• Title/Summary/Keyword: Wearable Sensing

Search Result 99, Processing Time 0.027 seconds

Advances in Non-Interference Sensing for Wearable Sensors: Selectively Detecting Multi-Signals from Pressure, Strain, and Temperature

  • Byung Ku Jung;Yoonji Yang;Soong Ju Oh
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.340-351
    • /
    • 2023
  • Wearable sensors designed for strain, pressure, and temperature measurements are essential for monitoring human movements, health status, physiological data, and responses to external stimuli. Notably, recent research has led to the development of high-performance wearable sensors using innovative materials and device structures that exhibit ultra-high sensitivity compared with their commercial counterparts. However, the quest for accurate sensing has identified a critical challenge. Specifically, the mechanical flexibility of the substrates in wearable sensors can introduce interference signals, particularly when subjected to varying external stimuli and environmental conditions, potentially resulting in signal crosstalk and compromised data fidelity. Consequently, the pursuit of non-interference sensing technology is pivotal for enabling independent measurements of concurrent input signals related to strain, pressure, and temperature, ensuring precise signal acquisition. In this comprehensive review, we present an overview of the recent advances in noninterference sensing strategies. We explore various fabrication methods for sensing strain, pressure, and temperature, emphasizing the use of hybrid composite materials with distinct mechanical properties. This review contributes to the understanding of critical developments in wearable sensor technology that are vital for their ongoing application and evolution in numerous fields.

Wearable Sensing Device Design for Biological Monitoring (생체정보 모니터링을 위한 웨어러블 센싱 디바이스 디자인)

  • Lee, Jee Hyun;Lee, Eun Ji;Kim, Ji Eun;Kim, Yoolee;Cho, Sinwon
    • Journal of the Korean Society of Costume
    • /
    • v.65 no.1
    • /
    • pp.118-135
    • /
    • 2015
  • In recent years, smart clothing had been developed in order to better detect and monitor physical movement of the patient, so that such activities such as location identification and biometric recognition could be done. However, most of the sensing devices of smart clothing were limited to smart sensing sports clothing and the designs did not consider the physical characteristics and the behavior of the wearer. Therefore, this study aimed to create an open protection system by developing a wearable sensing device for health monitoring and location information. For this purpose, this study developed eleven types of wearable sensing design that could be commercially sold and worn by people who needed their biological information to be constantly monitored. The study conducted four tests in order to develop three types of sensing devices for various sensing wears. The purpose of this study was to expand the user rang of smart sensing wears, and provide a foundation for the development of distinctive wearable sensing devices reflecting the user. Furthermore, contribute to the design for the person subject to protection.

Periodic Biometric Information Collection Interface Method for Wearable Vulnerable Users

  • Lee, Taegyu
    • International journal of advanced smart convergence
    • /
    • v.10 no.3
    • /
    • pp.33-40
    • /
    • 2021
  • Recently, wearable computers equipped with various biosensors such as smart watches, smart bands, and smart patches that support daily health management of users as well as patients have been released. Users of wearable computers such as smart watches face various difficulties in performing biometric information processes such as data sensing, collection, transmission, real-time analysis, and feedback in a weak wireless and mobile biometric information service environment. In particular, the biometric information collection interface is an important basic process that determines the quality and performance of the entire biometric information service. So far, research has focused on sensing hardware and logic. This study intensively considers the interface method for effectively sensing and collecting raw biometric information. In particular, the process of collecting biometric information is designed and analyzed from the perspective of periodicity. Therefore, we propose an efficient and stable periodic collection method.

