• Title/Summary/Keyword: Weightlifting

Search Result 14, Processing Time 0.02 seconds

The Forecasting a Maximum Barbell Weight of Snatch Technique in Weightlifting (역도 인상동작 성공 시 최대 바벨무게 예측)

  • Hah, Chong-Ku;Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.143-152
    • /
    • 2005
  • The purpose of this study was to predict the failure or success of the Snatch-lifting trial as a consequence of the stand-up phase simulated in Kane's equation of motion that was effective for the dynamic analysis of multi-segment. This experiment was a case study in which one male athlete (age: 23yrs, height: 154.4cm, weight: 64.5kg) from K University was selected The system of a simulation included a multi-segment system that had one degree of freedom and one generalized coordinate for the shank segment angle. The reference frame was fixed by the Nonlinear Trans formation (NLT) method in order to set up a fixed Cartesian coordinate system in space. A weightlifter lifted a 90kg-barbell that was 75% of subject's maximum lifting capability (120kg). For this study, six cameras (Qualisys Proreflex MCU240s) and two force-plates (Kistler 9286AAs) were used for collecting data. The motion tracks of 11 land markers were attached on the major joints of the body and barbell. The sampling rates of cameras and force-plates were set up 100Hz and 1000Hz, respectively. Data were processed via the Qualisys Track manager (QTM) software. Landmark positions and force-plate amplitudes were simultaneously integrated by Qualisys system The coordinate data were filtered using a fourth-order Butterworth low pass filtering with an estimated optimum cut-off frequency of 9Hz calculated with Andrew & Yu's formula. The input data of the model were derived from experimental data processed in Matlab6.5 and the solution of a model made in Kane's method was solved in Matematica5.0. The conclusions were as follows; 1. The torque motor of the shank with 246Nm from this experiment could lift a maximum barbell weight (158.98kg) which was about 246 times as much as subject's body weight (64.5kg). 2. The torque motor with 166.5 Nm, simulated by angular displacement of the shank matched to the experimental result, could lift a maximum barbell weight (90kg) which was about 1.4 times as much as subject's body weight (64.5kg). 3. Comparing subject's maximum barbell weight (120kg) with a modeling maximum barbell weight (155.51kg) and with an experimental maximum barbell weight (90kg), the differences between these were about +35.7kg and -30kg. These results strongly suggest that if the maximum barbell weight is decided, coaches will be able to provide further knowledge and information to weightlifters for the performance improvement and then prevent injuries from training of weightlifters. It hopes to apply Kane's method to other sports skill as well as weightlifting to simulate its motion in the future study.

A Comparison Analysis of EMG according to Weight Class and Increase Record of Clean and Jerk Techniques Weightlifting in High School Female Weight Lifters (고교여자역도 선수들의 용상동작 수행 시 체급별 무게증가에 따른 EMG변화 비교 분석)

  • Park, Il-Bong;Yeo, Nam-Hwoeh;Kim, Jung-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.105-114
    • /
    • 2008
  • The purpose of this study was to compare of muscles in clean and jerk techniques between 69kg class(n=3), 58kg class(n=3) in high school female weight lifters using EMG(electromyographic) system. EMG analysis were executed on 6 major muscles and dividing clean and jerk techniques into 6 phases. In that result, in the difference by weight, it was shown that EMG value increased gradually as the weight is raised of all muscles group & phases in 58kg class. In EMG signal scale by classes, it was shown that EMG signal scale didn't increase according to class & weight. In the result of this study, that EMG value was inconsistent in 69kg class is showing that the consideration of the technical factor together with muscle power has positive affect more on the performance improvement in the heavy class.

Effect and Value of Custom-made Mouthguard in Athletic Performance (맞춤형 마우스가드의 효능과 실제)

  • Lee, sungbok Richard
    • The Journal of the Korean dental association
    • /
    • v.53 no.9
    • /
    • pp.602-609
    • /
    • 2015
  • The aim of this document is to evaluate the effect of bite balance on physical fitness and motor capacity to determine the importance of the occlusal stability as a possible action mechanism of occlusal appliance including mouthguards on physical performances. We all remember that day when the prominent athlete was in the news wearing a mouthguard to improve human athletic performance. I once had investigated the determinants of athletic performance in all sorts of sports. Most of the studies had overinterpretation of results and lack of evidence to support the information. However, I discovered great expectations for new possibility in this field and settled for a more academic approach to this intriguing subject. The followings are some examples of the subject 1. Archers who wore occlusal appliances to increase the vertical dimension of occlusion by 2~3mm increased their ability to focus and to maintain good sense of balance. Their accuracy rate has been improved. The appliance was made of acrylic resin (a type of plastic). 2. Canoe players who wore occlusal appliances to increase the vertical dimension of occlusion by 5mm surpassed longtime competitor and won the race with 10 seconds gap. 3. A cycle rider who wore an occlusal appliance to treat his malocclusion surpassed his old record from 10.8 seconds to 10.3 seconds. His muscle reflexes (anaerobic exercise) and endurance (aerobic exercise) has been enhanced. 4. Occlusal appliances had a good effect on athletic performance in most sports such as swimming, diving, and weightlifting. As for the clenching on dentition, people clench their teeth when they push their physical and mental limits during sports activities. Clenching can be induced by physical exertion when maximum muscle strength is retained and this is similarly found in different types of exercises. In addition, restraint of respiratory function is observed. Therefore, creating a occlusal balance with occlusal appliance or mouthguard promoted a favorable influence when an athlete clenches.

The availability for cardiorespiratory fitness measurement by 20 m shuttle run test in different sports type of elite athletes. Exercise Science (엘리트 선수들의 운동특성에 따른 20 m 셔틀런 검사의 유용성)

  • Kim, J.K.;Lee, N.J.;Lee, M.S.
    • Exercise Science
    • /
    • v.21 no.2
    • /
    • pp.183-190
    • /
    • 2012
  • This study is to evaluate the availability of cardiorespiratory fitness measurement by 20 m shuttle run test based upon energy contribution rates of elite athletes in different sports type. Sixty-seven elite athletes attending K national university participated in this study. They were divided by three groups based upon sports type, composed of Anaerobic Group (sprint, jumps, weightlifting, throw; n=35), Aerobic Group (medium-long distance; n=9), and Combat Sport Group (judo; n=23). 20 m shuttle run test was conducted by Leger et al.(1982) method and calculating acceleration using measured shuttle run repetitions was conducted by Brewer et al.(1988) method. To test the usefulness of VO2max, graded exercise treadmill test was conducted and standing long jump and 50 m run were measured as power fitness factors. Z-jump was used for measuring power, agility, and muscular endurance. Standing long jump and 50 m run of Anaerobic Group (AnG) was significantly higher than that of Aerobic Group (AeG) and Combat Sport Group (CG) (p<0.05). However, Z-jump of CG was significantly higher than that of AnG and AeG(p<.05). There was a higher correlation of 20 m shuttle run test and VO2max in AnG(r= 0.577, p<.0001) and CG(r= 0.760, p<.0001). Otherwise, there was a low correlation of 20 m shuttle run test and VO2max in AeG. There was no significant group difference to test the availability of 20 m shuttle run test and there was a reduced error when converting 20 m shuttle run results into VO2max. This study examined the usefulness of 20 m shuttle run test by converting 20 m shuttle run repetition results into VO2max calculation, which showed reduced error. Therefore, this study confirmed that it would be needed to convert 20 m shuttle run results into VO2max for universal and practical use in the field without dividing sports type.