• Title/Summary/Keyword: Wedge Field

Search Result 199, Processing Time 0.028 seconds

A Case of Papillary Adenocarcinoma Presenting with Multiple Cysts (다발성 낭성 유두상 폐선암 1예)

  • Chon, Su-Yeon;Kim, Yu-Jin;Kyung, Sun-Young;An, Chang-Hyeok;Lee, Sang-Pyo;Park, Jeong-Woong;Jeong, Sung-Hwan;Cho, Eun-Kyung;Sung, Yon-Mi;Kim, Na-Rae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.2
    • /
    • pp.93-96
    • /
    • 2010
  • A 23-year old woman was admitted to our hospital with hemoptysis. The chest X-ray showed reticulonodular opacity and multiple cysts throughout the entire lung field. The chest CT scan revealed numerous bilateral cysts with various sizes, some of them with thickened walls. An open lung wedge resection was performed. The resected specimen showed scattered small nodules, 0.3 to 0.6 cm in size. Microscopically, each nodule was composed of atypical glands with an occasional papillary architecture spreading to the alveolar septa, which were morphologically consistent with a papillary adenocarcinoma with a bronchioloalveolar carcinoma growth pattern. Immunochemically, the tumor cells were negative for the S-100 protein. The patient was diagnosed with an adenocarcinoma of the lung. A variety of diseases can produce or mimic multiple, thin-walled cysts in the lung. Lung cancer with multiple cysts is quite rare. Nevertheless, adenocarcinoma should be a diagnostic consideration. We report a case of a multiple cystic adenocarcinoma of the lung.

Investigations on the Failure Modes of Rock Slopes in Gyeongsangnam-do (경상남도에서 발생한 암반사면의 파괴유형 연구)

  • Park, Choon-Sik;Ha, Jung-Chul
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.569-583
    • /
    • 2018
  • The purpose of this study is to identify the collapse characteristics by analyzing various factors causing collapse based on field survey and existing data on rock slopes occurring in the construction of roads and industrial complexes in Gyeongsangnam - do area. In the case of the slope where the slope has been directly surveyed, the analysis of the collapse characteristics can be used for the prediction and prevention of slope failure through the continuous collection of the slope data, database construction, management and analysis. The evaluation items used in the collapse characteristics of slope were selected among the items that can be regarded as objective evaluation items among the overlapping factors by comparing the evaluation items frequently used for the evaluation of the existing slope stability among various factors. The type of destruction of the rock slope depends on the type of carcass of the bedrock, such as planar fracture, wedge fracture, onho fracture, and conduction fracture, which are different from each other. And the slope stability analysis should be performed accordingly.

Outcomes of Single-Incision Thoracoscopic Surgery Using the Spinal Needle Anchoring Technique for Primary Spontaneous Pneumothorax

  • Lee, Seung Hyong;Lee, Sun-Geun;Cho, Sang-Ho;Song, Jae Won;Kim, Dae Hyun
    • Journal of Chest Surgery
    • /
    • v.55 no.1
    • /
    • pp.44-48
    • /
    • 2022
  • Background: Although classical multi-port video-assisted thoracic surgery has been widely performed, single-incision thoracoscopic surgery (SITS) is a popular surgical technique for the treatment of primary spontaneous pneumothorax (PSP). However, the inconvenient alignment of instruments and the limited field of view occasionally make surgeons convert from SITS to multi-port surgery or extend the incision. This study aimed to present an easy and safe SITS technique for PSP using a spinal needle. Methods: In total, 139 patients underwent SITS between May 2011 and December 2017. We used a spinal needle to hook the bulla or bleb, and wedge resection was performed through a small incision. Patients' medical records were reviewed retrospectively, and a telephone survey was conducted to investigate the recurrence rate. Results: The mean age of the 139 patients was 23.62±9.60 years. The mean operative time was 36.69±14.64 minutes, and multi-port conversion was not performed. The mean postoperative hospital stay was 3.00±0.78 days, and the mean indwelling chest tube duration was 1.97±0.77 days. No complications were observed. In the mean follow-up period of 86.75±23.20 months, recurrence of pneumothorax was found in 3 patients. Conclusion: We suggest that SITS for PSP with the aid of a spinal needle to replace a grasper is a safe and easy technique that only requires a small incision.

