower is directly related to the state of a nuclear power plant system, such as the condenser and evaporator. The main parameters related to the state of systems are as follows : wet bulb temperature, dry bulb temperature and absolute humidity. The performance evaluation of cooling tower must be considered at the power plant design. In this study, the toolkit developed by the American Cooling Tower Industry association (CTI) has been used for the framework construction. In order to validate the framework, it is being applied to the cooling tower constructed for the U.S. Nuclear Power Plant. The test results have shown good agreements with the cold water temperature on the cooling tower performance curves provided by manufacturers.

An Analysis of Thermal Comforts for Pedestrians by WBGT Measurement on the Urban Street Greens (도심 가로 녹음의 습구흑구온도(WBGT) 측정을 통한 보행자 열쾌적성 효과 분석)

  • Ahn, Tong-Mahn;Lee, Jae-Won;Kim, Bo-Ram;Yoon, Ho-Seon;Son, Seung-Woo;Choi, Yoo;Lee, Na-Rae;Lee, Ji-Young;Kim, Hae-Ryung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • 제41권3호
    • /
    • pp.22-30
    • /
    • 2013
  • This study aims to measure the thermal comfort effects of urban street trees. As the usual dry bulb air temperature does not indicate properly how the average pedestrian feels the heat of a typical summer day under the strong sunshine, we adopted the Wet Bulb Globe Temperature(WBGT). WBGT involves black globe temperature to measure the direct radiation of sun beams on our bodies, for example our heads. We measured temperatures on very sunny and hot summer days, August 3, 4, and 7, 2012, on the urban streets of Seoul, Korea. Wet bulb, globe, and dry bulb temperatures were measured under direct sunlight from 1 O'clock to 5 O'clock pm. Globe and dry bulb temperatures were measured under street tree shades nearby during the same hours. Then the WBGTs were calculated with the formulae, one for sunny outdoor spaces, and the other for shaded outdoor spaces or indoor. The results are compared with the Korean Standards Association(KS A ISO 7243). The major findings were: 1) On very sunny and hot summer days in Seoul, street tree shades lower the WBGT about 1 to 4 degrees, 2) during the hours of 3 and 4 O'clock in the afternoon, the WBGT under the tree shades are about 3 to 4 degrees lower compared to those under sunshines(approx. 29 to 32 degrees respectively), 3) This difference makes a major thermal comfort for urban pedestrians because senior citizens or weak persons are recommended to move indoor, and even healthy people are recommended stop outdoor sports and take rests in the shades when WBGT is about 32. On the other hand, if the WBGT is around 29, or 3 degrees lower, slower walking, light works or sports are allowable, 4) On site questionnaire survey confirms the thermal comforts under the tree shades, and we even could not get survey subjects on the sunny parts of the sidewalks, 5) We strongly recommend change of guidelines for urban street trees from "one row of street trees on 6m~8m intervals" to "street trees to make continuous shades".

Sensitivity Analysis on KS and JIS Standard for Heat Recovery Ventilator (KS, JIS 열교환 환기장치 실험규격의 민감도 분석)

  • Yee Jurng-Jae;Ihm Pyeong-Chan;Kim Hwan-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제17권11호
    • /
    • pp.998-1004
    • /
    • 2005
  • Recently natural ventilation rate is decreased due to the airtightness of apartment building. Therefore the use of heat recovery ventilator (HRV) has been greatly increased as an alternative method to supply fresh air and save energy in the building. In this research the experiment standard of HRV is compared between KS and JIS and the sensitivity analyses are experimented by both standards. Under cooling experiment condition indoor and outdoor wet-bulb temperature difference of JIS is 2 to 3 times higher than that of KS. It shows that the efficiency measurement of HRV by KS is expected to have greater sensitivity than by JIS and thus accurate measurement of web-bulb temperature is required. The experimental results provide that the efficiency of thermal exchange is resemblance to each others between KS and JIS. Under cooling experiment condition the efficiency of humidity exchange by KS presents higher than by JIS, however, under heating experiment condition the efficiency by KS shows lower than by JIS, reversely.

Comparison and analysis of typical metrological data by in korea (대한민국의 지역별 표준기상데이터 비교분석)

  • Yoo, Ho-Chun;Noh, Kyoung-Hwan;Kang, Hyun-Gu;Shin, In-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.361-366
    • /
    • 2009
  • Amid the crisis of global climate change, interest in low carbon and energy-saving building has been increasingly growing. Korea is likely to be designated as one of the countries subject to CO2 reduction under the 'Post-2012 Climate System' The efforts to minimize the building energy has been made and in line with the increasing need of low carbon and eco-friendly building, a demand for building evaluation programs has been on the rise. However, the metro logical data which is necessary for such program has not been effectively provided and moreover, the source, calculation method and period remain uncertain. This study was intended to evaluate the regional typical metro logical data (ISO TRY) provided by Korean Solar Energy Society and compile the month of test reference years (TRY), and analyze the regional weather using dry-bulb temperature, wet-bulb temperature and solar irradiance which are regarded the representative metro logical data.