• 제목/요약/키워드: Weak-story

검색결과 86건 처리시간 0.022초

시청 불편감을 유발하는 스테레오스코픽 3D 비디오 콘텐츠의 복합적 요인들의 실증적 분석 (Substantive Analysis of Composite Factors Causing Viewer's Discomfort for Stereoscopic 3D Video Contents)

  • 김동욱;김우열;서영호
    • 디지털산업정보학회논문지
    • /
    • 제8권3호
    • /
    • pp.97-124
    • /
    • 2012
  • This paper analyzes qualitatively the stereo 3D content factors causing viewer's discomfort. For this, we perform a subjective test that each subject strokes a specific key whenever he (she) feels discomfort during watching a stereo 3D contents. Also we extract the data for the factors in the 3D contents to obtain their quantitative values and the amounts of the temporal changes. Those two sets of data are used to analyze the contents to find the factors which cause viewer's discomfort. The factors to be considered are the amount and the frequency of the disparity changes, story of the contents, situation or environments of a scene, movement and the position of the camera, color and luminance information as well as disparities themselves. We analyse the various strong and weak factors and their composites to find how much discomfort each factor or composite causes. We also show the situations and their related factors that causes less discomfort than the amount of their disparities.

송림사(松林寺) 전탑(塼塔) 출토(出土) 금동제(金銅製) 사리장치(舍利裝置)의 보존처리(保存處理) (Conservation Treatment of Gilded bronze Sarria Reliquary Excavated from Songlim Temple Tower)

  • 김종오
    • 박물관보존과학
    • /
    • 제3권
    • /
    • pp.1-7
    • /
    • 2001
  • 송림사 전탑내 출토 금동제 사리장치(보물 제325-1호)는 일괄품인 유리제 사리기와 함께 매우 중요한 통일신라 사리장엄구의 하나로 꼽을 수 있다. 국립중앙박물관 보존실에서는 처리전 조사를 통하여 이 사리장치가 내부목재의 부후와 금동재질의 부식으로 인하여 상당히 위약해져 있음을 파악하고, 이를 보완하고 추후 발생할 수 있는 새로운 부식에 대한 예방에 중점을 두고 보존처리를 실시하였다. 또한 그동안의 송림사 전탑 출토 사리장치에 대한 정밀조사자료가 미비하여 정밀실측, 현미경조사 및 X-선 촬영 등의 세부적인 조사도 병행하였다.

Dynamic identification of soil-structure system designed by direct displacement-based method for different site conditions

  • Mahmoudabadi, Vahidreza;Bahar, Omid;Jafari, Mohammad Kazem;Safiey, Amir
    • Structural Engineering and Mechanics
    • /
    • 제71권4호
    • /
    • pp.445-458
    • /
    • 2019
  • This study mainly aims to assess the performance of soil-structure systems designed by direct displacement-based method coupled with strong column-weak beam design concept through various system identification techniques under strong ground motions. To this end, various system identification methods are employed to evaluate the dynamic characteristics of a structure (i.e., modal frequency, system damping, mode shapes, and plastic hinge formation pattern) under a strong seismic excitation considering soil-structure interaction for different site conditions as specified by ASCE 7-10. The scope of the study narrowed down to the code-complying low- to high-rise steel moment resisting frames with various heights (4, 8, 12, 16-story). The comparison of the result of soil-structure systems with fix-based support condition indicates that the modal frequencies of these systems are highly influenced by the structure heights, specifically for the softer soils. This trend is more significant for higher modes of the system which can considerably dominate the response of structures in which the higher modes have more contribution in dynamic response. Amongst all studied modes of the vibration, the damping ratio estimated for the first mode is relatively the closet to the initial assumed damping ratios. Moreover, it was found that fewer plastic hinges are developed in the structure of soil-structure systems with a softer soil which contradicts the general expectation of higher damageability of such structural systems.

고강도 표면매립용철근과 탄소섬유시트로 보강된 비연성 철근콘크리트 골조의 실물 진동기 실험 (Full-Scale Shaker Testing of Non-Ductile RC Frame Structure Retrofitted Using High-Strength Near Surface Mounted Rebars and Carbon FRP Sheets)

  • 신지욱;전종수
    • 한국지진공학회논문집
    • /
    • 제23권1호
    • /
    • pp.43-54
    • /
    • 2019
  • Existing reinforced concrete frame buildings designed for only gravity loads have been seismically vulnerable due to their inadequate column detailing. The seismic vulnerabilities can be mitigated by the application of a column retrofit technique, which combines high-strength near surface mounted bars with a fiber reinforced polymer wrapping system. This study presents the full-scale shaker testing of a non-ductile frame structure retrofitted using the combined retrofit system. The full-scale dynamic testing was performed to measure realistic dynamic responses and to investigate the effectiveness of the retrofit system through the comparison of the measured responses between as-built and retrofitted test frames. Experimental results demonstrated that the retrofit system reduced the dynamic responses without any significant damage on the columns because it improved flexural, shear and lap-splice resisting capacities. In addition, the retrofit system contributed to changing a damage mechanism from a soft-story mechanism (column-sidesway mechanism) to a mixed-damage mechanism, which was commonly found in reinforced concrete buildings with strong-column weak-beam system.