Wearable Textile Strain Sensors (웨어러블 텍스타일 스트레인 센서 리뷰)

  • Roh, Jung-Sim
    • Fashion & Textile Research Journal
    • /
    • v.18 no.6
    • /
    • pp.733-745
    • /
    • 2016
  • This paper provides a review of wearable textile strain sensors that can measure the deformation of the body surface according to the movements of the wearer. In previous studies, the requirements of textile strain sensors, materials and fabrication methods, as well as the principle of the strain sensing according to sensor structures were understood; furthermore, the factors that affect the sensing performance were critically reviewed and application studies were examined. Textile strain sensors should be able to show piezoresistive effects with consistent resistance-extension in response to the extensional deformations that are repeated when they are worn. Textile strain sensors with piezoresistivity are typically made using conductive yarn knit structures or carbon-based fillers or conducting polymer filler composite materials. For the accuracy and reliability of textile strain sensors, fabrication technologies that would minimize deformation hysteresis should be developed and processes to complement and analyze sensing results based on accurate understanding of the sensors' resistance-strain behavior are necessary. Since light-weighted, flexible, and highly elastic textile strain sensors can be worn by users without any inconvenience so that to enable the users to continuously collect data related to body movements, textile strain sensors are expected to become the core of human interface technologies with a wide range of applications in diverse areas.

Wireless Wearable GRF Sensing System for Continuous Measurements (연속적 데이터 획득을 위한 착용형 무선 지면 반력 측정 시스템)

  • Lee, Dongkwan;Jeong, Yongrok;Gu, Gwang Min;Kim, Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.3
    • /
    • pp.285-292
    • /
    • 2015
  • This paper presents a wireless ground reaction force (GRF) sensing system for ambulatory GRF recording. The system is largely divided into three parts: force sensing modules based on optical sensor, outsole type frame, and embedded system for wireless communication. The force sensing module has advantages of the low height, robustness to the moment interference, and stable response in long term use. In simulation study, the strain and stress properties were examined to satisfy the requirements of the GRF sensing system. Four sensing modules were mounted on the toe, ball, and heel of foot shaped frame, respectively. The GRF signals were extracted using Micrpcontroller unit and transferred to the smart phone via Bluetooth communication. We measured the GRF during the normal walking for the validation of the continuous recording capability. The recorded GRF was comparable to the off the shelf stationary force plate.

A Design of Infant's Body Temperature Sensing System Based on Embroidery Textile Conductive Wire (자수 도전사(傳導絲) 기반의 유아체온 센싱 시스템 설계 연구)

  • Song, Ha-Young;Lee, Kang-Hwi;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.862-867
    • /
    • 2016
  • In this study, the embroidery textile conductive wire of conductive yarn was designed into the wearable integrated clothing for sensing the infant's body temperature. To develop a high quality of the stable fiber-based textile conductive wire, firstly the five types of conductive yarns were twisted or covering polyester yarns and the coated conductive fiber with silver(Ag) or iron(Fe). As a result of comparative conductivity in conductive yarns of yarn processing, the 250 denier of conductive yarns with $0.74{\Omega}$/1~5cm were proposed and used for the integrated embroidery textile conductive wire for sensing. During experiments using the proposed embroidery textile conductive wire, measured resistance of thermistor according to the body temperature was correctly delivered to amplifier module, and showed feasible reliability of temperature sensing. As a wearable application, conductive yarns which takes forms of embroidery textile conductive wire would seems to be reliable as a conductive wire and could be replaced by the conductive metal wires.

Correlation between Visual Sensibility and Vital Signal using Wearable based Electrocardiogram Sensing Clothes (웨어러블 기반의 심전도 측정 의복을 이용한 시각감성과 생체신호간의 상관관계)

  • Chung, Kyung-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.496-503
    • /
    • 2009
  • In the life environment changed with not only the material abundance but also the quality, it is the most crucial factor for the strategy of sensibility engineering to investigate vital signal according to the sensibility. In this perspective, it is necessary to design and merchandise the products in cope with each sensibility and needs as well as its functional aspects. In this paper, we proposed the correlation between the visual sensibility and the vital signal using the wearable based electrocardiogram sensing clothes. We measured the electrocardiogram (ECG) signal by wearing the electrocardiogram sensing clothes. The heart rate variability (HRV) is calculated form the acquired ECG signal by wearing the electrocardiogram sensing clothes. And the power spectrum analysis using the Fast Fourier Transform (FFT) is evaluated the correlation between the visual sensibility and the vital signal. we plan to conduct empirical applications to verify the adequacy and the validity of the proposed method.

