• Title/Summary/Keyword: Wet and Dry technique

Search Result 96, Processing Time 0.029 seconds

Development of Dry/Wet Algorithm for 2-Dimensional Flow Analysis (2차원 흐름해석을 위한 마름/젖음 알고리듬의 개발)

  • Kim, Sang-Ho;Han, Kun-Yeun;Choi, Seung-Yong;Oh, Hyun-Uk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.624-628
    • /
    • 2008
  • Two-dimensional flow analysis is a way to provide good estimates for complex flow features in flow around islands and obstructions, flow at confluence and flow in braided channel. One of difficult problems to develop a two-dimensional hydraulic model is to analyze dry and wet area in river channel. Dry/wet problem can be encountered in river and coastal engineering problems, such as flood propagation, dam break analysis, tidal processes and so on. The objective of this study is to develop an accurate and robust two-dimensional finite element method with dry/wet technique in complex natural rivers. The dry/wet technique with Deforming Grid Method was developed in this study. The Deforming Grid Method was used to construct new mesh by eliminating of dry nodes and elements. The eliminated nodes and elements were decided by considering of the rising/descending velocity of water surface elevation. Several numerical simulations were carried out to examine the performance of the Deforming Grid Method for the purpose of validation and verification of the model in rectangular and trapezoidal channel with partly dry side. The application results of the model were displayed reasonable flow distribution.

  • PDF

Comparison of the Existing Wet Etching and the Dry Etching with the ICP Process Method (새로운 ICP 장치를 이용한 고온 초전도체의 Dry Etching과 기존의 Wet Etching 기술과의 비교)

  • 강형곤;임성훈;임연호;한윤봉;황종선;한병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.2
    • /
    • pp.158-162
    • /
    • 2001
  • In this report, a new process for patterning of YBaCuO thin films, ICP(inductively coupled plasma) method, is described by comparing with existing wet etching method. Two 100㎛ wide and 2mm long YBaCuO striplines on LaAlO$_3$ substrates have been fabricated using two patterning techniques. And the properties were compared with the critical temperature and the SEM photography. Then, the critical temperatures of two samples were about 88 K, but the cross section of sample using ICP method was shaper than that using the wet etching method. ICP method can be used as a good etching technique process for patterning of YBaCuO superconductor.

  • PDF

STUDY ON THE DEVELOPMENT OF A TECHNIQUE FOR PRESERVING STRAW UNDER WET CONDITION IN BANGLADESH

  • Chowdhury, S.A.;Huque, K.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.9 no.1
    • /
    • pp.91-99
    • /
    • 1996
  • About 7.7 million tons of straw dry matter are being rotten during the monsoon. The objective of this trial was to develop a technique to preserve straw under wet condition. To simulate the moisture content of wet straw, a dry straw was deeped overnight in water. After draining the excess water, the wet straw(668 g moisture $kg^{-1}$) was divided into twenty fractions and preserved with 0, 30, 50 ro 70 g urea $kg^{-1}$ dry matter for either of 30, 60, 90, 120 or 180 days in sealed plastic container. Considering the colour, smell, fungal infestation and pH, the wert straw was preserved excellently up to 180 days when 50 or 70 g of urea per kg DM was used. Urea preservation increased the crude protein contents of straw by 3.6 to 6.4 times (174 to $364g{\cdot}kg^{-1}$) over that of the dry straw ($48g{\cdot}kg^{-1}$). Although the NDF content of straw was not effected by the level of urea or by the length of the preservation period, but the ADF content increased (p > 0.05) by 0.086 to $0.889g{\cdot}kg^{-1}$ straw DM for each g increase in the urea level. At 48 hours, the DM degradability of dry straw was $350g{\cdot}kg^{-1}$, which increased to $633g{\cdot}kg^{-1}$ when preserved with 50 g urea $kg^{-1}$ for 180 days. For the same straw, both the rate(0.0388 vs. 0.0136 fraction $h^{-1}$), the extent(717 vs. $631g{\cdot}kg^{-1}$) of straw degradation and the estimated ME(9.55 vs. $6.51MJ{\cdot}kg^{-1}$ straw DM) were higher in the preserved than the dry straw.