Simulation of a neutron imaging detector prototype based on SiPM array readout

  • Mengjiao Tang;Lianjun Zhang;Bin Tang;Gaokui He;Chang Huang;Jiangbin Zhao;Yang Liu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3133-3139
    • /
    • 2023
  • Neutron imaging technology as a means of non-destructive detection of materials is complementary to X-ray imaging. Silicon photomultiplier (SiPM), a new type of optical readout device, has overcome some shortcomings of traditional photomultiplier tube (PMT), such as high-power consumption, large volume, high price, uneven gain response, and inability to work in strong magnetic fields. Its application in the field of neutron detection will be an irresistible general trend. In this paper, a thermal neutron imaging detector based on 6LiF/ZnS scintillation screen and SiPM array readout was developed. The design of the detector geometry was optimized by geant4 Monte Carlo simulation software. The optimized detector was evaluated with a step wedge sample. The results show that the detector prototype with a 48 mm × 48 mm sensitive area can achieve about 38% detection efficiency and 0.26 mm position resolution when using a 300 ㎛ thick 6LiF/ZnS scintillation screen and a 2 mm thick Bk7 optical guide coupled with SiPM array, and has good neutron imaging capability. It provides effective data support for developing high-performance imaging detectors applied to the China Spallation Neutron Source (CSNS).

A retrospective clinical study of isolated patent ductus arteriosus (동맥관 개존증의 임상적 고찰)

  • 곽영태
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.593-606
    • /
    • 1984
  • With the ligation of patent ductus arteriosus by Gross in 1938, surgeons first entered the field of congenital heart disease. Interruption of a ductus is one of the most satisfactory and curative operations in the field of surgery for congenital heart disease. 27 cases of isolated patent ductus arteriosus were operated from Jan. 1978 to July 1984 at the Department of Thoracic & Cardiovascular Surgery in Kyung-Hee University Hospital. Retrospective clinical analysis of these patients were: 1. Sex ratio, female: male, was 2:1. 2. Mean age at operation was 9.85\ulcorner.58 years. The youngest patient was a 23 month-old girl and the oldest one was a 24 year-old male. 3. More than half of the patients had less than 50 percentile of growth retardation. 4. Chief complaints of the patients were frequent URI [52%], dyspnea on exertion [33%], generalized weakness [22%], palpitation [7%], but 7 patients [26%] had no subjective symptoms. 5. Continuous machinery murmur could be heard at the 2nd or 3rd intercostal space on the left sternal border in 22 patients [81%]. The other S patients made systolic murmur with accentuation of the second heart sound and those were associated with pulmonary hypertension. 6. Radiologic findings of Chest P-A were cardiac enlargement in 15 patients [55%], enlargement of pulmonary conus and/or increasing density of pulmonary vascularity in 20 patients [74%]. 7. Electrocardiographic findings of the patients were within normal limit in 13 patients [48%], LVH in 4 patients [15%], biventricular hypertrophy in 3 patients [11%]. 8; echocardiogram was obtained from 11 patients. Ductus was directly visualized in 7 patients. Left atrial enlargement is the secondary change of left to right shunt, 10 patients had LA/Ao ratio more than 1.2. 9. Cardiac catheterization performed in 25 patients. The mean value of the results were:SO2[PA-RV]= 14.72\ulcorner6.01%, Qp/Qs=2.22\ulcorner.80, peak systolic pulmonary arterial pressure=48.28\ulcorner1.60 mmHg. 10. 26 patients were operated through the left posterolateral thoracotomy: closure of ductus by double ligation in 14 cases, triple ligation in 5 cases, and division with suture in 8 cases. One patient suffer from aneurysmal rupture of main pulmonary artery, endocarditis, hemopericardium was treated with cardiopulmonary bypass via median sternotomy and closure of ductus through the ruptured main pulmonary artery. 11.There was no death associated with the operation, but 3 cases were experienced with intraoperative rupture around the ductus resulting in massive bleeding. The other complications were transient hoarseness in one patient, atelectasis in left lower lobe in 3 patients, and postoperative systemic hypertension in 4 patients with unknown etiology. 12. Pulse pressure was reduced, 11.47+5.92 mmHg, postoperatively, as compare to preoperative status. 13. Intraoperative wedge lung biopsy from lingular segment for the evaluation of the pulmonary vascular disease was taken in S patients with severe pulmonary hypertension. The result was Heath-Edward grade I in one case, grade II in two cases, and grade III in two cases.

  • PDF

Lagrangian Finite Element Analysis of Water Impact Problem (강체-유체 충격문제에 대한 Lagrangian 유한요소 해석)

