• Title/Summary/Keyword: Wax pattern

Search Result 77, Processing Time 0.03 seconds

The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment (변형된 임플란트 임시 지대주의 물성에 대한 연구)

  • Yang, Byung-Duk;Yoon, Tae-Ho;Choi, Un-Jae;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

A STUDY OF CORE TYPE AND LUTING CEMENTS ON COMPLETE CAST CROWN RETENTION (코어 형태와 시멘트 종류에 따른 전부주조금관의 유지력에 관한 연구)

  • Paek, Sang-Hyun;Chang, Ik-Tae;Lee, Sun-Hyung;Yang, Jae-Ho;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.169-177
    • /
    • 2000
  • The purpose of this study was to compare the retention of complete cast crown over amalgam ores, composite resin cores, and cast gold cores when cemented with three different luting agents. Eighteen core specimens each of amalgam(Bestaloy, Dong Myung, Seoul, Korea), composite resin (Z100, 3M Dental product, st. Paul, Minn) and type IV gold alloy (Ba-4, Heesung Engelhard Corp., Korea) were made in a customized milling stainless steel die. A wax pattern with a loop attached to occlusal surface was made for each core and a type II gold alloy casting was fabricated. The castings which had clinically acceptable marginal fit were used as test samples. The following luting cements were used to cement cast crowns on each core material : (1) zinc phosphate cement (Confi-dental Products Co., USA) (2) glass-ionomer cement (Fuji Plus, GC Industrial Corp., Tokyo, Japan) (3) resin cement (Panavia 21, Kuraray Co., USA). All cements were mixed according to manufacturers' instructions. A static load of 5kg was then applied for 10 minutes on the crowns. All specimens were stored in saline solution for 24 hours at $37^{\circ}C$ and thermocycled for 500 cycles. After storage and cycling, the tensile bond strengths were measured by using a universal testing machine (Instron Corp., Canton, Mass.) at a crosshead speed of 0.5mm/min. The results were as follows 1. The retentive strength of resin cement was the highest of alt three types of cement for resin core (p<0.05). 2. There was no statistical difference among the retentive strengths of three cements for amalgam core (p>0.05). 3. The retentive strength of resin cement was higher than that of zinc phosphate for cast core, but there was no difference between the retentive strength of glass ionomer cement and those of rein and zinc phosphate cement. 4. The retentive strength of the zinc phosphate cement for amalgam core was the highest of all type of cores.

  • PDF

A New Method to Identify PCA Oil Type through Solvent Extraction and Separation Skills in a SBR Vulcanizate (SBR 가황물에서 용매추출 및 분리에 의한 PCA 오일 Type 확인법)

  • Kim, Min-Saeng;Sohn, Kyung-Suk;Lee, Jung-Hun;Kim, Ik-Sik;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • v.47 no.1
    • /
    • pp.36-42
    • /
    • 2012
  • More than 3 wt% of polycyclic aromatics (PCAs) in process oil is known to cause skin cancer. The criterion of distinguishing between low PCA oil and high PCA oil is based on 3 wt% of PCA. High PCA oil is called as a carcinogen like distillate aromatic extract (DAE). Low PCA oil is considered as safety oils like treated distillate aromatic extract (TDAE), mild extract solvate (MES), and paraffinic oil. Four types of process oils such as DAE, TDAE, MES, and paraffinic oil purified by solvent extraction and separation skills from SBR vulcanizates were measured by FT-IR techniques. The effects of rubber chemicals such as N-1,3-dimethylbutyl-N'-phenyl-p-phenylnenediamine (HPPD), polymerized 2,2,4-trimethyl-1,2-dihydroquinoline (TMDQ), paraffin wax as antidegradants, and processing aid like Structol 40MS on paraffinic oil from SBR vulcanizates were also studied. The type of low or high PCA was identified by the relative abundance of absorbance at the aromatic substitution patterns of 864, 810, and $754cm^{-1}$ and at the paraffinic or naphthenic pattern of $721cm^{-1}$.

Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients (부분무치악 환자에서 구강스캐너의 지대주 자동중첩기능을 이용한 임플란트 고정성 보철물 수복 증례)

  • Park, Keun-Woo;Park, Ji-Man;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.79-87
    • /
    • 2021
  • The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient's visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an 'A.I. abutment matching algorithm' the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner's advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.

