• Title/Summary/Keyword: Weight ball

Search Result 278, Processing Time 0.024 seconds

Prediction of Concrete Slab Acceleration and Floor Impact Noise Using Frequency Response Function (주파수 응답함수를 이용한 콘크리트 슬래브 가속도 및 바닥충격소음 예측)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.6
    • /
    • pp.483-492
    • /
    • 2014
  • Uncomfortable feelings of occupants by indoor floor impact noise in a residential building are not accurately represented by the floor impact noise from a standard impact source. It is due to the characteristics of standard impact sources, which are different from the impact forces produced by occupants. It varies significantly by impact source, and it is not easy to be replicated for testing. As a result, the indoor floor impact noise under different acoustic conditions cannot be directly compared. Using frequency response function(FRF), which represents the input-output relationships of a dynamic system, it is possible to examine the characteristics of the system. Especially, FRF can predict the response of a linear dynamic system subjected to various excitation. To determine the relationship between impact force and the corresponding response of dynamic system in residential building, the acceleration response of a concrete slab and the floor impact noise in the living room, produced by bang-machine and rubber-ball excitation, were measured. The test results are compared to the estimates based on FRF and impact force spectrum.

Analysis of Load Input to Vehicle Body Due to Diversification of Environment of Towing Device (견인 장치 사용 환경 다양화에 따른 차체 입력하중 분석)

  • Choi, Jaesung
    • Journal of Applied Reliability
    • /
    • v.18 no.1
    • /
    • pp.40-48
    • /
    • 2018
  • Purpose: This research is to develop Trailer Durability Test of towing device, in order to cover usage conditions of bike type as well as general type trailer. With the diversification of leisure activities, the population that enjoys various sports and leisure has increased rapidly, and the number of vehicles equipped with camping trailers and bike carriers is also increasing steadily. The purpose of this study is to develop a durable vehicle that has no problem in various customer conditions. Methods: We measured the input load under various conditions of the user by attaching load cell to the body fixing part and towing ball of the towing device. The load in various modes was measured, and the difference between the trailer and the bike carrier type was compared and analyzed. Results: Due to the difference in fixing method and weight between the two types, the trailer has a large longitudinal force and the bike type has a large vertical force. Therefore, it is necessary to durability test method capable of satisfying all longitudinal force and vertical force. Conclusion: We improved the durability test of the towing device by changing the test surface. The new mode has made it possible to shorten the durability test schedule by increasing test efficiency.

A Study on the/ Correlation Between Board Level Drop Test Experiment and Simulation

  • Kang, Tae-Min;Lee, Dae-Woong;Hwang, You-Kyung;Chung, Qwan-Ho;Yoo, Byun-Kwang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.2
    • /
    • pp.35-41
    • /
    • 2011
  • Recently, board level solder joint reliability performance of IC packages during drop impact becomes a great concern to semiconductor and electronic product manufacturers. The handheld electronic products are prone to being dropped during their useful service life because of their size and weight. The IC packages are susceptible to solder joint failures, induced by a combination of printed circuit board (PCB) bending and mechanical shock during impact. The board level drop testing is an effective method to characterize the solder joint reliability performance of miniature handheld products. In this paper, applying the JEDEC (JESD22-B111) standard present a finite element modeling of the FBGA. The simulation results revealed that maximum stress was located at the outermost solder ball in the PCB or IC package side, which consisted well with the location of crack initiation observed in the failure analysis after drop reliability tests.

Dry sliding wear behavior of plain low carbon dual phase steel by strain hardening and oxidation (가공경화와 산화층 형성에 의한 이상조직 저탄소강의 건식 미끄럼 마멸 거동)

  • Yu, H.S.;Kim, Y.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.149-152
    • /
    • 2006
  • Dry sliding wear behavior of low carbon dual phase steel, of which microstructure consists of hard martensite in a ductile ferrite matrix, has been investigated. The wear characteristics of the dual phase steel was compared with that of a plain carbon steel which was normalized at $950^{\circ}C$ for 30min and then air-cooled. Dry sliding wear tests were carried out using a pin-on-disk type tester at various loads of 1N to 10N under a constant sliding speed condition of 0.2m/sec against an AISI 52100 bearing steel ball at room temperature. The sliding distance was fixed as 1000m for all wear tests. The wear rate was calculated by dividing the weight loss measured to the accuracy of $10^{-5}g$ by the specific gravity and sliding distance. The worn surfaces and wear debris were analyzed by SEM, EDS and a profilomter. Micro vickers hardness values of the cross section of worn surface were measured to analyze strain hardening behavior underneath the wearing surfaces. The were rate of the dual phase steel was lower than the plain carbon steel. Oxidation on the sliding surface and strain hardening were attributed for the higher wear resistance of the dual phase steel.

