• Title/Summary/Keyword: Wear Ring

Search Result 134, Processing Time 0.019 seconds

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.

A Study of the Personal Ornaments and Make-up of Maroccan (모로코인(人)의 장신구(裝身具)와 화장(化粧)에 관(關)한 연구(硏究))

  • Lee, Soon-Hong
    • Journal of Fashion Business
    • /
    • v.5 no.2
    • /
    • pp.15-34
    • /
    • 2001
  • Ornaments are accessories for the decoration of the body or dress. They aren't unavoidably required one, but serve to make one's dress perfect as decorative industrial art objects. In Morocco, ornaments were initially used as a sign of social position or the class or an incantatory symbol. In effect, they were originally employed to adjust one's dress, not just for decoration, and they were of use for household economy. Gold, silver and handcraft available for exchange were a means of increasing one's property and an indication of social standing and wealth. In particular, the dress and jewelry of a bride was a measure of her family's wealth, regarded as a symbol of her chastity and value. The ornaments symbolically back up people's faith in supernatural power, and their real value is based on implicit form or way of decoration, not the external shape. Specifically, there is a tendency to use the form of animal as a protector, not one to frighten people. In the artistic tradition of Morocco, fish pattern stands for water and rain, and eagle and bird are considered to be related to fate. Scorpion and lizard are depicted as an inquirer of sun, and snake is a symbol of abundance and sexual instinct, being viewed to have an ability to cure disease. Turtle pattern is a symbol of saint because it protects one from the evil. The ornaments are made of gold, silver, amber, clam, garnet, glass, nielle, enamel, glaze, coral or tree, and symbolic patterns are used, including hand(a symbol of five numerals), turtle, lizard, scorpion, eye, triangle, bird and eggs. They are very big and diverse, being categorized into ornaments for the head or the chest, neckless, fibula, earring, bracelet and ring. For Moroccans, make-up is a sort of instinctive behavior to meet aesthetic and sexual desire. They also wear make-up for practical purpose of protection, intentionally inflict a wound on the skin for ceremonial or religious purpose, paint the skin with pigment, or have the part of the body tattooed for incantatory purpose. All this actions are regarded as make-up. The raw material of cosmetics is aker, a vegetable dye. They get the lips or cheeks turn red and paint eyebrows with yellow saffran powder to have a bad devil lose its strength. Tattooing is mainly done by women and viewed as a sign of their value or social organization they belong to. Sometimes that is used to represent a woman's being old enough to marry or getting married already or the frequency of marriage. Besides, tattoo is believed to prevent or remedy loose bowels or cough, depending on its location or pattern, and they often change tattoo according to the change of beauty art.

  • PDF

A Study for Fire Examples Involved in Engine Coolant leakage, Brake and Exhaust System Over-Heating of Heavy-Duty Truck Vehicle (대형 트럭 자동차의 엔진냉각수 누출, 제동 및 배기시스템 과열에 관련된 화재사례 고찰)

  • Lee, IL Kwon;Kook, Chang Ho;Ham, Sung Hoon;Lee, Young Suk;Hwang, Han Sub;You, Chang Bae;Moon, Hak Hoon;Jung, Dong Hwa;Ahn, Ho Cheol;Lee, Jeong Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.4
    • /
    • pp.40-45
    • /
    • 2019
  • This paper is a purpose to study the failure example for heavy-duty vehicle fire. The first example, the researcher found the engine over-heating phenomenon causing a coolant leakage by the sealing poor of head-gasket because of D-ring part deformation contacting with cylinder liner top-part and cylinder head. He certified a fire breakout by short transferred to surrounding wiring of air-cleaner. The second example, a brake lining by return fault of break operating S cam causing with much wear of a rear 4 wheel brake lining repeatably was worn by friction. In the long run, it became the cause of fire. The third example, the researcher knew the fire cause was came about the short of wire by overload of tilting motor when the driver tilted up the cap to inspect a engine. Therefore, a heavy-duty fire must minimize the fire occurrence by thorough controlling.

Shielding Effect of Radiation Protector for Interventional Procedure (중재적 방사선 분야 방호용구 차폐효과)

  • Ko, Shin-Kwan;Kang, Byung-Sam;Lim, Chung-Hwang
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.213-219
    • /
    • 2007
  • The purpose of this study is to evaluate shielding effect of radiation protector for interventional radiologists in procedures by measuring inside and outside of radiation protector. In this study, we measured the radiation dose of 4 interventional radiologists during TACE and PTBD procedure for 4 month(2005.05-2005.09). Absorbed dose were measured by TLD placed underneath and over radiation protector such as Goggle, Thyroid protector, Apron and placed on the 4th finger of Hand. In addition, we measured background radiation dose in the control room using TLD. During TACE procedure, using 0.07 mmPb Goggle decreased average 53.8% of radiation dose rate in continuous fluoroscopic mode and decreased average 77.6% of radiation dose rate in pulse fluoroscopic mode. Using 0.5 mmPb Thyroid protector decreased average 88.9% of radiation dose rate in continuous fluoroscopic mode and decreased average 92.8% in pulse fluoroscopic mode. During PTBD procedure, using 0.07 mmPb Goggle decreased radiation dose rate average 62.7%, 87.9% by 0.5 mmPb Thyroid protector, 90.5% by 0.5 mmPb Apron. The average fluoroscopic time of PTBD was 6.14 min. shorter than TACE procedure, but radiation exposure dose rate of PTBD was 3 times higher in total body dose, and 40 times higher in hand dose rate than TACE. Interventional radiologists must wear thicker protector recommended over 0.5 mmPb. Also, they must use lead Goggle during interventional procedure. Abdomen dose decreased average 38.4% by drawing a lead curtain under the patient's table, therefore, they must draw a lead curtain to shield scattering ray. Radiation exposure dose decreased average 59.0% by using pulse fluoroscopic mode. So radiologists would better use pulse fluoroscopic mode than continuous fluoroscopic mode to decrease exposure dose.

  • PDF