RELATIONSHIP BETWEEN CO-CR DISCREPANCY AND FACIAL SKELETAL TYPE (안면골격 형태와 중심교합위-중심위 변위간의 상관성에 관한 연구)

  • Cho, Jin-Young;Lee, Young-Jun;Park, Young-Guk;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.839-853
    • /
    • 1998
  • The present study was performed to prove the relationship between CO-CR discrepancy and facial skeletal type. In this study, 242 subjects were randomly selected and devided into 9 groups(devided into class I, II, III by ANB and each one devided into dolicho-, brachy-, mesofacial skeleton by Ricketts' vertical index). Lateral cephalometric radiographs with the mandible in centric occlusion were taken and measured and CO and CR bites were registered on all subjects. Diagnostic casts were mounted on Panadent articulator using an estimated face-bow and centric relation bite registration. The amount and direction of CO-CR discrepancy present was recorded using a Condylar Position Indicator(CPI) and a centric occlusion wax bite registration. CPI measurements and cephalometric measurements were statistically analyzed. The finding of this study can be summerized as follows : 1. There is little correlation between right and left sides for magnitude or direction of CO-CR discrepancies. The correlation between the magnitude of CO-CR discrepancy of left A-P and right A-P is higher than that of left S-I and right S-I. 2. Correlation of Class II malocclusion group was higher than that of the other groups between the magnitude of CO-CR discrepancy of left CPI and right CPI. 3. There is no difference between the pattern of CO-CR discrepancy of 9 malocclusion groups. 4. There is very little, if any, correlation between Skeletofacial measurements and CO-CR discrepancy. 5. In Class II brachyfacial skeleton and Class III mesofacial skeleton there was Lateral cephalometric measurements by that we predict CPI measurements was detected. That was overbite, overjet, upper genial angle, lower genial angle, saddle angle, articular angle, convexity of point A, ANS-Me/Na-Me, PCBL/RH, Posterior FH/anterior FH.

  • PDF

Comparison of Changes in Cell Wall Characteristics during Storage in 'Niitaka' and 'Pingguoli' Pear Fruits (동양배 '신고'와 '사과배' 과실의 저장 중 세포벽 특성의 변화 비교)

  • Kim, Jin-Gook;Piao, Yilong;Chun, Jong-Pil;Kataoka, Ikuo;Hwang, Yong-Soo
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • The characteristics of fruit ripening and cell wall modifications of two oriental pear fruits were compared during storage. The loss of fresh weight was lower in 'Pingguoli' than 'Niitaka', probably due to the difference in wax accumulation and skin structure. 'Pingguoli' produced much higher amount of ethylene and showed climacteric ripening pattern, but this response was not found in 'Niitaka'. A significant difference in soluble pectin contents was found, thus, the amount of water soluble pectins were much higher in 'Niitaka' at harvest but this difference was not significant at later stage of storage. A severe loss of water soluble pectins in 'Niitaka' was confirmed whereas a similar tendency was not found in CDTA soluble ones. Even the amount of $Na_2CO_3$ soluble pectins was relatively low, 'Pingguoli' contained approximately 2 times higher than 'Niitaka' and both cultivars showed an increasing tendency in $Na_2CO_3$ soluble polymers at later stage of storage. No significant difference in alkali soluble polysaccharides (hemicelluloses fraction) was found between both cultivars. There was a significant change in gel filtration profiles regardless of cultivars, especially in water soluble pectins resulting from severe depolymerization probably due to degradation of higher molecular weight pectins and loss of their side chains. In gel filtration profiles of $Na_2CO_3$ soluble pectins, neutral sugars were evenly distributed regardless of molecular size of pectic polymers but the decrease of high molecular weight fraction was found. In comparison of alkali soluble polymers, a similar trend was found, that is, there was no difference in gel filtration profiles but 'Niitaka' seemed to have longer side chains in alkali soluble polysaccharides in both 4% and 24% of KOH soluble fractions.