  • PDF

The Effect of Shot Peening on Corrosive Behavior of SAE 5155 in $3.5\%$ NaCl Solution ($3.5\%$ NaCl수용액에서 SAE 5155의 부식거동에 미치는 쇼트피닝의 영향)

  • An Jae-Pil;Park Keyung-Dong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.692-700
    • /
    • 2005
  • In this study. investigated the effect of shot peening on the corrosion of SAE 5155 steel immersed in $3.5\%$ NaCl solution and corrosion characteristics by the heat treatment during shot peening process. The immersion test was Performed on the four kinds of specimens. Corrosion Potential, polarization curve, residual stress etc. were investigated from experimental results. From these test results, the effect of shot peening on the corrosion was evaluated The important results of the experimental study on the effects of shot peened SAE 5155 on the corrosion are as follows; Shot peened specimens show the low of corrosion current as compared with un peened specimens. In the case of corrosion potential, shot Peened specimen shows more negative Potential as compared with that of parent metal Surface of specimen, which is treated with shot peening Process. is Placed as more activated state against inner parent metal. Corrosion rate is shown that shot Peened specimens have less corrode than un peened specimens. But non heat treated shot peened specimens show the biggest weight loss owing to variable compressive residual stress layer by shot ball.

A study on Titanium Hydride Formation of Used Titanium Aircraft Scrap for Metal Foaming Agents

  • Hur, Bo-Yong;Ahn, Duck-Kyu;Kim, Sang-Youl;Jeon, Sung-Hwan;Park, Su-Han;Ahn, Hyo-Jun;Park, Chan-Ho;Yoon, Ik-Sub
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.209-212
    • /
    • 2001
  • Aircraft industry is developed very fast so titanium scrap was generated to manufacture. Titanium scrap was wasted and used to deoxidize cast iron so we are study recycling of it. In this research were studied that metal hydride of reacted in hydrogen chamber of AMS4900, 4901, return scrap titanium alloy and sponge titanium granule. The temperature of hydrogenation was 40$0^{\circ}C$ in the case of pure sponge titanium but return scrap titanium alloy were step reaction temperature at 40$0^{\circ}C$ and 50$0^{\circ}C$, and after the hydride of titanium alloy were crushed by ball mill for 5h. Titanium hydride contains to 4wt.% of hydrogen theoretically as theory. It was determined by heating and cooling curve in reaction chamber. The result of XRD was titanium hydride peak only that it was similar to pure titanium. Titanium hydride Powder particle size was about 45${\mu}{\textrm}{m}$, and recovery ratio was 95w% compared with scrap weight for a aluminum foam agent.

  • PDF

Enhancement of Dissolution Properties of Poorly Soluble Drugs (III) -Dissolution Enhancement of Furosemide from Ground Mixtures with Chitin or Chitosan- (난용성 약물의 용출 증가 (제 3 보) -키틴 또는 키토산과의 혼합분쇄물로부터의 푸로세미드의 용출 증가-)

  • Shin, Sang-Chul;Oh, In-Joon;Lee, Kang-Choon;Lee, Yong-Bok;Koh, Ik-Bae
    • Journal of Pharmaceutical Investigation
    • /
    • v.17 no.4
    • /
    • pp.175-181
    • /
    • 1987
  • To increase the dissolution rate of furosemide, chitin and chitosan which are widely occurring biodegradable natural materials were used as drug carriers. The ground mixtures of furosemide with chitin or chitosan were prepared by grinding in a ball mill. The ground mixture showed a faster and more enhanced dissolution rate than the physical mixture or intact furosemide. The crystalline peaks of furosemide disappeared in the ground mixtures indicating the production of amorphous form. The comparison of infrared spectra of the physical mixture and the ground mixture showed an interaction such as association between the functional groups of furosemide and chitin or chitosan in the molecular level. The weight losses in TGA curves showed all the same patterns. However, the endothermic peak due to the fusion of furosemide in DTA curve disappeared in the ground mixture indicating the different thermal property. The dissolution of furosemide from ground mixtures was fast in the order of chitosan and then chitin. The co-grinding technique with chitin or chitosan provided a promising way enhancing the dissolution rate of practically insoluble drug.

