A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources (고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰)

  • Baek, Tae-Seong;Lee, Seung-Wook;Na, Soo-Kyong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose: To compare of the accuracy among various measurement procedures of HDR Brachytherapy, and to evaluate the clinical suitability and usefulness of alternative PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom without any additional cost due to the purchase of measuring apparatus. Materials and Methods: We made a comparative study on three types of measuring systems: well type chamber, source calibration jig, and PMMA plate phantom. Farmer type chamber was used for source calibration jig method and PMMA plate phantom method. Measurement was done 5 times each in comparison with the measurement values from manufacturer. Measurement results from experiment were compared with that from the manufacturer which is offered with the source whenever a source is substituted by a new one and evaluate the accuracy of source activity. Results: As a consequence of Ir-192 source measurement using well type chamber, source calibration jig and PMMA plate phantom, RMS (Root Mean Square) values for the relative error are 0.6%, 1.57%, 2.1%, respectively, compared with the data from manufacturer. And the mean errors with standard deviation are given $-0.2{\pm}0.5%$, $0.97{\pm}1.23%$, $-0.89{\pm}1.87%$ respectively. Conclusion: From the results shown by the three types of measurement system (well type chamber, source calibration jig, and PMMA plate phantom), the measurement with well type chamber produced the best accuracy. It turns out that we can also use the alternative system of PMMA plate phantom clinically without purchasing any additional particular apparatus since the system does not exceed the recommendation of AAPM (American Association of Physicists in Medicine), which requires the error range of within ${\pm}5%$.

  • PDF

Evaluation of Exposure to Indoor Volatile Organic Compounds by Utilizing Emission Characteristics and Emission Factor of Household Mosquito Repellents (가정용 모기살충제의 배출 특성 및 배출계수를 이용한 실내 휘발성 유기화합물질 노출 평가)

  • Jo, Wan-Kuen;Lee, Jong-Hyo
    • Journal of Environmental Science International
    • /
    • v.18 no.10
    • /
    • pp.1123-1134
    • /
    • 2009
  • This study was designed to evaluate qualitatively and quantitatively the pollutant compositions, which were emitted from three types of mosquito repellents(MRs)(mat-, liquid-vaporized, and coil-type) by utilizing a 50-L environmental chamber. A qualitative analysis revealed that 42 compounds were detected on the gas chromatography/mass spectrometer system, and that the detection frequency depended upon chemical types. Nine of the 42 compounds exhibited a detection frequency of 100%. Four aromatic compounds(benzene, ethyl benzene, toluene, and xylene) were detected in all test MRs. The concentration equilibriums in the environmental chamber were achieved within 180 min after sample introduction. The coil-type MR represented higher chamber concentrations as compared with the mat- or liquid-vaporized-type MR, with respect to the target compounds except for naphthalene. In particular, the chamber concentrations of ethyl benzene, associated with the use of coil-type MR, were between 0.9 and $65\;mg\;m^{-3}$ whereas those of mat- and liquid-vaporized-type MRs we~e between 0.5 and $2.0\;mg\;m^{-3}$and 0.3 and $1.4\;mg\;m^{-3}$, respectively. However, naphthalene concentrations in the chamber, where a liquid-vaporized-type MR was placed, were measured as between 17.8 and $56.3\;mg\;m^{-3}$, but not detected in the chamber, where a mat- or coil-type MR was placed. The empirical model fitted well with the time-series concentrations in the environmental chamber(in most cases, determination coefficient, $R^2$ ≿ 0.9), thereby suggesting that the model was suitable for testing emissions. In regards to the target compounds except for benzene, although they were emitted from the MRs, health risk from individual exposure to them were estimated not to be significant when comparing exposure levels with no observed adverse exposure levels or lowest observed adverse exposure levels of corresponding compounds. However, it was concluded that the use of MRs could be an important indoor source as regards benzene.

