• Title/Summary/Keyword: Wearable sensor device

Search Result 151, Processing Time 0.028 seconds

A Study of Simple Sleep Apnea Predictive Device Using SpO2 and Acceleration Sensor

  • Woo, Seong-In;Lee, Merry;Yeom, Hojun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.71-75
    • /
    • 2019
  • Sleep apnea is a disease that causes various complications, and the polysomnography is expensive and difficult to measure. The purpose of this study is to develop an unrestricted wearable monitoring system so that patients can be examined in a familiar environment. We used a method to detect sleep apnea events and to determine sleep satisfaction by non-constrained method using SpO2 measurement sensor and 3-axis acceleration sensor. Heart rate and SpO2 were measured at the finger using max30100. After acquiring the SpO2 data of the user in real time, the apnea measurement algorithm was used to transmit the number of apnea events of the user to the mobile phone using Bluetooth (HC-06) on the wrist. Using the three-axis acceleration sensor (mpu6050) attached to the upper body, the number of times of tossing and turning during sleep was measured. Based on this data, this algorithm evaluates the patient's tossing and turning during sleep and transmits the data to the mobile phone via Bluetooth. The power source used 9 volts battery to operate Arduino UNO and sensors for portability and stability, and the data received from each sensor can be used to check the various degree between sleep apnea and sleep tossing and turning on the mobile phone. Through thisstudy, we have developed a wearable sleep apnea measurement system that can be easily used at home for the problem of low sleep efficiency of sleep apnea patients.

Design and Implementation of Trackball Based UI for Efficient Text Entry on Smartwatch (스마트워치에서의 효율적인 문자입력을 위한 트랙볼 센서 기반 UI 설계 및 구현)

  • Lee, Ji-eun;Ahn, Jung-eun;Park, Kyeongsoo;Choi, Go-eun;Moon, Il-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.5
    • /
    • pp.452-457
    • /
    • 2015
  • Recently, wearable devices have gained popularity with familiar form factors and designs of eye-wear and watch to satisfy wearers' various preferences. Since UI/UX of smartphones can not be applied directly on smaller wearable devices, text entry on wearable devices is still problematic. In this paper, we first identify UI/UX problems of existing input methods and propose a new input method for wearable devices specifically targeting smartwatch platforms. We design and implement an efficient text entry method for wearable devices using trackball sensor and evaluate its performance and usability.

High Precision Electromagnetic Momentum Positioning with Current Loop

  • ZHANG, Chao;ZHAO, Yufei;WU, Hong
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.150-154
    • /
    • 2017
  • A novel high precision spatial positioning method utilizing the electromagnetic momentum, i.e., Electromagnetic Momentum Positioning (EMP), is proposed in this paper. By measuring the momentum of the electromagnetic field around the small current loop, the relative position between the sensor and the current loop is calculated. This method is particularly suitable for the application of close-range and high-precision positioning, e.g., data gloves and medical devices in personal healthcare, etc. The simulation results show that EMP method can give a high accuracy with the positioning error less than 1 mm, which is better than the traditional magnetic positioning devices with the error greater than 1 cm. This method lays the foundation for the application of data gloves to meet the accurate positioning requirement, such as the high precision interaction in Virtual Reality (VR), Augmented Reality (AR) and personal wearable devices network.

RGB-LED-based Optical Camera Communication using Multilevel Variable Pulse Position Modulation for Healthcare Applications

  • Rachim, Vega Pradana;An, Jinyoung;Pham, Quan Ngoc;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.6-12
    • /
    • 2018
  • In this paper, a 32-variable pulse position modulation (32-VPPM) scheme is proposed to support a red-green-blue light-emitting-diode (RGB-LED)-based optical camera communication (OCC) system. Our proposed modulation scheme is designed to enhance the OCC data transmission rate, which is targeted for the wearable biomedical data monitoring system. The OCC technology has been utilized as an alternative solution to the radio frequency (RF) wireless system for long-term self-healthcare monitoring. Different biomedical signals, such as electrocardiograms, photoplethysmograms, and respiration signals are being monitored and transmitted wirelessly from the wearable biomedical device to the smartphone receiver. A common 30 frames per second (fps) smartphone camera with a CMOS image sensor is used to record a transmitted optical signal. Moreover, the overall proposed system architecture, modulation scheme, and data demodulation are discussed in this paper. The experimental result shows that the proposed system is able to achieve > 9 kbps using only a common smartphone camera receiver.

Research Trends on Healthcare Wearables Published in Korean Journals

  • Kim, Nam Soon;Do, Wol Hee
    • Fashion & Textile Research Journal
    • /
    • v.22 no.5
    • /
    • pp.607-616
    • /
    • 2020
  • Health care wearables are devices that are attached to or combined with the human body to improve the health care capabilities of the human body that can be safely and adjustable according to preference. This study provided direction for future research on healthcare wearables in the field of clothing science, considering trends observed in this field from 2010 to 2019. Over the last 10 years, 812 studies have been conducted on healthcare wearables in Korea. Research has increased significantly since 2015, with a large number of articles published in this field. The research for this study was broken down into the following categories: technology development, marketing analysis, and technology analysis. The results according to the research method demonstrated that development and production methods were used most frequently, followed by trend analysis, experiment and evaluation, and survey. An analysis of keywords in the articles studied revealed that device, healthcare, big data (biometric data and database), and healthcare convergence technologies were trending. Similarly, detailed research on healthcare wearable devices and related technologies was actively being conducted. However, focusing on fiber, textiles, design, and clothing articles, in relation to the field of clothing in healthcare wearables, only 81 articles were found on this topic (10.0%), which was low compared to other studies. Therefore, it was determined that more research on healthcare wearables is necessary in the field of clothing.

