• 제목/요약/키워드: Wearing sensation

검색결과 186건 처리시간 0.021초

The Study on the Physiological Response in Wearing Sportswear in Two Different Environments

  • Kwon, Oh Kyung;Kim, Jin-A
    • 한국의류산업학회지
    • /
    • 제2권5호
    • /
    • pp.416-422
    • /
    • 2000
  • In this study, to find out the physiological reaction of the human body and the sensation of comfort when people are wearing sportswear which is made of waterproof breathable fabrics under general environmental conditions (temperature : $20{\pm}1^{\circ}C$, humidity : $60{\pm}5%RH$, air current : 0.1 m/sec) and rainy environmental conditions (temperature : $20{\pm}1^{\circ}C$, humidity : $60{\pm}5%RH$, air current : 0.1 m/sec, rainfall : 250 1/hr), we made an experiment with sportswear in an artificial climate chamber and studied the thermal physiological response and subjective sensation. Mean skin temperature of the subjects was low and had a big range of fluctuation in rainy environmental conditions of two condition. Temperature started to increase at the beginning of the exercise, reached the maximum at the 2nd level of the exercise and then started to decline. Rectal temperature showed a slighter increase and bigger range of fluctuation in general conditions than in rainy conditions. Except clothing micro climate in rainy conditions, temperature and humidity and their range of fluctuation around back were higher than those around chest. Humidity was high and had wide range of fluctuation in general conditions. Heart rate was 4.4 beats/min higher in general conditions. In subjective test on rainy conditions, the feeling of discomfort increased due to the raindrops fallen on the skin. Unlike that in general conditions, cold sensation increased and humidity sensation reached to the peak after the exercise. In wearing sportswear made of shape memory breathable waterproof fabric, controlling function over a small amount of heat and water was distinctive while it turned out to be not so comfortable over a large amount of heat and water. Through this, the limitation of shape memory breathable waterproof fabric was recognised.

  • PDF

아토피 피부염환자의 봄.여름용 니트웨어 선호도 및 착용감 연구 (A Study on the Preference and Wearing Sensation of Spring/Summer Knitwears of Atopic Dermatitis)

  • 공진희;권영아
    • 복식
    • /
    • 제57권5호
    • /
    • pp.58-71
    • /
    • 2007
  • This study conducted a survey to find out atopic dermatitis patients' required performance and preference in design factors to develop spring/summer(S/S) knitwears preferred by atopic patients. On the platform of achieved information from statistical analysis, S/S knitwear samples for atopic patients were designed and constructed with cotton/Seacell(R) blended yarn, And subjective wearing sensation were evaluated comparing the samples and the commercial products made with cotton/chitosan blended yarn, trying to help producing more comfortable S/S knitwears for atopic patients. SPSS 12.0 program was used for frequency analysis, Chi-square analysis, ANOVA, and Duncan test. The result was as follows; For comfort of S/S knitwears, atopic patients most considered skin care property. Atopic patients preferred simple and basic knitwear in light color with thin and soft fabric such as plain knit. The preferred style was that 'appropriately fit with suitable ease'. They also preferred 'closed front'; 'boat neckline' and 'V neckline'; 'raglan sleeve' and 'set-in sleeve'. For hem trim, they preferred 'rib' structure. Male preferred simple and plain style with 'round collar' and 'tubular or rib trim", while female preferred sophisticated and characteristic style with 'set-in sleeve' with 'rib trim'. Under the circumstances with insufficient functional knitwears developed, this study tried to develop comfort S/S knitwears for atopic dermatitis patients and the developed knitwears showed as good as or better performance in wearing feeling, fitting, and appearance than the previously developed functional goods.

서열환경에서 근적외선 조사의복 착용시의 온열생리반응 (The Study of Thermo-physiological Responses with Near Infrared Lighted Garment at a Hot Environment)

  • 김성숙;김우종;김희은
    • 한국의류산업학회지
    • /
    • 제7권6호
    • /
    • pp.665-672
    • /
    • 2005
  • The purpose of this study was to assess the feasibility and the effects of near infrared lighted garments on thermo-physiological responses in human body. Seven healthy adult men were recruited for this study. All subjects were informed the contents and purpose of this study. The experiment was carried out in a climate chamber of $32^{\circ}C$, 60%RH with 'Rest', 'Exercise' and 'Recovery' period. The experimental garments consisted of briefs, undershirts(sleeveless), nightclothes, T-shirts, knee-trousers and socks. Subjects participated in two experiments, one was wearing near infrared lighted garments(NIR-O), the other was wearing regular garments(NIR-X). The order of experiment was randomized, and subjects wore experimental garments before 24 hours in order to benefit by near infrared light. Measurement items included rectal temperature ($T_{re}$), mean skin temperature ($\bar{T}_{sk}$), sweat rate, heart rate, oxygen uptake and subjective sensation. The results are as follows: As to the variation of rectal temperature and mean skin temperature, value of wearing NIR-X was higher than value of wearing NIR-O, indicating a significant level of difference (p<.001). Sweat rate under NIR-O and NIR-X condition were 575.35 g and 535.75 g, respectively. Heart rate value of NIR-X condition was higher than NIR-O. Oxygen uptake measured during experiment was the higher in NIR-X condition with significant difference (p<.001). In the subjective sensation, the value of NIR-O condition was higher than NIR-X condition without significantly difference.

