• Title/Summary/Keyword: Weighted Difference Image

Search Result 98, Processing Time 0.026 seconds

An effectiveness of multitransmit parallel technique on scan time reduction in hip joint MRI (고관절 자기공명영상 검사 시 multitransmit 기법의 적용에 따른 검사시간 단축의 유용성)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.103-108
    • /
    • 2016
  • This study examined the effectiveness of the multitransmit parallel technique on the MRI scan time reduction by removing the dielectric effect. The T1 and T2 weighted images of the patients' hip joint were acquired with and without a multitransmit technique. The ROIs were located in the head of femur and iliopsoas muscle. The SNR, CNR and scan time were measured and compared. There was no difference in the images with and without multitransmit. In contrast, the acquisition time was decreased by 42.8% in T1WI and 49.7% in T2WI. In conclusion, this study demonstrated that significant scan time reductions can be accomplished without any differences in the image quality in hip joint MRI by applying the multitransmit parallel technique. Furthermore, the multitranstmit technique is useful in other body parts to resolve the long scan time of an MRI examination.

Comparison of Weight Control Behavior and Self-esteem between Healthy Weight and Obese Children (건강체중아 및 비만아의 체중조절 경험, 식습관, 운동습관 및 자아존중감 비교)

  • Baek, Seol-Hyang;Yeo, Jung-Hee
    • Korean Journal of Community Nutrition
    • /
    • v.11 no.5
    • /
    • pp.562-574
    • /
    • 2006
  • The study compared eating and physical activity related behaviors and self-esteem between healthy weight and obese children by presenting 175 primary school students in Busan City and Gyeongsang province with a self-reported questionnaire and Coopersmith's self-esteem inventory. The questionnaire was composed of 25 items, weighted primarily by a Likert scale. The self-esteem inventory presented to the students comprised 25 'Yes' or 'No' response questions to different statements. The study found obese children were more likely to think they always had to control their weight (p=0.000), reportedly measuring their weights significantly more than the healthy weight children. Also the study found that obese children are significantly more likely than healthy weight children to go on a diet, however neither group were successful in losing weight as the duration of the diet in 79.5% of the total sample lasted no longer than one week. In comparison to healthy weight children, obese children reported that they consumed fewer snacks during the day, avoided snacking subsequent to an evening meal and exercised more frequently for as long as physically possible. Interestingly, we found no difference of reported self-esteem between groups, though the obese group were more likely to answer that their parents did not understand them (p=0.055) Based on these findings, we concluded that the obese children who participated in the study were more aware of their body weights than the healthy weights children. It may be necessary to investigate further the relationship between self-esteem and participants' weights while considering other variables such as personality and body image.

Changes in the Volume and Cortical Thickness of the Specific Regions of Cerebellum of Patients with Major Depressive Disorder (주요우울장애 환자에서 소뇌 국소 부위의 부피와 피질 두께의 차이)

  • Kang, Ji-Won;Han, Kyu-Man;Won, Eunsoo;Tae, Woo-Suk;Ham, Byung-Joo
    • Korean Journal of Biological Psychiatry
    • /
    • v.25 no.3
    • /
    • pp.60-71
    • /
    • 2018
  • Objectives A growing body of evidence has suggested that morphologic changes in cerebellum may be implicated with pathophysiology of major depressive disorder (MDD). The aim of this study is to investigate a difference in the volume and cortical thickness of the specific region of cerebellum between patients with MDD and healthy controls (HC). Methods A total of 127 patients with MDD and 105 HC participated in this study and underwent T1-weighted structural magnetic resonance imaging. We analyzed volume and cortical thickness of each twelve cerebellum regions divided by left and right and the volume and cortical thickness of the whole cerebellum from T1-weigted image of participants. One-way analysis of covariance was used to investigate the volume and cortical thickness difference of total and specific regions between two groups adjusting for age, gender, medication, and total intracranial cavity volume. Results We found that the patients with MDD had significantly greater volume in the left cerebellum lobule III region [false discovery rate (FDR)-corrected p = 0.034] compared to HC. Also, our findings indicate that cortical thickness of left lobule VIIB (FDR-corrected p = 0.032) and lobule VIIIB (FDR-corrected p = 0.032) are significantly thinner in the patients with MDD compared with the HC. No significant volume and cortical thickness differences were observed in other sub-regions of the cerebellum. The volumes and cortical thickness of whole cerebellum between patients with MDD and HC did not differ significantly. Conclusions We observed the region-specific volume and cortical thickness difference in cerebellum between the patients with MDD and HC. The results of our study implicate that the information about structural alterations in cerebellum with further replicative studies might provide a stepping stone toward a specific marker to diagnose MDD.