Ultrafast and flexible UV photodetector based on NiO

  • Kim, Hong-sik;Patel, Malkeshkumar;Kim, Hyunki;Kim, Joondong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.389.2-389.2
    • /
    • 2016
  • The flexible solid state device has been widely studied as portable and wearable device applications such as display, sensor and curved circuits. A zero-bias operation without any external power consumption is a highly-demanding feature of semiconductor devices, including optical communication, environment monitoring and digital imaging applications. Moreover, the flexibility of device would give the degree of freedom of transparent electronics. Functional and transparent abrupt p/n junction device has been realized by combining of p-type NiO and n-type ZnO metal oxide semiconductors. The use of a plastic polyethylene terephthalate (PET) film substrate spontaneously allows the flexible feature of the devices. The functional design of p-NiO/n-ZnO metal oxide device provides a high rectifying ratio of 189 to ensure the quality junction quality. This all transparent metal oxide device can be operated without external power supply. The flexible p-NiO/n-ZnO device exhibit substantial photodetection performances of quick response time of $68{\mu}s$. We may suggest an efficient design scheme of flexible and functional metal oxide-based transparent electronics.

  • PDF

Axillary temperature measurements based on smart wearable thermometers in South Korean children: comparison with tympanic temperature measurements

  • Choi, Younglee;Ahn, Hye Young
    • Child Health Nursing Research
    • /
    • v.28 no.1
    • /
    • pp.62-69
    • /
    • 2022
  • Purpose: This study explored the validity of a new type of thermometer and parent satisfaction with the new device. This 24-hour continuous monitoring smart wearable wireless thermometer (TempTraq®) uses a very small semiconductor sensor with a thin patch-like shape. Methods: We obtained 397 sets of TempTraq® axillary temperatures and tympanic temperatures from 44 pediatric patients. Agreement between the axillary and tympanic measurements, as well as the validity of the TempTraq® axillary temperatures, were evaluated. Satisfaction surveys were completed by 41 caregivers after the measurements. Results: The TempTraq® axillary temperatures demonstrated a strong positive correlation with the tympanic temperatures. The Bland-Altman plot and analysis of TempTraq® axillary temperatures and tympanic temperatures showed that the mean difference was +0.45 ℃, the 95% limits of agreement were -0.57 to +1.46 ℃. Based on a tympanic temperature of 38 ℃, the results of validity of fever detection were sensitivity 0.85 and specificity 0.86. Satisfaction scores for TempTraq® temperature measurement were all > 4 points (satisfactory). Conclusion: TempTraq® smart axillary temperature measurement is an appropriate method for measuring children's temperatures since it was highly correlated to tympanic temperatures, had a reliable level of sensitivity and specificity, and could be used safely and conveniently.

Development of Real-Time Arrhythmia Detection and BLE-based Data Communication Algorithm for Wearable Devices (웨어러블 디바이스를 위한 실시간 부정맥 검출 및 BLE기반 데이터 통신 알고리즘 개발과 적용)

  • SooHoon, Maeng;Daegwan, Kim;Hyunseok, Lee;Hyojeong, Moon
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.399-408
    • /
    • 2022
  • Because arrhythmia occurs irregularly, it should be examined for at least 24 hours for accurate diagnosis. For this reason, this paper developed firmware software for arrhythmia detection and prevented consumption of temporal and human resources and enabled continuous management and early diagnosis. Prior to the experiment, the interval between the R peaks of the QRS Complex was calculated using the Pan-Tompkins algorithm. The developed firmware software designed and implemented an algorithm to detect arrhythmia such as tachycardia, bradycardia, ventricular tachycardia, persistent tachycardia, and non-persistent tachycardia, and a data transmission format to monitor the collected data based on BLE. As a result of the experiment, arrhythmia was found in real time according to the change in BPM as designed in this paper. And the data quality for BLE communication was verified by comparing the sensor's serial communication value with the Android application reception value. In the future, wearable devices for real-time arrhythmia detection will be lightweight and developed firmware software will be applied.

Wrist Wearable Device for the Measurement and Analysis of Physiological Signals (생체신호 측정 및 분석을 위한 손목 착용형 단말기)

  • Im, Jae Joong;Li, Ming Kui;Hwang, Chan Song
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.65-73
    • /
    • 2012
  • Wrist wearable device for the measurement of pulse rate, ECG, and activity during normal daily life, which could be used for the continuous monitoring and remote transmission of acquired data, was developed. Pressure sensor, device attached electrodes, and 3-degree accelerometer were used. Analysis algorithm and firmware program were established for providing diagnostic information for the users. Results of this study, possible for the management of health report and transmission of the results through bluetooth by wearing simple personal wrist device, could be used for the development of portable device in the u-healthcare environment.

A MEMS-Based Finger Wearable Computer Input Devices (MEMS 기반 손가락 착용형 컴퓨터 입력장치)

  • Kim, Chang-su;Jung, Se-hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.6
    • /
    • pp.1103-1108
    • /
    • 2016
  • The development of a variety of sensor technology, users smart phone, the use of motion recognition apparatus such as a console game machines is increasing. It tends to user needs motion recognition-based input device are increasing. Existing motion recognition mouse is equipped with a modified form of the mouse button on the outside and serves as a wheel mouse left and right buttons. Existing motion recognition mouse is to manufacture a small, there is a difficulty to operate the button. It is to apply the motion recognition technology the motion recognition technology is used only pointing the cursor there is a limit. In this paper, use of MEMS-based motion recognition sensor, the body of the two-point operation data by recognizing the operation of the (thumb and forefinger) and generating a control signal, followed by studies on the generated control signal to a wireless transmitting computer input device.