  • PDF

Effects of the Support Surface Condition on Muscle Activity of Trunk Muscles during Balance Exercises in Patients with Stroke

  • Jung, Kyoung-Sim;Kim, Yong-Su;In, Tae-Sung
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.4
    • /
    • pp.196-200
    • /
    • 2015
  • Purpose: The purpose of this study was to examine the muscle activity of the trunk muscles during balance exercises on a stable and unstable surface in patients with stroke. Methods: Thirteen subjects (8 males, 5 females) with stroke were enrolled in the study. Muscle activity was recorded using surface EMG electrodes from the affected side of the erector spinae, external oblique, and internal oblique muscles. The exercise was performed under three conditions. For the first condition for balance exercise, subjects were instructed to sit on an exercise mat with legs extended. The second condition was to sit with legs extended, with a balance pad under their buttocks. The third condition was to sit with legs extended, have a balance pad under the buttocks and a balance cushion under the lower legs. Results: This study showed significant differences in EMG activities during both arm lifting exercise and weight shifting exercise between conditions. This study showed that the EMG activities of the erector spinae, external oblique, and internal oblique muscles were significantly higher when the trunk exercise was performed using the balance pad with balance ball than when using the stable surface. Conclusion: In conclusion, performing balance exercises using an unstable surface is a useful method for facilitating trunk-muscle strength and hence trunk stability.

Sliding Wear Mechanism of Ultra-Fine Grained Low Carbon Dual Phase Steel as a Function of Applied Load (경정립 미세화에 따른 이상조직 탄소강의 하중에 따른 마멸기구)

  • Yu, H.S.;Yi, S.K.;Shin, D.H.;Kim, Y.S.
    • Transactions of Materials Processing
    • /
    • v.16 no.4 s.94
    • /
    • pp.299-303
    • /
    • 2007
  • Dry sliding wear behavior of ultra-fine grained(UFG) plain low carbon dual phase steel, of which microstructure consists of hard martensite in a ductile ferrite matrix, has been investigated. The wear characteristics of the UFG dual phase steel was compared with that of a coarse grained dual phase steel under various applied load conditions. Dry sliding wear test were carried out using a pin-on-disk type tester at various loads of 1N to 100N under a constant sliding speed condition of 0.20m/s against an AISI 52100 bearing steel ball at room temperature. The sliding distance was fixed as 1000m for all wear tests. The wear rate was calculated by dividing the weight loss, measured to the accuracy of 10-5g by the specific gravity and sliding distance. The worn surfaces and wear debris were analyzed by SEM, EDS and profilometer. Micro-vickers hardness of the cross section of worn surfaces were conducted to analyze strain hardening underneath the contact surfaces. The wear mechanism of the UFG dual phase steel was investigated with emphasis on the unstable nature of the grain boundaries of the UFG microstructure.

Sliding Wear Behavior of Pure Metal, Fe and Cu Having a Cubic Crystal System (입방정계 순 금속 Fe, Cu의 미끄럼 마멸 거동)

  • Yi, S.K.;Kim, Y.S.
    • Transactions of Materials Processing
    • /
    • v.19 no.6
    • /
    • pp.357-362
    • /
    • 2010
  • Dry sliding wear behavior of pure Fe and Cu which have BCC and FCC crystal structure, respectively, was investigated. The wear characteristics of the pure metals with different crystal structure were compared. Dry sliding wear tests were carried out using a pin-on-disk wear tester at various loads under the constant sliding speed condition of 0.15 m/s against a silica ball at room temperature. Sliding distance was fixed as 600 m for all wear tests. Wear rate of a specimen was calculated by dividing the weight loss of the specimen after the test by the specific gravity and sliding distance. Worn surfaces and wear debris were analyzed by SEM. The wear of both pure Fe and Cu proceeded with surface deformation, resulting in similar wear rates despite of their structure difference under the current test conditions. Wear rates of both metals were low if the surface deformation due to wear forms thick surface-deformation layer that is strain hardened beneath the wearing surface. The pure Cu specimens showed a lot of oxides on the worn surface when tested at low loads less than 5 N, which resulted in very low wear rate.