Corrosion Behavior of Zn and Zn-AI Alloy Coated Steels under Cyclic Wet-dry Environments

  • Nishikata, Atsushi;Yadav, Amar Prasad;Tsutsumi, Yusuke;Tsuru, Tooru
    • Corrosion Science and Technology
    • /
    • v.2 no.4
    • /
    • pp.165-170
    • /
    • 2003
  • Atmospheric corrosion behaviors of Zn, Zn-5%Al and Zn-55%A l coated steels have been investigated under cyclic wet-dry environments containing chloride ions. The wet-dry cycle was carried out by alternate exposure to immersion in 0.5 M (or 0.05 M) NaCl solutions and drying at $25^{\circ}C$ and 60 %RH. The polarization resistance $R_p$ and solution resistance $R_s$ were monitored by AC impedance technique. From the obtained $1/R_p$ and $1/R_s$ values, the corrosion rate of the coatings and the Time of Wetness (TOW) were estimated, respectively. Effects of chloride ions and TOW on the corrosion rates of Zn, Zn-5%Al, Zn-55%Al coatings and appearance of red rust (onset of underlying steel corrosion) under wet-dry cycles are discussed on the basis of the corrosion monitoring data.

Monitoring of Initial Stages of Atmospheric Zinc Corrosion in Simulated Acid Rain Solution under Wet-dry Cyclic Conditions

  • EL-Mahdy, Gamal A.;Kim, Kwang B.
    • Corrosion Science and Technology
    • /
    • v.3 no.6
    • /
    • pp.251-256
    • /
    • 2004
  • Exposure of zinc samples in simulated acid rain solution (SARS) was investigated under a periodic wet-dry conditions using an AC impedance technique. The periodic wet and dry exposure consisted of the immersion of zinc samples in SARS for one hour followed by exposure to 7 hours drying at 60% RH. Phases of the corrosion products were indentified by X-ray diffraction (XRD). The influence of relative humdiity (RH), temperature, and surface inclination on the atmospheric corrosion of zinc is described. The reciprocal of polarization resistance (1/Rp) decreases rapidly during the initial stages then slowly and eventually attains a steady state as exposure time progresses. The average of reciprocal of polarization resistance per cycle, (ARPR) was calculated and found to decrease as number of exposure cycle increases. An increase of temperature enhances the corrsion rate of zinc. The values of ARPR, of a sample inclined at 30 o are lower than those for a sample oriented horizontally. The experiment result shows a pronounced dependence of reciprocal of polarization resistance on RH. Exposure in the presence of carbonate anions gives rise to more protective corrosion products than in nitrate anion solution. The corrosion mechanism during the initial stages of atmospheric zinc corrosion under wet-dry cyclic conditions is suggested.

The effect of implant drilling speed on the composition of particle collected during site preparation

  • Jeong, Chang-Hee;Kim, Do-Young;Shin, Seung-Yun;Hong, Jong-Rak;Kye, Seung-Beom;Yang, Seung-Min
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.sup2
    • /
    • pp.253-259
    • /
    • 2009
  • Purpose: This study was aimed to evaluate the effect of implant drilling speed on the composition of particle size of collected bone debris. Methods: $Br{\aa}nemark$ $System^{(R)}$ drills were used to collect bone debris from 10 drilling holes (1 unit) at 1,500 rpm (Group A) and 800 rpm (Group B) in bovine mandible. After separating particles by size into > 500 ${\mu}m$, between 250 ${\mu}m$ and 500 ${\mu}m$, and < 250 ${\mu}m$ fractions, particle wet volume, dry volume, and weight were measured and the proportion of 3 fractions of bone debris to total wet volume, dry volume and weight was calculated as wet volume % , dry volume % and weight %. Results: No significant differences were found between Group A and B in wet volume, dry volume, and weight. However, of >500 ${\mu}m$ fractions, Group B had significantly higher wet volume %(P = 0.0059) and dry volume %(P = 0.0272) than in Group A. Conclusions: The drilling speed influenced the composition of particle size in collected drilling bone debris. The drilling in 800 rpm produced the more percentage of large particles than in 1,500 rpm. However, the drilling speed didn't effect on total volume of and weight of bone debris.