  • Bum-Sang Yoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.1
    • /
    • pp.60-68
    • /
    • 1991
  • The updated Lagrangian Finite Element Method is introduced to analyse rigid body-fluid impact problem which is characterized by incompressible Navier-Stokes equations and impact-contact conditions between free surface and rigid body. For the convenience of numerical computation, velocity fields are splinted into vicous and pressure parts, and then the governing equations and boundary conditions are decomposed in accordance with the decomposition. However, Viscous stresses acting an the solid boundaries are neglected on the assumption that very small velocity gradients may occur during extremely small time interval of the impact. Four coded quadrilateral elements are used to discretize the space domain and the fully explicit time-marching algorithm is employed with a reasonably small time step. At the beginning of each time step, contact velocity of the rigid body is computed from the momentum balance between the body and the fluid. The velocity field is then computed to satisfy the discretized equations of motions and incompressibility and contact constraints as well as an exact free surface boundary condition. At the end of each time step, the fluid domain is updated from the velocity field. In the present time stepping numerical analysis, behaviour of the free surface near the body can be observed without any difficulty which is very important in the water impact problem. The applicability of the algorithm is illustrated by a wedge type falling body problem. The numerical solutions for time-varying pressure distributions and impact loadings acting ion the surface are obtained.

  • PDF

Application of SP Monitoring in the Pohang Geothermal Field (포항 지열 개발지역에서의 SP 장기 관측)

  • Lim Seong Keun;Lee Tae Jong;Song Yoonho;Song Sung-Ho;Yasukawa Kasumi;Cho Byong Wook;Song Young Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.164-173
    • /
    • 2004
  • To delineate geothermal water movement at the Pohang geothermal development site, Self-Potential (SP) survey and monitoring were carried out during pumping tests. Before drilling, background SP data have been gathered to figure out overall potential distribution of the site. The pumping test was performed in two separate periods: 24 hours in December 2003 and 72 hours in March 2004. SP monitoring started several days before the pumping tests with a 128-channel automatic recording system. The background SP survey showed a clear positive anomaly at the northern part of the boreholes, which may be interpreted as an up-flow Bone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. The first and second SP monitoring during the pumping tests performed to figure out the fluid flow in the geothermal reservoir but it was not easy to see clear variations of SP due to pumping and pumping stop. Since the area is covered by some 360 m-thick tertiary sediments with very low electrical resistivity (less than 10 ohm-m), the electrokinetic potential due to deep groundwater flow resulted in being seriously attenuated on the surface. However, when we compared the variation of SP with that of groundwater level and temperature of pumping water, we could identify some areas responsible to the pumping. Dominant SP changes are observed in the south-west part of the boreholes during both the preliminary and long-term pumping periods, where 3-D magnetotelluric survey showed low-resistivity anomaly at the depth of $600m\~1,000m$. Overall analysis suggests that there exist hydraulic connection through the southwestern part to the pumping well.

Field Investigation and Stability Analysis of a Volcanic Rock Slope at the Song-Gok site, Wan-Do (완도 송곡지구 화산암류 비탈면의 현장조사 및 안정성 검토 사례 연구)

  • Kim, Hong-Gyun;Ok, Young-Seok;Kim, Seung-Hyun;Koo, Ho-Bon
    • The Journal of Engineering Geology
    • /
    • v.23 no.2
    • /
    • pp.149-160
    • /
    • 2013
  • Volcanic activity commonly creates a highly complicated volcanic complex due to the admixture of lava flow and sedimentation of volcanic ash. The Song-Gok site is composed of volcanic rocks that collapsed at the lower part of the slope, in combination with several discontinuities in and around a fault. The results of projection analysis indicated the possibility of plane, wedge, and toppling failure in the failure section. The results of discontinuity modeling using the Distinct Element Method (DEM) revealed a total displacement of 207 mm and a joint shear displacement of 114 mm. The yield surface zone was verified at the fault plane of the failure section. In geotechnical terms, volcanic rock slopes are characteristically vulnerable to failure because of differential weathering among the various rock types, the effect of groundwater based on the permeability of the rocks, and the presence of systematic joints generated by the cooling and contraction of lava. When considering the stability of a volcanic rock slope, it is necessary to consider data such as the geological features of the rock, as obtained through detailed geological survey, and variations in discontinuities and rock blocks.

Behavior Characteristics of Underreamed Ground Anchor through Field Test and Numerical Analysis (현장시험 및 수치해석을 통한 확공지압형 앵커의 거동특성)

  • Kim, Gyuiwoong;Ahn, Kwangkuk;Min, Kyongnam;Jung, Chanmuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.8
    • /
    • pp.37-44
    • /
    • 2013
  • The superiority of bearing ground anchor system has been recognized for the stability and economical efficiency since 1950s in Japan, Europe and etc. The ground anchor introduced in Korea, however, has the structural problem that the tensile strength comes only from the ground frictional force caused by the expansion of the wedge body and it is impossible to evaluate the bearing resistance because the adhering method of the anchor body to hollow wall is not appropriate. In this study, the underreamed ground anchor system was developed so that the bearing pressure of ground anchor can exert as much as possible. And the in-situ tests were performed to evaluate the pullout behavior characteristics and to verify the decreasing effect of the bonded length. The pullout tests were performed with the non-grouted tension condition and grouted tension condition in order to identify the pull-out resistance of each conditions. In addition, it was compared with the results of friction anchor. Finally, the numerical analysis was fulfilled to verify the bearing effect at the bonded part through the detailed modeling by PLAXIS-2D, which is general finite element method analysis program.

