• 제목/요약/키워드: Wet Environment

검색결과 724건 처리시간 0.021초

국내 수질측정대행업에 대한 생태독성 숙련도시험 평가 (Evaluation of Whole Effluent Toxicity (WET) Proficiency Testing for Water Quality Measurement Agencies in Korea)

  • 박우상;김상훈
    • 한국물환경학회지
    • /
    • 제29권4호
    • /
    • pp.568-573
    • /
    • 2013
  • In this study, we conducted whole effluent toxicity (WET) proficiency testing based on the results which $EC_{50}$ value of 3 types (A, B, C) unknown samples calculated from 32 water quality measurement agencies in Korea. WET proficiency testing was expected to their improve of analysis skill and ensure reliability of analysis results. Ultimately, it is intended to promote the reliable enforcement of WET. WET proficiency testing was evaluated using the z-score, robust z-score and the results showed that 30 participating agencies were "compliance". In addition, $EC_{50}$ values of "unknown sample A" were the normal distribution. Therefore, "unknown sample A" was considered as the most suitable standard toxicity substance.

NPS-WET 모형을 이용한 인공습지의 수질정화효과 분석 (Analysis of Water-quality Improvement Efficiency of Constructed Wetland Using NPS-WET Model)

  • 이한필;정광욱;이복수;함종화;손영권
    • 한국물환경학회지
    • /
    • 제28권2호
    • /
    • pp.320-331
    • /
    • 2012
  • A combination system of catch canal and constructed wetland was designed and suggested to improve water quality in gagricultural region of lower Dong-jin river basin. In order to evaluate an water quality improvement efficiency of the designed combination system, the NPS-WET model was applied in this study. Simulation result of the NPS-WET shown that the nutrient load removal rate of constructed wetland was BOD, T-N, T-P and SS was 30.7~39.0%, 46~60%, 40.7~57.0% and 68.2~74.7%, respectively. Nutrients reduction of constructed wetland was higher in growing season than winter season because vital activity of microorganism, macrophyte and algae was augmented with high air and water temperature. Effluents from constructed wetland can affect water-quality of catch canal drains, especially, water-quality on junction point to Dong-jin river. Water-quality improvement in low-flowed catch canal (Un-san) was more significant than in high-flowed catch canal (Won-pyeong). In conclusion, a feasible design of constructed wetland is necessary to treat large quantity of receiving water. The NPS-WET is useful tool for assessing water-quality improvement efficiency using constructed wetland.

Comparison of Heavy Metal Concentration and Reproduction of Feral Pigeons (Columba livia) between Urban and Industrial Complex Areas from Korea

  • Nam, Dong-Ha;Lee, Doo-Pyo;Koo, Tae-Hoe
    • The Korean Journal of Ecology
    • /
    • 제25권6호
    • /
    • pp.383-389
    • /
    • 2002
  • Pb and Cd concentrations and reproductive progress of feral pigeons were investigated in urban (Seoul) and industrial complex (Ansan) areas from November 2000 to May 2001. Results of the Pb analysis for the feral pigeons from the Ansan industrial complex (egg contents: 1.13 $\mu$g/wet g, bones of adult: 10.5 $\mu$g/wet g) and Seoul (1.64 $\mu$g/wet g, 29.5 $\mu$g/wet g, respectively) indicated that the Pb level of eggs and bones of adults were significantly different between the two colonies (p<0.05). Cd concentrations in liver and kidney of adult pigeons were also significantly different between the Ansan (liver: 0.14 $\mu\textrm{g}$/wet g, kidney: 0.43 $\mu$g/wet g) and Seoul (liver. 0.24 $\mu$g/wet g, kidney: 1.05 $\mu$g/wet g) colonies. (p<0.05). However, egg size and thickness, incubation period and nestling growth rates did not differ between the study areas. Also, clutch size, number of young hatched per nest and number of young fledglings per nest did not significantly different in the noted areas. Considering the lead and cadmium concentrations of pigeons, these were not as high as those considered as results in toxic effects in other species, and the biological significance from these level differences is uncertain.

How do the work environment and work safety differ between the dry and wet kitchen foodservice facilities?

