• Title/Summary/Keyword: Wear model

검색결과 561건 처리시간 0.028초

온라인 쇼핑몰에서 상품 표현방식에 따른 감성변화에 관한 연구 (A study of customer's emotional change by the ways of presenting pictures of clothing at online shops)

  • 박성종;석현정
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2008년도 추계학술대회
    • /
    • pp.74-77
    • /
    • 2008
  • Online shoppers are not able to try clothing on. Therefore, the pictures of clothing on the website play a significant role when shoppers make decision on their purchase. There are generally three different ways to show clothing at online shops. The first one is showing only clothing images, and the second one is showing the pictures that have actual fitting models wearing clothing on (In this case, Model's face is mostly not shown in the picture.), and the third is showing the pictures of professional fitting models who wear goods. The shopping malls adopt each of the different ways but little is known about affect on purchasing from these three ways. The aim of this study is to figure out how the online shopper's emotional status is affected by these three ways of presenting pictures of clothing. At first, we developed a set of adjective words of human emotion to set up the evaluation criteria for user's emotional status. Those adjectives are originally from the precedent research on human emotion. To cut 99 adjectives down to a proper number for the criteria, we conducted a preliminary survey, and finally, 5 adjectives are selected as appropriate criteria for evaluating users' emotional status while they are shopping. Those five adjectives are 'possess','sensual', 'unique', 'tasteful', and 'stylish'. Then, we conducted the main survey showing 10 kinds of cloth (each cloth was consist of 3 ways). And in the page of model images, we measured the model's preference for understanding the relation with customer's emotion criteria of the product. As a result of the test there was statistically significant difference between product only images and anonymous images, but there was no significant difference between anonymous images and model images. And the preference of the model and value of the emotion criteria have large correlation except 'unique' criteria. It is expected that the result in this study will help to build new marketing strategy which satisfy customers' emotion.

  • PDF

명상호흡 모니터링용 스마트의류를 위한 호흡수 측정 직물센서 연구 (A Study on the Textile Sensor Applied to Smart Wear for Monitoring Meditation Breathing)

  • 황수정;정윤원;이주현
    • 감성과학
    • /
    • 제21권1호
    • /
    • pp.83-90
    • /
    • 2018
  • 본 연구의 목적은 정신적, 신체적 힐링을 위한 명상용 스마트 의류 개발을 위한 기초연구로서 명상 시 복식호흡 수를 측정함으로써, 의복을 통해 명상의 진입상태를 모니터링 하기 위한 방법을 연구하는 것이다. 이를 위해 본 연구에서는 Single Wall Carbon Nano-Tube (SWCNT)를 기반으로 한 스트레인 게이지 타입의 직물센서를 구현하고, 1차 실험으로 0.1 Hz의 주기로 복부형태의 더미를 5 cm 길이로 2분간 개폐를 반복하여 명상호흡을 시뮬레이션 한 결과 참조전극인 BIOPAC과 직물호흡센서의 신호가 매우 높은 일치도를 나타냈다(p<0.001). 같은 조건으로 2차 본 실험에서 피험자 4명에게 명상호흡을 수행하도록 하였고, 배꼽점, 횡경막 부근 중심과 측면 총 4군데 위치에서 출력된 전압 값을 비교한 결과 배꼽점 중심 위치와 횡경막 측면에서 신호의 일치도가 높고, 크고 안정된 신호형태를 보여 명상호흡을 측정하기에 적합한 위치로 선정되었다. 따라서 본 연구에서는 긴 호흡주기의 명상호흡을 측정하기 위한 직물센서를 구현하고, 이 센서의 명상 호흡수 측정을 위한 신뢰성과 타당성을 검토하며, 인체 상 측정위치에 따른 호흡 수 측정효율을 비교, 고찰하는 것을 목표로 하였다.

전 슬관절 치환 성형술에 사용되는 초고분자량 폴리에틸렌 삽입물의 접촉응력에 관한 유한요소해석 (Finite Element Analysis for the Contact Stress of Ultra-high Molecular Weight Polyethylene in Total Knee Arthroplasty)