Analysis of Accuracy of Apparent Activity According to Calibration Method for High Dose Rate Brachytherapy Source (측정용 전리함에 따른 고 선량율 근접치료용 방사성 선원의 겉보기 활성도의 정확도 비교 분석)

  • Huh, Hyun-Do;Choi, Jin-Ho;Choi, Sang-Hyoun;Kim, Seong-Hoon;Kim, Woo-Chul;Kim, Hun-Jeong;Lee, Re-Na;Kim, Kum-Bae;Hong, Seong-Eon;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.305-312
    • /
    • 2008
  • The aim of this study is to introduce the accuracy of Ir-192 source's apparent activity using the well-type chamber and the Farmer-type ionization chamber in the high dose rate brachytherapy. We measured the apparent activity of Ir-192 that each medical center in the country has and the apparent activity of calibration certificate provided by manufacturer is compared with that by our experimental measurement. The number of sources used for the activity comparison was 5. The accuracy of the measured activity was in the range of -2.8% to -1.0% and -2.1% to 0.2% for the Farmer-type chamber system (Jig) and for the well-type, respectively. The maximum difference was within 1.0% for comparison with two calibration's tool. Our results demonstrate that well-type chamber as wall as Farmer-type chamber is a appropriate system as the routine source calibration procedures in HDR brachytherapy. Whenever a new source is installed to use in clinics, by periods, a source calibration should be carried out.

  • PDF

Comparison of Calibration Methods of $^{192}\textrm{Ir}$ Sources for High Dose Rate Brachytherapy (고선량률 근접조사치료용 이리듐-192 방사성동위원소의 교정방법 비교연구)

  • Huh Hyun Do;Park Sung Yong;Lee Rena J;Shin Dong Oh;Kwon Soo Il;Loh John J K;Choi Jinho
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.192-196
    • /
    • 2004
  • The activity of Ir-192 sources for high dose rate (HDR) Brachytherapy in Korea were measured by using the well-type chamber and using the calibration Jig with the Farmer-type ionization chamber to compare the manufacturer certificated source strength which is supplied with each new Ir-192 source. The activity of two different source models used in six hospitals were measured. The range of measured activities to the manufacturer's suggested ones was -2.40% to +3.31% for the calibration Jig and -3.12% to 0.00% for the well-type chamber system. The source strength values given by the manufacturer for the 6 sources were within ${\pm}5%$ for the two different measuring equipment. Our results demonstrate that well-type chamber as wall as Farmer-type chamber system are appropriate system for the routine source calibration procedures in HDR brachytherapy. Whenever a new source is installed to use in clinics, a source calibration should be carried out.

  • PDF

The Activity Check of Brachytherapy Isotope (근접치료동위원소의 Activity Check)

  • Kim, Gun-Oh;Lee, Byung-Koo;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.21-27
    • /
    • 2004
  • An isotope Ir-192, which is used in brachytherapy depends on import in whole quantities. There are a few ways for its activity. measurement using Welltype chamber or the way to rely on authentic decay table of manufacturer. In-air dosimetry using Farmer Chamber, etc. In this paper, let me introduce the way using Farmer chamber which is easier and simple. With the Farmer chamber and source calibration jig, take a measurement the activity of an isotope Ir-192 and compare the value with the value from decay table of manufacturer and check the activity of source. The result of measurement, compared the value from decay table, by ${\pm}2.1\%$. (which belongs to recommendable value for AAPM ${\pm}5\%$ as difference of error range) It is possible to use on clinical medicine. With the increase in use of brachytherapy, the increase of import is essential. And an accurate activity check of source is compulsory. For the activity check of source, it was possible to use Farmer chamber and source calibration jig without additional purchase of Well type chamber.

  • PDF

Hydroelastic Analysis of Pontoon Type VLFS Considering the Location and Shape of OWC Chamber (공기챔버 위치에 따른 폰툰형 초대형 구조물 유탄성응답 해석)

  • Hong, Sa-Young;Kyoung, Jo-Hyun;Kim, Byoung-Wan
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.22-29
    • /
    • 2008
  • A numerical investigation is made on the effects of the location and shape of the front wall of an OWC(Oscillating Water Column) chamber on the hydroelastic response of a VLFS. Most of the studies on the effects of an OWC chamber on the response of a VLFS have assumed the location of the OWC chamber to be at the front of the VLFS. In the present study, an OWC-chamber is introduced at an arbitrary position in relation to a VLFS to determine the influence of the location and shape of the OWC chamber on the hydroelastic response of the VLFS. A finite element method is adopted as a numerical scheme for the fluid domain. or the finite element method, combined with a mode superposition method, is applied in order to consider the change of mass and stiffness The OWC chamber in a piecewise constant manner. or the facilitated anefficient analysis of The hydroelastic response of the VLFS, as well as the easy modeling of different shape and material properties for the structure. Reduction of hydroelastic response of the VLFS is investigated for various locations and front wall shapes of the owe chamber.