  • Chang, Hye-Ja;Kim, Jeong-Won;Ju, Se-Young;Go, Eun-Sun
    • Nutrition Research and Practice
    • /
    • 제6권4호
    • /
    • pp.366-374
    • /
    • 2012
  • In order to create a worker-friendly environment for institutional foodservice, facilities operating with a dry kitchen system have been recommended. This study was designed to compare the work safety and work environment of foodservice between wet and dry kitchen systems. Data were obtained using questionnaires with a target group of 303 staff at 57 foodservice operations. Dry kitchen facilities were constructed after 2006, which had a higher construction cost and more finishing floors with anti-slip tiles, and in which employees more wore non-slip footwear than wet kitchen (76.7%). The kitchen temperature and muscular pain were the most frequently reported employees' discomfort factors in the two systems, and, in the wet kitchen, "noise of kitchen" was also frequently reported as a discomfort. Dietitian and employees rated the less slippery and slip related incidents in dry kitchens than those of wet kitchen. Fryer area, ware-washing area, and plate waste table were the slippery areas and the causes were different between the functional areas. The risk for current leakage was rated significantly higher in wet kitchens by dietitians. In addition, the ware-washing area was found to be where employees felt the highest risk of electrical shock. Muscular pain (72.2%), arthritis (39.1%), hard-of-hearing (46.6%) and psychological stress (47.0%) were experienced by employees more than once a month, particularly in the wet kitchen. In conclusion, the dry kitchen system was found to be more efficient for food and work safety because of its superior design and well managed practices.

연안환경 괭이갈매기(Larus crassirostris) 알의 DDTs 및 수은 농도분포 조사 (Distribution of DDTs and Hg in Eggs of Black-Tailed Gulls (Larus crassirostris) in the Coastal Environment)

  • 최정희;정다위;이종천
    • 한국환경과학회지
    • /
    • 제27권12호
    • /
    • pp.1279-1290
    • /
    • 2018
  • Sea gulls are high trophic level consumers in the coastal environment, and thus, which have been widely used to monitor contamination biomagnified through a food web. However, such monitoring studies using sea gulls have been rare in the Korean literature. The National Environmental Specimen Bank chose eggs of a black-tailed gulls (Larus crassirostris) to serve as an environmental specimen for the long-term monitoring of the coastal ecosystem affected by terrestrial pollutants. Black-tailed gull eggs were collected from Baengnyeongdo, Hongdo and Uleungdo, and their DDTs and total mercury content were determined. The highest concentration of ${\Sigma}DDTs$ was $231.6{\pm}106.1{\mu}g/kg$ wet in Baengnyeongdo, followed by $230.0{\pm}123.8{\mu}g/kg$ wet in Ulleungdo, and $117.7{\pm}18.3{\mu}g/kg$ wet in Hongdo. In addition, total mercury was detected at $414.5{\pm}97.6{\mu}g/kg$ wet in Ulleungdo, $363.9{\pm}123.6{\mu}g/kg$ wet in Hongdo, and $237.5{\pm}42.3{\mu}g/kg$ wet in Baengnyeongdo. Relatively high concentrations of the target pollutants were recorded in specimens from Ulleungdo. Additional comprehensive and prolonged studies are required to elucidate spatial and temporal patterns of contamination in black-tailed gull eggs with regard to monitoring contaminant trends in eggs and prey.

연안역의 환경과 미티게이션 기술 (Water Environment and Mitigation Technique of Coastal Zone)

  • 최영박
    • 기술사
    • /
    • 제33권1호
    • /
    • pp.51-60
    • /
    • 2000
  • The mitigation technique is to minimize influences to the environments, and it is one of the environmental management(or administration) to techniques. Its objective is to create sustainable environment by keeping human assistance to the environment as minimal as possible. It restores, creates, enhances, and most importantly preserves the environment by avoiding, minizing, rectifying, eliminating, and compensating the natural circumstances The evaluation of adverse effects to the environment and their reduction is as follow: HEP(Habitat Evaluation Procedure) WET(Wet land evaluation technique) HGM(Hydro Geomorphic Assessment) BEST(Biological Evaluation Standardized Technique) Since there are both pro and cons in the American and Japanese mitigation methods, it is hard to choose which one is better.

  • PDF

정전분무 방전극을 이용한 습식 전기집진장치의 미세먼지 집진효율 평가 (Evaluation of Particle Collection Efficiency in a Wet Electrostatic Precipitator Using an Electrosprayed Discharge Electrode)

  • 김홍직;김종현;김종호
    • 한국대기환경학회지
    • /
    • 제31권6호
    • /
    • pp.530-537
    • /
    • 2015
  • The wet electrostatic precipitator (wet ESP) is an effective control device which removes submicron particles reentrained in a collection plate and water soluble gas. However, its collection efficiency decreases, as its operation is subject to water-induced distortion of the collection electrode. In order to make up for the limitation, we modified the wet ESP system by installing electrosprayed discharge electrodes. The modified wet ESP system can wash both the collection plate and discharge electrode. As a result, we were able to fabricate a compact wet ESP with a small specific collecting area ($0.18m^2(m^3/min)$) that can accomplish a high collection efficiency of fine particles (97.1%). In addition, the device obtained a relatively low specific corona power of approximately $10W/(m^3/min)$.

