• Title/Summary/Keyword: Web-based Performance Monitoring

Search Result 87, Processing Time 0.024 seconds

Development of High Performance & Remote controlled UPS (원격 통제형 UPS 개발)

  • 이왕하;박가우;이진희;김덕규
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.369-374
    • /
    • 2002
  • This paper presented the development trend of UPS and SPS system has focused on large scale system and more convenient system to maintenance and management. In this paper, we proposed low price and high performance SPSs which can de voltage regulation, harmonic reduction, and capable capacity extension in power. These SPSs are composed by two SPSs in their functional structure, one is power control part including voltage regulation and instant voltage compensaton. The others part is web based monitoring and trend management part for more convenient to SPS operator.

  • PDF

Wind Generation Monitoring System Based on IEC61400-25 International Standard (IEC61400-25 국제 표준 프로토콜을 적용한 풍력 발전 모니터링 시스템 개발 사례)

  • Lee, Duck-Su;Lee, Jun-Chul;Hong, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.227-228
    • /
    • 2008
  • This paper presents monitoring system based on IEC61400-25 for 750kW-class DFIG wind power generation system. It is consists of wind turbine PLC, Local and Remote I/O Server, human machine interface, and Web-server. Proposed System has been demonstrated in Daegi-ri, Kangwon-do, which aims to test IEC61400-25 communication capability of monitoring system and evaluate the performance of 750kW-class WTS.

  • PDF

The Implementation of a Lift Emergency Video Call System based on WebRTC using OpenAPI

  • Woon-Yong Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.10
    • /
    • pp.155-161
    • /
    • 2023
  • In this paper, we present a WebRTC-based emergency video call system structure that builds a service system in a constant monitoring environment to increase the usability and stability of elevator emergency call devices. The proposed system provides a smooth call environment between the emergency call system in the elevator and maintenance managers in case of an emergency, performs rapid response processing to elevator emergency calls through monitoring of the target elevator, and handles any emergency calls that may occur in the physical space of the elevator. The purpose is to build an environment that can implement low-latency, real-time video call services of voice and video by overcoming the physical constraints required for video calls. To this end, we have established a service environment based on OpenAPI, which is currently used in various fields and its performance has been proven, and provides video calls and emergency situation dissemination through rapid messaging by providing low-latency call quality. The presented system structure will be able to provide a basis for expanding various functions and constructing a reliable service environment and intelligent model for the elevator system through combination with the elevator control panel and various devices.

Implementation of Responsive Web-based Vessel Auxiliary Equipment and Pipe Condition Diagnosis Monitoring System (반응형 웹 기반 선박 보조기기 및 배관 상태 진단 모니터링 시스템 구현)

  • Sun-Ho, Park;Woo-Geun, Choi;Kyung-Yeol, Choi;Sang-Hyuk, Kwon
    • Journal of Navigation and Port Research
    • /
    • v.46 no.6
    • /
    • pp.562-569
    • /
    • 2022
  • The alarm monitoring technology applied to existing operating ships manages data items such as temperature and pressure with AMS (Alarm Monitoring System) and provides an alarm to the crew should these sensing data exceed the normal level range. In addition, the maintenance of existing ships follows the Planned Maintenance System (PMS). whereby the sensing data measured from the equipment is monitored and if it surpasses the set range, maintenance is performed through an alarm, or the corresponding part is replaced in advance after being used for a certain period of time regardless of whether the target device has a malfunction or not. To secure the reliability and operational safety of ship engine operation, it is necessary to enable advanced diagnosis and prediction based on real-time condition monitoring data. To do so, comprehensive measurement of actual ship data, creation of a database, and implementation of a condition diagnosis monitoring system for condition-based predictive maintenance of auxiliary equipment and piping must take place. Furthermore, the system should enable management of auxiliary equipment and piping status information based on a responsive web, and be optimized for screen and resolution so that it can be accessed and used by various mobile devices such as smartphones as well as for viewing on a PC on board. This update cost is low, and the management method is easy. In this paper, we propose CBM (Condition Based Management) technology, for autonomous ships. This core technology is used to identify abnormal phenomena through state diagnosis and monitoring of pumps and purifiers among ship auxiliary equipment, and seawater and steam pipes among pipes. It is intended to provide performance diagnosis and failure prediction of ship auxiliary equipment and piping for convergence analysis, and to support preventive maintenance decision-making.

Data Analysis Platform Construct of Fault Prediction and Diagnosis of RCP(Reactor Coolant Pump) (원자로 냉각재 펌프 고장예측진단을 위한 데이터 분석 플랫폼 구축)

  • Kim, Ju Sik;Jo, Sung Han;Jeoung, Rae Hyuck;Cho, Eun Ju;Na, Young Kyun;You, Ki Hyun
    • Journal of Information Technology Services
    • /
    • v.20 no.3
    • /
    • pp.1-12
    • /
    • 2021
  • Reactor Coolant Pump (RCP) is core part of nuclear power plant to provide the forced circulation of reactor coolant for the removal of core heat. Properly monitoring vibration of RCP is a key activity of a successful predictive maintenance and can lead to a decrease in failure, optimization of machine performance, and a reduction of repair and maintenance costs. Here, we developed real-time RCP Vibration Analysis System (VAS) that web based platform using NoSQL DB (Mongo DB) to handle vibration data of RCP. In this paper, we explain how to implement digital signal process of vibration data from time domain to frequency domain using Fast Fourier transform and how to design NoSQL DB structure, how to implement web service using Java spring framework, JavaScript, High-Chart. We have implement various plot according to standard of the American Society of Mechanical Engineers (ASME) and it can show on web browser based on HTML 5. This data analysis platform shows a upgraded method to real-time analyze vibration data and easily uses without specialist. Furthermore to get better precision we have plan apply to additional machine learning technology.