  • 조철형;최재봉;최귀원;윤강섭;강승백
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권1호
    • /
    • pp.37-44
    • /
    • 1999
  • 인공 슬관절에 사용되는 초고분자량 폴리에틸렌(Ultra-high molecular weight polyethylene : UHMWPE)의 마모는 삽입물의 수명을 결정하는 주요 요인으로 작용한다. UHMWPE의 마모로 입자가 발생하여 조직반응을 일으키고 이에 따른 일련의 반응으로 골용해가 일어나 인공관절의 실패의 원인으로 작용한다. 여러 보고들에 의하면 관절 운동시 발생하는 접촉응력은 UHMWPE의 마모에 영향을 미치는 주요한 인자 중 하나로 알려져 있다. 그러나 이러한 보고들은 관절 접촉면에서의 접촉 조건만을 고려했고 UHMWPE 삽입물을 지지하고 있는 금속 지지판과의 접촉면에서의 접촉 조건은 고려하지 않았다. 본 연구에서는 이러한 접촉 조건들을 고려하여 UHMWPE의 모양, 두께, 마찰, 굴곡 정도 그리고 구성 요소들에 대한 UHMWPE 표면과 내부에서의 응력해석을 통해 이들 변수가 UHMWPE의 마모현상에 미치는 영향을 알아보았다. UHMWPE의 모양에 따른 관절의 일치정도(conformity)에 대한 영향의 경우, 일치정도가 높은 모델이 응력을 줄여줄 수 있는 유형으로 나타났으며, 금속 지지판과의 접촉면에서 접촉조건을 준 경우가 완전히 결합된 것으로 가정한 경우보다 UHMWPE 내부에서의 최대 응력이 1-2mm 더 아래에서 나타났다. 또한 UHMWPE로만 된 유형이 금속 지지판이 있는 유형보다 낮은 응력분포를 보여줌으로써 높은 응력으로 인한 UHMWPE의 마모와 균열을 줄이기 위해서는 UHMWPE로만 된 유형의 삽입물의 사용이 좋을 것으로 사료되었다.

  • PDF

코르셋 타입 하네스의 신체 하중압력 분포 측정 및 가상착의 적용 (Investigation of the body distribution of load pressure and virtual wear design according to the corset type harness)

  • 권미연;최솔아;김주혜
    • 한국의상디자인학회지
    • /
    • 제23권3호
    • /
    • pp.1-10
    • /
    • 2021
  • Harnesses are used in a variety of industries, such as rescue operations, medicine, and entertainment. However, conventional harnesses have problems as they are uncomfortable to wear and causes continuous pain. Therefore, in this study, the load and pressure applied to the body in the flying state when using a conventional harness were measured in real time and the distribution change was observed. Load and pressure were measured using a modified corset harness, a pressure sensor, and a human mannequin to measure the maximum and average pressure on the waist. As a result, it was confirmed that the load concentrated on the waist in the flying state was 104 N, and the pressure was applied to the left and right sides was 800 kPa or greater. The pressure distribution showed a pressure of 3-45 kPa in 73% in all measurable pressures. The results of the load and pressure distribution are presented as basic data for improving the wearability and reducing the discomfort of harnesses in the future, aid in the development of a harnesses that can minimize discomfort for various activities, and increase the concentration on experiential activities. In addition, using the CLO 3D program, which is a 3D virtual wearing system, a harness was put on a virtual model, and the compression level was checked and compared with the actual pressure distribution. As a result of comparing the measured pressure values in the flying state with the clothing pressure wearing the harness in the CLO 3D program, the total pressure value was found to be about 68% of the actual measured value. This helps develop a harness that can minimize discomfort during activities by predicting the load and pressure on the body by first applying new designs to a virtual wearing system during development. These new harness patterns can solve the problems of conventional harnesses.

밀링 공구의 마모가 PMMA 임플란트 임시보철물 변연 및 내면적합도에 미치는 영향 (Effect of milling tool wear on the internal fit of PMMA implant interim prosthesis)

  • 신미선
    • 대한치과기공학회지
    • /
    • 제41권2호
    • /
    • pp.63-69
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the effect of CAD/CAM system milling tool wear on the marginal and internal fit of PMMA implant interim prosthesis three-dimensional manner. Methods: A total of 20 crowns were fabricated with CAD/CAM method. Their designs were unified to first molar of the left maxilla. The Customized abutments were prepared and scanned with on optical model scanner. Five crowns were milled by the newly replaced tool (1st milling), and 15 crowns were milled by 2nd, 3rd, 4th milling tool. The marginal and internal fit of 20 interim crowns were measured using the triple-scan protocol. Results: Statistically significant difference was found between the $1^{st}$ milling group ($51.8{\pm}14.6{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($128.6{\pm}43.8{\mu}m$, $146.2{\pm}38.1{\mu}m$, respectively) at the distal margins. In the mesial margins, There was a statistically significant difference between the $1^{st}$ milling group ($63.6{\pm}25.9{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($137.2{\pm}25.9{\mu}m$, $186.8{\pm}70.6{\mu}m$, respectively). In the distal line angle, significant difference was found between the $1^{st}$, $2^{nd}$, $3^{rd}$ milling groups and the $4^{th}$ milling group. In the mesial axial wall, significant difference was found between the $1^{st}$ milling group ($52.2{\pm}20.3{\mu}m$) and the $3^{rd}$, $4^{th}$ milling groups ($22.8{\pm}8.8{\mu}m$, $7.8{\pm}5.7{\mu}m$). Conclusion: As a result of the experiment, decrease of the marginal and internal fit was statistically significant as the number of machining cycles increased. In order to produce clinically excellent restorations, it is recommandable to consider the condition of the milling tool wear, when designing the restoration with CAD program.

Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar

  • Chae, Sung-Ki;Cho, Won-Tak;Choi, Jae-Won;Bae, Eun-Bin;Bae, Ji-Hyeon;Bae, Gang-Ho;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.12-21
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS. Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS. For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION. CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.