Performance evaluation of nitrate removal in high TDS wet scrubber wastewater by ion exchange resin with dissolved air flotation (DAF) process

  • Kim, Bongchul;Yeo, Inseol;Park, Chan-gyu
    • Membrane and Water Treatment
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2022
  • The regulations of the International Maritime Organization (IMO) have been steadily strengthened in ship emissions. Accordingly, there is a growing need for development of related technologies for the removal of contaminants that may occur during the treatment of SOx and NOx using a wet scrubber. However, this system also leads to wastewater production when the exhaust gas is scrubbed. In this research, we evaluated the performance of an ion selective resin process in accordance with scrubber wastewater discharge regulations, specifically nitrate discharge, by the IMO. Accelerated real and synthetic wastewater of wet scrubbers, contained high amounts of TDS with high nitrate, is used as feed water in lab scale systems. Furthermore, a pilot scale dissolved air flotation (DAF) using microbubble generator with ion exchange resin process was combined and developed in order to apply for the treatment of wet scrubber wastewater. The results of the present study revealed that operating conditions, such as resin property, bed volume (BV), and inlet wastewater flow rate, significantly affect the removal performance. Finally, through a pilot test, DAF with ion exchange resin process showed a noticeable improvement of the nitrate removal rate compared to the single DAF process.

고온용 Circuit-analog 전파흡수구조의 350℃ 및 열 수분 환경에서의 적용성 평가 (Evaluation of Applicability of Circuit-analog Radar Absorbing Structures for High Temperature in 350℃ and Hot-wet Environment)

  • 장민수;김호범;홍헌석
    • Composites Research
    • /
    • 제36권5호
    • /
    • pp.335-341
    • /
    • 2023
  • 본 연구에서는 고온용 Circuit-analog 전파흡수구조(CA-RAS)를 제안하고, 350℃ 및 열 수분 환경에서의 전파흡수성능 및 인장 물성을 평가하였다. Glass/cyanate ester와 사각형 저항 패턴층을 통해 CA-RAS를 구현하였으며, 자유공간 측정장비를 이용하여 350℃ 환경과 열 수분 환경 노출 후의 반사손실을 측정했다. 또한 ASTM D638 규격에 따라 환경 노출 후의 인장강도를 측정했다. 제안된 CA-RAS는 350℃까지 4 GHz 이상의 -10 dB 흡수 대역과 -20 dB 이상의 피크 값을 보였으며, 열 수분 환경 노출 후에도 전파 흡수 성능의 저하가 확인되지 않았다. 또한 환경 노출 후에도 Glass/cyanate ester의 상온 인장강도 대비 95% 이상의 인장강도 값이 확인되었다. 이를 통해 본 연구에서는 제안된 전파흡수구조의 고온 및 열 수분 환경에 노출되는 저피탐 구조물로서의 적용 가능성을 확인하였다.

대기 중 수은의 습식 침적 평가: 소양호를 중심으로 (Estimation of Atmospheric Mercury Wet-deposition to Lake So-yang)

  • 안명찬;한영지
    • 한국대기환경학회지
    • /
    • 제24권6호
    • /
    • pp.693-703
    • /
    • 2008
  • The important source of the mercury in water-column is the influx of atmosphere mercury, via dry and wet deposition. In this study, wet deposition of mercury was estimated to be $14.56{\mu}g/m^2$ during 15 months at the Lake Soyang, which is a little higher than those observed in the several rural US Mercury Deposition Network (MDN) sites with similar precipitation depth. The mercury concentration in precipitation did not show a positive correlation with atmospheric RGM (reactive gaseous mercury) concentration, while maintaining good correlation with atmospheric $PM_{2.5}$ at Soyang Dam. This result suggests that the contribution of particulate Hg to the total Hg wet deposition should be more significant than that of RGM. In this study, both precipitation depth and precipitation type affected the amount of wet deposition and the concurrent mercury levels in precipitation. There was generally an inverse relationship between precipitation depth and Hg concentration in precipitation. Precipitation type was another factor that exerted controls on the Hg concentration in precipitation. As a result, the highest concentration of Hg was observed in snow, followed by in mixture (snow+rain) and in rain.