  • PDF

Studies on the Physical and Chemical Denatures of Cocoon Bave Sericin throughout Silk Filature Processes (제사과정 전후에서의 견사세리신의 물리화학적 성질변화에 관한 연구)

  • 남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.16 no.1
    • /
    • pp.21-48
    • /
    • 1974
  • The studies were carried out to disclose the physical and chemical properties of sericin fraction obtained from silk cocoon shells and its characteristics of swelling and solubility. The following results were obtained. 1. The physical and chemical properties of sericin fraction. 1) In contrast to the easy water soluble sericin, the hard soluble sericin contains fewer amino acids include of polar side radical while the hard soluble amino acid sach as alanine and leucine were detected. 2) The easy soluble amino acids were found mainly on the outer part of the fibroin, but the hard soluble amino acids were located in the near parts to the fibroin. 3) The swelling and solubility of the sericin could be hardly assayed by the analysis of the amino acid composition, and could be considered to tee closely related to the compound of the sericin crystal and secondary structure. 4) The X-ray patterns of the cocoon filament were ring shape, but they disappeared by the degumming treatment. 5) The sericin of tussah silkworm (A. pernyi), showed stronger circular patterns in the meridian than the regular silkworm (Bombyx mori). 6) There was no pattern difference between Fraction A and B. 7) X-ray diffraction patterns of the Sericin 1, ll and 111 were similar except interference of 8.85A (side chain spacing). 8) The amino acids above 150 in molecular weight such as Cys. Tyr. Phe. His. and Arg. were not found quantitatively by the 60 minutes-hydrolysis (6N-HCI). 9) The X-ray Pattern of 4.6A had a tendency to disappear with hot-water, ether, and alcohol treatment. 10) The partial hydrolysis of sericin showed a cirucular interference (2A) on the meridian. 11) The sericin pellet after hydrolysis was considered to be peptides composed with specific amino acids. 12) The decomposing temperature of Sericin 111 was higher than that of Sericin I and II. 13) Thermogram of the inner portioned sericin of the cocoon shell had double endothermic peaks at 165$^{\circ}C$, and 245$^{\circ}C$, and its decomposing temperature was higher than that of other portioned sericin. 14) The infrared spectroscopic properties among sericin I, II, III and sericin extracted from each layer portion of the cocoon shell were similar. II. The characteristics of seriein swelling and solubility related with silk processing. 1) Fifteen minutes was required to dehydrate the free moisture of cocoon shells with centrifugal force controlled at 13${\times}$10$^4$ dyne/g at 3,000 R.P.M. B) It took 30 minutes for the sericin to show positive reaction with the Folin-Ciocaltue reagent at room temperature. 3) The measurable wave length of the visible radiation was 500-750m${\mu}$, and the highest absorbance was observed at the wave length of 650m${\mu}$. 4) The colorimetric analysis should be conducted at 650mu for low concentration (10$\mu\textrm{g}$/$m\ell$), and at 500m${\mu}$ for the higher concentration to obtain an exact analysis. 5) The absorbing curves of sericin and egg albumin at different wave lengths were similar, but the absorbance of the former was slightly higher than that of the latter. 6) The quantity of the sericin measured by the colorimetric analysis, turned out to be less than by the Kjeldahl method. 7) Both temperature and duration in the cocoon cooking process has much effect on the swelling and solubility of the cocoon shells, but the temperature was more influential than the duration of the treatment. 8) The factorial relation between the temperature and the duration of treatment of the cocoon cooking to check for siricin swelling and solubility showed that the treatment duration should be gradually increased to reach optimum swelling and solubility of sericin with low temperature(70$^{\circ}C$) . High temperature, however, showed more sharp increase. 9) The more increased temperature in the drying of fresh cocoons, the less the sericin swelling and solubility were obtained. 10) In a specific cooking duration, the heavier the cocoon shell is, the less the swelling and solubility were obtained. 11) It was considered that there are differences in swelling or solubility between the filaments of each cocoon layer. 12) Sericin swelling or solubility in the cocoon filament was decreased by the wax extraction.. 13) The ionic surface active agent accelerated the swelling and solubility of the sericin at the range of pH 6-7. 14) In the same conditions as above, the cation agent was absorbed into the sericin. 15) In case of the increase of Ca ang Mg in the reeling water, its pH value drifted toward the acidity. 16) A buffering action was observed between the sericin and the water hardness constituents in the reeling water. 17) The effect of calcium on the swelling and solubility of the sericin was more moderate than that of magnecium. 18) The solute of the water hardness constituents increased the electric conductivity in the reeling water.

  • PDF