금속쐐기와 가상쐐기의 출력비교

  • 강위생
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.42-42
    • /
    • 2003
  • 목적 : 조사면 크기에 따른 금속쐐기와 가상쐐기에 의한 6 MV 와 15 MV 엑스선의 출력 및 상부와 하부 에 설치하는 금속쐐기의 출력을 비교하고자 한다. 대상 및 방법 : Varian Clinac21EX(미국)는 두부의 상부와 하부에 설치하는 각각의 금속쐐기와 제한기에 의한 가상쐐기 기능을 가지고 있다. 금속쐐기의 쐐기각은 네 가지 (15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$)이며 투과력에 무관하게 한 쐐기각에 대한 쐐기는 사하부는 각 1 개이고, 가상쐐기는 일곱 가지 ($10^{\circ}$, 15$^{\circ}$, 20$^{\circ}$, 25$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$) 이다. 각 쐐기에 대하여 3$\times$3~20$\times$20 $\textrm{cm}^2$ 의 조사면 크기에서 6 및 15 MV 엑스선의 쐐기출력인수 (wedge field output factor)를 $d_{max}$와 10 $\textrm{cm}^2$ 깊이에서 측정하였다. 조사면크기와 측정깊이에 따른 쐐기출력인수의 변화추이를 관찰하였다. 쐐기출력인수 O $F_{Wdg}$는 다음과 같다. O $F_{Wdg}$(r)= $D_{Wdg}$(r)/ $D_{op}$ ( $r_{0}$) 여기서 $r_{0}$와 r은 각각 민조사면의 기준조사면크기, 쐐기조사면크기이다. 하부쐐기에 대한 상부쐐기의 출력인수의 상대적인 백분율 차이, %ROD=l00$\times$(O $F_{upWdg}$/O $F_{lowWdg}$ lowWdg/ - 1)를 구하였다. 조사면크기와 깊이에 따른 %ROD의 변화추이를 평가하였으며 쐐기 각각에 대하여 출력인수를 측정해야하는지 평가하였다. 결과 : 금속쐐기에 대한 쐐기출력인수는 방사선의 투과력과 깊이에 관계없이 조사면 크기가 커짐에 따라 증가하였으나 가상쐐기의 쐐기출력인수는 쐐기각이 작은 경우에는 조사면크기가 커짐에 따라 증가하다가 감소하였으며 최대값을 보이는 조사면크기는 쐐기각이 커짐에 반하여 감소하였으며 투과력에 관계없이 60。 쐐기에 대해서는 조사면 크기가 4 cm(A/P=1) 이상에서 조사면크기가 커짐에 따라 감소하였다. 6 MV 엑스선 에 대한 10 cm 깊이에서 15。 쐐기와 15 MV 엑스선에 대한 10 cm 깊이에서 45。 쐐기의 A/P 가 1.5보다 작은 조사면을 제외하고는 조사면의 크기가 커짐에 따라 %ROD는 감소하였다. $d_{max}$에서는 15。 쐐기와 30。 쐐기에 대해서는 %ROD가 음수였으며 절대값이 증가하였다. 이는 곧 조사면의 크기가 커짐에 따라 상부쐐기의 쐐기출력계수가 하부쐐기와 접근하고 드디어는 상부쐐기의 출력인수가 하부쐐기의 출력인수보다 작아질 수도 있다는 것을 의미하고 있다. 또한 %ROD 는 쐐기각이 클수록 변화가 컸으며, 조사면 크기가 커짐에 따라 10 cm 깊이에서보다 $d_{max}$에서 더 급하게 감소하였다. %ROD 는 6 MV 엑스선에 대해서는 -0.52~4.18 % 였고, 15 MV 엑스선에 대해서는 -0.44-4.18 % 였다. 결론 : 두 가지 투과력의 엑스선이 방출되는 선형가속기의 상하부 쐐기와 가상쐐기의 출력인수를 측정하여 비교하였다. 결과에서 얻어진 결론은 아래와 같다. 1. 조사면의 크기가 커짐에 따라 금속쐐기의 출력계수 는 증가하였으나 가상쐐기의 경우는 증가하다가 감소하거나 큰 쐐기각에 대해서는 감소만 하였다. 2. 상부쐐 기와 하부쐐기는 쐐기출력인수가 4% 이상 차이가 날 수 있으므로 독립적으로 측정하여 이용하여야 할 것이다.것이다.다.

  • PDF