통기성 향상을 위한 하계비행복 설계 및 착용쾌적성 평가 (Wearing Comfort Evaluation of a Summer Flight Suit to Improve Ventilation)

  • 전은진;박세권;유희천;김희은
    • 한국의류산업학회지
    • /
    • 제16권3호
    • /
    • pp.485-491
    • /
    • 2014
  • This study verified the effect of summer flight ventilation developed in a previous study based on wearing comfort evaluation. Seven healthy males in their twenties volunteered for this experiment conducted in aclimatic chamber. The experiment consisted of three consecutive periods of rest (20 minutes), running on a treadmill (10 minutes) and recovery (20 minutes). A comparative evaluation was conducted on the general flight suit which had no ventilation holes and summer flight suit that use subjective satisfaction measures and objective measures. The subjective satisfaction was evaluated according to the criteria of temperature sensation, wet sensation, thermal comfort and fatigue sensation. The objective satisfaction was measured by skin temperature, microclimate (temperature and humidity), sweat rate and thermography. The comparative wearing evaluation identified the summer flight suit decreased the temperature between skin and suit by $0.42^{\circ}C$ (upper arm), $0.9^{\circ}C$ (calf) and the skin temperature by $0.3^{\circ}C$ (shoulder), $0.4^{\circ}C$ (upper arm), $0.5^{\circ}C$ (calf) as compared to the general flight suit. The humidity inside the summer flight suit decreased at head (7.73%), shoulder (5.86%), upper arm (5.26%), and calf (8.73%) compared to the one inside the general flight suit. Thermography showed that the air flowed through ventilation holes (neck and armpit). The design of ventilation holes applied to the summer flight suit can be applicable to overall clothing that requires thermal comfort such as dust-free garments, mechanical clothing and combat uniforms.

고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest연구(2) - 개발제품의 온열생리학적특성 - (Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments(2) - Comparison in Terms of Thermophysiological Properties Between New Cooling Vest and Standard Cooling Vest -)

  • 권오경;김태규;김진아
    • 한국의류산업학회지
    • /
    • 제2권4호
    • /
    • pp.346-352
    • /
    • 2000
  • The purposes of this study are finding out thermophysiological properties throughout wearing experiment with standard cooling vest as well as providing data in order to design and apply more comfortable cooling vest. To do this study, we produced cooling vest newly. 1. Rectal temperature was ascended approximately from $37.2^{\circ}C$ to $38.05^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from $32.8{\sim}36.5^{\circ}C$, it was descended $1.0{\sim}1.1^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower $0.5^{\circ}C$. 2. While wearing developed cooling vest, it was found that they had lower tendency than standard cooling vest. Specifically in case of temperature within clothing (chest) $0.2{\sim}2.0^{\circ}C$ in case of humidity within clothing 2~8%RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. 3. In subjective sensation, standard cooling vest made negative response during experiment period from participants, but new cooling vest was nearing to comfortable area. It was con finned from above conclusions that wearing developed product is more effective in terms of comfort and reduction of heat stress in situation of working in hot environment.

  • PDF

냉각조끼착용에 따른 인체의 온열생리학적 특성 (Thermophysiological Response of Human Body in Wearing Codling Vest)

  • 권오경;김태규
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2000년도 추계학술대회 논문집
    • /
    • pp.148-154
    • /
    • 2000
  • To do this study, we produced cooling vest newly. Rectal temperature was ascended approximately from 37.2$^{\circ}C$ to 38.05$^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from 32.8∼36.5$^{\circ}C$, it was descended 1.0∼1.1$^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower 0.5$^{\circ}C$, While wearing developed product, it was found that they had lower tendency than exiting product. Specifically in case of temperature within clothing(chest) 0.2∼2.0$^{\circ}C$ in case of humidity within clothing 2∼8% RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. In subjective sensation, existing product made negative response during experiment period from participants, but developed product was nearing to comfortable area.