구매후 의복평가기준에 관한 연구-만족도, 상포태도, 재구매의도와의 관계를 중심으로- (A study of Post-purchase Clothing Evaluative Criteria: The Relationships Among Clothing Satisfaction, Brand Attitudes Repurchase Intention)

  • 여의재;이영선
    • 한국의류학회지
    • /
    • 제20권6호
    • /
    • pp.1027-1038
    • /
    • 1996
  • The decision making procedure of consumer's post purchase is important because post purchase evaluation function is the physiological variables in repurchasing. The previous studies of post-purchase decision making showed that consumer compared the expectation of pre-buying with the performance of the product of post-buying. After consumers evaluates the products, consumer is satisfactory or dissatisfactory with products. And the satisfaction effects repurchase intention. The criteria which consumer didn't consider can be important to consumer after buying. Therefore the research problems are as follows; 1. To reveal the consumer's post-purchase clothing evaluative criterita and to indentify the dimensions of post-purchase clothing evaluative criteria. 2, To examine a causal model of the repurchase intention by post- purchase clothing evaluative criteria, satisfaction and brand attitude, A questionnaire was developed and administered 530 women living in Taejeon, and social daytime wear was selected as a clothing item for the study. Consumer's post-purchase clothing evaluative criteria were composed of six dimensions; Fit, Utility, Management, Transformation, Wearing/sewing, Esthetic factor. The main causal model of repurchase intention is that post-purchase clothing evaluative criteria - satisfaction - brand altitude - repurchase intention. Finally we found that the post-purchase clothing evaluative criteria were important because the repurchase intention depended on post-purchase clothing evaluation, too.

  • PDF

Dependence of Dishing on Fluid Pressure during Chemical Mechanical Polishing

  • Higgs III, C. Fred;Ng, Sum Huan;Zhou, Chunhong;Yoon, In-Ho;Hight, Robert;Zhou, Zhiping;Yap, LipKong;Danyluk, Steven
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.441-442
    • /
    • 2002
  • Chemical mechanical polishing (CMP) is a manufacturing process that uses controlled wear to planarize dielectric and metallic layers on silicon wafers. CMP experiments revealed that a sub-ambient film pressure developed at the wafer/pad interface. Additionally, dishing occurs in CMP processes when the copper-in-trench lines are removed at a rate higher than the barrier layer. In order to study dishing across a stationary wafer during polishing, dishing maps were created. Since dishing is a function of the total contact pressure resulting from the applied load and the fluid pressure, the hydrodynamic pressure model was refined and used in an existing model to study copper dishing. Density maps, highlighting varying levels of dishing across the wafer face at different radial positions, were developed. This work will present the results.

  • PDF

성 관련 의복단서와 성 역할 정체감이 대인지각에 미치는 영향 -여대생을 중심으로- (Some Effects of Sex-linked Clothing Cue and Gender Schema on the Perception of Others -Research about student of Women s University-)

  • 이미현;임숙자
    • 복식문화연구
    • /
    • 제4권3호
    • /
    • pp.325-336
    • /
    • 1996
  • The main purpose of this study was to find the roles of sex related clothes. The result of the study showed that he effects of sex related clothes were vast and strong. 1. It appeared that sex related clothes affected the wearer's outside aspects and also inferred the wearer's inside characteristics. Subjects judged the wearer's sex by sex related clothes, and confidence in judgement about the wear's sex also appeared stronger when cue of sex related clothes is more clear than being ambiguous. Judging the model's impression when subjects evaluated other's appearance and personality ,clothes affected it and clothes also had a strong impact when subject inferred others's characteristics such as ability and activity. Among the three kinds of sex related cue like men's clothes, women's clothes and ambiguous clothes, when a model wore men's clothes, he mode's impression judged by the subjects was most favorable and positive. But respondents sex role identity appeared that it didn't affected the judgement of the wearer's sex, evaluation and inference of wearer's characteristics. But this result didn't match with the gender schema theory.

  • PDF

간극이 있는 링크구동계의 상태진단 (Condition Monitoring of Link Driving System with Clearance)

  • 최연선;민선환
    • 소음진동
    • /
    • 제11권1호
    • /
    • pp.125-131
    • /
    • 2001
  • There is a clearance between the parts of a machine due to design tolerance, manufacturing error, wear, looseness, or misalignment. If the clearance is large, the vibration and noise of the machine is generally large. Therefore, the analysis on the nitration and noise of a machine can tell the clearance of the machine, which reveals the condition of the machine, i.e., the existence of faults and the safety of the machine. The investigation of this kind of research should be on the basis of experimental results. A link mechanism with a clearance at a joint between the coupler and locker is made for the investigation of the condition monitoring of a machine due to clearance. The vibration and sound are measured from the link driving system during the operation. The signals are clarified using line enhancement technique. The noise removed signals are used to develop the dynamic model of the system for a model based fault diagnosis. Also this study showed that the clarified signals can be used for the calculation of the joint forces between the coupler and rocker and for the correlation between the vibration and sound levels and the clearance sizes.

  • PDF