• Title/Summary/Keyword: Weather resistance test

Search Result 51, Processing Time 0.022 seconds

The Development of the Hydrophobic - Low Viscosity Filling Material for the Surface Treatment for Pavement Preventive Maintenance (예방적 유지보수를 위한 소수성 저점도 AP 표면처리재 개발)

  • Choi, Jun Seong;Kim, Jo Sun
    • International Journal of Highway Engineering
    • /
    • v.16 no.2
    • /
    • pp.35-41
    • /
    • 2014
  • PURPOSES : Surface treatment is a favorable method in the pavement preventive maintenance. This study (Part I) aimed to develop the low viscosity filling material for waterproof characteristics and high penetrable and weather resistance, and a series of companion study (Part II) presents the coating characteristics and performance analysis using field and lab tests. METHODS : Hydrophobic characteristics of the advanced surface treatment material are observed and measured the filling depth and the permeability for sand and asphalt pavement specimen using the water absorption test and permeability test, X-RAY CT test. Color difference for the weather resistance using ultraviolet ray accelerated weathering test is compared with asphalt pavement specimens. RESULTS : The developed material shows the decreased water absorption and increased impermeable effect because of the hydrophobic characteristics. It is found that the filling depth is about 6mm and weather resistance is better than asphalt pavement specimen. CONCLUSIONS : The advanced hydrophobic - low viscosity filling treatment material is developed in this study (Part I) to improve the waterproof characteristics and high filling capacity and weather resistance for the pavement preventive maintenance.

Estimation of Optimal Weather Routing of a Ship using the Result of Model Test and Weather data

  • ;Jeon, Myeong-Jun;Yun, Hyeon-Gyu
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.10a
    • /
    • pp.152-154
    • /
    • 2015
  • 최적기상항로 추정의 주요 평가지수중 하나인 파랑중 부가저항의 모형시험을 이용하여 실해역의 불규칙파중 부가저항을 도출하였으며, 이를 평가지수로 갖는 A*알고리듬을 도입하여 최적기상항로를 추정하였다.

  • PDF

A Study on the Corrosion Resistance Test of Smoke Detectors (연기감지기의 내식시험에 관한 연구)

  • Kim, Hyeong-Gweon;Yoon, Hun-Ju;Kwon, Seong-Pil;SaKong, Seong-Ho;Back, Chang-Sun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.155-158
    • /
    • 2008
  • In this study we compared corrosion resistance tests which were carried out according to the national technique standard and the UL standard to ensure the reliability of smoke detectors in foul weather. The sensitivity of smoke detectors became so blunt that the least operational smoke concentration was a maximum change of 13% in the national technique standard, while it was a maximum change of 145% in the UL standard. As a result of this study the test method of corrosion resistance was made an objective evaluation in the national technique standard. Therefore it could be said that a basis of developing the test method of corrosion resistance was prepared for our country.

  • PDF

Degradation of Coatings under Atmospheric Tropical Conditions

  • To, Thi Xuan Hang;Pham, Gia Vu;Vu, Ke Oanh;Trinh, Anh Truc;Kodama, Toshiaki;Tanabe, Hiroyuki;Taki, Tohru;Nagai, Masanori
    • Corrosion Science and Technology
    • /
    • v.2 no.5
    • /
    • pp.207-211
    • /
    • 2003
  • The weather resistance of five coatings systems based on alkyd, chlorinated rubber, epoxy, polyurethane and fluoropolymer were studied by natural exposure test and accelerated test. The coatings were exposed at Hanoi station with urban industry atmosphere and at Baichay station with marine atmosphere. The degradation of coatings was evaluated by gloss measurement and surface analysis by scanning electronic microscopy. The results obtained show that among coatings tested the gloss of polyurethane and fluoropolymer coatings remained highly and those of alkyd, chlorinated rubber and epoxy coatings were very low after two years of atmospheric exposure. Under accelerating conditions the gloss of fluoropolymer coatings remained highly after 80 cycles of testing. By comparison with accelerating test in UV-condensation chamber the conditions at atmospheric stations are more aggressive.