  • PDF

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

Usefulness of the PRESS Technique using 3.0T Magnetic Resonance Spectroscopy for Evaluation of Non-Alcoholic Fatty Liver Disease Patients (비알콜성 지방간환자 평가를 위한 3.0T 고자기장 자기공명분광법을 이용한 PRESS 기법의 유용성)

  • Goo, Eun-Hoe
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5931-5936
    • /
    • 2012
  • This study was to evaluate the clinical usefulness of the PRESS technique based on the correlation between PRESS technique and biopsy results by applying 3.0T high magnetic field MRS technique for evaluation of non-alcoholic fatty liver disease patients. This experiment were carried out using a 3.0T magnetic resonance imaging equipment. The part data of each spectrum is taken by peak area integration. The part data of resonance peak was used to calculate relative ratio. MR spectral peak in patients with non-alcoholic fatty liver disease is from 0.9 to 1.6 ppm. According to MRS method study result, Patients with NAFLD were obtained with 94% sensitivity and 80% specificity(p=0.000). When compared to normal based on MRS and Biopsy results was valid correlation(r=0.79, p=0.04). Results for NAFLD(r=0.89, p=0.002) also showed a correlation. Therefore, PRESS technique to evaluate patients with non-alcoholic fatty liver disease, the distribution difference between normal liver and fatty liver part is significantly distinguished. Biopsy and MRS fatty liver peak ratio(%) proves high lipid over grade(r = 0.7).

Developing a Korean Standard Brain Atlas on the basis of Statistical and Probabilistic Approach and Visualization tool for Functional image analysis (확률 및 통계적 개념에 근거한 한국인 표준 뇌 지도 작성 및 기능 영상 분석을 위한 가시화 방법에 관한 연구)

  • Koo, B.B.;Lee, J.M.;Kim, J.S.;Lee, J.S.;Kim, I.Y.;Kim, J.J.;Lee, D.S.;Kwon, J.S.;Kim, S.I.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.3
    • /
    • pp.162-170
    • /
    • 2003
  • The probabilistic anatomical maps are used to localize the functional neuro-images and morphological variability. The quantitative indicator is very important to inquire the anatomical position of an activated legion because functional image data has the low-resolution nature and no inherent anatomical information. Although previously developed MNI probabilistic anatomical map was enough to localize the data, it was not suitable for the Korean brains because of the morphological difference between Occidental and Oriental. In this study, we develop a probabilistic anatomical map for Korean normal brain. Normal 75 blains of T1-weighted spoiled gradient echo magnetic resonance images were acquired on a 1.5-T GESIGNA scanner. Then, a standard brain is selected in the group through a clinician searches a brain of the average property in the Talairach coordinate system. With the standard brain, an anatomist delineates 89 regions of interest (ROI) parcellating cortical and subcortical areas. The parcellated ROIs of the standard are warped and overlapped into each brain by maximizing intensity similarity. And every brain is automatically labeledwith the registered ROIs. Each of the same-labeled region is linearly normalize to the standard brain, and the occurrence of each legion is counted. Finally, 89 probabilistic ROI volumes are generated. This paper presents a probabilistic anatomical map for localizing the functional and structural analysis of Korean normal brain. In the future, we'll develop the group specific probabilistic anatomical maps of OCD and schizophrenia disease.

Morphologic Alterations in Amygdala Subregions of Adult Patients with Bipolar Disorder

  • Lee, Hyun-Jae;Han, Kyu-Man;Kim, Aram;Kang, Wooyoung;Kang, Youbin;Kang, June;Won, Eunsoo;Tae, Woo-Suk;Ham, Byung-Joo
    • Korean Journal of Biological Psychiatry
    • /
    • v.26 no.1
    • /
    • pp.22-31
    • /
    • 2019
  • Objectives Previous studies have revealed inconsistent results on amygdala volume in adult bipolar disorder (BD) patients compared to healthy controls (HC). Since the amygdala encompasses multiple subregions, the subtle volume changes in each amygdala nucleus might have not been fully reflected in the measure of the total amygdala volume, causing discrepant results. Thus, we aimed to investigate volume changes in each amygdala subregion and their association with subtypes of BD, lithium use and clinical status of BD. Methods Fifty-five BD patients and 55 HC underwent T1-weighted structural magnetic resonance imaging. We analyzed volumes of the whole amygdala and each amygdala subregion, including the anterior amygdaloid area, cortico-amygdaloid transition area, basal, lateral, accessory basal, central, cortical, medial and paralaminar nuclei using the atlas in the FreeSurfer. The volume difference was analyzed using a one-way analysis of covariance with individual volumes as dependent variables, and age, sex, and total intracranial volume as covariates. Results The volumes of whole right amygdala and subregions including basal nucleus, accessory basal nucleus, anterior amygdaloid area, and cortico-amygdaloid transition area in the right amygdala of BD patients were significantly smaller for the HC group. No significant volume difference between bipolar I disorder and bipolar II disorder was found after the Bonferroni correction. The trend of larger volume in medial nucleus with lithium treatment was not significant after the Bonferroni correction. No significant correlation between illness duration and amygdala volume, and insignificant negative correlation were found between right central nucleus volume and depression severity. Conclusions Significant volume decrements of the whole amygdala, basal nucleus, accessory basal nucleus, anterior amygdaloid area, and cortico-amygdaloid transition area were found in the right hemisphere in adult BD patients, compared to HC group. We postulate that such volume changes are associated with altered functional activity and connectivity of amygdala nuclei in BD.