  • PDF

성별에 따른 대학생의 자기 건강 이미지와 착의 실태 차이 (Gender Difference of Self-health Image and Actual Wearing Conditions in University Students)

  • 정인희;권수애;이윤정;이주영;정운선
    • 한국의류학회지
    • /
    • 제37권1호
    • /
    • pp.64-75
    • /
    • 2013
  • This study suggests basic data on optimum thermal insulation for spring wear through an investigation of subjective thermal sensation, self-health image and actual wearing conditions. A survey of university students using a self-administered questionnaire was conducted to collect data on subjective thermal sensation, self-health image, wearing conditions, demographics and physical characteristics. The variable of wearing conditions was measured as the response to the clothing they were wearing. Garment items (26 types for males and 41 types for females) were suggested and the items worn by the students were converted into the thermal insulation values for clothing. The main results are as follows. As for the body type perception, males perceived themselves as not fat while females perceived themselves as not thin. As for the health perception, males perceived themselves healthier than females. As for the climate adaptability perception, females were more sensitive to cold than males. The average thermal insulation of clothing was 0.97clo (0.34-1.95clo) with higher insulation for males than females. Students were more sensitive to the cold when their BMI was lower, their body surface area per body weight was larger, and the more they perceived themselves as not healthy. There was a significant correlation between the self-health image of sensitiveness to cold and the thermal insulation of clothing. The results were synthetically discussed in terms of environmental physiology.

보호마스크의 내부 부피에 따른 착용 평가 (Wear Evaluation of Protective Mask according to Internal Volume)

  • 엄란이;박선희;박소영;이예진
    • 한국의류학회지
    • /
    • 제44권4호
    • /
    • pp.626-638
    • /
    • 2020
  • In this study, protective masks were designed in varying internal volume and analyzed in regards to wearing effect. Masks were measured by surface temperature and subjective wear evaluation. Four experimental masks were created with an increasing distance between the mask center line and nose in increments. The distances were set at 0.0 cm (M0), 2.0 cm (M2), 4.0 cm (M4), and 6.0 cm (M6). The area and volume of each experimental mask was measured and both measurements had a positive correlation with the set distances. Among the experimental masks, M2 was the most breathable. The heat between the face and the mask created by exhalation was able to escape from the mask and provided the highest comfort sensation when worn. Conversely, an internal volume that is too large would decrease its comfort because repetitive breathing deforms the appearance of the mask and adversely affects its fit. Therefore, creating and maintaining the optimal internal volume of the M2 mask is important to achieve maximum thermal sensation and ease of wear.

PCM 마이크로캡슐을 이용한 열조절 섬유소재 개발 -열조절 섬유소재의 착용효과- (Development of Thermoregulating Textile Materials with Microencapsulated Phase Change Materials(PCM) -Wearing comfort of the developed thermoregulating textile materials-)

  • 신윤숙;정영옥;전향란;손경희;김성희
    • 한국의류학회지
    • /
    • 제28권6호
    • /
    • pp.767-775
    • /
    • 2004
  • In order to evaluate physiological responses and comfort sensation of the developed thermoregulating textile material, polyester knit fabric was treated with phase change material (PCM) microcapsules by printing. Ten male subjects wearing an experimental best with and without PCMs were seated for 20 minutes, then exercised for 20 minutes, and then seated for 30 minutes in the chamber which was controlled under the temperatures of 20$\pm$1$^{\circ}C$, 50$\pm$5%R.H. The subject's skin temperature, microclimate inside garment and comfort sensation of two experimental bests were compared one another. As a result, the rectal temperature, skin temperature and mean skin temperature were similar in the two groups, and the subjects were not able to perceive the differences in comfort of the two experimental bests. However, the effect of PCM microcapsule could be seen from microclimate temperature and humidity. The microclimate temperature of the PCM garment at chest was significantly higher during exercise. The microclimate humidity of the PCM garment at chest was significantly lower during exercise and rest.

여름철 환경에서 팬이 있는 조끼의 인체 착용 효과 (Analysis of the Effects of Vests with Fan in Summer Environments)

  • 엄란이;이예진
    • 한국의류학회지
    • /
    • 제43권6호
    • /
    • pp.856-865
    • /
    • 2019
  • This study analyzed the effect of wearing a vest with an attached electric fan. Korean men in their 20s were given test "fan vests" equipped with fans on the chest, stomach, upper back, or lower back to wear. Participants wore them in a climate chamber set to replicate a summer environment (30±3℃, 75±1%RH, 0.2 m/sec). Subjective sensations and surface temperatures were measured. The attached fan on the front of the vest lowered the temperature of the vest and the skin surface where the fan was positioned, regardless of whether the wearer engaged in exercise. However, a fan attached to the lower back of the vest was effective in lowering the lower back of the vest as well as the upper back, back of the arm, and back of the neck. In addition, subjective evaluations indicated that a vest with fans attached to the stomach and lower back provided a cool sensation. However, it was confirmed that the design of an auxiliary tool capable of dispersing the weight is necessary since the weight of the fans can interfere with the comfort of wearing the vest.