[ $(Th,U)O_2$ ] Pellets: Fabrication and Thermal Properties

  • Kang Ki Won;Yang Jae Ho;Kim Keon Sik;Song Kun Woo;Lee Chan Bock;Jung Youn Ho
    • Nuclear Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.299-308
    • /
    • 2003
  • Fabrication technique of $(Th,U)O_2$ pellets has been investigated. Powder mixtures of $ThO_2\;and\;UO_2$ were milled in two different ways-dry and wet milling. Milled powder was compacted and sintered to $(Th,U)O_2$ pellets. The wet-milled powder leads to a $(Th,U)O_2$ pellet having a high sintered density and uniform distribution of U and Th, compared to the dry-milled powder. The sintered density of a $(Th,U)O_2$ pellet tends to decrease by increasing the content of $ThO_2$. The thermal conductivity of $ThO_2\;and\;(Th,U)O_2$ pellets was measured by the laser flash method. The thermal conductivity of the $ThO_2$ pellet is higher than that of the $UO_2$ pellet, and the thermal conductivities of $(Th,U)O_2$ pellets containing $65wt\%\;and\;35wt\%\;ThO_2$ pellets are lower than that of the $UO_2$ pellet.

Inactivation of Indoor Airborne Fungi Using Cold Atmospheric Pressure Plasma (저온 대기압 플라즈마의 실내공기 중 곰팡이 생장억제 효과)

  • Paik, Namwon;Heo, Sungmin;Lee, Ilyoung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.351-357
    • /
    • 2019
  • Objectives: The objectives of this study were to investigate fungal contamination in a 31-year old university building in Seoul, Korea, and to study the inactivation of fungi using cold atmospheric pressure plasma(CAP). Methods: To investigate the fungal contamination in a university building, air samples were collected from five locations in the building, including two study rooms, a storage room, a laboratory, and a basement. The sampling was performed in a dry season(February to April) and in a wet season(July). To study the inactivation efficacy of fungi by CAP, airborne fungal concentrations were measured before and after the operation of the CAP generator. Results: Humidity was an important factor affecting fungal growth. The airborne fungal concentrations determined in the wet season(July) were significantly higher than those determined in the dry season(February to April). In the basement, the values determined in the dry and wet season were 319 and $3,403CFU/m^3$, respectively. The inactivation efficiency of fungi by CAP was 83-90% over five to nine days of operation. Conclusions: The university building was highly contaminated by airborne fungi, especially in summer. It is concluded that humidity is an important factor affecting fungal growth and CAP is a highly useful technique for inactivation of indoor airborne fungi.

Monitoring of Corrosion Rates of Carbon Steel in Mortar under a Wet-Dry Cyclic Condition

  • Kim, Je-Kyoung;Kang, Tae-Young;Moon, Kyung-Man
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.3
    • /
    • pp.179-183
    • /
    • 2007
  • The corrosion behavior of metal covered with mortar under a wet-dry cyclic condition were investigated to apply for the measurement of corrosion rates of reinforcing steel in concrete structure. The carbon steel in mortar having t=3 mm cover thickness was exposed to the alternate condition of 6 h immersion in chloride containing solution and 18 h drying at $25^{\circ}C$ and 50%RH. The electrochemical phenomena of a carbon steel and mortar interface was explained by an equivalent circuit consisting of a solution resistance, a charge transfer resistance and a CPE(Constant Phase Element). The corrosion rates were monitored continuously during exposure using an AC impedance technique. Simultaneously, the current distribution over the working electrode during impedance measurement was analyzed from the phase shift, $\theta$, in an intermediate frequency. The result showed that corrosion rate monitoring using an AC impedance method is suitable under the given exposure conditions even during the drying period when the metal is covered with the wetted mortar.

Performance Test for a Horizontal Regenerative Evaporative Cooler (수평형 재생증발식 냉방기의 성능시험)

  • Song, Gwi-Eun;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF