• 제목/요약/키워드: Weight shift

검색결과 239건 처리시간 0.038초

Al/Cu 복합도체 제조 및 전기적 특성 평가 (Fabrication and Electrical Evaluation of Al/Cu Composite Conductor)

  • 심기덕;조전욱;배준한;정원모;신덕수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.621-622
    • /
    • 2005
  • Copper is widely used in electric wire, cable, conductor in electric devices. As the demand for electric power is increasing rapidly, electric power devices are getting amazingly bigger and complicated. The using of light-weight conductor can reduce the size and making cost of the electric devices. In high-frequency application, Electric current the current in a conductor tends to shift to the surface of the conductor, resulting in an uneven current distribution in the inner conductor. In the extreme case the current may essentially concentrate in the "skin" of the inner conductor as a surface current. In high frequency application, therefore, inner area of copper conductor may replace with aluminum conductor, which reduces the weight of conductor. This paper describes the manufacture and evaluation of composite conductors made of copper and aluminum.

  • PDF

Escherichia coli의 Peroxidase Isoenzyme에 미치는 온도의 영향 (Effects of Temperature on the Isoenzymes of Peroxidase in Escherichia coli)

  • 강사욱;강현삼;홍순우
    • 미생물학회지
    • /
    • 제14권1호
    • /
    • pp.39-47
    • /
    • 1976
  • This experiment was designed to study the effects of temperature on the peroxidase isoenzymes of a mesophilic microorganism, Escherichia coli (grown within biokinetic zone). Optimum temperature for the growth of E. coli was $37{\circ}C.$ Three different temperatures, 20, 30 and $40{\circ}C,$ were selected. And the isoenzyme patterns of peroxidase of E. coli, growth respectively at each temperature, were analysed by disc electrophoresis. The sample of 20.deg.C showed 4 bands, that of 30.deg.C, 5 bands and that of 40.deg.C, 6 bands. Two dark bands (higher molecular weight, 56,000 and 54,000) and two light bands (lower molecular weight, 11,500 and 10,000) were constant at all samples. But two intermediate bands (M.W.44,000 and 34,000) were variable ; at $20{\circ}C,$ no banding pattern, one band 9M.W. 34,000) only at $30{\circ}C,$ and at $40{\circ}C$ two bands were appeared. And the shifts of growth temperatures between 30.deg.C and 40.deg.C showed the alteration of the isoenzyme patterns ; the isoenzyme patterns of the smaple of tmeperature shift from $30{\circ}C$ to $40{\circ}C$ were same as that of 40.deg.C and vice versa.

  • PDF

관절오목 이형성이 있는 개의 내측 슬개골 탈구 수술 전, 후의 운동역학적 보상적 보행 변화 (증례보고) (Compensatory Change of a Dog with Glenoid Dysplasia in Kinetic Gait Analysis before and after Reconstruction of Medial Patellar Luxation (Case report))

  • 이신호;서정현;차유리
    • 대한물리치료과학회지
    • /
    • 제31권1호
    • /
    • pp.46-52
    • /
    • 2024
  • Background: This study aims to investigate compensatory strategy in a dog with glenoid dysplasia using kinetic gait analysis before and after reconstruction of medial patellar luxation. Design: Case report Method: On the platform, gait analysis was evaluated for a dog with congenital luxation and bilateral medial patellar luxation (MPL). A dog was evaluated for maximal vertical force (MVF), body load distribution (BLD), and symmetry index (SI), including the left forelimb with congenital luxation before MPL surgery, 15 days of surgery, and 40 days of surgery. Result:: In the comparison between the preoperative and the 15 days of surgery, the MVF of the bilateral forelimbs, especially in the non-affected forelimbs, increased, and the SI also increased. For BLD, the maximum load distribution increased, but the total load distribution decreased. In the comparison of 15 days and 40 days of surgery, MVF and BLD increased, and SI decreased on 40days of surgery. Conclusions: In a dog, the shift in weight load to the non-affected side occurs all the limbs, affecting the peak vertical force, weight load distribution, and symmetry index.

이중 에너지 X선 흡수 계측법을 이용한 BMD 검사 시 발생할 수 있는 기술적인 오류 분석 (The Study of Technical Error Analysis on BMD Using DEXA)

  • 강영한;조광호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권4호
    • /
    • pp.229-236
    • /
    • 2006
  • 연구목적: 이중 에너지 X선 흡수 계측법(DEXA, dual-energy X-ray absorptiometry)을 이용한 골다공증 진단 시 발생할 수 있는 기술적인 오류의 유형을 분석하고, 골밀도(BMD, bone mineral density) 값에 미치는 영향에 대해 알아보고자 실시하였다. 연구대상 및 방법: 환자 정보(연령, 체중, 신장, 폐경연령) 입력 오류와 관심영역(ROI, region of interest) 설정에 대한 오류로 나누어 연구하였다. 환자정보 입력 오류는 연령과 폐경연령을 5살, 10살 많게 또는 적게 입력하고, 신장과 체중도 동일한 조건으로 증감하며 입력하여 척추팬텀으로 각각 10회씩 스캔하였다. ROI 설정 오류는 폐경기 여성 10명을 대상으로 스캔을 실시하여 요추부, 고관절부, 전완으로 나누어 ROI를 변화시키며 $BMD(g/cm^2)$, T-score 값을 얻었고, 각각의 결과 값으로 정밀도 1%를 적용하여 평균에 대한 차이 분석을 실시하였다. 결 과: 연령과 신장, 체중 폐경연령에 대한 환자 정보 입력 오류는 정밀도 1%에서 유의하지 않게 나타났다. ROI 설정 오류는 요추부 ROI 설정 시 ROI 기준선을 좌우 1 cm, 2 cm 좁혔을 때 평균 $0.006\;g/cm^2$, 0.1 그리고 $0.021\;g/cm^2$, 0.15 감소하였다. 제 12흉추를 포함하였을 때 $BMD(g/cm^2)$와 T-score는 평균 $0.063\;g/cm^2$, 0.3 감소하였고, 제 5번 요추를 포함하였을 때 각각 $0.077\;g/cm^2$, 0.5 증가하였다. 고관절 관심영역을 대퇴골두 위쪽 또는 좌측으로 0.5 cm 이동하였을 때의 결과 값은 평균에 대한 차이를 보이지 않았다. 하지만 소전자 아래쪽 0.5 cm, 1 cm 이동하였을 때의 $BMD(g/cm^2)$와 T-score는 $0.031\;g/cm^2$, 0.3 그리고 $0.094\;g/cm^2$, 0.65로 증가하였다. 전완의 관심영역을 수근부 아래쪽, 위쪽으로 1 cm으로 이동하였을 때 $BMD(g/cm^2)$와 T-score는 $0.042\;g/cm^2$, 0.9 감소 또는 $0.096\;g/cm^2$, 0.40 증가하였다. 좌우 기준선이 1 cm, 2 cm 넓어질 때 $BMD(g/cm^2)$, T-Score는 평균 $0.008\;g/cm^2$, 0.1 증가 또는 $0.021\;g/cm^2$, 0.3으로 증가하였다. 결 론: 골밀도 측정 시 발생할 수 있는 기술적인 오류는 다양하며, 오류에 따라 정상 BMD 값과 T-score에 변동이 있음을 알 수 있었다. 환자정보 입력과정에 발생할 수 있는 연령과 체중, 신장, 폐경 연령에 따른 입력오류는 BMD와 T-score에 영향을 미치지 않았으나 일반적 골밀도 검사 시에는 중요한 요소이다. ROI 지정 오류 시에는 BMD 값과 T-score에 유의한 차이가 있었다. 정확한 골밀도 검사를 위해서는 환자 정보에 대해서도 자세한 파악이 있어야 하겠지만 검사자의 기술적 지식이 결과 값에 영향을 미치게 됨을 충분히 인지하고 검사에 임하여야 하겠다.

  • PDF

LB막을 누적한 수정진동자의 온도 및 유기가스 반응특성 (The Temperature and Organic Gas Properties of Quartz Crystal Coated with LB Films)

  • 유승엽;김경환;진철남;박재철;권영수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권7호
    • /
    • pp.508-513
    • /
    • 1999
  • The response properties of quartz crystal coated with stearic acid LB films to organic gases were investigated by measuring the shift of resonant frequency. Stearic acid was used as a sensing material and deposited on the surface of quartz crystal using the Langmuir-Blodgett(LB) method. The effect of temperature on the quartz crystal coated with stearic acid LB films was also investigated by Scanning Maxwell-stress Microscopy(SMM). As a result, the sensitivity of the quartz crystal coated with LB films to organic gases is dependent on temperature, thickness of LB film and molecular weight of organic gas.