Perfusion MR Imaging of the Brain Tumor: Preliminary Report (뇌종야의 관류 자기공명영상: 예비보고)

  • 김홍대;장기현;성수옥;한문희;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.119-124
    • /
    • 1997
  • Purpose: To assess the utility of magnetic resonance(MR) cerebral blood volume (CBV) map in the evaluation of brain tumors. Materials and Methods: We performed perfusion MR imaing preoperatively in the consecutive IS patients with intracranial masses(3 meningiomas, 2 glioblastoma multiformes, 3 low grade gliomas, 1 lymphoma, 1 germinoma, 1 neurocytoma, 1 metastasis, 2 abscesses, 1 radionecrosis). The average age of the patients was 42 years (22yr -68yr), composed of 10 males and S females. All MR images were obtained at l.ST imager(Signa, CE Medical Systems, Milwaukee, Wisconsin). The regional CBV map was obtained on the theoretical basis of susceptibility difference induced by first pass circulation of contrast media. (contrast media: IScc of gadopentate dimeglumine, about 2ml/sec by hand, starting at 10 second after first baseline scan). For each patient, a total of 480 images (6 slices, 80 images/slice in 160 sec) were obtained by using gradient echo(CE) single shot echo-planar image(EPI) sequence (TR 2000ms, TE SOms, flip angle $90^{\circ}$, FOV $240{\times}240mm,{\;}matrix{\;}128{\times}128$, slice-thick/gap S/2.S). After data collection, the raw data were transferred to CE workstation and rCBV maps were generated from the numerical integration of ${\Delta}R2^{*} on a voxel by voxel basis, with home made software (${\Delta}R2^{*}=-ln (S/SO)/TE). For easy visual interpretation, relative RCB color coding with reference to the normal white matter was applied and color rCBV maps were obtained. The findings of perfusion MR image were retrospectively correlated with Cd-enhanced images with focus on the degree and extent of perfusion and contrast enhancement. Results: Two cases of glioblastoma multiforme with rim enhancement on Cd-enhanced Tl weighted image showed increased perfusion in the peripheral rim and decreased perfusion in the central necrosis portion. The low grade gliomas appeared as a low perfusion area with poorly defined margin. In 2 cases of brain abscess, the degree of perfusion was similar to that of the normal white matter in the peripheral enhancing rim and was low in the central portion. All meningiomas showed diffuse homogeneous increased perfusion of moderate or high degree. One each of lymphoma and germinoma showed homogenously decreased perfusion with well defined margin. The central neurocytoma showed multifocal increased perfusion areas of moderate or high degree. A few nodules of the multiple metastasis showed increased perfusion of moderate degree. One radionecrosis revealed multiple foci of increased perfusion within the area of decreased perfusion. Conclusion: The rCBV map appears to correlate well with the perfusion state of brain tumor, and may be helpful in discrimination between low grade and high grade gliomas. The further study is needed to clarify the role of perfusion MR image in the evaluation of brain tumor.

  • PDF

Selection of TI for Suppression Fat Tissue of SPAIR and Comparative Study of SPAIR and STIR of Brain Fast SE T2 Weighted Imaging (뇌의 고속스핀에코 T2강조영상에서 지방조직 억제를 위한 SPAIR의 반전시간(TI) 결정 및 STIR 영상과의 비교 연구)

  • Lee, Hoo-Min;Kim, Ham-Gyum;Kong, Seok-Kyo
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.95-99
    • /
    • 2009
  • The purpose of this research is to seek SPAIR's reversal time (TI) which satisfies two conditions ; maintaining the suppression ability of fat tissue and simultaneously minimizing the inhomogeneity of fat tissue in T2 high-speed spin echo 3.0T magnetic resonance image (MRI) of the brain, and to compare SPAIR with STIR which is fat-suppression technique. The reversal times (TI) of SPAIR protocol are set to 1/2, 1/3, 1/6 and 1/12 of SPAIR TR (420 msec), namely 210 msec (8 people), 140 msec (26 people), 70 msec (26 people) and 35 msec (18 people) and STIR TI is set with 250 msec (26 people). With these parameter sets, we acquired the axis direction 104 images of the brain. In ROI ($50\;mm^2$) of output image, signal intensities of the fatty tissue, the muscular tissue, and the background were measured and the CNRs of fatty tissue and the muscular tissue were calculated. The inhomogeneity of the fatty tissue is SD/mean, where SD is the standard deviation and 'mean' is a average fatty tissue signal. Consequently, SPAIR TI is determined on either 1/3 or 1/6 of TR (420 ms) ; 140 ms or 70 ms. Because the difference of statistics in fat-suppression ability and inhomogeneity of fatty tissue is very small (p < 0.001), Selecting 140 ms seems to be better choice for the image quality. Meanwhile, Comparing SPAIR (TI : 140 ms) with STIR, the fat-suppression is not able to be considered statistically (p < 0.252), but the image quality is able to be considered statistically (p < 0.01). In conclusion, SPAIR is better than STIR in the image quality.

  • PDF

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.