• Title/Summary/Keyword: Wet damping

Search Result 8, Processing Time 0.024 seconds

Wet Damping Estimation of the Segmented Hull Model using the Random Decrement Technique (랜덤 감쇠기법을 이용한 분할모형의 접수 감쇠계수 추정)

  • Kim, Yooil;Park, Sung-Gun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.4
    • /
    • pp.217-223
    • /
    • 2013
  • This paper presents the wet damping estimation of the segmented hull model using the random decrement technique together with the continuous wavelet transform. The tested 16 sea states are grouped together based on the speed of the ship in order to figure out the possible influence of the ship speed on the damping ratio. The measured time histories of vertical bending moment for each tested sea state were processed with random decrement technique to derive the free decay signal, from which the damping ratios are estimated. Also, the autocorrelation functions of the filtered signal were calculated and comparison was made with the free decay signal obtained from the random decrement technique. Then the wet damping ratios for each sea state group, as well as precise wet natural frequencies, are estimated by using continuous wavelet transform. It turned out that the wet natural frequencies derived from the measured signal did not show any significant discrepancy compared with those obtained by wet hammering test, whereas the damping ratio did. It was considered that the discrepancy of the damping ratio between in calm and moving water may be attributed to the viscous effects caused by dramatically different flow pattern and relative velocity between the vibrating structure and surrounding fluid particles.

Numerical Analysis of Damping Effect of Liquid Film on Material in High Speed Liquid Droplet Impingement

  • Sasaki, Hirotoshi;Ochiai, Naoya;Iga, Yuka
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.1
    • /
    • pp.57-65
    • /
    • 2016
  • By high speed Liquid Droplet Impingement (LDI) on material, fluid systems are seriously damaged, therefore, it is important for the solution of the erosion problem of fluid systems to consider the effect of material in LDI. In this study, by using an in-house fluid/material two-way coupled method which considers reflection and transmission of pressure, stress and velocity on the fluid/material interface, high-speed LDI on wet/dry material surface is simulated. As a result, in the case of LDI on wet surface, maximum equivalent stress are less than those of dry surface due to damping effect of liquid film. Empirical formula of the damping effect function is formulated with the fluid factors of LDI, which are impingement velocity, droplet diameter and thickness of liquid film on material surface.

A Controllable Micro Damper Using Magneto-Rheological Fluids (자기유변유체를 이용한 마이크로 가변형 댐퍼)

  • Kim, Ki-Duck;Sim, Won-Chul;Jeon, Do-Young;Choi, Bum-Kyoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.8
    • /
    • pp.41-45
    • /
    • 2000
  • This paper provides a new concept of the controllable micro damper using MR(Magneto Rheological)fluids. The damper is composed of four layers which are fabricated by wet etching. The Process of the fabrication is explained and the change of damping property is experimentally shown. Since the damping force is controllable by the applied magnetic field the vibration can be effectively absorbed.

  • PDF

Influence of connection detailing on the performance of wall-to-wall vertical connections under cyclic loading

  • Hemamalini, S.;Vidjeapriya, R.
    • Advances in concrete construction
    • /
    • v.9 no.5
    • /
    • pp.437-448
    • /
    • 2020
  • In high rise buildings that utilize precast large panel system for construction, the shear wall provides strength and stiffness during earthquakes. The performance of a wall panel system depends mainly on the type of connection used to transfer the forces from one wall element to another wall element. This paper presents an experimental investigation on different types of construction detailing of the precast wall to wall vertical connections under reverse cyclic loading. One of the commonly used connections in India to connect wall to wall panel is the loop bar connection. Hence for this study, three types of wet connections and one type of dry connection namely: Staggered loop bar connection, Equally spaced loop bar connection, U-Hook connection, and Channel connection respectively were used to connect the precast walls. One third scale model of the wall was used for this study. The main objective of the experimental work is to evaluate the performance of the wall to wall connections in terms of hysteretic behaviour, ultimate load carrying capacity, energy dissipation capacity, stiffness degradation, ductility, viscous damping ratio, and crack pattern. All the connections exhibited similar load carrying capacity. The U-Hook connection exhibited higher ductility and energy dissipation when compared to the other three connections.

Effects of Storage Temperature and Seed Treatment on Emergence and Growth Properties of Panax ginseng at Spring-sowing (저장온도 및 종자 처리가 봄파종 인삼 출아와 생장에 미치는 영향)