Implantation of dual chamber pacemaker: report of 2 cases (생리적 심박동조절이 가능한 Dual Chamber Pacemaker이식 치험 2)

  • 김은기
    • Journal of Chest Surgery
    • /
    • v.16 no.4
    • /
    • pp.547-554
    • /
    • 1983
  • Implantation of Dual Chamber Pacemakers Which sense in the Atrium and the Ventricle, and sequentially or synchronously trigger impulses in the both chambers, has led us to the near realization of the ideal "Physiologic Pacing". We have experienced two cases of implantation of Dual chamber pacemaker in September and October, 1983. One patient was a 21-year-old male who had postoperative complete heart block since he was taken Total correction of TOF in May, 1983 . We implanted transvenously a dual chamber pacemaker, VDD type, through the left subclavian vein. In the other patient who came to the emergency room for partial obstruction of small bowels with severe abdominal pain, nausea and vomiting, in whom heart block was found, we implanted a DDD type pacemaker through the left subclavian puncture. The pacemakers have been functioning well postoperatively for more than two months, and the conditions of patient were uneventful.

  • PDF

Comparative Measurement of Radioactivity with Standard Gamma-ray Ionization Chamber System (표준 감마선 전리함 장치에 의한 방사능 비교 측정)

  • Park, Tae-Soon;Woo, Dong-Ho;Oh, Pil-Jae;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.1
    • /
    • pp.11-18
    • /
    • 1984
  • A Standard gamma-ray ionization chamber system was developed with a well type ionization chamber and micro current measuring circuit. Micro current was measured by the automatic Townsend balance with stepwise compensation method. For gamma emitting nuclides such as $^{241}Am,\;^{133}Ba,\;^{60}Co,\;^{134}Cs,\;^{137}Cs,\;and\;^{22}Na$ relative calibration factors to $^{226}Ra$ reference source were calculated and detection .efficiency curve was determined as a fudnction of gamma energy.

  • PDF

Evaluation of KICT-type Large Penetration Test using Calibration Chamber System (Calibration Chamber System을 이용한 KICT-type LPT 장비의 거동분석)

  • Kim, Young-Seok;Kim, Young-Chin;Lee, Woo-Jin;An, Shin-Whan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1359-1364
    • /
    • 2008
  • It is well known that the standard penetration test (SPT) has been used in all over the world to get geotechnical properties of the ground. However, it is difficult to apply the SPT to the dense sand, gravel, weathered rock, etc. For the application of the SPT in these grounds, it is necessary to change in the diameter and the impact energy of the SPT. For the improvement of site investigation technology, Large Penetration Testing device (KICT-type LPT) was developed and applied to the in situ condition. The drop height and weight of the hammer in developed system were decided as 760mm and 150kg, respectively. And the developed sampler has the inner diameter of 63 mm and the length of 500 mm with the adjustment of energy ratio to the SPT of 1.5. In this study, the performance of KICT-type LPT was evaluated by using a calibration chamber system and pile driving analyzer (PDA)

  • PDF

Characteristics of Particle Separation in Suspension using an Ultrasonic Standing Wave

  • Shin, Beom-Soo;Danao, Mary-Grace C.
    • Journal of Biosystems Engineering
    • /
    • v.37 no.2
    • /
    • pp.113-121
    • /
    • 2012
  • Purpose: Particle separation in solution is one of important process in a unit operation as well as in an extract preparation for biosensors. Contrary to centrifuge-type of mesh-type filter, using an ultrasonic standing wave make the filtering process continuous and free from maintenance. It is needed to investigate the characteristics of particle movement in the ultrasonic standing wave field. Methods: Through the computer simulation the effects of major design and driving parameters on the alignment characteristics of particles were investigated, and a cylindrical chamber with up-stream flow type was devised using two circular-shape PZTs on both sides of the chamber, one for transmitting ultrasonic wave and the other for just reflecting it. Then, the system performance was experimentally investigated as well. Results: The speed of a particle to reach pressure-node plane increased as the acoustic pressure and size of particle increased. The maximum allowable up-stream flow rate could be calculated as well. As expected, exact numbers of pressure-node planes were well formed at specific locations according to the wavelength of ultrasonic wave. As the driving frequency of PZT got close to its resonance frequency, the bands of particles were observed clearer, which meant the particles were trapped into narrower space. Higher excitation voltages to the PZT produced a greater acoustic force with which to trap particles in the pressure-node planes, so that the particles gathered could move upwards without disturbing their alignments even at a higher inlet flow rate. Conclusions: This research showed the feasibility of particle separation in solution in the continuous way by an ultrasonic standing wave. Further study is needed to develop a device to collect or harvest those separated particles.