• 제목/요약/키워드: Wedge Beam

검색결과 90건 처리시간 0.02초

Ritz법을 이용한 쐐기형 봉의 진동 해석 (Vibration Analysis of Wedge Type Bar by Ritz Method)

  • 박석주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권8호
    • /
    • pp.877-882
    • /
    • 2005
  • This paper discusses the lateral vibration of a bar which has its tip free. The uniform bar has a solution by summation of some simple exponential functions But if its shape is not uniform, its solution could be by Bessel's function, or mathematical solution could not be existed. Enen if the solution of Bessel's function exists. as Bessel function is a series function. we must got the solution by numerical method Hereby the author Proposes the ununiform beam solution of the matrix method by Ritz's method. and Proposes a new deflection shape function.

Clwl-Dcb식편을 이용한 콘크리트의 개구형 파괴 (MODEL I FRACTURE IN CONCRETE USING CRACK LINE WEDGE LOADED DOUBLE CANTILEVER BEAM)

  • 송정근
    • 콘크리트학회지
    • /
    • 제1권2호
    • /
    • pp.101-112
    • /
    • 1989
  • 콘크리트에 선형파괴역할의 적용가능성을 연구한 많은 논문이 발표되었다. 본 논문에서는 CLWL-DCB식편을 이용한 콘크리트의 개구형파괴를 연구하였다. 표면구열길이는 리프리카를 사용하여 직접적인 방법으로 측정하였고, 이 결과은 실험에서 얻은 측정가중과 구열개구변위의 관계곡선을 이용하여 분석하였다. 감계응력강도계수와 감계구열선단위는 Two Parameter 모델을 사용하여 유효구열선단에서 구하였다. LEFM 구열단면과 실험으로 구한 구열단면으로부터 폐쇄압력을 얻기 위하여 중첩법을 적용하여 5종의 균열모델을 평가하였다.

Therapeutic Proton Beam Range Measurement with EBT3 Film and Comparison with Tool for Particle Simulation

  • Lee, Nuri;Kim, Chankyu;Song, Mi Hee;Lee, Se Byeong
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.112-119
    • /
    • 2019
  • Purpose: The advantages of ocular proton therapy are that it spares the optic nerve and delivers the minimal dose to normal surrounding tissues. In this study, it developed a solid eye phantom that enabled us to perform quality assurance (QA) to verify the dose and beam range for passive single scattering proton therapy using a single phantom. For this purpose, a new solid eye phantom with a polymethyl-methacrylate (PMMA) wedge was developed using film dosimetry and an ionization chamber. Methods: The typical beam shape used for eye treatment is approximately 3 cm in diameter and the beam range is below 5 cm. Since proton therapy has a problem with beam range uncertainty due to differences in the stopping power of normal tissue, bone, air, etc, the beam range should be confirmed before treatment. A film can be placed on the slope of the phantom to evaluate the Spread-out Bragg Peak based on the water equivalent thickness value of PMMA on the film. In addition, an ionization chamber (Pin-point, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The eye phantom was used for independent patient-specific QA. The differences in the output and beam range between the measurement and the planned treatment were less than 1.5% and 0.1 cm, respectively. Conclusions: An eye phantom was developed and the performance was successfully validated. The phantom can be employed to verify the output and beam range for ocular proton therapy.

비접촉 유리 두께 측정 장치 개발 (Developement of a System for Glass Thickness Measurement)

  • 박재범;이응석;이민기;이종근
    • 대한기계학회논문집A
    • /
    • 제33권5호
    • /
    • pp.529-535
    • /
    • 2009
  • This paper describes a measuring device of glass thickness using machine vision and image processing techniques on real-time. Today, the machine vision enable to inspect fast and exactly than human's eyes. The presented system has advantages of continuous measurement, flexibility and good accuracy. The system consists of a laser diode, a CCD camera with PC. The camera located on the opposite side of the incident beam measures the distance between two reflected laser beams from the glass top and bottom surface. We apply a binary algorithm to convert and analyze the image from camera to PC. Laser point coordination by border tracing algorithm is used to find the center of beam circle. The measured result was compared with micrometer and showed 0.002mm accuracy. Finally, the errors were discussed how to minimize the influence of glass wedge angle and angular error of moving stage.