  • Suh, Su Jeoung;Yu, Jin;Jang, In Bok;Moon, Ji Won;Lee, Sung Woo;Jang, In Bae
    • Korean Journal of Medicinal Crop Science
    • /
    • v.26 no.5
    • /
    • pp.401-407
    • /
    • 2018
  • Background: In Korea, seeds of Panax ginseng C. A. Meyer need to be stored under cold temperature and high humidity condition for months to break physiological dormancy, making storage difficult until spring-sowing. This study was conducted to test the effects of seed storage conditions and seed treatment on the emergence of seedling after spring-sowing in a nursery greenhouse. Methods and Results: After dehiscence, endocarp dried seeds in mild or completely, and wet seeds were stored in $2^{\circ}C$ and $-3.5^{\circ}C$ during winter. Storage at $-3.5^{\circ}C$ resulted in a lower emergence rate (ER) than that at $2^{\circ}C$, and additional cold ($2^{\circ}C$) treatment before or after storage at $-3.5^{\circ}C$ increased the ER. Endocarp dehydration prevented pre-germination at $2^{\circ}C$ storage and increased the ER of seeds stored at $-3.5^{\circ}C$. ER was also dependent on the batch of seeds. However, seed treatments before sowing had only limited effects on ER. Root loss was the main reason for damping-off; prolonged cold storage of seeds increased damping-off, as the detection of pathogens was not high. Conclusions: This study showed that storage conditions such as temperature and moisture content of seeds, affect the ER after spring-sowing and vitality of seedlings, suggesting further attention on seed control for secure seedling stands after spring-sowing.

Shaking Table Tests of 1/3-Scale 3-Story Wet-Jointed Precast Concrete Large Panel Box Model (1/3축소 3층 습식접합 프리캐스트 콘크리트 대형판 입체모델의 진동대 실험)

  • 이한선
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.1
    • /
    • pp.115-127
    • /
    • 1993
  • 본 연구의 목적은 프리캐스트 콘크리트(P.C) 대형판 아파트 구조물에 대한 우리나라 내진설계기준안 및 지침을 수립하기 위해 필요로 하는 정보를 취득하는데 있다. 이것은 실제 지진과 유사한 진동을 발생시키는 진동대를 사용하여 P.C대형판 구조물의 거동을 분석관찰함으로써 달성되었다. 여기에 사용된 시험체중의 하나는 습식접합 1/3 축소 3층 입체 P.C모델이었다. 지진파를 일으키기 위해 4mx4m 크기의 진동대가 사용되었다. 또한 선택한 입력지진가속도파는 Taft N21E 성분기록지진파로서 최대지진가속도(PGA)는 원하는 지진세기수준에 따라 조정되었고 시간축으로는 동적상사성법칙에 따라 축소되었다. 이 P.C모델의 진동대 실험을 통해 얻은 결과를 근거로 하여, 근거로 하여 다음과 같은 결론을 도출하였다. (1)이 시험체에 관한한, 지진안전계수는 7-8정도로 나타났으며, (2)이 P.C모델이 감쇠계수는 대체로, 철근콘크리트구조물 감쇠계수의 두배에 해당하는 값인 8%정도이며, (3) 이 모델은 접합부의 벌어짐과 미끄러짐에 의한 에너지소산을 통해서 2-3정도의 전체적인 변위연성비를 보여주었다.

Rotordynamic Transient Analysis of Vertical Sea Water Lift Pump for FPSO Deep Well (FPSO 심정용 수직 해수펌프의 로터다이나믹 과도해석)

  • Kim, Byung-Ok;Yang, Sung-Jin;Lee, Myung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.5
    • /
    • pp.69-74
    • /
    • 2011
  • This paper deals with the detail rotordynamic analysis for the vertical rotor system as development of vertical sea water lift pump for FPSO deep well. In a vertical rotor system, since linearized stiffness and damping coefficients of fluid film bearing are no longer be valid, hence the transient response analysis considering a fluid film force for every journal position in the bearing needs to be required. In this study, the transient response analysis of the proposed vertical pump rotor system was carried out in dry-run and wet-run conditions, respectively. The results show that orbital vibration responses of the rotor system remain stable at rated speed and thereby operating reliability of the vertical rotor system is confirmed. To overcome complexity of calculation pr ocedure and time consuming calculation of transient analysis, the calculating technique of steady-state response analysis is also proposed. The results of steady-state response obtained by applying the proposed technique to the rotor system are good agreement with the reference results, that is, transient responses.

R&D Trend on Surface Treatment of Magnesium Alloys (마그네슘합금의 표면처리에 관한 연구개발 동향)

  • Shim, Jae-Dong;Byun, Ji-Young
    • Korean Journal of Materials Research
    • /
    • v.23 no.1
    • /
    • pp.72-80
    • /
    • 2013
  • Recently, consumption of magnesium alloys has increased especially in the 3C (computer, communication, camera) and automobile industries. The structural application of magnesium alloys has many advantages due to their low densities, high specific strength, excellent damping and anti-eletromagnetic properties, and easy recycling. However, practical application of these alloys has been limited to narrow uses of mild condition, because they are inferior in corrosion resistance and wear resistance due to their high chemical reactivity and low hardness. Various wet and dry processes are being used or are under development to enhance alloy surface properties. Various conversion coating and anodizing methods have been developed in a view of eco-friendly concept. The conventional technologies, such as diffusion coating, sol-gel coating, hydrothermal treatment, and organic coating, are expected to be newly applicable to magnesium alloys. Surface treatments for metallic luster or coloring are suggested using the control of the micro roughness. This report reviews the recent R&D trends and achievements in surface treatment technologies for magnesium alloys.