Real Time ECG Monitoring Through a Wearable Smart T-shirt

  • Mathias, Dakurah Naangmenkpeong;Kim, Sung-Il;Park, Jae-Soon;Joung, Yeun-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.1
    • /
    • pp.16-19
    • /
    • 2015
  • A wearable sensing ECG T-shirt for ubiquitous vital signs sensing is proposed. The sensor system consists of a signal processing board and capacitive sensing electrodes which together enable measurement of an electrocardiogram (ECG) on the human chest with minimal discomfort. The capacitive sensing method was employed to prevent direct ECG measurement on the skin and also to provide maximum convenience to the user. Also, low power integrated circuits (ICs) and passive electrodes were employed in this research to reduce the power consumption of the entire system. Small flexible electrodes were placed into cotton pockets and affixed to the interior of a worn tight NIKE Pro combat T-shirt. Appropriate signal conditioning and processing were implemented to remove motion artifacts. The entire system was portable and consumed low power compared to conventional ECG devices. The ECG signal obtained from a 24 yr. old male was comparable to that of an ECG simulator.

Wearable User Interface based on EOG and Marker Recognition (EOG와 마커인식을 이용한 착용형 사용자 인터페이스)

  • Kang, Sun-Kyoung;Jung, Sung-Tae;Lee, Sang-Seol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.6 s.44
    • /
    • pp.133-141
    • /
    • 2006
  • Recently many wearable computers have been developed. But they still have many user interface problems from both an input and output perspective. This paper presents a wearable user interface based on EOG(electrooculogram) sensing circuit and marker recognition. In the proposed user interface, the EOG sensor circuit which tracks the movement of eyes by sensing the potential difference across the eye is used as a pointing device. Objects to manipulate are represented human readable markers. And the marker recognition system detects and recognize markers from the camera input image. When a marker is recognized, the corresponding property window and method window are displayed to the head mounted display. Users manipulate the object by selecting a property or a method item from the window. By using the EOG sensor circuit and the marker recognition system, we can manipulate an object with only eye movement in the wearable computing environment.

  • PDF

Effect of Module Design for a Garment-Type Heart Activity Monitoring Wearable System Based on Non-Contact Type Sensing (비접촉식 심장활동 모니터링 기능 의복형 웨어러블 시스템의 모듈 효과 탐색)

  • Koo, Hye Ran;Lee, Young-Jae;Gi, Sunok;Lee, Seung Pyo;Kim, Kyeng Nam;Kang, Seung Jin;Lee, Jeong-Whan;Lee, Joo Hyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.39 no.3
    • /
    • pp.369-378
    • /
    • 2015
  • Various forms of wearable bio-signal monitoring systems have been developed recently. Acquisition of stable bio-signal data for health care purposes needs to be unconscious and continuous without hindrance to the users' daily activities. The garment type is a suitable form of a wearable bio-signal monitoring system; however, motion artifacts caused by body movement degrade the signal quality during the measurement of bio-signals. It is crucial to stabilize the electrode position to reduce motion artifacts generated when in motion. The problems with motion artifacts remain unresolved despite their significant effect on bio-signal monitoring. This research creates a foundation for the design of garment-type wearable systems for everyday use by finding a method to reduce motion artifacts through modular design. Two distinct garment-type wearable systems (tee-shirt with a motion artifact-reducing module (MARM) and tee-shirt without a MARM) were designed to compare the effects of modular design on the measurement of heart activity in terms of electrode position displacement, signal quality index value, and morphological quality. The tee-shirt with MARM showed superior properties and yielded higher quality signals than the tee-shirt without MARM. In addition, the tee-shirt with MARM showed a better repeatability of the heart activity signals. Therefore, a garment design with MARM is an efficient way to acquire stable bio-signals while in motion.