Cross-sectional TEM Specimens Priparation of Precisely Selected Regions of Semiconductor Devices using Focused Ion Beam Milling

  • 김정태;김호정;조윤성;최수한
    • 한국재료학회지
    • /
    • 제3권2호
    • /
    • pp.193-196
    • /
    • 1993
  • A procedure for preparing cross-sectional specimens for transmission electron microscopy(TEM)by focused ion beam(FIB)milling of specific regions of semiconductor devices is outlined. This technique enables TEM specimens to be pripared at precisely preselected area. In-situ #W thin film deposition on the top surface of desired site is complementally used to secure the TEM specimens to be less wedge shaped, which is main shortcoming of previous FIB-assisted TEM sample preparation technique. This technique is quite useful for the TEM sample priparation for fault finding and the characterization of fabrication process associated with submicron contact technologies.

  • PDF

전자포탈영상 (EPI)을 이용한 의료용 선형가속기의 성능평가에 관한 연구 (A study of Quality evaluation for medical linear accelerator using Electronic Portal Imaging)

  • 윤성익;권수일;추성실
    • 한국의학물리학회지:의학물리
    • /
    • 제9권2호
    • /
    • pp.105-113
    • /
    • 1998
  • 고에너지 광자선을 발생시키는 의료용선형가속기의 선질은 경우에 따라 변이를 가져오게 된다. 이러한 변이를 정확하게 판정하여 줄 수 있는 방사선측정법의 활용은 매우 중요하다. 보편적으로 광자선의 측정에 있어서 전리함의 사용이 아주 빈번하였으나 전자포탈영상장치(EPID)의 등장은 새로운 방사선측정법에 대한 가능성의 시작을 예견해준다. 실험은 6MV 광자선의 대칭성, Light/Radiation congruence, 그리고 Wedge filter를 통한 간편한 에너지의 변화에측과 위치의 정확도에 대하여 측정을 시행하였다. 사실 방사선측정의 대표적인 방법은 물팬톰-전리함응 이용한 모델인데 본 실험에서는 영상의 화소가 지니는 디지탈 값을 적절한 소프트웨어로 읽어내어서 데이터를 환산하여 결과를 얻었다. 선행실험에서 얻은 상대선량률을 적용하여 대칭성에서는 조사야영역이 l0$\times$10$cm^2$ 일 때 횡축과 종축에서 1.2%, 1.2%로 비교적 오차가 적었다. 그리고 Light/Radiation field congruence 여부는 횡축이 0.3%, 그리고 종축이 0.2%로서 예상한 기대값에 접근하였다. 다음으로 wedge filter를 활용한 에너지의 변이와 위치의 정확도에 대한 움직임을 알 수 있었다.

  • PDF

The Effects of Nonmagnetic Bolus on Contralateral Breast Skin Dose during Tangential Breast Irradiation Therapy

  • Won, Young-Jin;Cho, Jae-Hwan;Kim, Sung-chul
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.133-140
    • /
    • 2016
  • In this study the contralateral breast skin dose was decreased. It was to apply the results to the clinical study after analysis of different radiation dose amounts to contralateral breast with nonmagnetic bolus and without nonmagnetic bolus. A Rando phantom was computed tomography (CT) simulated, five treatment plans were generated: open tangents, open field in field, wedge 15, wedge 30, and intensity-modulated radiotherapy (IMRT) plan with 50.4 Gy to cover sufficient breast tissue. Contralateral breast skin dose was measured at 8 points using a glass dosimeter. The average contralateral breast dose using nonmagnetic bolus showed better excellence in decreasing the absorbed dose in the order of $168{\pm}11.1$ cGy, $131{\pm}10.2$ cGy (29%), $112{\pm}9.7$ cGy (49%), and $102{\pm}9.5$ cGy (64%) than changing the treatment plan. This study focused on decreasing the effect of scattered dose by use of a nonmagnetic bolus on the contralateral breast during radiotherapy in breast cancer patients and an intriguingly significant decrease was observed parallel to the opposed beam.