  • PDF

파이프 비닐온실용 권취식 창개폐기의 개발 (Development of roll - up ventilation system for pipe- constructed plastic film greenhouse)

  • 이기명;박규식;김유일;김태홍
    • 생물환경조절학회지
    • /
    • 제4권2호
    • /
    • pp.232-239
    • /
    • 1995
  • This study was carried out to get required torque data needed to design and develop a roll-up ventilation system in a pipe-constructed plastic film green-house. The results obtained from this study are as follows : 1. The required torques of a roll-up ventilation system in greenhouse are the functions of its length. The torques should multiplied by the conversion coefficients (2.0 in ceiling vent, 1.8 in side vent) in case of application. 2. In constructing pipe-constructed plastic film greenhouse, a shaft pipe is the largest essential element in roll - up shaft weight constitution which have an effect on the required torques. Therefore, the pipe should be light using nonferrous materials like aluminum alloy. 3. A planetary reduction ventilator of differential ring gear type is suitable for a roll-up ventilation system, because it can make high efficient reduction just using the first step shift.

  • PDF

자전거 시뮬레이터를 이용한 평형감각 증진의 정량적 분석 (Quantitative Analysis on the Improvement of Equilibrium Sensory Using Bicycle Simulator)

  • 정성환;정우석;김경석;권대규;홍철운;김남균
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.935-938
    • /
    • 2004
  • This paper describes the quantitative analysis on the improvement of equilibrium sensory using virtual bicycle system. We have used a virtual bicycle system that combines virtual reality technology with a bicycle. In this experiment, 10 subjects were tested to investigate the influencing factors on equilibrium sensory. Straight road and curved road driving at several factors including cycling time, number of times of path deviation, and center of pressure(COP) were extracted and evaluated to quantify the extent of control. Also, To improve the effect of balance training, we investigated the usefulness of virtual feedback information by weight shift. The result showed that the system could be effective for equilibrium sensory rehabilitation training device. The analysis method might also have wider applicability to the rehabilitation field.

  • PDF

소프트 스위칭 방식을 이용한 X-Ray용 DC-DC Converter에 관한 연구 (A Study on DC-DC Converter for X-Ray Using Soft-Switching Method)

  • 김학성;김현준;원충연;유동욱;하성운
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.379-381
    • /
    • 1994
  • This paper is concerned with a zero-voltage soft-switching PWM DC-DC high-pelter converter using IGBTs, which Bakes the most of the parastic LC parameters of high-voltage transformer link, for diagnostic X-Ray power generator. The converter circuit basically utilizes phase-shift pulse width modulated series resonant full-bridge PWM DC-DC high-Power converter operating at a constant frequency:20kHz. This technique brings about dramatic decreases in the switching losses of power devices and their electrical stresses as compared with the commonly-used hard-switching PWM DC-DC power converter. The high-frequency switching operation of the converters has some effective advantages, which consist in the physical reduction in size and weight and lowered acoustic noise.

  • PDF

점탄성 물질의 온도와 주파수 의존성을 고려한 구속형 제진보의 최대 손실계수 설계 (Optimal Layout Design of Frequency- and Temperature-Dependent Viscoelastic Materials for Maximum Loss Factor of Constrained-Layer Damping Beam)

  • 이두호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1023-1026
    • /
    • 2007
  • Optimal damping layout of the constrained viscoelastic damping layer on beam is identified with temperatures by using a gradient-based numerical search algorithm. An optimal design problem is defined in order to determine the constrained damping layer configuration. A finite element formulation is introduced to model the constrained damping layer beam. The four-parameter fractional derivative model and the Arrhenius shift factor are used to describe dynamic characteristics of viscoelastic material with respect to frequency and temperature. Frequency-dependent complex-valued eigenvalue problems are solved by using a simple resubstitution algorithm in order to obtain the loss factor of each mode and responses of the structure. The results of the numerical example show that the proposed method can reduce frequency responses of beam at peaks only by reconfiguring the layout of constrained damping layer within a limited weight constraint.

  • PDF

자동변속기유가 연비에 미치는 영향에 대한 연구 (A Study for Effects of Automatic Transmission Fluid on Fuel Economy)

  • 차상엽;양시원
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.117-122
    • /
    • 2004
  • In order to improve the fuel economy by design change of automatic transmission, various technologies such as increased shift stages, slip control of lock-up clutch and compact and low-weight design have been developed. And also many OEMs have developed their own ATFs as a part of these automatic transmissions. In this study. to investigate the effects of ATF characteristics on fuel economy, we got the worldwide OEM ATFs and made some reference fluids. And physical properties, frictional characteristics and fuel economy using dynamometer test for these fluids were evaluated. From the investigation, it was found that viscosities of ATFs are correlated with fuel economy in dynamometer test and reducing the viscosities made it possible to obtain fuel economy.

  • PDF