Variation in wind load and flow of a low-rise building during progressive damage scenario

  • Elshaer, Ahmed;Bitsuamlak, Girma;Abdallah, Hadil
    • Wind and Structures
    • /
    • 제28권6호
    • /
    • pp.389-404
    • /
    • 2019
  • In coastal regions, it is common to witness significant damages on low-rise buildings caused by hurricanes and other extreme wind events. These damages start at high pressure zones or weak building components, and then cascade to other building parts. The state-of-the-art in experimental and numerical aerodynamic load evaluation is to assume buildings with intact envelopes where wind acts only on the external walls and correct for internal pressure through separate aerodynamic studies. This approach fails to explain the effect of openings on (i) the external pressure, (ii) internal partition walls; and (iii) the load sharing between internal and external walls. During extreme events, non-structural components (e.g., windows, doors or rooftiles) could fail allowing the wind flow to enter the building, which can subject the internal walls to lateral loads that potentially can exceed their load capacities. Internal walls are typically designed for lower capacities compared to external walls. In the present work, an anticipated damage development scenario is modelled for a four-story building with a stepped gable roof. LES is used to examine the change in the internal and external wind flows for different level of assumed damages (starting from an intact building up to a case with failure in most windows and doors are observed). This study demonstrates that damages in non-structural components can increase the wind risk on the structural elements due to changes in the loading patterns. It also highlights the load sharing mechanisms in low rise buildings.

고감쇠 고무와 강재를 사용한 이중감쇠 제진시스템의 내진성능 (Seismic Performance of Dual Damper System Using High Damping Rubber and Steel)

  • 김정욱;김동건
    • 대한건축학회연합논문집
    • /
    • 제21권1호
    • /
    • pp.185-192
    • /
    • 2019
  • Recently, the frequency and magnitude of earthquakes are increasing worldwide. In Korea, the Gyeongju earthquake (2016) and the Pohang earthquake (2017) caused structural damage to many buildings. Since Korea's seismic design standards were revised to three or more stories in 2005, five-story buildings built before the revision are not designed to be earthquake-resistant. In this situation, if strong earthquake occurs in Korea, there will be great damage. To prevent this, seismic retrofit of buildings should be necessary. The seismic retrofit of classical method is mainly used to reduce the displacement generated in the structure by strengthening stiffness and strength. However, since this method increases the base shear force of the structure, it is difficult to apply it to buildings which have weak foundation. Therefore, in this study, we propose the damper system that reduces the response displacement of buildings and suppresses the increase of base shear force by using high damping rubber and steel. And the seismic performance of the damper system is verified through the experiment and the seismic analysis of the structure.

Development of self-centring energy-dissipative rocking columns equipped with SMA tension braces

  • Li, Yan-Wen;Yam, Michael C.H.;Zhang, Ping;Ke, Ke;Wang, Yan-Bo
    • Structural Engineering and Mechanics
    • /
    • 제82권5호
    • /
    • pp.611-628
    • /
    • 2022
  • Energy-dissipative rocking (EDR) columns are a class of seismic mitigation device capable of dissipating seismic energy and preventing weak-story failure of moment resisting frames (MRFs). An EDR consists of two hinge-supported steel columns interconnected by steel dampers along its height. Under earthquakes, the input seismic energy can be dissipated by plastic energy of the steel dampers in the EDR column. However, the unrecoverable plastic deformation of steel dampers generally results in residual drifts in the structural system. This paper presents a proof-of-concept study on an innovative device, namely self-centring energy-dissipative rocking (SC-EDR) column, aiming at enabling self-centring capability of the EDR column by installing a set of shape memory alloy (SMA) tension braces. The working mechanism of the SC-EDR column is presented in detail, and the feasibility of the new device is carefully examined via experimental and numerical studies considering the parameters of the SMA bar diameter and the steel damper plate thickness. The seismic responses including load carrying capacities, stress distributions, base rocking behaviour, source of residual deformation, and energy dissipation are discussed in detail. A rational combination of the steel damper and the SMA tension braces can achieve excellent energy dissipation and self-centring performance.