Development of Ultra-Lightweight High Strength Trench Using Lightweight Polymer Concrete

  • Sung, Chan-Yong;Kim, Young-Ik
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.20-26
    • /
    • 2003
  • The ultra-lightweight high strength polymer concrete could be used for the drain structures under severe condition. In this study, materials used were unsaturated polyester resin, heavy calcium carbonate, artificial lightweight coarse aggregate and perlite. In the test results, the unit weight of the ultra-lightweight high strength polymer concrete was 946 kg f/$\textrm{m}^3$ and the compressive strength was appeared in 34.5 MPa. The compressive strength, splitting tensile strength, flexural strength, acid resistance and weather resistance were shown in excellently than that of the normal cement concrete. The draining trench had 1m length, 0.24 m width, 0.02 m thickness and 0.07 m height. The developed trench could be effectively used at the draining structures.

Study on Ship Performance in a Seaway for Application to Early Stage of Hull-Form Design (선박의 파랑 중 운항성능을 고려한 초기 선형설계에 대한 연구)

  • Jung, Yoo-Won;Kim, Yonghwan;Park, Dong-Min
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.3
    • /
    • pp.171-186
    • /
    • 2017
  • This paper introduces a study on ship performance in waves to consider the effects of added resistance in the early stage of hull-form design. A ship experiences a loss of speed in actual seaways, hence this study proposes the overall procedure of a new design concept that takes into account the hydrodynamic performance of ship in waves. In the procedure, the added resistance is predicted using numerical methods: slender-body theory and Maruo's far-field formulation, since these methods are efficient in initial design stage, and an empirical formula is adopted for short waves. As computational models, KVLCC2 hull and Supramax bulk carrier are considered, and the results of added resistance and weather factor for test models are discussed. The computational results of vertical motion response and added resistance of KVLCC2 hull are compared with the experimental data. In addition, the sensitivity analysis of added resistance and weather factor for KVLCC2 hull to the variations of ship dimensions are conducted, and the change of the added resistance and propulsion factors after hull form variations are discussed.

A Study on the Testing of Weather Resistance of Anti-corrosion Wax Covering Agents in the Locomotive at Jangdan Station of Gyeongui Line (경의선장단역증기기관차의 부식방지를 위한 왁스계 피복제 내후성 시험 연구)

  • Song, Won-Joon;Kim, Mi-Hyun;Ahn, Byong-Chan;Jeong, Hee-Don
    • Journal of Conservation Science
    • /
    • v.25 no.4
    • /
    • pp.373-381
    • /
    • 2009
  • To preserve steel cultural properties on display outdoors, the surface of these relics is processed with a covering treatment, which is a typical anti-corrosion method. Since the registered cultural heritage of Korea No. 78 Locomotive at Jangdan Station of Gyeongui Line will be treated by preservation process and displayed in the open outdoor area, effective surface covering agents were selected through testing to prevent the corrosion of the locomotive. The mixed wax are based on two types of microcrystalline wax which is one of regular surface covering agents for locomotives and bee‘s wax. For the weather resistance test, 3 types of wax were applied to each specimen of the locomotive and the specimens were tested in the Xenon-Arc Accelerated Weathering Tester for 1000 hours in accordance with the ISO 4892-1981 criteria and the test results were compared. As a result, on the surface of the specimen coated with the bee's wax, a whitening event appears after 400 hours which causes aging, and the specimens coated by the microcrystalline wax showed signs of a whitening event after 800 hours. The moisture contact angle with the microcrystalline wax coating was also less than with the bee's wax. Therefore, it was found that the high temperature microcrystalline wax is the most effective coating agent in terms of weather resistance and moisture blocking capability and the high temperature microcrystalline wax was adopted for coating the surface of the locomotive.