6 MV X선의 주변선량분포 (A Study on the Peripheral Dose of 6MV X-ray Beam)

  • 최두호;김일한;하성환;박찬일
    • Journal of Radiation Protection and Research
    • /
    • 제14권1호
    • /
    • pp.24-33
    • /
    • 1989
  • 방사선 치료시 조사면 밖의 신체부위에도 소량의 방사선이 흡수되며 이러한 소량의 방사선은 치료부위에 따라서는 백내장, 생식기능장애, 태아에 대한 영향등으로 나타날 수 있다. 조사면 밖에서 흡수되는 방사선량인 주변선량의 양과 분포양상 및 이에 영향을 주는 요인을 규명하기 위하여 자동식 제어장치에 의해 제어되는 실리콘 다이오드 측정기를 이용 6MV X선을 조사하면서 주변선량을 물팬톰내에서 측정하였다. 조사면의 크기, 콜리메이터의 위치, 쐐기필터의 존재여부 및 쇄기필터의 각도가 주변선량에 미치는 영향을 측정하여 다음과 같은 결과를 얻었다. 1. 주변선량은 조사면의 경계선에서 멀어질수록 감소하지만 15cm 떨어진 부위에서도 최대 흡수선량의 2.4% $\sim$ 5%에 이른다. 2. 주변선량은 수표면으로부터 깊이 2-3mm 근처까지 선량증가 현상이 나타나 수표면 보다 0 $\sim$ 0.3%까지 높아지며 이후 급격히 감소하여 1.5cm 근처에서 0.5 $\sim$ 5%의 최소치에 도달한 후 다시 3 $\sim$ 8%로 증가한다. 3. 주변선량은 조사면의 크기가 클수록 증가하여 조사면 경계선에서 10cm깊이 5cm거리에서 조사면 5 $\times\;5cm^2$인 경우와 20 $\times\;20cm^2$인 경우 각각 3.5%와 8.2%로서 조사면의 크기에 따라 2배이상의 증가를 보인다. 4. 상부 콜리메이터 방향의 주변선량이 하부 콜리메이터 방향의 주변선량에 비하여 높으며 그 차이는 1% 미만이다. 5. 쐐기 필터를 사용시에는 개방조사면의 경우에 비하여 주변선량이 증가되었으며 특히 얇은 방향의 주변선량이 높아 각도가 60$^{\circ}$이고 조사면의 크기가 15 $\times\;15cm^2$일때 조사면 경계선으로부터 5cm거리에서는 3%정도의 주변선량의 차이를 보인다. 6. 쐐기필터의 각도가 클수록 주변선량이 증가하여 패기필터의 각도가 60$^{\circ}$일때에는 개방조사면에 비하여 약 2배 정도로 주변 선량이 증가한다.

  • PDF

CLINAC 1800 선형가속기의 15 MV X-선의 특성 (Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator)

  • 김계준;이종영;박경란
    • Radiation Oncology Journal
    • /
    • 제9권1호
    • /
    • pp.131-141
    • /
    • 1991
  • 국내에서 처음으로 사용되는 CLINAC 1800에서 발생된 15MV X-선의 특성을 구하기 위하여 3 Dimensional water Phantom Dosimetry system)를 이용하여 방사선 치료에 근간이 되는 심부선량 백분율(POD), 최대 조직 비율(TMR), 편평도(beam profile), 대칭도, Wedge인자 등을 측정하였고 선량계산을 위하여 출력 인자들을 구하였다. 1. 선축상 최대치 지점(Dmax)은 SSD 100cm일때 조사면이 $10\times10cm^2$에서 $3.0\pm0.1$ cm이였고 $4\times4cm^2,\;35\times35cm^2$에서 각각 $3.1\pm0.1\;cm,2.2\pm0.1$ cm으로 조사면이 넓어지면서 측정치가 표면에 가까워지는 결과를 보였다. 2. 조직표면 선량(Surface Dose)는 SSD 100cm일때 조사면이 $10\times10cm^2$에서 $15.5\%$이였고 $4\times4cm^2,\;35\times35cm^2$에서 각각 $9.8\%\;,51.2\%$로 조사면이 넓어지면서 표면 선량은 증가하는 결과를 보였다. 3. 심부선량 백분율(PDO)은 SSD 100cm에서 측정하였고 조사면이 $10\times10cm^2$이고 10cm depth에서 $76.8\%$이였고 $80\%,\;50\%$ 선량의 깊이는 각각 $9.1\pm0.1\;cm,19.9\pm0.2\;cm$으로 측정되었다. 4. 최대조직비율(TMR)은 심부선량 백분율(PDD)로부터 계산하였고 측정값과의 차이는 $10\times10cm^2$ 조사면에서 평균 $1\;%$ 이내의 오차를 보였다. 5. 대칭도(symmetry)와 편평도(flatness)는 조사면 $10\times10cm^2$일때 각각 $0.73\%,\;2.72\%$이였다. 6. 출력인자(output factor)는 $10\times10cm^2$ 기준 조사면에서 흡수선량을 1로 하였을때 $4\times4cm^2,\;35\times35cm^2$ 조사면에서는 각각 0.927, 1.087로 측정되었는데 조사면이 증가할수록 흡수량이 증가하는 결과를 보였다. 7. Wedge factor는 $15^{\circ}\;30^{\circ}\;45^{\circ}\;60^{\circ}$를 10cm깊이에서 측정하였는데 0.825, 0.099, 0.560, 0.457로 각각 측정되었고 아크릴 0.4 mm Tray의 투과율은 0.976이였다. 8. 15 MV X-선에 의한 납벽층의 반가층 두께는 13 mm였고 Cerrobend의 반가층은 15.5 mm으로 측정되었다.