경제위기 이후 한국경제의 성장: 성장회계 및 성장회귀 분석 (Understanding Post-Crisis Growth of the Korean Economy: Growth Accounting and Cross-Country Regressions)

  • 한진희;신석하
    • KDI Journal of Economic Policy
    • /
    • 제30권1호
    • /
    • pp.33-70
    • /
    • 2008
  • 본 연구는 경제위기 이후 한국경제의 성장 둔화의 요인을 살펴보고, 국제비교적 관점에서 위기 이후의 성장 성과를 평가해 보았다. 수량변수 및 가격변수를 이용한 성장회계 분석 결과는 경제위기 이후 급격한 성장 둔화가 주로 노동자 1인당 자본축적의 둔화에 의해 설명되는 것으로 나타났다. 반면, 경제위기 이후 2001~05년 기간 중 총요소생산성 증가율은 경제 위기 이전인 1991~95년 시기에 비해 다소 높은 것으로 분석되었다. 한편 외환위기 이후 한국경제의 성장 둔화는 전 세계적 성장 둔화라는 시대적 요인과 동아시아 지역 고유의 요인에 대부분 기인한 것으로 분석되었다. 특히 자본축적의 둔화는 동아시아 지역 고유 요인에 주로 기인한 것으로 분석되었다. 국제비교적 관점에서 볼 때 전반적으로 위기 이후 한국경제의 성장 성과는 생산성 향상 및 자본축적이라는 측면에서 부정적으로만 평가하기는 어려운 것으로 보인다.

Seismic resistance of exterior beam-column joints with non-conventional confinement reinforcement detailing

  • Bindhu, K.R.;Jaya, K.P.;Manicka Selvam, V.K.
    • Structural Engineering and Mechanics
    • /
    • 제30권6호
    • /
    • pp.733-761
    • /
    • 2008
  • The failure of reinforced concrete structures in recent earthquakes caused concern about the performance of beam column joints. Confinement of joint is one of the ways to improve the performance of beam column joints during earthquakes. This paper describes an experimental study of exterior beam-column joints with two non-conventional reinforcement arrangements. One exterior beam-column joint of a six story building in seismic zone III of India was designed for earthquake loading. The transverse reinforcement of the joint assemblages were detailed as per IS 13920:1993 and IS 456:2000 respectively. The proposed nonconventional reinforcement was provided in the form of diagonal reinforcement on the faces of the joint, as a replacement of stirrups in the joint region for joints detailed as per IS 13920 and as additional reinforcement for joints detailed as per IS 456. These newly proposed detailing have the basic advantage of reducing the reinforcement congestion at the joint region. In order to study and compare the performance of joint with different detailing, four types of one-third scale specimens were cast (two numbers in each type). The main objective of the present study is to investigate the effectiveness of the proposed reinforcement detailing. All the specimens were tested under reverse cyclic loading, with appropriate axial load. From the test results, it was found that the beam-column joint having confining reinforcement as per IS: 456 with nonconventional detailing performed well. Test results indicate that the non-conventionally detailed specimens, Type 2 and Type 4 have an improvement in average ductility of 16% and 119% than their conventionally detailed counter parts (Type1 and Type 3). Further, the joint shear capacity of the Type 2 and Type 4 specimens are improved by 8.4% and 15.6% than the corresponding specimens of Type 1 and Type 3 respectively. The present study proposes a closed form expression to compute the yield and ultimate load of the system. This is accomplished using the theory of statics and the failure pattern observed during testing. Good correlation is found between the theoretical and experimental results.

비보강 조적조의 동적 거동 (Dynamic Response of Unreinforced Masonry Building)

  • 김남희;김재관
    • 한국지진공학회논문집
    • /
    • 제8권5호통권39호
    • /
    • pp.1-14
    • /
    • 2004
  • 본 연구는 우리나라에서 저층 주거용 건물로 널리 사용되고 있는 2층 규모의 비보강조적조 의 1/3 축소 모델에 대한 진동대 실험을 수행한 것이다. 본 연구의 주목적은 내진설계가 이루어지지 않은 조적조 건물의 내진거동을 살펴보고, 실험적 자료를 확보하는데 있다. 실험대상구조물은 횡방향으로는 대칭이지만 종방향으로는 약간 비대칭이고, 비교적 강한 다이어프램을 나타내는 콘크리트 슬래브로 되어있다. 실험체에 대한 모의 지진하중은 가속도를 점차 증가시켜가면서 종방향으로 가력하였다. 실험에서 얻은 구조물의 동적 응답자료는 진동대의 입력지진과 연관지어서 분석하였다. 더욱이 성능기초설계를 위한 성능수준을 제시하였다. 실험결과 1층에서의 전단파괴가 지배적이고 상부층은 강체거동을 보여주었다. 또한 균열 발생후에도 상당한 강도와 변형능력을 보유하고 있는 것으로 나타났다.