Heating and Cooling Performance Analysis of Ground Source Heat Pump System in Low Energy House (저에너지주택의 지열히트펌프시스템 냉·난방 성능분석)

  • Baek, Namchoon;Kim, Sungbum;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.10
    • /
    • pp.387-393
    • /
    • 2016
  • A ground source heat pump system maintains a constant efficiency due to its stable heat source and radiant heat temperature which provide a more effective thermal performance than that of the air source heat pump system. As an eco-friendly renewable energy source, it can reduce electric power and carbon dioxide. In this study, we analyzed one year of data from a web based remote monitoring system to estimate the thermal performance of GSHP with the capacity of 3RT, which is installed in a low energy house located in Daejeon, Korea. This GSHP system is a hybrid system connected to a solar hot water system. Cold and hot water stored in a buffer tank is supplied to six ceiling cassette type fan coil units and a floor panel heating system installed in each room. The results are as follows. First, the GSHP system was operated for ten minutes intermittently in summer in order to decrease the heat load caused by super-insulation. Second, the energy consumption in winter where the system was operated throughout the entire day was 7.5 times higher than that in summer. Moreover, the annual COP of the heating and cooling system was 4.1 in summer and 4.2 in winter, showing little difference. Third, the outlet temperature of the ground heat exchanger in winter decreased from $13^{\circ}C$ in November to $9^{\circ}C$ in February, while that in summer increased from $14^{\circ}C$ to $17^{\circ}C$ showing that the temperature change in winter is greater than that in summer.

A study of Service Component Based on Active Model Support Healthcare Application Service in u-Environment (u-환경에서 헬스케어 응용 서비스 지원 액티브 모델 기반의 서비스 컴포넌트에 관한 연구)

  • Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.11 no.2
    • /
    • pp.31-40
    • /
    • 2010
  • In this paper, we propose a service component based on active model for supporting a variety of u-healthcare application services. It implemented that component as a classification of function for developing healthcare application services. Especially we focus on the adaptive information service in integrated environment using a distributed object technologies of the various healthcare home service based on distributed object group framework. And we shows the service component applying to Healthcare application services such as healthcare home monitoring, mobile monitoring and web based monitoring. Also, we show the performance evaluation results such as response time, system load and network load.

Web-based Application Service Management System for Fault Monitoring

  • Min, Sang-Cheol;Chung, Tai-Myoung;Park, Hyoung-Woo;Lee, Kyung-Ha;Pang, Kee-Hong
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.6
    • /
    • pp.64-73
    • /
    • 1997
  • Network technology has been developed for very high-speed networking and multimedia data whose characteristics are the continuous and bursty transmission as well as a large amount of data. With this trend users wish to view the information about the application services as well as network devices and system hardware. However, it is rarely available for the users the information of performance or faults of the application services. Most of information is limited to the information related network devices or system hardware. Furthermore, users expect the best services without knowing the service environments in the network and there is no good way of delivering the service related problems and fault information of application services in a high speed network yet. In this paper we present a web-based application management system that we have developed for the past year. It includes a method to build an agent system that uses an existing network management standards, SNMP MIB and SNMP protocols. The user interface of the system is also developed to support visualization effects with web-based Java interface which offers a convenient way not only to access management information but also to control networked applications.

  • PDF

Smart Power Management Using RTOS-based Uninterruptable Generator Supply

  • Lee, Chulju;Kang, Kyungtae;Noh, Dong Kun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.6
    • /
    • pp.1-7
    • /
    • 2016
  • An uninterruptible power supply (UPS) allows small companies and domestic users to cope with power outages; but existing designs lack flexibility of control and require expensive battery maintenance, with a cost proportional to the outage compensation time. We combine a compact synchronous generator with a battery, with 10% of the capacity that would otherwise be required, to obtain a UPS with reduced maintenance costs for the same performance. Any UPS must respond immediately to a power loss, and our uninterruptible generator supply (UGS) is therefore built around real-time scheduling of its internal operations; this also makes it suitable for integration into the industrial gateway. The UGS is based on a real-time operating system, with an integrated wireless module providing connectivity to a web server, for monitoring and management, which can be performed remotely on a mobile device.

Performance Evaluation of Wireless and Wired Networks for Monitoring and Control of Indoor Air Quality(IAQ) in Subway Stations (지하철역사의 공기질 감시 및 제어를 위한 유무선 네트워크의 성능평가에 관한 연구)

  • Choi, Gi-Heung
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • In crowded subway stations indoor air quality (IAQ) is a key factor for ensuring the safety and health of passengers. Since physical variables that describing IAQ such as the concentration of particulate, $CO_2$, VOCs and biological agents need to be closely monitored and controlled in multiple locations within subway stations and in remote sites, concept of web-based monitoring and control network using both wireless and wired media needs to be implemented. Connecting remote wireless sensor network and device (LonWorks) networks to the IP network based on the concept of VDN can provide a powerful, integrated, distributed monitoring and control performance. In this study, performance of wireless and wired network in VDN for monitoring and control of IAQ in subway stations is evaluated. Specifically, delay induced in wireless and wired networks, and data transmission rate are evaluated. A key parameter is identified in assuring safety and health of passengers in subway stations.