  • PDF

향상된 동적쐐기인자(Enhanced Dynamic Wedge Factor)의 특성 및 적용에 관한 고찰 (The Study on Properties and Application of Enhanced Dynamic Wedge Factor)

  • 김대섭;반태준;염미숙;유순미;이우석;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제22권1호
    • /
    • pp.53-60
    • /
    • 2010
  • 목 적: 향상된 동적쐐기인자(EDW-Factor)의 핵심 내용을 적용한 수식으로 EDW-Factor을 쉽게 계산하고, 측정을 통하여 유효성을 평가하고자 한다. 대상 및 방법: EDW-Factor의 계산을 위한 구간선량표(Golden Segmented Treatment Table, GSTT)는 제공된 값을 이용하였다. 검출기는 물팬텀(Phantom)에서 0.6 cc 파머형 전리조와 전위계를 사용하였다. 측정은 선원표면거리 100 cm에서 측정점을 각 에너지의 최대선량점으로 하여 시행하였다. 광자선 에너지는 6 MV와 15 MV 모두 측정하였고, EDW는 Y1-OUT방향에서 $60^{\circ}$, $30^{\circ}$, $20^{\circ}$ EDW을 선택하였다. 치료계획시스템은 Eclipse planning system (Varian, USA)을 이용하였다. 모든 조사야와 EDW 방향에 대하여 EDW-Factor를 계산할 수 있도록 하고, 측정은 EDW-Factor의 특징을 잘 나타낼 수 있도록 EDW-Factor의 X, Y-jaw 의존성과 OFF-Axis 조사야 영향을 검증할 수 있는 조사야를 선택하였다. 결 과: Y1 조사야가 달라지면 EDW-Factor는 달라지고 그에 따라 측정값도 다르게 나타지만 계산값과 측정값의 오차는 1% 이내였다. 계산중심점(측정점)이 치료중심(isocenter)이거나 아니거나 EDW의 각도가 적어질수록 계산값과 측정값의 오차가 적어지는 경향을 나타내었다. 전체 조사야 크기 및 에너지에 따른 오차의 경향은 찾을 수 없었다. 측정 조건을 치료계획시스템에서 구현하여 얻어지는 MU와 상용프로그램에서 얻어진 EDW-Factor을 이용한 매뉴얼 계산 MU을 비교한 결과 그 차이가 없음을 알 수 있었다. 결 론: 일반적으로 알려진 EDW-Factor식에서 fitting 값을 제외하고 EDW-Factor의 핵심내용만을 적용한 수식으로 EDWFactor를 계산하고 측정하여 검증하였을 때 오차는 1% 이내로 보여, 정확한 EDW-Factor 계산 값을 얻을 수 있었다. 또한 상용프로그램에서 구현하여 각각의 조사야에서 EDW-Factor를 측정하지 않고, 보편적으로 쉽게 EDW-Factor를 얻을 수 있도록 하였다.

  • PDF