  • PDF

Characteristics of Rainfall Protection for Stacks (굴뚝의 우수유입방지 특성)

  • Kim, Jong-Chul;Kim, Tae-Hyeung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.18-31
    • /
    • 2000
  • A stack must be designed to 1) reduce or eliminate rainfall or snowfall into a industrial exhaust system, 2) minimize a resistance to flow, 3) maximize the vertical dispersion of the contaminated air and 4) minimize maintenance. The weather cone stacks and the elbow-type stacks are very popular in Korea. But they add some resistance to the exhaust system resulting in reduction of air flow rate, but also deflect the noxious contaminants downward in undiluted form. To solve these problems, ACGIH (American Conference of Governmental Industrial Hygienists) suggested the vertical discharge stack with concentric space between the upper stack with larger diameter and the lower stack with smaller diameter. The preliminary test showed that the vertical discharge stacks did not have the good rainfall protection. The reversed cone were newly devised to satisfy the requirements for the good stack. Subsequently, the amount of rain being penetrated through the stacks was measured while the stacks were simultaneously and naturally exposed to rain in the same area outside. Test results indicate that none of the stacks tested completely exclude rain. The efficiency of rainfall protection and the pressure loss coefficient were compared. The temporary conclusion was reached to the point that the reversed cone stack is the best one. Further research is underway.

  • PDF

Speed-Power Performance Analysis of an Existing 8,600 TEU Container Ship using SPA(Ship Performance Analysis) Program and Discussion on Wind-Resistance Coefficients

  • Shin, Myung-Soo;Ki, Min Suk;Park, Beom Jin;Lee, Gyeong Joong;Lee, Yeong Yeon;Kim, Yeongseon;Lee, Sang Bong
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.294-303
    • /
    • 2020
  • This study discusses data collection, calculation of wind and wave-induced resistance, and speed-power analysis of an 8,600 TEU container ship. Data acquisition system of the ship operator was improved to obtain the data necessary for the analysis, which was accomplished using SPA (Ship Performance Analysis, Park et al., 2019) in conformation with ISO15016:2015. From a previous operation profile of the container, the standard operating conditions of mean draft were 12.5 m and 13.6 m, which were defined with the mean stowage configuration of each condition. Model tests, including the load-variation test, were conducted to validate new ship performance and for the speed-power analysis. The major part of the added resistance of container ship is due to the wind. To check the reliability of wind-resistance calculation results, the resistance coefficients, added resistance, and speed-power analysis results using the Fujiwara regression formula (ISO15016:2015) and Computational fluid dynamics (Ryu et al., 2016; Jeon et al., 2017) analysis were compared. Wind speed and direction measured using an anemometer were used for wind-resistance calculation and the wave resistance was calculated using the wave-height and direction-data from weather information. Also, measured water temperature was used to calculate the increase in resistance owing to the deviation in water density. As a result, the SPA analysis using measured data and weather information was proved to be valid and able to identify the ship's resistance propulsion performance. Even with little difference in the air-resistance coefficient value, both methods provide sufficient accuracy for speed-power analysis. The differences were unnoticeable when the speed-power analysis results using each method were compared. Also, speed-power analysis results of the 8,600 TEU container ship in two draft conditions show acceptable trends when compared with the model test results and are also able to show power increase owing to hull fouling and aging. Thus, results of speed-power analysis of the existing 8,600 TEU container ship using the SPA program appropriately exhibit the characteristics of speed-power performance in deal conditions.

A Research on the Added Resistance Due to Weather at Sea (해상에서의 기상상태에 기인된 부가저항에 관한 고찰)

  • ;Townsin, R. L.
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.56-61
    • /
    • 1993
  • Standard values in graphic porms are presented for the ratio of added wave resistance to the sun of added wave and wind resistances in head sea for three ship types, tanker, container ship and passenger ship. The effect of ship length on the ratio defined above is investigated for the three ship types. Obique sea added resistance is determined using wave direction reduction factor. The factor is obtained from model test results and cubic spline interpolation technique.

  • PDF